Loading...
2007-479 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CE RT I F I CAT E ('".)AFE7 OCCUPANCY Permit Number. P20070479 Date Issued: Tuesday, September 09, 2008 This is to certify that work requested to be done as shown by Permit Number P20070479 has been completed. Location: 402 LUZERNE Rd Tax Map Number. 523400-308-011-0001-038-002-0000 Owner. TERRY BROWN Applicant: TERRY & CAROL BROWN This structure maybe occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the % property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070479 Application Number. A20070479 Tax Map No: 523400-308-011-0001-038-002-0000 Permission is hereby granted to: TERRY & CAROL BROWN For property located at: LUZERNE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: TERRY BROWN CAROL BROWN Fireplace 398 LUZERNE Rd Garage-2 Cars Attached Single Family Dwelling $120,000.00 QUEENSBURY,NY 12804-0000 Total value $120,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2007-479 Legal Address: 402 Luzerne Road 1852 SQ FT SINGLE FAMILY DWELLING& 576 SQ FT ATTACHED 2 CAR GARAGE & 1 FIREPLACE $279.84 PERMIT FEE PAID- THIS PERMIT EXPIRES: Sunday,August 17, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To r :7:7� F iada August 17, 2007 s SIGNED BY for the Town of Queensbury. Director of Building& de E orcement ---------0 PROJECT NAME r� 'I"l"'-OFFICE USE ONLY /� ; ; C-t JC. STAFF INITIALS: BUILDING PERMIT SUBMISSION DATE: CHECKLIST FOR: ' SINGLE FAMILY DWELLING 1. Building Permit Application Completed? YES NO N /A 2 Energy Form or CheckMate Energy Code Compliance Forms Complete? (2-copies) Energy Code Inspector's Report from Checkmate ---! a 3' Program? (2-copies) ! r 4 ; Septic application completely filled out? — — I (if applicable) I 5. Electrical Inspection Form complete? j 6. Two (2) sets of the plans each of the following: ? YES NO N /A { a. Floor plans (s)? 3 3 ' b. Foundation plan? i c. Cross sections (s)? V , 1 f i d. Elevations? V : e. Window and door schedule? V` I 11 g. Plans signed and sealed by registered architect or i l engineer? h. Window and door schedule? S _ ' j Two (2) site plans showing location of the structure to be 7. built, location of well or water lines, location of septic system or sewer line? 3 8. Setbacks from property lines to new structure? V� : 8 Setbacks to neighboring wells and septic systems, , _j including onsite well and septic systems (if applicable)? ! 3 ' j 9. 1 Driveway Permit? f ii Town of Queensbury- Community Development Office - 742 Buy Road,Queensbury, NY 12804 OFFICE USE ONLY f PROJECT NAME: , STAFF INITIALS: ; BUILDING PERMIT SUBMISSION DATE: CHECKLIST FOR: MULTIPLE DWELLING or COMMERCIAL PROJECTS I 1. Building Permit Application Completed? YES NO N /A 2. Energy Form or CheckMate Energy Code Compliance I jForms Complete? (2-copies) I , 3 Energy Code Inspector's Report from Checkmate — Program? (2-copies) 1 4 Septic application completely filled out? f (if applicable) f 5. 1 Electrical Inspection Form complete? f e 6. Two (2) sets of the plans each of the following: YES NO N /A I a. Floor plans (s)? b. Foundation plan? { c. Cross sections (s)? . 1 3 j i S f1 i i j d. Elevations? F _ e. Design loads including floor, snow load, and wind ' load? i f. Seismic design (required after January 2003)? i g. Plans signed and sealed by registered architect or ` f engineer? I ` S h. Window and door schedule? I I x Two (2) site plans showing location of the structure to be i built, location of well or water lines, location of septic7. j I ! system or sewer line with all setbacks and separation ► l distances shown, and all improvements to the property? ' ! 8. Solid Fuel Burning or Gas Appliance Form (if applicable)? i � 1 9. Driveway Permit Town of Queensbury- Community Development Office . 742 Bay Road, Queensbury, NY 121E Community Development Office 00 own of Queensbury • 742 Bay Road • Queensbury, New York •12804 01 + + ' • David Hatin, Director of Building&Codes ; Craig Brown,Zoning Administrator ; ' WINDOW SCHEDULE ' 1 JOB SITE/ADDRESS: � - C DATE: �a Q o OWNER: 2 2 /' (,J ",) APPLICATION NO.: WINDOW- UNIT OR CLEAR CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OR WINDOW SQ.FT. WIDTH OPENING SPECIAL HARDWARE OR MODEL/TYPE VENT MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER NAME CALL WIDTH HEIGHT OPENING INCHES S IN INSTRUCTIONS ON PLAN SIZE INCHES awa�ogr0 S„ � y 8 f 5 3� 4A6250,v Tw-11by 3'oi�8 `I`� „ 5% 3ro 6ej YL-3 � E2 (_oA) ag /7 - s Toil 7�7 ; loot' 7�7 B 26-LTR 11-05 %_______________________I 1 I I I I Commu Q nity Development Office e ; own of Queensbury • 742 Bay Road • Queensbury, New York •12804 / David Hatin, Director of Building&Codes I, Craig Brown, Zoning Administrator , I BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS REQUIRED ACTUAL ACTUAL LIGHT REQUIRED SQUARE FOOT HABITABLE ROOM AREA OF ROOM IN LIGHT , VENTILATION SQUARE FEET 8"%OF ROOM SQUARE VENTILATION- A SQUARE OPENING FOR REMARKS } ,ryL, AREA FOOTAGE //OF ROOM AREA / FOOTAGE yrEGR,eESS (L bon- .._ ....f'� / tl I C: �7 l: � r / i <7,..-,) ` q-�, �, U0 h,` f r ?? /C I l 1 �"l l {t , &7 I ( i '4! • K' ^'�, w' i :.t QUESTIONS? CALL 761-8256 OR EMAIL codesngueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION www.quensbury.net B 10-LTR 11-20 07 '17 Check Residential Plan Review: One& Two Family Dwellings Y/NIN/A (2)FulI sets of plans -Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: inflow Schedule With Glass Size Ll Door Schedule/Main Entrance 36"Door mergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. de,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor esidential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans oundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Yequired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors fairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise �a Spiral Not Allowed From 2nd Story S ke Detectors Battery Backup and Proper Location B oom Fixtures Proper Clearance all Width, 36"nun. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation ge Floor Sloped Attic Access oof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed ......,.,._.•....................................... --- r OFFICE USE ONLY ; --- -----I TAX MAP NO.( 1 PERMIT N0. FEES: PERMIT;27— RECREATION ENGINEERING (if applicable) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: Z-,elf- OWNER:"���-xl ADDRESS: O c t ADDRESS: PHONE NOS. �.��`- � �"� PHONE NOS. -�f�'` ;1,?-92? R CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: PHONE: LOCATION OF PROPERTY: 5 /Q SUBDIVISION NAME: 'l� 1�7��'C1 � � 741D PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p w LL Co APPLY TO YOUR z0 F- O (n cn U) E..:w PROJECT O 0-1 t w ¢ CL = v � o `�" o 0 mow ? z <a ¢ � � NU) OL � a = � LL / vz: SINGLE FAMILY 5a /g,5 0-� ! J TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL J ATTACHED GARAGE(1 63) OTHER 1 2� IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: V ESTIMATED CONSTRUCTION COST: I r____T o O FUEL TYPE: N p-:1�K 211 HEAT TYPE: ('fJndu'j HOW MANY FIREPLACE(S):I_AND/OR WOODSTOVES(S): ZONING CATEGORY: S I P� ARE THERE WETLANDS ON THIS SITE?_IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: L e f 6 d F- *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3_LGL 11-05 QTown of Queensbury a Community Development Office - 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? Fpe cknowledge no construction activities shall be commenced prior to issuance of a valid rmit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read agree to the above. Signed o «. Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: BUILDING & CODES APPROVAL ZONING APPROVAL01 , DATE DATE10 ; ; QUESTIONS? CALL 761-8256 OR EMAIL codes0gueensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.ciueensbury.net Operating Permit Issued: Yes No Occupancy Type: _ I Construction Classification: Assembly Occupancy Limit: Special Conditions: QT07vn of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 0 7 _/V7- --------------------- "Town ommunity Development Office of Queensbury - 742 Bay'Road - Queensbury, New York -12804 0 Date Stamp -David Hatin,Director of Building&Codes i Craig Brown,Zoning Administrator-Michael J. Palmer,Fire Marshal i ------------- APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS Application is hereby made to the Building &Codes Office for the issuance of a Building S,Use Permit pursuant to the New York State Fire Prevention 8,Building Code. The applicant or owner agrees to comply with all applicable laws,ordinances,regulations,and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED. OWNER: �q� ISe(7 &1 Al INSTALLERBUILDER: / I 12 fCe ATIft �✓� ADDRESS: /� K Z.E.E'N E "�' ADDRESS: � ap L u`L,6X U C IC PHONE NOS. SRO Q c PHONE NOS. ZF LOCATION OF PROPERTY: .C_. Le Z.E9,V6 Zd, SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: C[ z CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: STOVE FIREPLACE INSERT FIREPLACE,FACTORY BUILT* FIREPLACE,MASONRY FURNACE(GARAGE ONLY) *IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: Al dEC 46 MODEL NO. LISTED BY: NUMBER: QUESTIONS? CALL 761-8205 or 761-8206 j OR EMAIL: .' . firemarshalftmeensburv.net 7FLUE NRY•* CHECK ONEVISIT OUR WEBSITE FOR MORE INFORMATION www.ciueensbury.net 7. CHECK ONE ✓ CHIMNEY MATERIAL CHECK ONE ✓ **IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME:/t/0 0✓ MODEL NO. ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED INSPECTIONS. �rrrrr rrrrrrrrr_r_rrrr rrrrr.rrrrrrr r.____r________ OFFICE USE ONLY ---------- ' TAX MAP NO. PERMIT NO. PERMIT FEE ; ; 0 APPROVALS: ZONING TOWN CLERK_ ' _________________________ r__rrr___�____! APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER: a 5 7, g / INSTALLER: ADDRESS: ADDRESS: PHONE NOS. ` � Q- PHONE NOS. LOCATION OF INSTALLATION: L u ✓Z, � i'� d I.....-.............................-.......,................................................ ..................................... ...................,......,....... RESIDENCE INFORMATION NO.OF }• �... ^.., ..,, NC YEAR BUILT I X COMPUTATION= _ TOTAL DAILY FLOW �......BEDROOMS......1 ;:............. ...........a......................•......... GARBAGE � ;......................................_..............................................< E GRINDER I 1980 or older I ! X 1 150 gallon per bedroom i = INSTALLED? :......................................................... ...........4................................................... 1981 -1991 X 130 gallon per bedroom I = ».....................•.. ................. t...........;.................................... ..............................,..;...,.......«.........................,....,....... ' , / I 1992•present t........... .. X 110 gallon per bedroom = _ INSTALLED?, Ll16 T TUB .............._._......................._...............................................t............{..........................................................................i...........;...........�,..�..�...................................... PARCEL INFORMATION: ✓ TOPOGRAPHY: FLA ROLLING Ji STEEP SLOPE /oSLOPE ✓ SOIL NATURE: SAND �// LOAM CLAY OTHER ✓ GROUNDWATER: AT WHAT DEPTH? O BEDROCK/IMPERVIOUS MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL / WELL (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS ✓ PERCOLATION TEST: RATE IS ) PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub. ✓ SEPTIC TANK: 00 GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH FT. ✓ TOTAL SYSTEM LENGTH: --�00 FT. SEEPAGE PIT(S): HOW MANY? IVON6 ✓ SIZE OF EACH da _FT. X FT. ✓ SIZE OF STONE TO BE USED: # /DEPTH OR THICKNESS FT. ✓ BED SYSTEM SIZE: \'t X ¢ , ✓ ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE ✓ HOLDING TANK SYSTEM:(If required) NO. OF TANKS: /SIZE OF EACH ✓ GALLONS./TOTAL CAPACITY: GAL. ..............-...............................:.:...,.,.:.:.:.:.,...:.:...........:.................................:.,.:.............:.:.:.:.:.:.:.:.:.:.:.,.:.,.:.:.:.:.:.,.,.:.:.;.:.;.....:.,.:.:.,.,.,,..:.:.:.:.,.:.......................:.:.:.:.:,:.,. :.:.:.:.:.•.:.,.,.:.:.,.:.:.,.:.,.:.,.,.:...:.,.:.,.:.............,...:.,................ ,,.; NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. 1:..:................:.....:....:...........:.....................:.......................:.......:....................:.:...........:.::.::.:...............:.......:::..: :::....:.......................... ..:..... For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of QUESTIONS? CALL 761-8256 OR EMAIL Queensbury Sanitary Sewage Disposal Ordinance. codes@aueensbury net VISIT OUR WESSITE FOR MORE INFORMATION www.aueensbury.net Signatur t,of Person Responsible �'Dat Town cf Queensbury- Community Development Office - 742 Bay Road, Queensbury,NY 12804 Queensbury Building & Code Enforcement - ResideT#: spection Office No. (518)761-8256 Arrive: L ` ' — : ��" a f� Date Inspection request received: Inspector's Initial NAME: C�PtOI��LOCATION: — TYPE OF STRUCTURE: _h Fn Wnts• Yes X No 4" Building Number Address visible from road NO Chimney Height/"W Vent/Direct Vent Location VA Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brae / Ramqp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill (� , Gas Valve shut-off e /regulator 18 inches above �. \� v// Interior privacy/trim/doors l main entrance 36 inches )) v Bathroom/Ktcien watertight J Safety glazmg/Window in stairwells safety giazmg Interior Smoke Det3ctors/Carbon Monoa6�de Every level: V Every Bedrowk Outside every bedroom aye: ✓ Inter Connected: ✓ Batim backup: ✓ Attic access 30 inches x 22 indies x 30 indies in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft:150 sq.ft.vents Bathroom Fans,tf no window Plumbing fixtures Foundation insulation Floor truss,draft st finished basement 1,000 sq.ft Emergencyress below grade Gas Furnace shut-off within 30 feet or within fine of site lor Oil Furnace shut-off at entrance to furnace area FUmace/Hot Water Heater operating Low water shut-off boiler Relief Va s installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Dud work Seated property Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms 01 Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. In n Sticker Site Plan /Variance recored Flood Plain Certification,if required Okay to issue C/C or C/0 Tem nt LABuilding&Codes FormslBuilding&Codesllnspection FormAlkesidential Final Inspection Form revised_100405.doc;Revised January 7,2008 Queensbury Building & Code Enforcement - Resi(Wntial Final Inspection Office No. (518)761-8256 Arrive: b=c)D a Date Inspection request rece'ved: Inspector's Initials: NAME: �fJ LJ �� IT#: O LOCATION: e- Tl ;,-�r �- �... TE: - TYPE OF STRUCTURE: Comments: Yes No WA ,V Building Number Address visible from road Chimney Height/'B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches g� C) Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 indnes above grade {3C �,Zduta( Guard at stairwell at 34 inches or more VA _ L�p Guard at deck,porches 36 inches or more (�j ���ti �� IE Handrail Termination at Newell Post or Wall InteriorMAerior Railings 34 inches to 38 inches Deck Brad /Handkopped Ramp Compliant Vol Grade away from foundation 6 inches with 10 feet 1 eE 6 inch clearance to sal Gas Valve shut-off wposed/regulator 18 inches move grade Interior privacy/trim/doors/main entrance 36 inches l�i=EQl, No Bathroom/Kitchen watertight Safety glazing/Wffx"jT stairwells safety glazity L01.\ tJ O Interior Smoke /Carbon Monoxides Every level V Every BedrgA: Outside every bedroom a : Inter Corrected: ✓ Battery backup: ✓ "�� �,� ���� �� Attic access 30 inches x 22 inches x 30 inches in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft:150 sq.ft.vents 100, \-t:v Bathroom Fans,if no window Plumbing fixtures -77 Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. T Emergencybekrw grade V"o `dj c J� AP Gas Purace shut-off within 30 feet or within fine of site Oil Furnace shut-off at entrance to furnace area FumaceMot Water Heater owatmV VIA t3 \ f t Lk— Low water shut-off boiler D Relief Valve(s)installed/Heat Trap/Water T 110 R Enclosed Stairs Sheetrock Underside minimum W G (4C ONGE Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed property Gas Logs in Sealed or Glass Enclosure Final Electrical t D Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe QQN!ng As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Cerfificatkm,if recluked Okay to issue C/C or C 10 Tem /Permanent L•\Building&Codes Forms\Building&Codesllnspec ion FormMesidential Final inspection Form_revised_100405.doc;Revised January 7,2008 ' Final Survey .Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: �� —� NAME: (� G•__. LOCATION: QZ 0z'?,Gr -r- PERMIT#: `7 Final Survey Plot Plan AvDroved Denied The attached final survey has been received by the Dept.of .../ Community Development. Upon review the ,has been: MAP REFERENCE MAP OF A PROPOSED SUBDIVISION MADE FOR LAND5 N/F OF TERRY BROWN NIGHC�LSON 0:MKAGNRTIC AS pER ,gp XEFIs'RENCE BY: VAN DUSEN & STEVES DATED: MARCH 8, 2007 LAST REVISED: JULY 19, 2007 LOT I LAND5 N/F OF TOWN OF 1p QUEEN5BURY sos�2O"w W Z T- `� GRU5HED o STONE DRIVE LOT 2 AREA / 108,943.22 sq. ft. Gp 2.50 acres 1 1/2 STORY OOD FRAMED of HOUSE N I Ci 0�0 W NOB�7 800," E N —�_ LAND5 N/F OF NIAGARA MOHAWK POWER CORPORATION F. k - LAND Du Date, August 20, 2008 P BEARING A L LICENSED OR ADDITION TO A SURVEY SCale 1'-5O� & �- VIOL BEARS""�N 72 9ATW 'S SEAL A Map of a Survey made for VIOLATION OF sEcnDH 7zol.SUB-DIYNSWH z OF THE S e v s NEW YORIC STATE EWCO TW 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARL S MTH AN ORIGINAL IDME OF THE LAND SURVEYORS SEAL SHALL BE C0 70 BE VALID TRUE COPS' �CERTIFICATIONS INDICATED HEREON ,H"T Term' Brown S- 1 1WS SURVEY WAS PREPARED N AOOOROANCE WTH THE Lan d S L1 V e J o r S IN TING CODE a PRACTICE SO MOM ZONAL BY S NEE= STATE T*XA7MS S PL RUN ON Y IATW SURVEYORS SAID C1RiiFlCAl10N5 SHALL RUN ONLY TO THE PERSON FOR%MMI THE SURVEY IS PREPARED,AHD ON HIS BEHALF 70 THE'RILE COMPANY.GOVERNMENTAL 169 Haviland Road Queensbury, New York 12804 �'A S OF TW DJSV,UT.* VIVID Town of Queensbury, Warren County, New York SHEET I OF 1 (518) 792-8474 New York Lie. No. 50135 Brown C228G NO. DATE DESCRlPT10N DWG. NO. 070236,2 —38.2 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheirn,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL e" --) , f -? / ...*/ T -/ I.Cem 2 4575 Pennit No...4,,..' ................. Cut-in Card No..................................... Owner...........I ..........................................................................................................................* .......... Location...... ........ ......Ap................................ ...fX.......... ef�; <w—v I InstallationConsisting of...................................... ....................../....................................................... 0.............................................................................................................................................. .................................................................................................................................................................................... InstalledBy........S. ..........................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making t, t time, and if its rules are violated,the Company shall have the right to r - this Date......... ........... INSPECTOR............ ................... Tows of Qmeeaslury Fire MmAd 742 Bay Road Qmeasmbo",NY 12M 761-SM/76142A6 fax 7454437 Factory Built Gas Firealace/Stove Imnectioin Pimort Notice+New York State mgmm fiat aft UL Limted,factacy balk q*hamees be iced amwdig to the wdmcti and mpedficalioas cootaimed in the butanadom malonal a000mpam.. the appiam r-No deviati m from the waadacaseer's or specificatiom is allowed. prermAit# 'Puce At Pon anytime hupech R me (moo�"� Addr en L�fi o� L ✓z- X-^Xe P-D Rago Appgamm Mager Dimct vent Factory emit C'biumey Fine size Dmble WaM Triple Wan Immolated Yes I No N/A Coomads FI"r Protection Clearances to Combustibles(all sites) Fiirestep(s) vortical cum WAR Pc efcatiom Vent C earanos to CembustiMes 0 Vent/chimney Termination �(/C�NL C�ey bcgoit mast be 3 feet above rod ��, pardratia�2 feet above my coodu stMe nctiom fkbm 19 feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel witness operation Task Placement(d LP) WbW-BmIftg Dept. lVdIpw !ik-Fim b&u*A Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspe 'on request received: �'J Queensbury Building & Code Enforcement Arriv am/pp Depart. am/pm 742 Bay Road, Queensbury, NY 12804 Ins r' . Initials:_ NAME: �G�� PERMIT #: 0 7 — y7 LOCATION:_ I-� e�z.,�t�_.+�-� INSPECT ON: 0 0 TYPE OF STRUCTURE: Y ou h Plumbing Nail Plates jN ,au- �ML Plumbing Vent Vents in Place 1 /2 inch minimum Drain Size I Washing Machine Drain 2 inch minimum Cleanout every 100 feet chan a of direction 0Alr',/ . ure Test in / Vent Head S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping / Head 0 P.S.I for 15 minutes In lation Residential Check Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation y,, red unheated spaces ion Air Supply for Furnace k sealed properly / No duct to e nr616'h 4�1 COMMENTS: 0P or— ��}fj�. LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspecton request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's initials: Q L. NAME: irPdG�/� PERMIT #: 7' LOCATION: Lu2✓E INSPECT ON: r o TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Venter Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test >2 2- Water Supply Piping'` Air/ Head 0 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct-tape COMMENTS: LAPam Whiting\BuiWing&CodesVnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 �-// /Pr"4z-7 , Foundation Inspection Report Office No.(518)761-8256 Date Inspection pquest received: Queensbury Building&Code Enforcement Arriivve: t • ia�pm`1 t7 L Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: _ c NAME: PERMIT#: LOCATION: 4M:L L INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundatiow roofm Foun a oo In Footing m or ump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/ t 1 Found ion Infflu tion tenor/Exterior ' 1 R- \ _ Rough Gra drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspect. request received: Queensbury Building&Code Enforcement Arriv(/O- T am/p �epart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: _ fA NAME: /?-0&)/ PERMIT#: LOCATION: t U Z,6-re✓6� peb INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour ire wail 2, 3,4 hour Firestopping Grril'1( Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518)761-8256 Date In Cho quest received: ')Queensbury Building&Code Enforcement Arrive: ' -7- am/p, Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector s Initials. Cz-4- NAME: �� PERMIT#: LOCATION: zin2 INSPECT ON: 42- T E OF STRUCT Y N N/A COMMENTS V Framing HUO Attic Access 2 "x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall + /� Fire separation 1,2, 3 hour �` +�CC ' /t V , o p ire wal , ,4 h ur ��-- \C� �? 7 ! (�L�� (V 4p (r�� Firestopping 1f'Eo C<'�- Penetrat• ed 16 inch insulation in cavity min. Garage Fire Separation House side ''/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall ,.1 Windows Habitable Space/Bedrooms `,,A0- 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials NAME: PERMIT#: LOCATION: b INSPECT ON: / 7? c TYPE OF STRUCTURE: Y N , N/A COMMENTS Framing V Attic Access 22"x 30"minimum T Jack Studs/Headers `,� Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 `/z w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) I 20 in.(W) 5.7 sf above/below grade ! 5.0 sf grade _� Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/r Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspecto s Initials:vf NAME: ,oa/1A PERMIT NO.: 0 LOCATION: U C-Alf _ INSPECT ON: RECHEC ` Comments anal/or diagram Soil T Loam AClay Type of Water: units /Well Water Waterline seoLftn distAnce ft. Well separation dk&@p0ft. Other wells: ft. Abso tlon Field: Total lenO ft. Length of each trench d ft. Depth of trenches Size of Stone SeepM Pits: Number Size: x Stone Size: Piping Size Type Building to tank Z O Tank to Distribution Box " yIZ172- 5 Distribution Box to Fi Pit / n Opening Sealed: Y Partial �( End Ca Inlet/Outlet Pipes&Baffles Y N Location/ separations Foundation to tank ft. Foundation to absorption ft. Se ration of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N Location of Sy n Property: Front Rea Left Side fight 'de Middle Front Middle Rear System Use Status: proved Approved and needs to be re-inspected, please call the Building&Codes Office Disapproved Last revised 021006 Last revised 1/6/05 fir-- il,e)- -- Framing / Firestopping Inspection Report /. Office No. (518)761-8256 Date Inspecti ;equest received: 27 L'7 Queensbury Building&Code Enforcement Arrive V. am/pm part: am/pm 742 Bay Road, Queensbury,NY 12804 Inspecto 's Initials: NAME: PERMIT#: O LOCATION: B 1.✓ INSPECT ON: )7 TYPE OF STRUCTURE: r raining Y N NIA COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly t/�5 12"O.C. '�,4L rf. �,2 Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. �K ' Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 11/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade V\ YOUr- Vjay ; bl- ) F-)0 (T �J�-, Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Ins jengonWceQueensbury Building&Code Enforcement Arrive: a% 742 Bay Road, Queensbury,NY 12804 Inspector' NAME: Q / V PERMIT#: LOCATION: r n-e INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor s or less on center Ice and water shiel 4 inches from wall d44w—sapara4a<11, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report ° Office No.(518) 761-8256 Date Inspection r u re e' ed: Queensbury Building&Code Enforcement Arrive: e a 742 Bay Road,Queensbury,NY 12804 Inspector's Initia NAME: PERMIT#: — LOCATION: — INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers J Bracing/Bridging l Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall 1 Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping `` N, Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) i 5.7 sf above/below grade i 5.0 sf grade AU �r Framing / Firestopping Inspection Report Office No.(518) 761-8256 Date Ins ecti!pjequest received: 00 Queensbury Building&Code Enforcement Arrive: ??NNam/pm C De p rt: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector s Initials. NAME: PERMIT#: LOCATION: 14 261 _ INSPECT ON: Atil. cgej 7 TYPE OF STRUCT Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 1/z w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center ce and water shi—eN 24 inches from wall A-1 . Fire separation 1, 2, 3 hour /'ASr CY r 6L)4, — Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side `/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall `�� ��' 440-45 Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No.(518)761-8256 Date Inspection r u e Queensbury Building&Code Enforcement Arrive: epart: m 742 Bay Rd.,Queensbury,NY 12804 Inspector's NAME: E ERMIT#: 1 �_ LOCATION: t k) INSPECT ON: — TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspecdon Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 1-3 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials-6A,� NAME: Eri)� PERMIT#: �)�_ Z�7 LOCATION: INSPECT ON: — TYPE OF STRUC . Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width c s above footing 6 mil MY for wet areas under slab Backfill Ap6roval g Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Fonns\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM /0 Foundation Inspection Report Office No.(518)761-8256 Date In bon re e 'v : _ L> Queensbury Building&Code Enforcement Arrive: part: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi NAME: �Uu� P T#: d 7 —_L 7� LOCATION: '�� („>-r _� �' PECT ON: l� TYPE OF STRUCTURE: Comments Y N N/A ,'Footings Piers \�Wz ID Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM TMM of Quenub.iry Iraw dM armb l 742 Bay Bead Qmeeasbney,NY 12W4 761-SM/76141M fax 7454437 Factory Built Gas Fier W ace/Stove Inspection Report Kubota New Yogic Stale me"wes that all UL Imbed,&day ball apoa■ces be mdaved aocordimg to the wsbclioms and apecd*6-- omn combined in the Instaratim Manual aocootpanyiuv Nte appiaaoe.No deviation fhmn the aeaudadmetr's or Rmewwatiom is avowed. 11i 7 scwdoie hgNX iom :� fire M put amytbw c,r ►ppuamoe 11 factwer IM[Wd p Nred vent h'sctory now C7imey [ire Sine Doable Wav Trip)a Wav [undated Yes No N/A Co wmwmb floor Protection 3earanus to Combustibles(all sites) �'irestop(s) VeaticalOme WA PeaNnrtiou Vent Clearances to Combustibles Vent/Chimney Termmmtion Duey beig1k=ad be 3 feet above roof muebmUmn;2 feet above my co•lowdVle vustnctim Willett 10 feet Gas Shut-of Valve Combustion Air Hearth Extension Or any) Mantel MdgW Awe Up Witness operation Tank Placement Cif LP) Waite—»E Dolt, Yainw lieh—Fire Mataid 0�z — 1 7�- 7 REScheck Software Version 4.0.1 Compliance Certificate Project Title: BROWN RESIDENCE Report Date:07/14/07 Data filename:C:\Program Files\Check\REScheck\BROWN#595.rek Energy Code: New York State Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 16% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: Compliance:Passes Maximum UA:361 Your Home UA:327-->9.4%Better Than .. AssemblyGross Cavity Cont. Glazing UA D.. Perimeter U-Factor Ceiling 1:Flat Ceiling or Scissor Truss: 1852 38.0 0.0 56 Wall 1:Wood Frame,16"o.c.: 1584 21.0 0.0 75 Window 1:Wood Frame:Double Pane with Low-E: 57 0.340 19 Window 2:Wood Frame:Double Pane with Low-E: 29 0.340 10 Window 3:Wood Frame:Double Pane with Low-E: 44 0.340 15 Window 4:Wood Frame:Double Pane with Low-E: 9 0.340 3 Window 5:Wood Frame:Double Pane with Low-E: 11 0.340 4 Window 6:Wood Frame:Double Pane with Low-E: 14 0.340 5 Window 7:Wood Frame:Double Pane: 20 0.470 9 Door 1:Glass: 21 0.350 7 Door 2:Glass: 7 0.350 2 Door 3:Solid: 21 0.170 4 Door 4:Glass: 40 0.330 13 Basement Wall 1:Wood Frame: 1744 13.0 0.0 105 Wail height:8.9' Depth below grade:6.5' Insulation depth:8.9' The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Name-'Title Signature Date Project Notes: ' CUSTOM TWO BEDROOM HOME Al .... ._._.,_...,.,. ._ __v.:_z.,.. ' ...___.. i yT BROWN RESIDENCE Page 1 of 5 V f CREScheck Software Version 4.0.1 NJ( Inspection Checklist Date:07/14/07 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Wood Frame,8.9'ht/6.5'bg/8.9 insul,R-13.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Wood Frame:Double Pane with Low-E,U-factor.0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled Ufactors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 4:Wood Frame:Double Pane with Low-E,U-factor,0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 5:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?_Yes No Comments: ❑ Window 6:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes—No Comments: ❑Window 7:Wood Frame:Double Pane,U factor:0.470 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?,Yes—_ _No Comments: Doors: BROWN RESIDENCE Page 2 of 5 ❑ Door 1:Glass,U-factor:0.350 Comments: ❑ Door 2:Glass,U-factor:0.350 Comments: ❑ Door 3:Solid,U-factor:0.170 Comments: ❑ Door 4:Glass,U-factor:0.330 Comments: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building are insulated to R-6. ❑ Supply ducts in unconditioned spaces are insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric, or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters exist for each dwelling unit. Fireplaces: ❑ Fireplaces are installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. BROWN RESIDENCE Page 3 of 5 Y Swimming Pools: 0 Al heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. BROWN RESIDENCE '�-� Page 4 of 5 • Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature("F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes ange]°F) Piping System Types R Temp. 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" an Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) BROWN RESIDENCE Page 5 of 5