Loading...
CC-0080-2020(i Office Use Only PRINCIPLE STRUCTURE PERM=|pormity:CC-00®9 2O%S APPLICATION Permit Fee:$_}2AR4S *Rec.Fee:§,eoInvoices240'oTownofQueensbury 742 Bay Road,Queensbury,NV 2804 P:§18-761-8256 www queensbury net Project Location: |A4O4 Ciptt,VouTe Tax Map #:ZOd-\2-\2\Subdivision Name:NA 2 [n\ TOWN BD.RESOLUTION 86-2013:$850 recreation fee for new dw ing units:single family.duple> . two-family, muttiplefamiy,apartments,condominiums,townhouses,andor manufactur me {re mobile homes.This is in addition to the permit fee(s)I Fest 039 ns CONTACT INFORMATION. ©Applicant: Name(s):¥Awliig Vente Mailing Address,C/SiZ:}4@A<srBNEVouns 4,QueENSiouey NY |2@04- Cell Ph:TAo-1042_Land Line:() Email:_a\¢ Fenn as |Com »Primary Owner(s): Name(s):oweSTATEPoutAUC Mating Address,CISIZ: HetSosfours 4,Quaaseuer NY 1204 Cell WP Rr (AZ Land Line:() Email:i ibaany@ mail:com «Contractor(s) Name(s):Barewoenk+Gon EXCAVATING Mailing Address,C/S/Z: 19202Vout149,Fer ANN NYY 12627 Cell Ph.)Land Line:(61 )19Z-42Z4@ Email:u \th excavating.com .archite®[s)/Engineer(s): Name(s):AACINSYA Vin APUbITEtTULCE Mailing Address,C/SiZ:[4Dix. AVE, Glens faws NY 1Zdol Cell Ph.:(A®Land Line:(QB)Al-0266 Email ephallenucag.mr.CoM Contact Person for Building &Code Compliance: Cell #.:phate Line:(G16):Email Principle Structure Applicaton Revised January 2019 PROJECT INFORMATION: TYPE:Commercial Cl Residential WORK CLASS: Ci Single-family CO Two-family C Multi-family (#of units:_) C1 Townhouse 1 Business Office Aretai C0 Hotel/Motel Ci Industria/Warehouse (]Garage (#of cars __)Ci Other (describe __) STRUCTURE SQUARE FOOTAGE:GARAGE SQUARE FOOTAGE: 1"floor:A,ZO8SE 1"floor: 2"floor:2°floor: 3 floor:Total square feet: Basement (habitable space): Total square feet:4,26%SE_ ADDITIONAL PROJECT INFORMATION: 1.Estimated Costof Construction:$G0»,00D 2.Proposed use of the building:__ESS 3.If Commercial or Industrial,indicate the name of the business:_“TR> 4,Source of Heat:WGas Doil Cipropane (solar Llother: (Fireplaces need a separate Fuel Burning Appliances &Chimney Application,one per appliance) 5.Are there any structures not shown on the plot plan?Ives (#KO Explain:__ 6.Are there any easements on the property?CIYES mo 7.SITE INFORMATION: a.What is the dimensions or acreage of the parcel?An Mes b.Is this a corner lot?Oyes no c.Will the grade be changed as a result of the construction?—-Clves.(N10 d.What is the water source?PUBLIC COPRIVATE COWELL e.Is the parcel on SEWER or a PRIVATE SEPTIC system?EAWtae— Principle Structure Application Revised January 2019, DECLARATION: |.lacknowledge that no construction shall commence prior to issuance of a valid building permit and work will be completed within a 12 month period 2,Ifthe work is not completed by the tyear expiration date the permit may be renewed subject to fees and department approval. 3.I certify that the application,plans and supporting materials are a true and complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with local zoning regulations. 4.|acknowledge that prior to occupying the facilities proposed I,or my agents,willobtain a certificate of occupancy 5.|understand that live are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities priorto issuance ofa certificate of occupancy. |have read and agree to the above: PRINT NAME:Ulaerel Ka very SIGNATURE:DATE:ABzeco Principle Structure Application Revised January 2019 NfiCOMcheck Software Version 4.1.1.0 l Envelope Compliance Certificate Project Information Energy Code: 2015 IECC FILE COpy Project Title: New Retail Facility Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Vertical Glazing/Wall Area: 19% Construction Site: Owner/Agent: Designer/Contractor: 1454 State Route 9 David Kenny Ethan P. Hall Queensbury, NY 12804 Adirondack Outlet Mall Rucinski Hall Architecture 1454 State Route 9 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0274 Additional Efficiency Package(s) ephall!@nycap.rr.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Building Area Floor Area 1-Retail : Nonresidential 4258 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(.) Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Retail] 4258 38.0 0.0 0.027 0.021 Basement Wall 1:Solid Concrete:12"Thickness,Normal Density, 354 -- 15.0 0.060 0.108 Furring:None,Wall Ht 5.9,Depth B.G.5.5,[Bldg.Use 1 -Retail] Basement Wall 2:Solid Concrete:12"Thickness,Normal Density, 413 -- 15.0 0.060 0.108 Furring:None,Wall Ht 5.9,Depth B.G.5.5,[Bldg.Use 1 -Retail] Basement Wall 3:Solid Concrete:12"Thickness,Normal Density, 354 -- 15.0 0.060 0.108 Furring:None,Wall Ht 5.9,Depth B.G.5.5,[Bldg.Use 1 -Retail] Basement Wall 4:Solid Concrete:12"Thickness,Normal Density, 413 -- 15.0 0.060 0.108 Furring:None,Wall Ht 5.9,Depth B.G.5.5,[Bldg.Use 1 -Retail] NORTH Exterior Wall 4:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Retail] 1050 30.0 0.0 0.053 0.051 Window 2:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 80 -- -- 0.320 0.360 Product ID product label,SHGC 0.33,[Bldg.Use 1 -Retail](b) Window 3:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 105 -- -- 0.320 0.360 Product ID product label,SHGC 0.33,[Bldg.Use 1 -Retail](b) EAST Exterior Wall 3:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Retail] 900 30.0 0.0 0.053 0.051 Door 2:Insulated Metal,Swinging,[Bldg.Use 1 -Retail] 21 -- -- 0.300 0.370 Door 3:Insulated Metal,Swinging,[Bldg.Use 1 -Retail] 25 -- --- 0.300 0.370 Door 4:Insulated Metal,Swinging,[Bldg.Use 1 -Retail] 25 -- -- 0.300 0.370 SOUTH Exterior Wall 2:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Retail] 1050 30.0 0.0 0.053 0.051 Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 1 of 20 Drawings\Kenny-AOM-Star.cck Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor,.) Perimeter WEST Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Retail] 900 30.0 0.0 0.053 0.051 Window 1:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 565 -- -- 0.320 0.360 Product ID product label,SHGC 0.33,[Bldg.Use 1 -Retail](b) Door 1:Insulated Metal,Swinging,[Bldg.Use 1 -Retail] 42 -- -- 0.320 0.370 (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. Envelope PASSES: Design 11% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 a d to comply with any applicable mandatory requirements listed in the Inspection Checklist. 44•01 20Z0 Ethan P. Hall-Architects Name-Title Sign e Date Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 2 of 20 Drawings\Kenny-AOM-Star.cck • COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: New Retail Facility Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 1454 State Route 9 David Kenny Ethan P. Hall Queensbury, NY 12804 Adirondack Outlet Mall Rucinski Hall Architecture 1454 State Route 9 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0274 Additional Efficiency Package(s) ephall!@nycap.rr.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Retail:Sales Area 4200 1.43 6006 Total Allowed Watts= 6006 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp I Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Retail:Sales Area LED 1:LED Linear 22W: 1 10 34 340 Total Proposed Watts= 340 Interior Lighting PASSES: Design 94% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck ersion 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist.Ethan P. Hall-Architect 1/y� l iV e Name-Title Si nature Date Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 3 of 20 Drawings\Kenny-AOM-Star.cck COMcheck Software Version 4.1.1.0 - ril Nfil Exterior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: New Retail Facility Project Type: New Construction Exterior Lighting Zone 4(High activity metropolitan commercial district) Construction Site: Owner/Agent: Designer/Contractor: 1454 State Route 9 David Kenny Ethan P. Hall Queensbury, NY 12804 Adirondack Outlet Mall Rucinski Hall Architecture 1454 State Route 9 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0274 ephall!@nycap.rr.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Entry canopy 1 ft2 0.4 Yes 0 Entry canopy 1 ft2 0.4 Yes 0 Entry canopy 1 ft2 0.4 Yes 0 Entry canopy 1 ft2 0.4 Yes 0 Total Tradable Watts(a)= 2 Total Allowed Watts= 2 Total Allowed Supplemental Watts(b)= 1300 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description I Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Entry canopy(1 ft2):Tradable Wattage LED 1:LED PAR 13W: 1 7 32 224 LED 2:LED PAR 13W: 1 1 32 32 LED 3:LED PAR 13W: 1 1 32 32 LED 4:LED PAR 13W: 1 1 32 32 Total Tradable Proposed Watts= 320 Exterior Lighting PASSES: Design 75% better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 4 of 20 Drawings\Kenny-AOM-Star.cck Ethan P. Hall-Architect !Z refo gaze. Name-Title Sig ure Date Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 5 of 20 Drawings\Kenny-AOM-Star.cck NfiCOMcheck Software Version 4.1.1.0 i r Mechanical Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: New Retail Facility Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 1454 State Route 9 David Kenny Ethan P. Hall Queensbury, NY 12804 Adirondack Outlet Mall Rucinski Hall Architecture 1454 State Route 9 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-741-0274 Additional Efficiency Package(s) ephall!@nycap.rr.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=65 kBtu/h Proposed Efficiency=90.00%Et,Required Efficiency: 80.00%Et or 78%AFUE Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 —Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV,1200 CFM,0.5 motor nameplate hp,91.0 fan efficiency grade 1 HVAC System 2(Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=65 kBtu/h Proposed Efficiency=90.00%Et,Required Efficiency: 80.00%Et or 78%AFUE Cooling: 1 each-Field-Assembled DX System,Capacity=45 kBtu/h,Air-Cooled Condenser,Air Economizer No minimum efficiency requirement applies Fan System: FAN SYSTEM 1 —Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Single-Zone VAV, 1200 CFM,0.5 motor nameplate hp,91.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck - sion 4. .1.0 a d to comply with any applicable mandatory requirements listed in the Inspection Checklist. / / a, Ethan P. Hall-Architect 2Z MB 2oZo Name Title S • ure Date Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 6 of 20 Drawings\Kenny-AOM-Star.cck • COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all DComplies Requirement will be met. [PR1]1 information with which compliance ❑Does Not can be determined for the building ❑Not Observable Location on plans/spec:A-1 envelope and document where exceptions to the standard are ❑Not Applicable claimed. C103.2 Plans, specifications,and/or ❑Complies Requirement will be met. (PR2]1 calculations provide all information DDoes Not with which compliance can be [Not Observable Location on plans/spec:A-1 determined for the mechanical systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR4]1 calculations provide all information ❑Does Not with which compliance can be ['Not Observable Location on plans/spec: A-1 determined for the interior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. C103.2 Plans, specifications, and/or ❑Complies Requirement will be met. [PR8]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable Location on plans/spec:A-1 determined for the exterior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C402.4.1 The vertical fenestration area <= 30 ❑Complies Requirement will be met. [PR10]1 percent of the gross above-grade wall ❑Does Not area. Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C402.4.1 The skylight area <= 3 percent of the ❑Complies Requirement will be met. [PR11]1 gross roof area. ❑Does Not ENot Observable Location on plans/spec: A-1 ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 1 3 Low Impact(Tier 3) ' Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 7 of 20 Drawings\Kenny-AOM-Star.cck Section Plan Review Complies? Comments/Assumptions & Req.ID C406 Plans, specifications,and/or ❑Complies Requirement will be met. [PR9]1 calculations provide all information DDoes Not with which compliance can be ENot Observable Location on plans/spec:A-1 determined for the additional energy efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 12 I Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 8 of 20 Drawings\Kenny-AOM-Star.cck Section Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID --- C303.2 Below-grade wall insulation installed DComplies Requirement will be met. [FO2]2 per manufacturer's instructions. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C303.2.1 Exterior insulation protected against DComplies Requirement will be met. [FO6]1 damage, sunlight, moisture,wind, ❑Does Not landscaping and equipment maintenance activities. Not Observable ❑Not Applicable C402.1.4 Below-grade wall insulation R-value. DComplies See the Envelope Assemblies table for values. [F01]2 ❑Does Not ❑Not Observable ❑Not Applicable C403.2.4. Snow/ice melting system sensors for DComplies Exception: Requirement does not apply. 5, future connection to controls. Freeze ❑Does Not C403.2.4. protection systems have automatic 6 controls installed. ['Not Observable [FO9]3 ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 !Medium Impact(Tier 2) 3 Low Impact(Tier 3) J Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 9 of 20 Drawings\Kenny-AOM-Star.cck Section # Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 Fenestration products rated in ❑Complies Requirement will be met. [FR12]2 accordance with NFRC. ['Does Not ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C303.1.3 Fenestration products are certified as ❑Complies Requirement will be met. [FR13]1 to performance labels or certificates ❑Does Not provided. Location on plans/spec:A-1 ❑Not Observable ❑Not Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 EDoes Not ❑Not Observable ❑Not Applicable C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. ❑Does Not 4 [FR8]1 ❑Not Observable ❑Not Applicable C402.4.4 U-factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ❑Does Not meets requirements. ❑Not Observable ONot Applicable C402.5.7 Vestibules are installed on all building OComplies Exception: Requirement does not apply. [FR17]3 entrances. Doors have self-closing ❑Does Not devices. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 10 of 20 Drawings\Kenny-AOM-Star.cck Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms ❑Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume ['Does Not C404.5.2 requirements. Refer to section details. Not Observable (PL6]3 ONot Applicable C404.5, Heated water supply piping conforms ❑Complies Exception: Requirement does not apply. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. Not Observable [PL6]3 ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating :Not Observable cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply. [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating :Not Observable cycle. ENot Applicable C404.7 Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a [Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a [Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 11 of 20 Drawings\Kenny-AOM-Star.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Re..ID C402.2.6 Thermally ineffective panel surfaces of❑Complies Exception: Requirement does not apply. [ME41]3 sensible heating panels have ODoes Not insulation >= R-3.5. plot Observable ONot Applicable C402.5.5, Stair and elevator shaft vents have ❑Complies Exception: Requirement does not apply. C403.2.4. motorized dampers that automatically ODoes Not [ME3]3 close. ONot Observable ONot Applicable C402.5.5, Outdoor air and exhaust systems have ❑Complies Requirement will be met. C403.2.4. motorized dampers that automatically ODoes Not 3 shut when not in use and meet [Not Observable Location on plans/spec:A-1 [ME58]3 maximum leakage rates.Check gravity dampers where allowed. ONot Applicable C403.2.13 Unenclosed spaces that are heated ❑Complies Exception: Requirement does not apply. [ME71]2 use only radiant heat. ODoes Not ['Not Observable ONot Applicable C403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. [ME55]2 ❑Does Not ONot Observable ONot Applicable C403.2.6. Demand control ventilation provided ❑Complies Exception: Requirement does not apply. 1 for spaces>500 ft2 and >25 ODoes Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side ONot Observable economizer, auto modulating outside ONot Applicable air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation ❑Complies Exception: Requirement does not apply. 2 has automatic contaminant detection ODoes Not [ME115]3 and capacity to stage or modulate ONot Observable fans to 50%or less of design capacity. ❑Not Applicable C403.2.7 Exhaust air energy recovery on ❑Complies Requirement will be met. [ME57)1 systems meeting Table C403.2.7(1) ODoes Not and C403.2.7(2). ❑Not Observable ONot Applicable C403.2.8 Kitchen exhaust systems comply with ❑Complies Exception: Requirement does not apply. [ME116)3 replacement air and conditioned ODoes Not supply air limitations, and satisfy hood rating requirements and maximum ONot Observable exhaust rate criteria. ONot Applicable C403.2.9 HVAC ducts and plenums insulated. ❑Complies Exception: Requirement does not apply. [ME60]2 Where ducts or plenums are installed ODoes Not in or under a slab,verification may need to occur during Foundation :Not Observable Inspection. ONot Applicable C403.2.9 Ducts and plenums sealed based on ❑Complies Requirement will be met. [ME10]2 static pressure and location. ODoes Not DNot Observable Location on plans/spec:A-1 ONot Applicable C403.2.9. Ductwork operating >3 in.water ❑Complies Exception: Requirement does not apply. 1.3 column requires air leakage testing. ODoes Not [ME11]3 ❑Not Observable ONot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 12 of 20 Drawings\Kenny-AOM-Star.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Reg.ID C403.2.9. Ductwork operating >3 in.water ❑Complies Exception: Requirement does not apply. 1.3 column requires air leakage testing. ❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies Exception: Requirement does not apply. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. See the Mechanical Systems list for values. ❑Not Observable ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies Exception: Requirement does not apply. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ONot Observable See the Mechanical Systems list for values. ❑Not Applicable C408.2.2. Air outlets and zone terminal devices ❑Complies Requirement will be met. 1 have means for air balancing. ❑Does Not [ME53]3 ['Not Observable ❑Not Applicable C403.5, Refrigerated display cases, walk-in DComplies Exception: Requirement does not apply. C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote [ME123]3 condensers not located in a ❑Not Observable condensing unit, have fan-powered ❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 13 of 20 Drawings\Kenny-AOM-Star.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met. [EL15]1 reduce the lighting load by at least ❑Does Not 50%. Location on plans/spec:A-1 DNot Observable ONot Applicable C405.2.1 Occupancy sensors installed in ❑Complies Requirement will be met. [EL18]1 required spaces. ❑Does Not ONot Observable Location on plans/spec:A-1 DNot Applicable C405.2.1, Independent lighting controls installed ❑Complies Requirement will be met. C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and ONot Observable Location on plans/spec:A-1 [EL23]2 visible to occupants. ONot Applicable C405.2.2. Automatic controls to shut off all ❑Complies Requirement will be met. 1 building lighting installed in all ❑Does Not [EL22]2 buildings. Location on plans/spec:A-1 ['Not Observable ONot Applicable C405.2.3 Daylight zones provided with OComplies Exception: Requirement does not apply. [EL16]2 individual controls that control the ODoes Not lights independent of general area lighting. DNot Observable DNot Applicable C405.2.3, Primary sidelighted areas are ❑Complies Exception: Requirement does not apply. C405.2.3. equipped with required lighting ❑Does Not 1, controls. ONot Observable C405.2.3. 2 ENot Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ❑Complies Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors ❑Does Not 1, are equipped with required lighting C405.2.3. controls. ONot Observable 3 ONot Applicable [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. Location on plans/spec:A-1 DNot Observable ENot Applicable C405.2.4 Additional interior lighting power ❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is :Not Observable Location on plans/spec: A-1 automatically controlled and separated from general lighting. ['Not Applicable C405.2.5 Automatic lighting controls for exterior ❑Complies Exception: Requirement does not apply. [EL25]na0 lighting installed.Controls will be ❑Does Not daylight controlled, set based on business operation time-of-day, or DNot Observable reduce connected lighting > 30%. ONot Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies Requirement will be met. [EL6]1 face. ❑Does Not ONot Observable Location on plans/spec:A-1 ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 12 I Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 14 of 20 Drawings\Kenny-AOM-Star.cck 1 High Impact(Tier 1) 12 Medium Impact(Tier 2) 3 Low Impact(Tier 3) ] Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 15 of 20 Drawings\Kenny-AOM-Star.cck Section # Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 Roof insulation installed per ❑Complies Requirement will be met. [IN3)1 manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed ONot Observable Location on plans/spec:A-1 only where the roof slope is <=3 in 12. ONot Applicable C303.1 Building envelope insulation is labeled ❑Complies Requirement will be met. [IN10]2 with R-value or insulation certificate ❑Does Not providing R-value and other relevant data. ONot Observable ❑Not Applicable C303.2 Above-grade wall insulation installed ❑Complies Requirement will be met. [IN7]1 per manufacturer's instructions. ❑Does Not pilot Observable Location on plans/spec:A-1 ❑Not Applicable C303.2.1 Exterior insulation is protected from ❑Complies Exception: Requirement does not apply. [IN14]2 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during ONot Observable Foundation Inspection. ONot Applicable C402.2.1 Insulation intended to meet the roof EComplies Requirement will be met. [IN17]3 insulation requirements cannot be EDoes Not installed on top of a suspended Location on plans/spec:A-1 ceiling. Mark this requirement compliant if insulation is installed ONot Applicable accordingly. C402.2.3 Above-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values. [IN6]1 ❑Does Not ONot Observable ONot Applicable C402.2.6 Radiant panels and associated ❑Complies Exception: Requirement does not apply. [IN18]3 components,designed for heat ❑Does Not transfer from the panel surfaces to the occupants or indoor space are ENot Observable insulated with a minimum of R-3.5. ENot Applicable C402.2.2 Roof R-value. For some ceiling ❑Complies See the Envelope Assemblies table for values. [IN2]1 systems,verification may need to ❑Does Not occur during Framing Inspection. ENot Observable ONot Applicable C402.5.1. All sources of air leakage in the ❑Complies Requirement will be met. 1 building thermal envelope are sealed, DDoes Not [IN1]1 caulked, gasketed,weather stripped ❑Not Observable Location on plans/spec:A-1 or wrapped with moisture vapor- permeable wrapping material to ❑Not Applicable minimize air leakage. Additional Comments/Assumptions: 1 I High Impact(Tier 1) 12 I Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 16 of 20 Drawings\Kenny-AOM-Star.cck • Section Final Inspection Complies? Comments/Assumptions & Reg.ID C303.3, Furnished O&M instructions for ❑Complies Requirement will be met. C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated Not Observable [FI17]3 representative. ❑ ONot Applicable C303.3, Furnished O&M manuals for HVAC ❑Complies Requirement will be met. C408.2.5. systems within 90 days of system ❑Does Not 3 3 acceptance. ['Not Observable [FI8] ONot Applicable C402.5 Building envelope contains a ❑Complies Requirement will be met. [F155]1 continuous air barrier that has been ❑Does Not tested and deemed to limit air leakage ONot Observable Location on plans/spec:A-1 <=0.40 cfm/ft2. ONot Applicable C402.5.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [F137]1 dock cargo doors. EDoes Not [Not Observable ONot Applicable C403.2.2 HVAC systems and equipment OComplies Requirement will be met. [F127]3 capacity does not exceed calculated ❑Does Not loads. Location on plans/spec:A-1 ONot Observable ONot Applicable C403.2.4. Heating and cooling to each zone is ❑Complies Requirement will be met. 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device ONot Observable Location on plans/spec: A-1 per installed humidification/dehumidification ONot Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies Requirement will be met. 1 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device ❑Not Observable Location on plans/spec:A-1 per installed humidification/dehumidification ❑Not Applicable system. C403.2.4. Thermostatic controls have a 5 °F ❑Complies Requirement will be met. 1.2 deadband. ❑Does Not [F138]3 ONot Observable Location on plans/spec: A-1 ElNot Applicable C403.2.4. Temperature controls have setpoint ❑Complies Requirement will be met. 1.3 overlap restrictions. ❑Does Not [F120]3 ONot Observable Location on plans/spec:A-1 ONot Applicable C403.2.4. Each zone equipped with setback ❑Complies Exception: Requirement does not apply. 2 controls using automatic time clock or ❑Does Not [F139]3 programmable control system. ONot Observable ONot Applicable C403.2.4. Automatic Controls: Setback to 55°F ❑Complies Exception: Requirement does not apply. 2.1, (heat)and 85°F (cool); 7-day clock, 2- ❑Does Not C403.2.4. hour occupant override, 10-hour 2.2 backup ['Not Observable [F140]3 ONot Applicable C403.2.4. Systems include optimum start ❑Complies Exception: Requirement does not apply. 2.3 controls. ❑Does Not [F141]3 ['Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 I Low Impact(Tier 3) J Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 17 of 20 Drawings\Kenny-AOM-Star.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. Systems include optimum start ❑Complies Exception: Requirement does not apply. 2.3 controls. DDoes Not [FI41]3 DNot Observable DNot Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts [Not Observable are less than or equal to allowed LJNot Applicable watts. C405.5.1 Exterior lighting power is consistent DComplies See the Exterior Lighting fixture schedule for values. [FI19]1 with what is shown on the approved ODoes Not lighting plans, demonstrating proposed watts are less than or equal ['Not Observable to allowed watts. Observable,__, Applicable C408.2.1 Commissioning plan developed by DComplies Requirement will be met. [FI28]1 registered design professional or ODoes Not approved agency. Location on plans/spec:A-1 ['Not Observable DNot Applicable C408.2.3. HVAC equipment has been tested to DComplies Exception: Unitary or packaged HVAC eqiupment without 1 ensure proper operation. ODoes Not supply air economizers. (FI31]1 ONot Observable DNot Applicable C408.2.3. HVAC control systems have been DComplies Requirement will be met. 2 tested to ensure proper operation, ODoes Not [FI10]1 calibration and adjustment of controls. [Not Observable Location on plans/spec: A-1 DNot Applicable C408.2.4 Preliminary commissioning report DComplies Requirement will be met. [FI29]1 completed and certified by registered ODoes Not design professional or approved ❑Not Observable Location on plans/spec:A-1 agency. DNot Applicable C408.2.5. Furnished HVAC as-built drawings DComplies Requirement will be met. 1 submitted within 90 days of system ODoes Not [FI7]3 acceptance. Pilot Observable DNot Applicable C408.2.5. Furnished as-built drawings for DComplies Requirement will be met. 1 electric power systems within 90 days ODoes Not [FI16]3 of system acceptance. [Not Observable DNot Applicable C408.2.5. An air and/or hydronic system DComplies Requirement will be met. 3 balancing report is provided for HVAC ODoes Not [FI43]1 systems. Location on plans/spec:A-1 ENot Observable ❑Not Applicable C408.2.5. Final commissioning report due to ❑Complies Requirement will be met. 4 building owner within 90 days of ODoes Not [F130)1 receipt of certificate of occupancy. ❑Not Observable Location on plans/spec: A-1 ENot Applicable C408.3 Lighting systems have been tested to ❑Complies Requirement will be met. [F133]1 ensure proper calibration, adjustment, ODoes Not programming, and operation. ['Not Observable Location on plans/spec:A-1 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) j 2 !Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 18 of 20 Drawings\Kenny-AOM-Star.cck 1 High Impact(Tier 1) 12 !Medium Impact(Tier 2) 3 Low Impact(Tier 3) J Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet MaII\Starbucks Information\Construction Page 19 of 20 Drawings\Kenny-AOM-Star.cck Project Title: New Retail Facility Report date: 02/21/20 Data filename: Y:\Kenny Developments\Adirondack Outlet Mall\Starbucks Information\Construction Page 20 of 20 Drawings\Kenny-AOM-Star.cck 288.12-1-21 CC-0080-2020 Statement of Special Inspections 1454 State Rte 9 LLC 1454 State Rte 9 New Commercial Bldg 4258 s.f. rA5iCouncil of American Structural Engineers U Project: New Building for Adirondack Outlet Mall Location: 1454 State Route 9, Queensbury, NY FEB 24 ?0?0 Owner: TOWN OF C±UEENSBURY Owner's Address: FILE. COPY BUILDING&CODES Design Professional in Responsible Charge: SB Engineering, PLLC 900 Route 146, Clifton Park, NY Architect of Record: Rucinski Hall Architecture, 134 Dix Avenue, Glens Falls, NY 12801 This Statement of Special Inspections is submitted as a condition for permit issuance in accordance with the Special Inspection and Structural Testing requirements of the Building Code. It includes a schedule of Special Inspection services applicable to this project as well as the name of the Special Inspection Coordinator and the identity of other approved agencies to be retained for conducting these inspections and tests. This Statement of Special Inspections encom ass the following disciplines: Structural j Mechanical/Electrical/Plumbing ❑ Architectural ❑ Other: The Special Inspector shall keep records of all inspections and shall furnish inspection reports to the Building Official and the Registered Design Professional in Responsible Charge. Discovered discrepancies shall be brought to the immediate attention of the Contractor for correction. If such discrepancies are not corrected, the discrepancies shall be brought to the attention of the Building Official and the Registered Design Professional in Responsible Charge. The Special Inspection program does not relieve the Contractor of his or her responsibilities. Interim reports shall be submitted to the Building Official and the Registered Design Professional in Responsible Charge. A Final Report of Special Inspections documenting completion of all required Special Inspections, testing and correction of any discrepancies noted in the inspections shall be submitted prior to issuance of a Certificate of Use and Occupancy. This document shall be prepared and signed by the licensed Design Professional acting as the Special Inspector. Job site safety and means and methods of construction are solely the responsibility of the Contractor. Interim Report Frequency: Monthly or❑ per attached schedule. Prepared by: ��OF NElNY BUR O Scott E. Burlingame � ',\ L�tic,+ ,.� (type or print name) * °o Y E 2/21/2020 ±Ii1PL •�_ BOA 085186 Signature Date RpFESSICP' Design I Seal Owner's Authorization: Building Official's Acceptance: Signature Date Signature Date CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Sheet 2 of 10 Project: Adirondack Outlet Mall Schedule of Inspection and Testing Agencies Statement of Special Inspections includes the following building systems: ® Soils and Foundations ❑ Prefabricated Wall Panels ® Cast-in-Place Concrete ❑ Spray Fire Resistant Material ❑ Precast Concrete ® Wood Construction ❑ Shotcrete ® Prefabricated Wood Trusses ❑ Masonry Level 1 ❑ Exterior Insulation and Finish System ❑ Masonry Level 2 ❑ Mechanical & Electrical Systems ® Structural Steel ❑ Architectural Systems ® Cold-Formed Steel Framing ❑ Special Cases ❑ Prefabricated Cold-Formed Trusses Special Inspection Agencies I Firm I Address,Telephone 1. Special Inspector To be determined and hired by owner. 2 Testing Laboratory SIB Services,Inc PO Box 2199 -pre-approved list. Ballston Spa,NY 12020 518-899-7491 Trans Tech QCQA Laboratories 1594 State St. Schenectady,NY 12304 518-372-4067 Terracon 594 Broadway Watervliet,NY 12189 518-266-0310 3 Geotechnical Engineer Note: The inspection and testing agent shall be engaged by the Owner or the Owner's Agent, and not by the Contractor or Subcontractor whose work is to be inspected or tested. Any conflict of interest must be disclosed to the Building Official, prior to commencing work. Seismic Design Category: B Basic Wind Speed (3 Second Gust): 115 Wind Exposure Category: B CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Sheet 3 of 10 Project: Adirondack Outlet Mall Qualifications of Inspectors and Testing Technicians The qualifications of all personnel performing Special Inspection and testing activities are subject to the approval of the Building Official. The credentials of all Inspectors and testing technicians shall be provided if requested. Key for Minimum Qualifications of Inspection Agents: When the Registered Design Professional in Responsible Charge deems it appropriate that the individual performing a stipulated test or inspection have a specific certification or license as indicated below, such designation shall appear below the Agency Number on the Schedule. PE/SE Structural Engineer—a licensed SE or PE specializing in the design of building structures PE/GE Geotechnical Engineer—a licensed PE specializing in soil mechanics and foundations. EIT Engineer-In-Training—a graduate engineer who has passed the Fundamentals of Engineering examination American Concrete Institute (ACI) Certification ACI-CFTT Concrete Field Testing Technician—Grade 1. ACI-CCI Concrete Construction Inspector ACI-LTT Laboratory Testing Technician—Grade 1&2. ACI-STT Strength Testing Technician. American Welding Society(AWS)Certification AWS-CWI Certified Welding Inspector. AWS/AISC-SSI Certified Structural Steel Inspector American Society of Non-Destructive Testing (ASNT)Certification ASNT Non-Destructive Testing Technician—Level II or III International Code Council (ICC) Certification ICC-SMSI Structural Masonry Special Inspector ICC-SWSI Structural Steel and Welding Special Inspector ICC-SFSI Spray-Applied Fireproofing Special Inspector ICC-PCSI Prestressed Concrete Special Inspector ICC-RCSI Reinforced Concrete Special Inspector National Institute for Certification in Engineering Technologies (NICET) NICET-CT Concrete Technician—Levels I, II, III & IV NICET-ST Soils Technician- Levels I, II, Ill & IV NICET-GET Geotechnical Engineering Technician - Levels I, II, III & IV Exterior Design Institute (EDI) Certification EDI-EIFS EIFS Third Party Inspector Other SCSI Smoke Control Special Inspector PE/ME Mechanical/Electrical/Plumbing Engineer—a licensed PE specializing in the design of mechanical, electrical and plumbing building systems RA Registered Architect specializing in the design of architectural building systems CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Schedule of Special Inspection Services Sheet 4 of 10 Soils and Foundations Project: Adirondack Outlet Mall Item Agent No. Scope (Qualif.) 1. Site Preparation 2 Section 1704.7.Site preparation.Prior to placement of the (PE or prepared fill,determine that the site has been prepared in EIT) accordance with the Contract Documents. Inspect soils below footings for adequate bearing capacity and consistency with the Contract Documents. 2. Controlled Structural Fill 2 Section 1704.7.During fill placement. During placement and (PE or compaction of the fill material,determine that the material being EIT) used and the maximum lift thickness comply with the Contract Documents. Verify extent and slope of fill placement. 2(PE or Section 1803.5. Compacted fill material. Perform sieve tests and EIT) modified Proctor tests of each source of fill material. Through testing,verify that the compacted fill to be used under footings and under slabs complies with the Contract Documents. 2(PE or Section 1704.7.Evaluation of in place density.Review that the EIT) in place dry density of the compacted fill complies with the Contract Documents. 3. Deep Foundations Not applicable. 4. Underpinning Not applicable. 5. Other 2 Within the building perimeter,observe placement of underslab and (PE or perimeter drainage elements,including crushed stone,perforated EIT) pipes,and geocomposite drains. CASE Form 101 • Statement of Special Inspections • CASE 2004 • New York State 2010 Schedule of Special Inspection Services Sheet 5 of 10 Cast-in-Place Concrete Project: Adirondack Outlet Mall Item Agent No. Scope (Quaff.) 1. Mix Design 1 Table 1704.4.4. Review concrete mix design submittals for all (PE or classes of concrete specified on the structural drawings.Reference EIT) standard ACI 318:Ch.4,5.2-5.4.BC-NYS Reference Sections 1904, 1905.2-1905.4, 1914.2 and 1914.3. Review concrete batch tickets and verify compliance with 2 approved mix design. Verify that water added at the site does not (ACV exceed that allowed by the mix design. 2. Material Certification 1 Section 1704.4.1.Materials. Review material certificates of (PE or compliance or other acceptable documentation for all materials Eli) used in the concrete mix designs for conformance with ACI318 Chapter 3. In the absence of sufficient data or documentation providing evidence of conformance to quality standards of materials in chapter 3 of ACI 318,materials shall be tested in accordance with the appropriate standards and criteria. 3. Reinforcement Installation 1 Table 1704.4.1. Review the following percentages of installed & reinforcement for compliance with approved shop drawings, 2 project specifications and AC1318:Ch. 3.5, 7.1-7.7.BC-NYS (ACI) Reference Sections 1903.5, 1907.1, 1907.7 and 1914.:Footings 50%,Foundation Walls 50%,Elevated Slabs 100%. 4. Post-Tensioning Operations Not applicable 5. Anchor Rods 1&2 Table 1704.4.3. Review 100%of bolts to be installed in concrete (ACID prior to and during placement of concrete where allowable loads have been increased.BC-NYS Reference Section 1912.5. 6. Concrete Placement 2 Table 1704.4.6. Continuous inspection of concrete placement for (ACI) proper application techniques as specified in ACI 318.5.9 and 5.10.BC NYS Reference Sections 1905.9, 1905.10, 1914.6, 1914.7 and 1914.8. Verify that concrete conveyance and depositing avoids segregation or contamination. Verify that concrete is properly consolidated. 7. Sampling and Testing of 2 Table 1704.4.5. Make one strength test for each 50 cubic yards or Concrete (ACV fractions thereoffrom each mix design of concrete placed in any one day. (ASTM C 172,ASTM C 31,ASTM C39).Also, test each specimen for slump(ASTM C143),air content(ASTM C231 or C173),and temperature(ASTM C1064).ACI Reference ACI 318: Ch.5.6 and 5.8.BC-NYS Reference Sections 1905.6 and 1914.10. 8. Curing and Protection 1 Table 1704.4.7. Review periodically for maintenance of specified curing temperature and protection techniques, in accordance with ACI318:5.11-5.13.BC-NYSSections 1905.11, 1905.13 and 1914.9. Further,when hot weather concrete conditions exist, verify that the procedure outlined in ACI 305R for Hot Weather Concreting is followed. These conditions will exist when the rate of evaporation approaches 0.21 lb./ft.2/hr. For Cold Weather Concreting,follow ACI 306.1 standard spec. CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Schedule of Special Inspection Services Sheet 6 of 10 Structural Steel Project: Adirondack Outlet Mall Item Agent No. Scope (Qualif.) 1. Fabricator Certification / 1 Section 1704.2. Verify whether Fabricator holds a current AISC Quality Control Procedures (PE or certification for Standard for Steel Buildings Structures(SW).If ❑ Fabricator Exempt Ell) so,special inspections as required by Section 1704.2 shall not be required.If not,perform the following: 1 Prior to fabrication, verify that the fabricator maintains detailed (PE or fabrication and quality control procedures that provide a basis for EIT) inspection control and workmanship and the fabricator's ability to conform to the approved construction documents and referenced standards.Review the procedures for completeness and adequacy relative to the code requirements for the fabricator's scope of work 1 At the completion of fabrication, the approved fabricator shall (PE or submit a certificate of compliance to the code official stating that EIT) the work was performed in accordance with the approved construction documents. 2. Material Certification 2 Table 1704.3.1;Table 1704.3.3;Table 1704.3.4. Intermittent (AWS) observation of 50%of structural steel, high-strength bolts,nuts, washers and weld filler materials for proper materials identification markings for(conformance with ASTM standards specified in the approved contract documents. The inspector shall be present in the area where the work has been or is being performed,and also at the completion of the work 1 Review structural steel manufacturer's certified mill test reports; (Eli) high-strength bolts,nuts,washers and weld filler materials for manufacturer's certificate of conformance with ASTM standards specified in the approved contract documents. 3. Open Web Steel Joists Not applicable 4. Bolting 2 Section 1704.3.3.;Table 1704.3.2. High-strength,bearing—type (AWS) connections: Intermittent observation of 50%of bolted connections for required size,location and number of bolts and also for contact of plies. The minimum bolt tension,method of tightening and method of inspecting installed bolts shall be as specified in AISC "Specifications for Structural Joints Using ASTMA-325 or A-490 Bolts", and the commentary that follows. Use of a calibrated torque wrench on a previously tightened bolt is not an acceptable method of inspection. High-strength,slip-critical connections: continuous observation of all bolted connections for required size,location and number of bolts. Verify that the specified procedure for installation is properly used for tightening bolts. CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Schedule of Special Inspection Services Sheet 7 of 10 Structural Steel (cont'd.) Project: Adirondack Outlet Mall 5. Welding 2 Prior to fabrication, verify that Welding Procedures Specifications (AWS) (WPS)are followed and are performed by qualified welders,both in the shop and in the field. Section 1704.3.1.;Table 1704.3.5. 2 Complete and partial penetration groove welds:submit all (ASNT) Prequalified Complete and/or Partial Joint Penetration Joint Details. Utlrasonic test 100%of all welds. 2 Multi pass fillet welds: visual inspection of 100%of all shop (AWS) welds if fabricator is not certified as noted in Item 1. Visual inspection of 100%of all welds and all passes being performed every third working day if fabricator is certified as noted in Item 1. Visual inspection of 100%of all field welds and all passes. Magnetic particle test 5%of all field welds for each pass. 2 Single pass fillet welds larger than sibs": see Multi pass fillet (AWS) welds for details except that there is only a single pass to be inspected. Also,Magnetic particle test 10%of all field welds. 2 Single pass fillet welds smaller than 5/16": visual inspection of (AWS) 50%of all shop welds if fabricator is not certified as noted in Item 1; this percentage may be reduced after fabrication starts if approved by the SER. Visual inspection of 50%of all welds being performed every third working day if fabricator is certified as noted in Item 1; this percentage may be reduced after fabrication starts if approved by the SER. Visual inspection of 50%of all field welds. Magnetic particle test 5%of all field welds. 2 All Welds: Submit welder Qualification record(WQR)including (AWS) location,position, torch,size and type of weld along with verification of welder's certification. Before welding starts, confirm that fit-up base metal tolerances are in conformance with AWSD1.1; see above for the required percentage 6. Shear Connectors Not applicable 7. Structural Details 1 Section 1704.3.2;Table 1704.3.6. Visual inspection of the erected steel frame to verb compliance with AISC "Code of Standard Practice"Section 7.12, 7.13 and with details shown on the approved shop drawings,such as bracing,stiffening, member locations and proper application ofjoint details at each connection. 8. Metal Deck 2 Verfy that welders are certified in accordance with AWSD1.3-98. (AWS) Inspect 50%of weldments and side-lap fastening for required size, location and number for conformance with the approved contract documents. Verify thickness of metal floor deck for conformance with the approved contract documents for each type of deck used prior to pouring concrete. CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Schedule of Special Inspection Services Sheet 8 of 10 Cold-Formed Steel Framing Project: Adirondack Outlet Mall Item Agent No. Scope (Quaff.) 1. Member Sizes 1 Visual inspection of 100%of the erected cold formed steel framing to verify compliance with details shown on the contract documents and approved shop drawings. 2. Material Thickness 2 Verify that 25%of the material thicknesses are in conformance with the contract documents and approved shop drawings. 3. Material Properties and 1 Review material certification submittals to verify conformance Material Certification with contract documents 1 Inspect cold formed steel members,fasteners, and weld filler material for proper materials identification markings as required by the approved drawings. 4. Mechanical Connections 2 Inspect 25%of threaded fasteners, bolting, anchoring,powder actuated fasteners, and other fastening of components to verify conformance with the contract documents and approved shop drawings. 5. Welding 2 Verify that welders are certified in accordance with AWS D1.3-98. (AWS) Inspect 50%of all welds to verify conformance with the contract documents and approved shop drawings. 6. Framing Details 1 Visual inspection of the erected cold formed steel frame to verify compliance with details shown on the contract documents and approved shop drawings,such as bracing stiffening, member locations and proper application of joint details at each connection 7. Other 1 Review design calculations by manufacturer's engineer and shop drawings to verify adequacy of design and details for conformance with the contract documents. The manufacturer's engineer will seal design calculations. CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Schedule of Special Inspection Services Sheet 9 of 10 Wood Construction Project: Adirondack Outlet Mall Item Agent No. Scope (Qual if.) 1. Fabricator Certification/ 1 Section 1704.2. Quality Control Procedures Prior to fabrication,verify that the fabricator maintains detailed fabrication and quality control procedures that provide a basis for inspection control and workmanship and the fabricator's ability to conform to the approved construction documents and referenced standards.Review the procedures for completeness and adequacy relative to the code requirements for the fabricator's scope of work. At the completion offabrication, the approved fabricator shall submit a certificate of compliance stating that the work was performed in accordance with the approved contract documents 2. Material Grading 1 Review 10%of grade stamps of dimensioned lumber for conformance with the contract documents. 3. Connections 1 Review 75%of hanger connections, 75%of tie-downs, 100%of shear wall hold-downs,and 50%of nailing,bolting,anchoring and other fastening of components for conformance with the contract documents. 4. Framing and Details 1 Review 75%of completed framing installation prior to concealment by surface finishes for compliance with details shown on the construction drawings including all connections to the supporting structure,field cut notches and drilled holes performed by the mechanical trades. Review all bearing points and all permanent bracing required by fabricator and the architect or engineer of record. 5. Diaphragms and Shearwalls 1 Inspect size,configuration, blocking and fastening(including holdowns,see Item 3)of shearwalls and diaphragms. Verify panel grade and thickness. CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 Schedule of Special Inspection Services Sheet 10 of 10 Prefabricated Wood Trusses Project: Adirondack Outlet Mall Item Agent No. Scope (Quaff.) 1. Fabricator Certification / 1 Sections 1704.2.;1704.6. Verify whether the wood truss Quality Control Procedures Fabricator participates in the "Truss Plate Institute's Quality Assurance Inspection Program If so,special inspections as required by Section 1704.2 shall not be required.If not,perform the following: 1 Prior to fabrication, verify that the fabricator maintains detailed fabrication and quality control procedures that provide a basis for inspection control and workmanship and the fabricator's ability to conform to the approved construction documents and referenced standards.Review the procedures for completeness and adequacy relative to the code requirements for the fabricator's scope of work. 1 At the completion of fabrication,the approved fabricator shall submit a certificate of compliance stating that the work was performed in accordance with the approved contract documents. 2 Material Certification 1 Review 25%of grade stamps of dimensioned lumber for conformance with the contract documents. 3. Connections 1 Review 25%of truss connection plates for gauge thickness,size and location;review 25%of any nailing,bolting,anchoring and other fastening of components;review 25%of mechanical tie- down connections to prevent uplift;and review all truss component fit up and interconnections,for conformance the contract documents and Truss Plate Institute requirements in accordance with ANSI/TPI 1 Standard and the QAP-90 Manual. 4. Fabrication 1 Review 50%of prefabricated trusses for general conformance with the contract documents and Truss Plate Institute requirements in accordance with ANSI/WI 1 Standard and the QAP-90 Manual. 5. Framing and Details 1 Review completed truss and supporting framing installation prior to concealment by surface finishes for compliance with details shown on the construction drawings and approved truss shop drawings including all connections to the supporting structure. Review 25%of all bearing points and all permanent bracing if required by fabricator and the architect or engineer of record. 6. Other CASE Form 101 • Statement of Special Inspections • ©CASE 2004 • New York State 2010 FIRE MARSHAL’S OFFICE Town of Queensbury 742 Bay Road,Queensbury,NY 12804 “Home of Natural Beauty...A Good Place to Live” PLAN REVIEW Dave Kenny 1454 Route 9 CC-0080-2020 2/25/2020 The following list is based on a recent review of drawings: Exit /Emergency lighting fixtures appear adequate. Lock /latches shall comply with Chapter 10 of 2015 IBC,no thumbturns or keys Identify fire extinguisher locations Knox Box is required.Suggest (1)Model 3200 to be used by both tenants Truss ID signage shown Provide details on CFM ratings of HVAC units Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal's Office +Phone:518-761-8206 +Fax:518-745-4437 firemarshal@queensbury.net + www.queensbury.net ENGINEERING rucstructuralsolutions MAR 03 2020 Structural Calculations for Starbucks Adirondack Outlet Mall Queensbury,NY Prepared By: Scott Burlingame,P.E. February 17,2020 ‘Seo Buringome,PE,|900.146,Cliton Pak,NY 12065 |T:518.724.0733 |scok@bengineengplc com ENGINEERING ruc eer”——————Sbsis_structural solutions Gate.By —~Seoi Burlingame,P pate 2717720 BUILDING DESIGN LOADS Roof Dead Loa:Built Up Roofing and Insul.=6 psf 5/8"Plywood Sheathing =2 pst Wood Roof Trusses =4 psf Sprinkler System 3 pst ‘Mechanical Ducis =2 pst 2-Layers 5/8"Gyp.6 psf Ceiling &Lights 2 pst 25 pst Roof Live Load:Flat Roof Snow Load =38.5 __psl Total Roof Design Load =65.5 pst Seismic Roof Dead Loud:Built Up Rooting and Insul.=6 pst 5/8*Plywood Sheathing =2 psf Wood Roof Trusses =4 pst Sprinkler System 3 pf ‘Mechanical Duct 2 psf 2-Layers 5/8"Gyp.5 opsf Ceiling &Lights =2 pst 20%Flat Roof Snow Load =8 pal 33 psf fypiceil Floor Dead Loud:‘3 (18ga.)w/3 1/2"NW Conc.=65 pst Ceiling &Lights =3 psf Misc.Mech.Ducts =3 psf Misc,Loads =4 pst 75 psf +Steel Selfweight ‘Typical Floor LiveLoad: Public Space =100.pst Scot argos,PE,|900145,Clon Pak,NY 12045 |1:518-724.0739 |ac@stengineningiccom ‘rare020 xxtown Cat Wilderness OTC Hazarisb , ®| Search Informatio:Oe borage rune ited w KitingtonWestGanadaaAddress:1454 L Lake C2}Rattan ~—Blackriver Wildemess 531 ft Coordinates:43.366,Wild Forest Elevation:eat ft Sueensburye 2 x ome Fertis Lake Glen’FallsTunestamp:2020-¢,Rape Wild Forest:d Manepestershade}! Gloverssile Sprinas Green °Mountain:Google {Ma dete 62020 Google Hazard Type:Snow Dai ASCE TAG Oo Haglion f Sotenectady Brau {Coosestoen oS Ground Snow Load oO Albany ‘ The reported ground snow |Noryich |the query location of 531 fet ©Gra f Pittsfiokd } ‘maximum elevation of 700 f rata an o wb)pce,nenttnmea4TheresultsinciatedhereEtonaeSpring code adoption process.Use A 1 proceeding with design. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. ‘While the information presented on this website is believed to be correct,ATC and its sponsors and contributors assume no responsibilty ‘or liability for ts accuracy.The material presented in the report should not be used oF relied upon for any specific application without ‘competent examination and verification ofits acouracy,suitability and applicability by engineers or other licensed professionals.ATC does ‘ot intend that the use of this information replace the sound judgment of such competent professionals,having experience and knowledge In the fleld of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website.Users of the information from this website assume all liablity arising from such use.Use ofthe output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. |ttps:hazards.atcounclorgisnow7lat=43,3665423000000 18ing=-73.6976741 address=1454 U.S.9%2C Lake Goorge%2C NY 12845%2C USA tit ENGINEERING rucstructuralsolutions JOB NAME SHEET # Bldg.Area:Ente Roof Ground Snow Load:‘5 psf (Av elevations up io 1000 fee!) Project Site Elevation:200 fi Adj.Ground Snow (pg):50 pst ‘ulin Ocupancy———Terran Category ————OF Aorictrat OA tage cty Centers |@ 1-Generat 8.General Urban /Suburban On -Assembly Oc.open Terrain ©W-Ciel Services >OD.Open shoreine Root Exposure “Thermal Fador———— }O Fay Exposed }O structures Not Note low }@ Poorly Heated/Well Insulated 2 ©Unheated structures Importance Factor ():10 Thermal Factor (Cj: Exposure Factor (Cj:10 Snow Density (g):20.5 pst Flat Roof Snow Load (p):38.8 psf Height of Uniform Snowe (hy) Note:This spreadsheet calculates the flal-roof snow load based on the “Building Code of New York State"(2015)&ASCE 7-10 criteria.To use, enter the ground snow load and select the appropriate building criteria, rf} Starbucks OF CALC.BY—Scoit Burlingame,P.E.DATE 2/7/20 19 tt Scot Brings 6,|900.146,Citon Pork,MY 12065 |T:S18.7240735 |scotGebengioongll cor ENGINEERING ruc soo Stouts«WOKobYestructuralsolutionsOr‘Scott Burlingome,PE.(CALCULATED 6¥___Ate.900 RI.146,Clifion Pork,NY 12065 ccHeckeo By are7:518.724.0733 scotl@sbengineeringplle.com sone. [Root Retry S We So(2s racy +1450 vb dey one 129 bh we mH Kk Wvexyo.Ta SSt AYB60 Te lve 7244 ge Me ©Ns Frcop.benr we y_(100 +75)>1750 gif Wno«3oa yallwe22643Tes Rs iow %PB 409 Ty ot wen THAT EU ood W0-HS Clete.HE,GU 12020 *“Wilderness,Piddiebucy ~~ser xtlown ¢Wilderness phe QTC Hazards b \: | Search Informatior Oat ora (53 Kitin Address:1454 L RatanBlackRiverCoordinates:43.366.Wild Forest Elovati 531 ft ..Ferris LakeTimestamp:ro20¢Rome Faia Lake samen Hazard Type:Wind Ones Utica GreengeMountain ‘Map data ©2020 GoogleDBan>\BaitASCE7-16 ony { -Schenectady .i 33 whee 4 1 i Coope:stev ®vg ¥ & é MRI 10-Year {o Albany MRI 25-Yoar Oneonta i Pittafotd )} eyux An MRI 50-Year tee {Stockbridges D Wortham MRI 100-Year I Pap ii(5 Risk Category |waren Sennen Risk Category I 4108 mph Risk Category It 115 mph Risk Category It 146 mph Risk Category iV 120 moh Risk Category IV 424 mph The results indicated here DO NOT reflect any slate or local amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer.Per ASCE 7,islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area —in some cases,this website will extrapolate past the last wind speed contour and therefore,provide a wind speed that is slightly higher.NOTE:For queries near wind-borne debris region boundaries,the resulting determination is sensitive to rounding which may affect whether or not itis considered to be within a wind-borne debris region, Mountainous terrain,gorges,acean promontories,and special wind regions shall be examined for unusual wind conditions. While the information presented on this website is believed to be correct,ATC and its sponsors and contributors assume no responsibilty cr liability for its accuracy.The material presented in the report should not be used or relied upon for any specific application without ‘competent examination and verification of its accuracy,suitability and applicability by engineers or other licensed professionals,ATC does not intend that the use of this information replace the sound judgment of such competent professionals,having experience and knowledge in the field of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the ‘eport provided by this website.Users of the information from this website assume all liability arising from such use.Use of the output of this wehsite’cons nn imnly annraval by tha overnina bulldina end hades resnonsible for buillina ende annroval and internretatian for the, btipsihazards.atcouncl orgwind lat=43.3665423000000 1 &ing=-73.697674 1 Raddross=1454 U.S.9%42C Lake George%s2C NY 12845%2C USA 112. ‘ATC Hazards by Location building site described by latitude/longitude location in the report. httnsUmazards.stcounciorgitivind 7lat=43,96654230000001 &ing=-73.697674 1Baddress=1454 U.S.9%2C Lake George%2C NY 12845%2C USA 22 von Snesucet=AOE Ouner vouENGINEERINGrucstructuralsolutions Scott Burlingame,PE.enccunare ey Sf,ome 2)ut)20%e 900 Ri.146,Clifton Pork,NY 12065 cecxeny.are T:518-724-0733 scolt@sbengineeringplle.com seatWem[stteaw wens 2 pmens—(asce II |CaPT Th Croverses sine %Si mevicien) tos =a is,SS *NES gs git [Beat Exh B® :De hoisosamyna!.oe DO]Bae Lave SHERE Long +WYBIE Ve 2 ek .ont ae esetwySw) See,QeEUst elt WSS TES He AG Ne Oup?CAM ove (Te)+10 (WEA Vs Prove Her easing wl Ed oY "rc.EPUE HEU Hewes“)SL yA (ving)Bott oa]Vf tose moe. Suy-2=SestoI Sah FUL Siena ‘Cor OW (Losseevorive)\s Se as aitalr)© &Teste Yeowoe Wp ee sit |FA cGoe.ERE val Symesond HOU Hepes woo STACHUCCS ~— MD.OUITLET verveENGINEERINGruc ,seersstructuralsolutions Scott Burlingame,PE cacumeosy wre2hare900Ri.146,Clifton Park,NY 12065 Genennr,owe. 7:518-724-0733, scoll@sbengineeringplle.com seme Kats N2 4966 Mo De atte/yo +125 gh fees 7 He UE SAG MmBicIA PF Herdswe)pL Suz BWAY mAh Sew Ma susS By issitecdens Additional Information .o |Middlebury ww7272020townCantsgeWildemessf— |:* )OTC Hazards by Lc .| } \ Lowgetle Ita Le \\ Search Information Old Foros West Canada Address:1454 US.¢wantBlackRiverWilderness Coordinates:43,9005425 |Wild Forest Elevation:531 ft | 2 Ae Fertis LakeLeeman2020-05-01 Payne Wild Forest enatelteteHeSeinepalneegviieGreen, .en ¢MountainReferenceASCET-10 |Google {ap data €2020 GoogleDocumer-\1DB i f Risk Category:Hanlon Schenectady reJa7 retovar 7 1 ¥Site Class D Ly «sown “AlbanyMCERHorizontalRe: } )fNorah-f ‘sa(g)|ovens sata)Ff Piltfiold t 0.28 i __Leyox frit030ae0.20 HortaYouwr020amon045Springt |‘a)4 |0.10 |0.05 |0.00 0.00 | 09 4.0 20 30 40 50 60 70 Petiod(s)00 10 20 30 40 50 60 7.0 Perlod(s) |Basic Parameters Name Value Description 8s 0239 MCE ground motion (period=0.2s)os 082 MCE ground mation (period=1.0s) Sus 0.382 Site-mosified speciral acceleration value Sut o.197 Site-modiied spectral acceleration value be 0.255 Numeric seismic design value at 0.28 SA |8 31 Numeric seismie design value at 1.08 SA | |Name Value Description |soc 8 Seismic design category Fi 16 Ste amplification factor at 0.25 Fy 24 Site amplification factor at 1.05 |itps:azards.atcouncl.org/tiseismicat=43.36654230000001 &ing=-73,6976741 Baddress=1454 U.S.9%2C Lake George%2C NY 12845%2C USA 1/2 sr2ie20 .ATC Hazerds by Location CRs 0.908 Cozlficient of risk (0.25) CR,0.894 Coefcient of risk (1.08) PGA 0.122 MCEg peak ground acceleration Fron 1.857 Site amplification factor at PGA PGAy 0.189 Site modified peak ground acceleration mT 6 Long-petiod transition period (s) SeRT 0.238 Probabilistic risk-targeted ground motion (0.28) SoUH 0.263 Factored uniform-hazard spectral acceleration (2%probability of ‘exceedance in 0 years) SsD 15 Factored deterministic acceleration value (0.28) SIRT 0.082 Probabilistic risk-targeted ground motion (1.08) SiUH 0.092 Factored uniform-hazard spectral acceleration (2%probability of ‘exceedance in 50 years) S10 06 Factored deterministic acceleration value (1.05) PGAd 0s Factored deterministic acceleration value (PGA) The results indicated here 00 NOT reflect any state or local amendments to the values or any delineation lines made during the building cade adoption process.Users should cantim any output obtained from this tool with the focal Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S.Geological Survey SelemicDesignWabServices. While the information presented on this website Is belleved to be corract,ATC and its sponsors and contributors assume no responsibilty or liablity forts accuracy.The material presented in the report should not be used or relled upon for any specific application without competent ‘examination and verification ofits accuracy,sultablity and applicability by engineers or olher licensed professionals.ATC does not intend that theseofthisinformationreplacethesoundjudgmentofsuchcompetentprofessionals,having experience and knowledge in the feld of practice,nor ‘0 substitute for the standard of care required of such professionals in interproting and applying the results of the report provided by this website, Users of the information from this website assure al lability arising from such use.Use of the oulput ofthis website does not imply approval bythegoverningbuildingcodebodiesresponsibleforbuildingcodeapprovalandinterpretationforthebuldingsitedescribedbylatlude/longitude location in the report. bilps:hazards.elcouncilorgftiselsmic?iat=43,96654230000001 ing=-73,697674 1Baddress=1454 U.S.9%2C Lake George%2C NY 12845%2C USA 22 JOB NAME StarbucksENGINEERINGsucSueere3)—— "se ———_ structural solutions CALC.BY ~ScoiBulingame, PE DATE DATO Note 1.This spreadsheet colculaies the seismic design coeflicients and building design category per the "Building Code of New York State -2010" Use spectral accelerations based on «2%PE in 50 years. Not valid for Site Class F or E w/$,>1.0,5)>0.4. To determine Ss &Sy,input project address in USGS, online ground hazard application Site Address:1454 State Route 9,Queensbury,NY Data:lapped spectral acceleration for short periods Mapped spectral acceleration for a 1-second period ste Class ‘Occupancy Category O ste cass A ©1a0-Generayagruturat O ste cass 8 (Ot Assembly O Site cass ¢O 1V-citical Services ©@ Site class D O Site ciass & O Ste cass F Fa.1.60 Fy2 2.40 Susx 0.382 Sure 0.197 Sog=0.255 Sore 0.131 ‘SD Cat B ‘SD Cat B Seismic Design Category B Seat Bulngame,PE.|9008.146,Cito Pak,NY 12065 |Ts 518.726.0733 |scok@sbeagineenglcom ENGINEERING ruc fiery)|eeNbbidedtatedsheerOFBystrecturalsolutionsuegyScottBurlingame,P.E,pate __2/17/20 Dota:Buliding Occupancy Seismic Direction OF Apeanet ©%dren @ 11-General O *Y"Direction OU Assembiy O _W-Gitical Services {ERM Require Input by User Sps=Mapped spectral acceleration for short periods So=Mapped spectral acceleration for @ 1-second period Re Response Modification Coefficient (Ordinary plain masonry shearwalls)l=Importance Factor hy=Total Building Height Above Base (f)Ge Building Period Coefficient Calculate Seismic Base Shear: 0.152 Approximate Fundamental Period (seconds) 0.011 Minimum Seismic Response Coefficient 0.039 Seismic Response Coefficient 0.132 Maximum Seismic Response Coefficient =0.039 Governing Seismic Response Coefficient Total Seismic Weigl Seismic Base Shear :v, 170.00 (Force in Kips) 6.67 (Force in Kips) Calculate Vertical Distribution of Seismic Forces: Distribution Coefficient)=1.00 level]Wa hy Roof __|170.00|15.00 0.00 |0.00 667 0.00 |__0.00 0.00 0.00 0.00 0.00 0.00[1.000 6.67_| Scott Buringame,PE.|900 Rt.14,Cifton Park,NY 12085 |7:518.724.0733 |scotleebenginesringp.com