Loading...
Signed Inspection Report (03-09-2020).pdfINSPECTION WORKSHEET (RPLUM-001210-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0625-2018 Case Module:Permit Inspection Date:Mon Mar 9, 2020 Inspection Status:Failed Inspector:Mark Smith Inspection Type:Rough Plumbing Job Address:Parcel Number:154 CLEVERDALE RD Queensbury, NY, 12804 227.17-2-30 Contact Type Company Name Name Architect McLaughlin, Tim Concrete Contractor R. C. Springer Concrete Contractor Stonewood Development of Northeastern NY Inc Applicant HOFFMAN, JEAN Granted Permission HOFFMAN, JEAN Framing Contractor Top Notch Builders Primary Owner Stonewood Development of Northeastern NY Inc Engineer Environmental Design Partnership, LLC Checklist Item Status Building Inspector Notes Failed 3/9/20 rough plumbing not approved: All connections and fittings for sanitary piping must be made at time of inspection. 3" vent must be through the roof, or install dandy T type fitting so the connection can be verified at a later date. Sanitary lines should be capped outside the foundation, or install dandy T type fitting so the connection can be verified at a later date. All tub traps need to be in place at time of inspection. All connections from foundation to roof should be installed and pressurized at time of inspection. Supply piping connections must be completed before inspection. All shower valves and fittings should be completed at time of inspection. 65 psi for 15 minutes. Mar 09, 2020 Page (1) INSPECTION WORKSHEET (RPLUM-001210-2020) Checklist Item Status Plumbing Under Slab Failed Rough Plumbing / Nail Plates Failed Plumbing Vent Vents in Place Failed 3" Vent Through Roof Failed 1 ½ inch minimum Drain Size Failed Shower liner test (2" of water)Failed Washing Machine Drain 2 inch minimum Failed Washing Machine Trap: 18"-42" discharge Failed Cleanout every 100 feet change of direction Failed Pressure Test Failed Drain Vent Failed Air Head Failed Mar 09, 2020 Page (2) INSPECTION WORKSHEET (RPLUM-001210-2020) Checklist Item Status 5 psi or 10 ft. above highest conn. for 15 minutes Failed Pressure Test Failed Water Supply Piping Failed Air Head Failed 50 P.S.I for 15 minutes Failed Air Test Gas Piping 10 psi for 10 Minutes Failed All Return Air Hard Duct Work Failed Duct Insulation - if required in unheated spaces Failed Duct Testing Outside Conditioned Space Failed Duct work sealed properly Failed Mar 09, 2020 Page (3) Smith, Mark