2007-539 (zt TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number. P20070539 Date Issued: Tuesday, October 16, 2007
This is to certify that work requested to be done as shown by Permit Number P20070539
has been completed.
Tax Map Number. 523400-290-017-0001-003-000-0000
Location: 64 MASTERS COMMON SOUTH
Owner. L. EDWARD BOYLE
Applicant: L. EDWARD BOYLE
This structure maybe occupied as a:
Deck
Fireplace By Order of Town Board
p TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building& de Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development Building&Codes (518) 7,61-8256.
BUILDING PERMIT
Permit Number: P20070539 Application Number. A20070539
Tax Map No: 523400-290-017-0001-003-000-0000
Permission is hereby granted to: L. EDWARD BOYLE
For property located at: 64 MASTERS COMMON SOUTH
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other infonnation hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: L. EDWARD BOYLE Deck $20,000.00
64 MASTERS COMMON SOUTH Fireplace
QUEENSBURY,NY 12804 Total value $20,000.00
Contractor or Builders Name/Address Electrical Inspection Agency
Plans &Specifications
2007-539
421 SQ FT DECK WITH OUTDOOR FIREPLACE
$42.10 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,August 21, 2008
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To o eensb s y,August 21, 2007
SIGNED BY for the Town of Queensbury.
de Enforcement
Director of Building&Co
:i•
--------- -------------------------------------------- ------- --- - - _.--_-
q OFFICE USE ONLY ;
TAX MAP NO. ��� PERMIT NO. lo�z — ,s 3 / ,
FEE PAID BLDG. &CODES APPROVAL
------------------------------ ---,_,__------------,-_
ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION
Use this application for any structure other than the Principal Structure(house)to include, but not limited to:
garage, shed, greenhouse,dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-
Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID
PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT.. -}
OWNER:ed �� INSTALLER/BUILDER: 1'C �D►�)1 � .1:.0
ADDRESS: �1p,�^�O.S�QQInn ar��Vfi� ADDRESS: ?O p�X (Oi2A QF N% ����1
PHONE NOS. 1 &- /��Q6 PHONE NOS. , 1 a�- -Ia l�
LOCATION OF PROPERTY�d 1 MO S tit►.C t-, SovZ (SUBDIVISION NAME: c
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: (' L 1 1 'ya&C s N
ESTIMATED COST OF CONSTRUCTION: $ ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? WO
IF YES,PLEASE LIST: f
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:1 \OVA \ C1 CQhe- PHONE: JbV oc-ab
18T FLOOR 2ND FLOOR TOTAL PROPOSED
PROPOSED CONSTRUCTION SO.FT. SQ.FT. SQ.FT. HEIGHT
FT.&IN.
OPEN PORCH
DECK
3 SEASON,COVERED OR ENCLOSED PORCH`
BOATHOUSE
BOATHOUSE WITH SUNDECK
DOCK
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS:
OTHER ACCESSORY STRUCTURE:
`CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR(FLOOR AREA RATIO)REQUIREMENTS IF THE STRUCTURE IS LOCATED IN
THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge,the statements contained in the application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Codes,the Zoning Ordinance,and all other laws pertaining to the proposed work shall be
complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that
Itwe shall submit prior to a Certificate of Occupancy or Certificate of Compliance
being issued,as requested by the Zoning Administrator or Director of Building
and Codes,an As-Built Survey by a licensed surveyor,drawn to scale, QUESTIONS? CALL 761-8256 OR EMAIL
showing actual location of all new construction. codes(cD_queensbury.net
I have read and agree to the above. VISIT OUR WEBSITE FOR MORE INFORMATION
www.gueensbury.net
Signed Dated:
Name/Title(Printed) `� `�+ C� ��►,e v
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
Q�Too:
munity Development Office of Queensbury - 742 Bay Road• Queensbury, New York •12804 i ;
Dee,.:StaMD
•David Hatin,Director of Building&Codes ;
Craig Brown,Zoning Administrator•Michael J.Palmer,Fire Marshal
----------------------4
APPLICATION FOR FUEL BURNING APPLIANCE & CHIII MEYS
Application is hereby made to the Building &Codes Office for the issuance of a Building 8,Use Permit
pursuant to the New York State Fire Prevention &Building Code. The applicant or owner agrees to comply
with all applicable laws,ordinances,regulations,and all conditions that are part of these requirements and
also will allow all inspectors to enter premises to perform required inspections.
IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED.
OWNER: E- bQ-fL(—_ INSTALLERBUILDER:.ADDRESS:. //D(O LI 5 r ksl_oY co ) ADDRESS:
PHONE NOS. -�o�D�o PHONE NOS.
LOCATION OF PROPERTY: b 4 (SUBDIVISION NAME: p
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION:
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE:
STOVE
FIREPLACE INSERT
FIREPLACE,FACTORY BUILT* X
FIREPLACE,MASONRY
FURNACE(GARAGE ONLY)
*IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME:� t3 c L%,AW C' GA X---, MODEL NO.V"CN_,S S�SuY�
LISTED BY: �1 L^ NUMBER: 1 C�r,
QUESTIONS?
CALL 761-8205 or 761-8206
OR EMAIL:
firemarshal9b-gueensburv.net
MASONRY** CHECK ONE ✓ VISIT OUR WEBSITE
FOR MORE INFORMATION
www.aueensburv.net
FLUE CHECK ONE ✓
u c
CHIMNEY MATERIAL CHECK ONE ✓ `` l
**IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME.ICN)t� MODEL
ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR
MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED
INSPECTIONS.
�-5
,
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depart: jj am/pm
Date Inspection request re eiv : /U /C>la-7 Inspector's Initials:
NAME: ✓1 '� C. PERMIT#: pZoG 7 — S 3
LOCATION: IVAW Cen-% DATE:
TYPE OF STRUCTURE:
Comm
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s . ft.-150 s . ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s . ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum''/2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
i
Town of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 12804
761-8205/761-8206
fax 745-4437
Factory Built Wood Burning Fireplace/Stove Inspection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit# Schedule Inspection gjd,1v 7 Time 3 y am J6)anytime Inspector Y ' Tf
Name Address ("l thA'57-4 S Coo"✓v---- S Rough In Final �
Appliance Manufacturer V'Y)4T'3f5+14 Model# O P Spa
Masonry Chimney Factory Built Chimney, Flue Size Double Wall Triple Wall Insulated_
Yes No N/A Comments
Floor Protection
1fv4- ti"r, y-�
Clearances to Combustibles(all sides)
Safety Strip Installation (fireplaces only)
Firestop(s) vertical Chase
Wall Penetration
Chimney Clearances to Combustibles
Chimney Termination
3 feet above roof penetration;2 feet above Al
any combustible construction within 10 feet
Combustion Air
Hearth Extension
Mantel(height above f/p opening)
Fireplace Doors /Screen (required)
White—Building Dept. Mello — mer Pink—FU*Marshal
.T��
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm De am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: - PERMIT#:
LOCATION: ` SPECT ON: �-
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
'-�grs � —Y
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Foims\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
,3rr f.
Two of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 12804
7614PM/761482%
fan 745-4437
FactQry BuilFir+eplace/Stove Tnsue+ction Ktepart
Notice:New York State requires that all UL Listed,factory built appliances be installed according to ructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from a manufacturer's
instructions or specifications is allowed.
Permit#_J Schedule Inspection_7,;2�me m anytime or
Name_&y
L— .- _ Address in Rough
Appliance Manufacturer _]!+r!5.1 S'f- i L. Model# >
Direct Vent Factory Built Chimney Flue Size Double W Triple Wall Insulated
Yes No N/A Comments
Floor Protection
Clearances to Combustibles (all sides)
Firestop(s) Vertical Chase f
Wail Penetration �\
Vent Clearances to Combustibles
Vent/Chimney Termination
Chimney height must be 3 feet above r f
penetration;2 feet above any combu le
conatrnetion within 10 feet
Gas Shut-Off Valve
Combustion Air
Hearth Extension (if any)
Mantel
Height above Vp opening
Witness Operation
Tank Placement(if LP)
'VYhW—Fe3I"sDept __ __,. __ _ Yellow r Pink—FtrolY2aralwl
I
NOTE
w�
� z Z , o
GENERAL NOTES. W OREC dd U � 0
1• THE NEW DECKING MATERIAL IS TO BE 5/4 x 6 (1% 5 1/2") PRE-GROOVED IPE DECKING FOR TOWN OF QUEENSBURY ° z ob W
USE WITH THE 'IPE CLIP' HIDDEN DECK FASTENER SYSTEM, USE STAINLESS STEEL SCREWS, AS x z �
BUILDING & CO ES T. � X x TObvry yr MANUFACTURED AND SOLD BY WWW.IPEDEPOT.COM U ¢ u
Reviewe
BUILDING AND C,:.;.:: Q v, w
a w
2. IT IS RECOMMENDED THAT ALL OF THE DECKING BE STAINED WITH 'AUSTRALIAN TIMBER OIL', Date: y O o °
MAHOGANY FLAME, AS MANUFACTURED BY CABOT STAIN COMPANY PRIOR TO INSTALLATION. 4
Ow oH00
3. ALL IPE DECK BOARDS THAT ARE END CUT DURING INSTALLATION SHALL HAVE ANGHORSEAL, A
WAX LIKE COATING, APPLIED TO THE FRESH END CUT, PRIOR TO FINISH z 00
0
INSTALLATION/ATTACHMENT TO THE JOISTS.
4. THE CONTRACTOR IS TO CONSTRUCT THE ROUGH OPENING DIMENSIONS FOR THE 5 BURNER NOTE:
VERMONT CASTINGS GRILLE, MODEL # VCS5007BI, PER THE MANUFACTURER'S REQUIREMENTS. THE CONTRACTOR SHALL DISCUSS WITH THE PROJECT F11.
COPY
AN INSULATED JACKET, MODEL VCS50001J, WILL BE REQUIRED DUE TO THE ENCLOSURE BEING ARCHITECT THE INSTALLATION OF AN ADDITIONAL BEAM
COMBUSTIBLE. COORDINATE WITH VERMONT CASTINGS SPECIFICATIONS & DIMENSIONS. & POSTS AT THE OUTSIDE EDGE OF THE DECK PRIOR
TO COMMENCEMENT OF CONSTRUCTION.
5. OPTIONAL ACCESSORIES FOR THE VERMONT CASTINGS FIREPLACE, MODEL # ODSHR42, INCLUDING
OUTSIDE AIR TERMINATION KITS AND GLASS DOORS SHALL BE CONFIRMED WITH THE OWNER 3" 6,-4„ 9'-4 16'-7 "t
PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. ILL
6. THE STUCCO OR EXTERIOR FINISH SYSTEM SHALL BE INSTALLED BY COMPETENT, EXPERIENCED
INSTALLERS PER THE PRODUCTS MANUFACTURER'S RECOMMENDED INSTALLATION INSTRUCTIONS. 1 1
5'-4" 4 -3 j„ x TOWIN OF QUEENSSURY SUILDIING DEPARTMENT
0
l ase go wr limited examination,
(rpoig"Wth OUt CWrawts shall
iig the
N 0• ere in id
2x10 RIM BIRD. 44 POSTS PORTION OF JOISTS �� 1 N SISTER FRAME 2x8 1 �� 8" THICK CONC. Irl
TYP. 22'_0" & RIM TO BE REMOVED — — — JOISTS TO EXIST'G. �„ Ft SLAB, REFER TO SECTION 44D
TYP., COORD. w/ NEW WORK I
OUTLINE OF 8" DIA.
SONOTUBES BELOW, TYP.
Corr — — e - - - -- _- -- - -- f=-=7n
,.-
i
II II it II DECK SUPPORT POST
II II I) II TO BE REMOVED ` III III
II II II II A2 III III A2
� II II it II
II II II II 2x10 BIRD. EA. VERIFY SLAB WIDTH V-11" I TA MI S N -PROPOSED LOCATION
r II II II SIDE OF 4x4 POSTS w/ STUCCO ENCLOSURE, STOD III B CK G.
it OF NEW SUPPORT
TOE KICK CONSTRUCTION 2�_4 BEAM, REFER TO NOTE
LO I®I II II II I� l> �100 ABOVE
11 II 2x8 Jol S II II II II II it II II STAIRS TO BE � ,> III LK N
II ® 16" C. I II II II II II II REMOVED 40—8 II —INSTALL JOIST HANGERS
II II II II II II II II EA. END OF NEW JOISTS
��EXIS ' II
PROPOSED LOCATION 2x8 J0it
S
EXIST'G. EXHAUST FLUES OF NEW SUPPORT ® 16" O.C.
II EXIST'G. EXHAUST FLUES
& VENTS TO REMAIN BEAM, REFER TO NOTE II & VENTS TO REMAIN
ABOVE
LLL== F1_/7,7 - 1 11 111 THIS SHALL BE CONSIDERED AN
ORIGINAL STAMPED PRINT IF THE
SIGNATURE IS IN BLUE INK OVER A
BLACK INK SEAL
UNAUTHORIZED ALTERATION OR
EXISTING RESIDENCE EXISTING RESIDENCE ADDITION To THIS DOCUMENT IS A
VIOLATION OF SECTION 7209
SUBDIVISION 2 OF THE NEW YORK
STATE EDUCATION LAW ® 2007
11
EXISTING FRAMING PLAN I _ FRAMING PLAN N me 1
p1 SCALE:1/4" = 1'-0"
CROSS REFERENCE: 3/A1 Al CROSS 1f�EFEREINCE "/A1,4/A1 ui
PER GRILLE MANUF. COORDINATE EXACT # OF
PROVIDE & INSTALL VENTS 6'-4" READS & RISERS w/FIN. GRADE Im
AS REQ'D. IF LP TANKS 1 0
ARE TO BE STORED IN - - - - -
THE ENCLOSURE - - - - - - 0
HARD SURFACE - - - - - - OUTLINE OF FLUE 210
TOP w/ BACKSPLASH - -� - - - - - - j� ABOVE, 30"x30"sq. A2'
APPROX. GRADE APPROX. GRADE - - - - - - Ln FACE OF STUD 6•
_ » - VERMONT CASTINGS / - - - - - - WALL BELOW
ELEV. 3-9 t ELEV. 4-9 f 5 BURNER, BUILT
22'-O" IN GRILLE, w/ DOORS - - - - - - - - _j VERMONT CASTINGS
zl= / OUTDOOR WOOD BURNING
- - - - - - - - - - - FACE OF STUD // N ��9� FIREPLACE - ODSHR42
__ _ _ _ _ _ _ _ — — — — — — — — — — — — — 1 V)
- - -
- - - - - - - - - - - - - - - - - � REMOVE EXIST'G. WALL BELOW - - - - - - - - - - -- \ /
- - _ _ _ _ _ _ _ _ _ _ _ DECK'G. IN ITS ENTIRETY
I -3 BURNER SERIES OUTLINE OF
= I REMOVE EXIST'G. DOORS, EA. SIDE EXIST'G DECK,
_ I I HANDRAIL, POSTS, ETC. TYP. 0
I I _ _ _ _ _ _ _ _ I IN ITS ENTIRETY
11 - - - - - - - -- - - I -
_ _ _ _ _ _ _ _-_-_-_ REMOVE STAIRS, RISERS, A2 - -- ( �, A2
tx
- - - - - - - - - - - I I TREADS, STRINGERS, ETC. L - - J ( -- -_ -- __
I IN THEIR ENTIRETY — - Q
DECK LEVEL 1 I - -- 5/4 x 6" PRE-GROOVED
I- - - - - PROVIDE CONT. TOE I — ----- I IPE DECKING w/ IPE CLIP
;n ELEV. = 0'-0" KICK ALONG DECK SIDE I HIDDEN FASTENER SYSTEM
I I -ll I7 �� _0" 22'-0" 2'-0' APPROX. 415 SQ. FT.
DN II II II II II II II W Z
- - --_ ----- -- 7R II II I II II ii it
E E E DECK LEVEL WHITE VINYL HANDRAIL
EEE & BALUSTERS
s a' Q
W
- - - - - - - - - - - �L 1LJl —II—ILL ELEV. = 0'-0" --- m
- - - - - - - -- - - - I Z
— — — — — — — — — — — EXIST'G. EXHAUST FLUES EXIST'G. EXHAUST FLUES
& VENTS TO REMAIN & VENTS TO REMAIN > gm W
SLIDING DOOR
SLIDING DOOR
uj
m g ®
EXISTING RESIDENCE NOTE:
COORDINATE ACCENT LIGHTING„ FIXTURES, CONTROLS, EXISTING RESIDENCE PROJECT NO:
LOCATIONS, ETC. w/ OWNER & CONTRACTOR PRIOR DATE : 7/31/07
TO COMMENCEMENT OF CONSTRUCTION.
SCALE : AS NOTED
DESIGNED: JAPAONE
DRAFTED: JAPAONE
2 EXISTING FLOOR PLAN - RE OVALSIN 4 FLOOR PLAN ( N SHEET: 1 of 2
A2 SCALE: 1/4" = V-0" Al ) SCALE: 1/4" = V-0" DRAWING NO:
CROSS REFERENCE: 1/A1 CROSS REFERENCE: 3/Ai 2 BUILDING PERMIT SUBMISSION
8/7/07
1 PROGRESS SUBMISSION 7/31/07
A 1
EO. REVISION/SUBMISSION DATE [DECK PLANS
V?-E7
NOTES u �,
a �
o
u850<
o
a � Ln
1/2" EXT. SHEATHING
FACE FLUSH w/ FACE
OF CONC. SLAB
1/2" CEMENT BOARD w/
OFFSET JOINTS FROM
GENERAL NOTESs SHEATHING JOINTS
2x4'9 O 16" O.C. EFS REINFORCING MESH
1• THE NEW DECKING MATERIAL IS TO BE 5/4 x 6 (1"x 5 1/2") PRE—GROOVED IPE DECKING FOR EMBEDDED IN BASECOAT
USE WITH THE 'IPE CLIP' HIDDEN DECK FASTENER SYSTEM, USE STAINLESS STEEL SCREWS, AS WET SET ANCHOR BOLT
MANUFACTURED AND SOLI) BY WWW.IPEDEPOT.COM EFS FINISH
PT 2x4 SILL PLATE EFS CASING BEAD
2. IT IS RECOMMENDED THAT ALL OF THE DECKING BE STAINED WITH 'AUSTRALIAN TIMBER OIL', 8" 1HK. CONC. SLAB w/ WEEPS
MAHOGANY FLAME, AS MANUFACTURED BY CABOT STAIN COMPANY PRIOR TO INSTALLATION.
SLAB—
w/ #4 BAR REINF'G• CONT. MTL FLASHING
3. ALL IPE DECK BOARDS THAT ARE END CUT DURING INSTALLATION SHALL HAVE ANCHORSEAL, A
WAX LIKE COATING, APPLIED TO THE FRESH END CUT, PRIOR TO FINISH 1/2"
INSTALLATION/ATTACHMENT TO THE JOISTS. -H FINISHED GRADE
4. THE CONTRACTOR IS TO CONSTRUCT THE ROUGH OPENING DIMENSIONS FOR THE 5 BURNER R • I I=I
VERMONT CASTINGS GRILLE, MODEL # VCS500781, PER THE MANUFACTURER'S REQUIREMENTS. 00
AN INSULATED JACKET, MODEL # VCS50001J, WILL BE REQUIRED DUE TO THE ENCLOSURE BEING I I_
COMBUSTIBLE. COORDINATE WITH VERMONT CASTINGS SPECIFICATIONS & DIMENSIONS. 4 ( I
MIN. 6"-8"
5. OPTIONAL ACCESSORIES FOR THE VERMONT CASTINGS FIREPLACE, MODEL # ODSHR42, INCLUDING STONE BASE I_
OUTSIDE AIR TERMINATION KITS AND GLASS DOORS SHALL BE CONFIRMED WITH THE OWNER —I I
PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. I
6. THE STUCCO OR EXTERIOR FINISH SYSTEM SHALL BE INSTALLED BY COMPETENT, EXPERIENCED
INSTALLERS PER THE PRODUCTS MANUFACTURER'S RECOMMENDED INSTALLATION INSTRUCTIONS. - -� —� —�
3 EFS DETAIL AT CONC, SLAB
SCALE:1 CROSS REFERENCE:I/A2
TMS SHALL BE CONSIDERED AN
ORIMAL STAMPED PRINT IF THE
S MATURE IS IN BLUE 1W OVER A
HARD SURFACE,
BACK W SEAL.
MATCH COUNTERTOP 2'-6"f 1. UNAUTHORIZED ALTERATM OR
& HEARTH ADDITION TO TMS DOMU IT IS A
STUD—STUD SQ. VO I ATION OF SECTION 7200
SUBDIVISION 2 OF THE NEW PORK
STATE EDUCATION LAW 02007
COPPER MESH
SPARK ARRESTOR
` - HARD SURFACE,
y%';. •; - -`'r' ';:_,.Y,`. .:.:,.'' MATCH COUNTERTOP
•'' :ti:y'::.,. .:- & HEARTH Lu
VERMONT CASTINGS z �f, •^• .: :...�*-;,�• - :;t':'A'>.''.`.: :. :�1;• '••.
5 BURNER, BUILT IN GRILLE .z c:_.' : ;:..w+. •• �;.,t. �,, •. ..
•. a• ::.. , • •r •,:: s , M
w/ INSULATED JACKET „: •i1' 'i:+���•`',y'.r ::.~'`tip :~:.i ti':,:,.: ><� rt r.' f, ;y,:•r»;;,.;�.=..•a, er'?-� ,+••y O
}. .., ya :•d ;•i�. , rah;. „{ .fit '.J`� . ..
HARD SURFACE io STUCCO FINISH Y J••• +;' ` .
VERMONT CASTINGS i s •.; }
TOP w/ BACKSPLASH COLOR TO MATCH • ,t: ►f •;r + • '~
OUTDOOR WOOD BURN w: '"i` :..•...
ui
CAP FLASHING UNDER STUCCO FINISH WHITE VINYL HANDRAIL FIREPLACE — ODSHR42 '', �..'; _ • ;_•' :'•a.,; :, `•,.• .; ti,..+.► :` ..:��.�''
HARD SURF COLOR TO MATCH :M, r • •:; 1 ~4 r• ;;
ACE OVER & WITH VINYL BALUSTERS CURVED RAISED •`''`� ;. �: t. �`+ ' + ;,; � �~; `� •.: +t.
SHEATHING " :, ,> •.: . ;.,+,. .•'':.. -•r,t. '" ��'• y 4�..
AT 4 O.C. MAX HEARTH it . �. '. ;•„r...,: ., ::..w.` ►.''=k:, •::,'; .:�.,r
•♦ ' ' e���e� .. .t. ..a•. ••_ .ti•, j :' t �• .....••S. .. • '• :•ia.'r•••'• •.:• ::1:.r'+.;.'••1+•a�r'�•r.,.•,,'-!.�•_: ••ti.1,'
= 1/2" EXTERIOR ;.s �. : ` ,..'.;;� =h , .. ,�•• `::"..., a ,`i r =.�: >,: O
SHEATHING I �;:� . x �••�•s i,' :� _ '�:! .. �, : ;�;r;*,• y�N-• :�•,•+•,•� ': �.,. : ..,.
t I •'a• '`;' titca
% •''.t '•':,. �� '�:• 0 "•':..' •�•'. •. a •. ..+.•+:, ? • .• s A:
2x4 s O 16 O.C. I ':•, ' ''
ih TNT. FINISH TO ., a:�..' R :t1• :. `:.••`•.•••r''•. ,. . ti '.,i � �::. ., ..::'.�:. •`• :�:. :., �',
BE DETERMINED _: + : ;..,+r :..;
tt . .. •.•:'; Z
T.O. DECKING : .,�- ;:{ •:. •_. •. s ;w' .1 0
INSTALL FLOOR ', `.
INSIDE AS REQ'D. r. • - ' ' `': WOOD STORAGE W
1'-11" I I •-PROP. LOCAl10N ' ;M•;j:' 1 +
= 3 BURNER SERIES 5/4 x 6" PRE—GROOVED SISTER FRAME 2x8 • '�� •s :: ;a. :=p�,= r. ' �. ��' J? !,.1 W
cc STUD w OF NEW SUPPORT ;.• • .�: .: Y'•'" R •,Q. ;•;. +=a' •,
3 STAIN STL DOORS IPE DECKING w/ IPE CLIP JOISTS TO EXIST'G TYP. ti . '••�;• -" - �' INTERIOR FINISH f Z 0
A2 (VERIFY) BEAM HIDDEN FASTENER SYSTEM ,' ' ' • � �•�'•'' :; _: I .":
" HIDDEN • 415 S FT. HANGERS a:•; •ti ;err ''S � '? TO BE DETERMINED
2 —4 5 BURNER SERIES Q. INSTALL JOIST •'' " + ' ' ;� '`
4 DOWELS Go
EA. END OF NEW JOISTS ,•` :« . •. ,' '• "
ALTERNATING
SLAB STAIN STL DOORS :+` :~� a +• +
CONT. T PROP. LOCATION OF NEW f:: ••
T.O. SLAB 1 OE KICK, DECK SIDE ;. i:. . :: �,• •� '. .:,' .�x t
SUPPORT BEAM +• ,.:...,:r: .; ..; ,�. •!.,. ... r., :�.•:='•r • t ti:`.. . •.. .;:
ELEV. _ —3—6 f' W '7
r o0 m z
I- -r- - r —I- -r — -r- -r - - — T - - - - -i- -i- - - � — � — LIJ (A cc 0
I i I I I I I I V-Or I 4f-6"It I 0'-0"
CRUSHED STONE WRAP NOTE: I I I I ( I
" STONE w/ FILTER FABRIC COORDINATE ACCENT LIGHTING, FIXTURES, CONTROLS.
to HORIZ. & VERT. WALL
4 BARS O.C., LOCATIONS, ETC. w/ OWNER & CONTRACTOR PRIOR
�+ �
TO COMMENCEMENT OF CONSTRUCTION. I I I I I I I I I I I I I I
R M
.nI REINF. I I I I I I I I o I I I I I I W m co
8" DIA. SONOTUBE 'o I I I I I I 1 I
w/ (1) # 4 VERT. BAR I I I I I I ( I I I I I I I PROJECT NO:
I I I I I I I I I ! I I I I DATE : 7/31/07
I I I I I I i I I i I I I I
SCALE : AS NOTED
I I i I I I I I I I I I I I DESIGNED: JAPAONE
B.O. SONOIUBE •° . L J L J L J L J ELEV. _ —9'-2"t �— J 1— J L —1 DRAFTED: JAPAONE
g" 8"
SHEET: 2 of 2
DRAWING NO:
DECK SECTION r2"**N FIREPLACE REAR ELEVATION 2 BUILDING PERMIT SUBMISSION 8/7/07
qQ SCALE:1 2" = 1'-0" //
CROSS REFERENCE:4/A1 CROSS 1REFERENCE:4/A1 1 PROGRESS SUBMISSION 7 31 07
A2
No. REVISION/SUBMISSION DATE SECTIONS & DETAILS
I HEREBY CERTIFY TO
MAP REFERENCE: IRENE A. FITZGERAI D
TERS COMMON SOUTH TRW TITLE INSURANCE 01r NEW YORic, INC. j
THAT THIS MAP WAS MADE FROM AN ACTUAL SURVEY ON
TLAND PARK P.U.D. THE GROUND ACCOROMc. To RECORD oESCFaPmONS AND
rANDUSEN & STEVES SHOWS LOC#XSMCF BOUNDARIES AND IMPROVEMENTS
ON THE JHERE ARE NO ENCROACHMENTS
DRAWER 17 FOLDER 1 cTHER, ai'
• s.
y
•
LECA M. •
DATED: >p�%
LOT 16 of no
. i
GQtv
� S D3-10„
193.50.
� f
c0 .
Q LOT 15 •�°
�Q 31,752.68 s . 6ob
. 6
1
ILL
1.0
ti �)
—__
' ' - cJJ •..�-R s!rw..�, .. ".a S yA.. kyy .. ,{a ,5
v � r
• At tit
y I
t� 4&OF KtlRAl1011 on Iffig NN 10 A swmrf
v1 OW WAMN A UMM LAW >NIRUEVORf VW 4 A
NEW titer MR ONNIM LAU*
156 ,95• ,�� rows Ones mm 1!M doom or go away �
MA M WIN AN 000ft ar 1Nt wo$WrgWft {
N 8'2'fy'OO men St �TO K VMS UK
Kr 1NA°�nc''• i
� y >ta svr�r or►s roorMrm w Aooarawat r=tEr lac �
ceslN1 ON a MAc= MO LAW oAr%TRM ISO= �
By IM WN IM XIX AMOOA110N OF rOMMIM&
LANs o4t%t" s. So wnorc im ft"NUN NLY
1n 1Nt rMrraNr for "m 1NE sWrvty r fwwft AND
~MY. wAs"m m
I have , _ �a} A=[NI.'r AM U7101=M11 tN U=1Eti N8W^ AM
ail ubierj-,
TO 1w A=o" = or we U710=N 11=1rW11 o
shown
z!$w L p,
Porsonatf,� s $
LOT 14 $i,��€ �' MAP OF A SURVEY. MADE FOR
we
�u tic;
SiGI Tit E ALD
--- —"-�` 7
IRENE A. FI-T—ZGZ ."
TOWN OF QUEENSBURY COUNTY OF WARREN N.Y. $
SCALE, 1"=30, DATE, SEPTEMBER 4. 1992
i
VanDusen & Sieves
LAND SURVEYORS,GLENS FALLS,NEV YORK
N.Y. STATE LIC. NO. 35617 '
46--2—