Loading...
2004-053 (2) ace -6C3 Permit Number Lighting and Power Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.4 Release 2c Data filename:C:\Program Files\Check\COMcheck-EZ\QUINN MEDICAL BAYROADLIGHTING.cck Section 1: Project Information Project Name: BAY ROAD SECOND FLOOR ARC FIT-UP Designer/Contractor: BAST HATFIELD 1399 VISCHERS FERRY ROAD CLIFON PARK,NEW YORK 12065-6390 Document Author: BRUNO BATKO Section 2: General Information Building Use Description by: Whole Building Type Building Type Floor Area Office 14976 Project Description(check one): _New Construction _Addition _Alteration _Unconditioned Shell(File Affidavit) Section 3: Requirements Checklist Bldg. Dept. Use [ ] Interior Lighting 1. Total actual watts must be less than or equal to total allowed watts Allowed Watts Actual Watts Complies(Y/N) 19469 17628 YES Exterior Lighting [ ] 2. Type(s)of exterior lighting sources: _Fluorescent _Metal Halide _High-Pr. Sodium Exceptions: Specialized signal,directional,and marker lighting;lighting highlighting exterior features of historic buildings;advertising signage;safety or security lighting;low-voltage landscape lighting. Controls,Switching,and Wiring [ ] 3. Master switch at entry to hotel/motel guest room. [ ] 4. Individual dwelling units separately metered. [ ] 5. Minimum of two switches,dimmer,or occupancy sensor in each space. Exceptions: Only one luminaire in space; Security lighting,24 hour lighting; Lighting Application Worksheet New York State Energy Conservation Construction Code COMcheck-EZ Software Version 2.4 Release 2c Section 1: Allowed Lighting Power Calculation A B C D Total Floor Allowed Allowed Area Watts Watts Building Type (ft2) (watts/ft2) (B x C) Office 14976 1.3 19469 Total Allowed Watts= 19469 Section 2: Actual Lighting Power Calculation A B C D E F Fixture Fixture Description/ Lamps/ #of Fixture ID Lamp Description/Wattage Per Lamp/Ballast Fixture Fixtures Watt. (D x E) 1 48"T8 32W/Electronic 3 181 96 17376 2 48"T8 32W/Electronic 4 2 126 252 Total Actual Watts= 17628 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies. Total Allowed Watts= 19469 Total Actual Watts= 17628 Project Compliance= 1841 Lighting PASSES: Design 9%better than code The area is a corridor,storage,restroom,retail sales area or lobby. [ ] 6. Automatic lighting shutoff control in spaces greater than 250 sq.ft in buildings larger than 5,000 sq.ft. [ ] 7. Photocell/astronomical time switch on exterior lights. Exceptions: Areas requiring lighting during daylight hours [ ] 8. Tandem wired one-lamp and three-lamp ballasted luminaires. Exceptions: Electronic high-frequency ballasted luminaires not on same switch [ ] 9. Transformers meet minimum efficiencies listed in Table 805.6.1 or 805.6.2. Section 4: Compliance Statement The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the New York State Energy Conservation Construction Code requirements in COMcheck-EZ Version 2.4 Release 2c and to comply with the mandatory requirements in the Requirements Checklist. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Principal Lighting Designer-Name Signature D e bf--; ,;2 etA7/ BAST HATFIELD GENERAL CONTRACTORS CONSTRUCTION MANAGERS January 30, 2004 David Hatin Director of Building and Code Enforcement Town of Queensbury 742 Bay Road Queensbury, NY 12804 RE: Permit No. P20030444 Bay Road, Queensbury BHI Project No. 0325 TRANSMITTED: Three (3) Original and stamped drawings for the ARC Tenant Fit-Up Two (2) Signed Energy Compliance Certifications Sincerely, BAST HATFIELD, INC. -;2e2f.().- Stephen W. Adler Project Manager SWA/hs Enc. c: File 1399 Vischers Ferry Road ■ Halfmoon,New York 12065-6325 ■Telephone(518)373-2000■ FAX 373-2303