Loading...
Signed Inspection Report (03-03-2020) (13).pdfINSPECTION WORKSHEET (COMFIN-001212-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0615-2019 Case Module:Permit Inspection Date:Tue Mar 3, 2020 Inspection Status:Failed Inspector:John O'Brien Inspection Type:Commercial Final Inspection Job Address:Parcel Number:704 GLEN ST Queensbury, NY, 12804 302.6-1-58.1 Contact Type Company Name Name Granted Permission Carr, John Applicant Carr, John Architect Rucinski-Hall Architecture Primary Owner Landcrafter LLC Carr, John Checklist Item Status Blower Door Test Certification Failed Building Inspector Notes Failed 3/3/20 Preliminary Final Inspection Not Approved Remaining Items: - Submit final stamped as-built plans for hair salon. - Final Electrical Inspection - Provide letter from Ethan Hall stating that the project has been completed in accordance with the approved plans,specifications and COMcheck for lighting and mechanicals. - Install lever handle hardware missing on doors. - Complete installing handrails to 2nd floor private office. - Install trap wrap on bathroom sink trap. - Submit HVAC air balancing report. - Exit at north side of building needs to exit to grade as discussed. - Complete all Fire marshal items. Ext Finish /Grade Complete/6 in 10ft or Equivalent Failed Mar 03, 2020 Page (1) INSPECTION WORKSHEET (COMFIN-001212-2020) Checklist Item Status ÿþ Failed Doors 36 inch wLever Hand Panic Hardware, if req Failed Exits At Grade Or Platform 36 (w) x 44 (l)Failed Relief Valve ,Heat Trap/Water Temp 110 deg or less Failed Outside Spigots have Air Gap Failed Attic Access 30 x 20 x 30 (h)Failed Attic Access Gasketed Failed Attic Access Insulation = Attic R- Value Failed Final Electrical / Flex Gas Piping Bonded Failed Occupancy sensor lighting control Failed Bldg Num or Tenant Address on Bld or Drive Failed Mar 03, 2020 Page (2) INSPECTION WORKSHEET (COMFIN-001212-2020) Checklist Item Status Engineer or Architect Approval Failed OK to Issue Temporary C/O Failed 3/3/20 Preliminary Final Inspection Not Approved Remaining Items: - Submit final stamped as-built plans for hair salon. - Final Electrical Inspection - Provide letter from Ethan Hall stating that the project has been completed in accordance with the approved plans,specifications and COMcheck for lighting and mechanicals. - Install lever handle hardware missing on doors. - Complete installing handrails to 2nd floor private office. - Install trap wrap on bathroom sink trap. - Submit HVAC air balancing report. - Exit at north side of building needs to exit to grade as discussed. - Complete all Fire marshal items. OK to Issue C/O Failed Mar 03, 2020 Page (3) O'Brien, John