Loading...
Signed Inspection Report (03-20-2020).pdfINSPECTION WORKSHEET (SEP-001500-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:SEP-0116-2020 Case Module:Permit Inspection Date:Fri Mar 20, 2020 Inspection Status:Passed Inspector:Charles Dyer Inspection Type:Septic Job Address:Parcel Number:37 BROADACRES RD Queensbury, NY, 12804 302.18-2-63 Contact Type Company Name Name Granted Permission IBS Septic Applicant Cavas, Matthew Contractor IBS Septic Primary Owner Cavas, Matthew Checklist Item Status Building Inspector Notes Failed Type of Water: Municipal / Well Water Passed Municipal Absorbtion Fields: Total Length Passed Stone bed system 20x25 Length of Each Trench Passed Each run is 20 ft x 4 and looped on ends Depth of Trenches Passed Bed is roughly 24"+ in depth Size of Stone Passed Mar 20, 2020 Page (1) INSPECTION WORKSHEET (SEP-001500-2020) Checklist Item Status # 2 Building to Tank Passed 4" schd 40 Tank to Distribution Box Passed 4" SDR 35 Distribution box to Field / Pit Passed 4" SDR 35 perforated End Cap Passed Ends are looped InletOutlet Pipes & Baffles Passed Effluent filter on outlet end Foundation to Tank Passed Fiber 1250 gal tank 10 ft from foundation Foundation to Absorption Passed 21 ft Location of system on property Passed Front yard Mar 20, 2020 Page (2) Dyer, Charles