Signed Inspection Report (03-03-2020) (12).pdfINSPECTION WORKSHEET (SEP-001202-2020)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:SEP-0657-2019 Case Module:Permit
Inspection Date:Tue Mar 3, 2020 Inspection Status:Partial Pass
Inspector:John O'Brien Inspection Type:Septic
Job Address:Parcel Number:211 ASSEMBLY POINT RD
Lake George, NY, 12845
226.19-2-18
Contact Type Company Name Name
Granted Permission Steinbach, Erin
Engineer Environmental Design Partner (EDP)
Applicant Steinbach, Erin
Contractor Crandall Excavating
Primary Owner Steinbach, Erin
Checklist Item Status
Building Inspector Notes Passed
2/19/20 for placement of 1,000 gallon pump tank and Clarus fusion 450 ETU tank only prior to backfill.
3/3/20 Septic System Partial Approval
- 12'x36' Absorption Pressure Bed Only!
Remaining Items:
- Submit Engineer's Final Report & Certified Septic System As-Built.
- Witness operation of pumps and alarm system
- Eric Murdock needs to submit Clarius System's final report and maintenance agreement.
- Establish lawn
- Final Electrical Inspection
3/3/20 Septic System Partial Approval
Remaining Items:
- Submit Engineer's Final Report & Certified Septic System As-Built.
- Eric Murdock needs to submit Clarius System's final report and maintenance agreement.
- Establish lawn
- Final Electrical Inspection
Mar 03, 2020 Page (1)
INSPECTION WORKSHEET (SEP-001202-2020)
Checklist Item Status
- New Lake George water supply to residence needs to be installed.
- Property Transfer Inspection
Type of Water: Municipal / Well Water Failed
Installed new Lake George water supply
Waterline separation distance Failed
Well separation distance Passed
Neighbor's well 70' as per variance.
Absorbtion Fields: Total Length Passed
12'x36' Absorption Pressure Bed
Length of Each Trench Passed
3@36'
Depth of Trenches Passed
12"
System Use Status Failed
3/3/20 Septic System Partial Approval
Remaining Items:
- Submit Engineer's Final Report & Certified Septic System As-Built.
- Eric Murdock needs to submit Clarius System's final report and maintenance agreement.
- Establish lawn
- Final Electrical Inspection
- New Lake George water supply to residence needs to be installed.
- Property Transfer Inspection
Size of Stone Passed
#2
Mar 03, 2020 Page (2)
INSPECTION WORKSHEET (SEP-001202-2020)
Checklist Item Status
Building to Tank Passed
Residence to Clarius Tank
4" sch40 pvc
Clarius Tank to Pump Station
4" sch40 pvc
Tank to Distribution Box Passed
Pump tank to Field Manifold - 2" pvc sdr21 force-main
Distribution box to Field / Pit Passed
Manifold to pressure distribution lines - 1.5" pvc sdr21
Foundation to Tank Passed
18'+/-
Foundation to Absorption Failed
92'+/-
Conforms as per Plot Plan Failed
- Provide certified septic system as-built plan.
Engineer Report and As-Built Failed
ETU Maintenance Contract provided Failed
Location of system on property Failed
Mar 03, 2020 Page (3)
O'Brien, John