Signed Inspection Report (03-20-2020).pdfINSPECTION WORKSHEET (SEP-001510-2020)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0625-2018 Case Module:Permit
Inspection Date:Fri Mar 20, 2020 Inspection Status:Partial Pass
Inspector:Charles Dyer Inspection Type:Septic
Job Address:Parcel Number:154 CLEVERDALE RD
Queensbury, NY, 12804
227.17-2-30
Contact Type Company Name Name
Applicant HOFFMAN, JEAN
Framing Contractor Top Notch Builders
Primary Owner Stonewood Development of
Northeastern NY Inc
Granted Permission HOFFMAN, JEAN
Concrete Contractor R. C. Springer Concrete
Architect McLaughlin, Tim
Contractor Stonewood Development of
Northeastern NY Inc
Engineer Environmental Design Partnership, LLC
Checklist Item Status
Building Inspector Notes Failed
Public Sewer Sign-Off Failed
Roof gutters don't discharge over leach field Failed
Mar 20, 2020 Page (1)
INSPECTION WORKSHEET (SEP-001510-2020)
Checklist Item Status
Soil Type: Clay Failed
Type of Water: Municipal / Well Water Passed
Well
Well separation distance Passed
100+ ft
Absorbtion Fields: Total Length Passed
2 ELJEN runs @ 40 ft each = 80ft
Length of Each Trench Passed
ELJEN Matts 80 ft
Size of Stone Passed
Matts sit on washed sand
Building to Tank Passed
4" schd 40
Tank to Distribution Box Passed
4" SDR 35
Distribution box to Field / Pit Passed
4"SDR 35 perforated
Foundation to Tank Passed
10'2"
Foundation to Absorption Passed
26'4"
Engineer Report and As-Built Failed
Mar 20, 2020 Page (2)
INSPECTION WORKSHEET (SEP-001510-2020)
Checklist Item Status
Engineer onsite taking measurements, will provide asbuilt
Location of system on property Passed
Off front porch
Mar 20, 2020 Page (3)
Dyer, Charles