blower door resultsTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:47 Smoke Address:47 Smoke Ridge Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.307031 Longitude: -73.699815 Timestamp: 2020-02-20 16:58:37 Customer Information: Name:Foothills Builders Address:Queensbury, NY 12804 Measured Leakage:822.3 CFM50 Test ID:47 smoke Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.94 (+/- 1.6%)Effective Leakage Area: 39.7 in² Building Volume:16,800.0 ft³Enclosure Surface Area: 1,978.0 ft² Flow Coefficient (C):53.0 (+/- 7.4%)Exponent (n): 0.701 (+/- 0.021) Correlation Coefficient:0.99986 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 65 °F Altitude: 412.0 ft Outdoor Temp: 35 °F Time Average Period: 10 seconds Test Date and Time:2020-02-26 12:18:04 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.3 -60.0 -60.6 -59.3 -28.5 973.6 Ring A -48.0 -48.2 -46.9 -202.2 842.4 Ring B -35.0 -37.3 -36.0 -137.5 695.7 Ring B -23.0 -25.2 -23.9 -77.0 522.1 Ring B -10.0 -12.8 -11.5 -27.0 310.6 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 3173 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.