Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Manual J
erat Project Summary Date:Feb 04,2020EntireHouseBy:Adirondack P&M,Inc.=Adirondack P&M PO Box $62,Glens Fas.NY 12801 Phone:518.753 3863_Emal:nfo@udrondackpm com Project Information - For.Monsour Large Ranch 308.18-1-43 RC-0100-2020 |E Monsour Enterprises LLC|)notes:24 Brookshire Trce)|MAR 11 2020 SFD w/gas FP 1703 s.f.,Gar.576 sf. UOTE Ts LM abcedaue ieee) Weather:Glens Falls AP,NY,US Winter Design Conditions Summer Design Conditions Outside db 4 °F Outside db 85Insidedb68°F Inside db 75 °F Design TD 2 °F Design TD.10 °F Daily range M Relative humidity 50 % Moisture difference 26 grilb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29271 tun Structure 14377 Btuh Ducts O Btuh Ducts O BtuhCentralvent(0 cfm)0 Btuh Central vent (0 cfm)0 Btuh (none)(none)Humidification 8 Btuh Blower 0 Btuh Piping BtuhEquipmentload20xBtuh Use manufacturer's data Ratefswing multiplier 0.90InfiltrationEquipmentsensibleload12939 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionquality‘Average Fireplaces 1 (Average)Structure 5980 Btuh Ducts O Btuh Central vent (0 cfm)0 Btuh Heating Colin,(none)Area (f)‘3748 ‘374!Equipment latent load 5980 Btuh Volume (f)9 0 Air changes/hour 0.90 0.40 Equipment Total Load (Sen+Lat)18919 Btuh Equiv.AVF (cfm)0 0 Req.total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Amana Make Amana Trade /AMANA HEATING AND AIR CONDITIO.Trade ‘AMANA Model ‘AMSS960402BN Cond ASX130181D AHRI ref 7368085 Galt ACNF180016D AHRI ref 5996190 Efficiency 96.1 AFUE Efficiency 10.8 EER,13 SEER Heating input 40000.Btuh Sensible cooling 11760 Btuh Heating output 38000 Btuh Latent cooling 5040 Btuh Temperature rise 62 °F Total cooling 48800 Btuh Actual air flow 560 cim Actual air flow 560 cim Air flow factor 0.019 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure ©inH20 Static pressure ©inH20 ‘Space thermostat Load sensible heat ratio 0.71 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. he wrightsore an20Feb04 103827MEHOMESOFEgycuteUniversal201919.0.08 RSU21842 Page|comentsvhighson HVACMonsourRancnSGF201B;up Cale =MU7 Front Ooot faces:WW AONPAC,Manual S Compliance Report poe:seb 6a 020edNyEntireHouseBy:Adirondack P&M,Inc. Adirondack P&M 0 Box $62,Gens Falls,NY 12801 Phone:S18789-0889 Ema:fo@edrondackm com eoreduee el For:Monsour Large Ranch Cooling Equipment Design Conditions utdoor design DB:85.Sensible gain:14377 Btuh Entering coil DB:75.0°F Outdoor design WB:70,Latent gain 5980 Btuh Entering coil WB:62.5°F Indoor design DB:75.0°F Total gain 20357 Btuh Indoor RH:50%Estimated airflow:622 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type:Split AC Manufacturer.Amana Model:ASXC160241C ‘Actual airflow:560 cfm Sensible capacity:11760 Btun 82%of load Latent capacity:5040 Btuh 84%of load Total capacity:16800 Btuh 83%of load.SHR:70% Heating Equip Design Conditions Outdoor design DB:-3.5°F Heat loss:29271 Btuh Entering coll DB:68.0°F Indoor design DB:68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type:Gas furnace Manufacturer:Amana Model:AMVC960603BN Actual airflow:560 cfm Output capacity:$8000 Btuh 130%of load Temp.rise:50 °F Meets all requirements of ACCA Manual S. +-0 Feb04 03827=WFIGMESOFE®pignt suo Univorsl 2019 19.0.08 RSUZI049 Pepe umentsvtignson HVACMonsourRanchSGF201B,up Calc =Mu?FrontDoor faces:W