Loading...
ResCheck r 9 c eck SoftwareVersion Compliance Certificate rri 00 Project Cerrone Builders Inc 00 a) Energy Code: 2015 IECC � l!! 0 Location: Glens Falls, NeV IME C E 0 E G { Construction Type: Single-family , Project Type: New Constructi Conditioned Floor Area: 1,412 ft2 JF 14 2017 y J cn Glazing Area 16% N N 7 Climate Zone: 6 (7635 HDD) 'OWN OF QUEENSBURY VL Permit Date: BUILDING&CODES O T d' Permit Number: 4 CD t6 0- Construction Site: Owner/Agent: Designer/Contractor: p N 3 West Mountain Sub Phase 1 VISION Engineering, LLC r 0 Q Lot 12 206 Glen Street L6 U_ Queensbury, NY 12801 Ste 56 f V (n Glens Falls, NY 12801 M (518) 792-9264 a!npliance: 1.7%Better Than Code Maximum ILIA: 241 Your UA: 237 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont� Assembly or R-Value R4411tit 13-Factor UA Perimeter Ceiling 1: Raised or Energy Truss 1,412 38.0 0.0 0.025 35 Wall 1: Wood Frame, 16" o.c. 1,449 21.0 0.0 0.057 69 Window 1: Vinyl Frame:Double Pane with Low-E 152 0.290 44 Door 1: Front: Solid 20 0.200 4 Door 2: Back: Glass 40 0.290 12 Door 3: Fire Door: Solid 18 0.140 3 Basement Wall 1: Solid Concrete or Masonry 1,256 0.0 15.0 0.046 56 Wall height: 7.8' Depth below grade: 6.8' Insulation depth: 7.8' Window 2: Wood Frame:Double Pane 9 0.400 4 Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 33 0.290 10 Floor 1:All-Wood joist/Truss:Over Outside Air 12 30.0 0.0 0.033 0 Project Title: Cerrone Builders Inc Report date: 09/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES -CER Page 1 of 10 WM Lot 12\1279 RESCHECK.rck c eck SoftwareVersion Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section -� Plans Verified Field Verified # Pre-Inspection/Plan Review Valise value ComFtli �?� rner s`Assu prtions qp 111)3 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑ [PR1]1 energy code compliance for the Does Not building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. ,��. „ 103.1, Construction drawings and i.,, ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR31i lighting and mechanical systems. -]Not Observable Systems serving multiple `❑Not Applicable dwelling units must demonstrate I compliance with the IECC Commercial Provisions. ." k WHeating and cooling equipment is Heating: Heating: ❑Complies sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr [-]Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) ''2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 09/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES - CER Page 3 of 10 WM Lot 12\1279 RESCHECK.rck f Section I Flans Verified �FielderifiedFrarming/ Rough-in Inspection Value lueCorslplies? Comments, ,ss s ptions 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assem blies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable i❑Not Applicable 402.1.1, Glazing U-factor(area-weighted ! U- U- ❑Complies ;See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR211 303.1.3 :U-factors of fenestration products 'y ❑Complies [FR4]1 are determined in accordance []Does Not .with the NFRC test procedure or N taken from the default table. ❑ of Observable , ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies 3 [FR23]1 'installed per manufacturer's % ❑Does Not instructions. `z [-]Not Observable , ❑Not Applicable 402.4.3 Fenestration that is not site built , ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ; or has infiltration rates per NFRC []Not Observable ; 400 that do not exceed code , ❑Not Applicable limits. .; _ 402.4 5 IC-rated recessed lighting fixtures }[FR16]2 sealed at housing/interior finish „ ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. a 4 ❑Not Observable ❑Not Applicable ; 403.2.1 Supply and return ducts in attics IEComplies [FR12]1 insulated >= R-8 where duct is qr s ❑Does Not >= 3 inches in diameter and >_ -]No t Observable R-6 where< 3 inches.Supply and return ducts in other portions of y ❑Not Applicable j the building insulated >= R-6 for diameter>= 3 inches and R-4.2 NP for< 3 inches in diameter. , _ 403.3.3.5 Building cavities are not used as �� a �� � � ❑Complies [FR15]3 ducts or plenums. ❑Does Not ] �q, ❑Not Observable ' []Not Applicable 1403.4 HVAC piping conveying fluids R- R- ❑Complies ![FR17]2 above 105 4F or chilled fluids ❑Does Not I below 55 4F are insulated to>_R- 3 ❑Not Observable ; .[]Not Applicable j .403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 103.5 ;Hot water pipes are insulated to R- R � ❑Complies [FR1812 �R-3. ❑Does Not ❑Not Observable ; ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies Rxs1z installed on all outdoor air []Does Not intakes and exhausts. []Not Observable ❑Not Applicable 11 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title; Cerrone Builders Inc Report date: 09/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES - CER Page 5 of 10 WM Lot 12\1279 RESCHECK.rck Section .. ppppqq _. PlansVerified Field Verified Insulation Inspection Co > Comments/Assumptions!alue Vale �3031 ."" All installed insulation is labeled ❑Complies [IN13]2 'or the installed R-values ❑Does Not provided. t ❑Not Observable ; i ' IN n❑Not Applicable 402.1.1, "i Floor insulation R-value. R- R- "Complies See the Envelope assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not ;table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, ;Floor insulation installed per ❑Complies 9 4.�{ Smq� �: 402.2.7 manufacturer's instructions and 4=� : ❑Does Not [IN2]1 in substantial contact with the �$t. underside of the subfloor, or floor ❑Not Observable framing cavity insulation is in a ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and k extends from the bottom to the %X top of all perimeter floor framing members. � �x w 402.1.1, 'Wall insulation R-value. If this is a R- R- ❑Complies :See the Envelope Assemblies 402.2.5, mass wall with at least Vz of the ❑ Wood ❑ Wood ❑Does Not i table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ;[-]Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. []Does Not -]Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 09/06/17 Data filename: C:\Users\Irobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES-CER Page 7 of 10 WM Lot 12\1279 RESCHECK.rck Section Flans Verified` Field Verified # Final Inspection Provisions Complies? Comments/Assumptions & Req.ID Value Value 403.6.1 All mechanical ventilation system @M ❑Complies [F[25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ,, ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ' ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback a control to lower boiler water ;, ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403,5.1,1 Heated water circulation systems ❑Complies [F12812 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply a ❑Not Observable pipe. Gravity and thermos ❑Not Applicable syphon circulation systems are not present. Controls for Y circulating hot water system pumps start the pump with signal for hot water demand within theURI '. occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5,1,2 Electric heat trace systems ❑Complies [F12912 comply with IEEE 515.1 or UL -]Does Not 515. Controls automatically ❑Not Observable adjust the energy input to the y ME ❑Not Applicable heat tracing to maintain the PP desired water temperature in the Piping. __.... ._.................. _......................................__. ..__ _ .._... ._ ..... 403.5.2 Water distribution systems that ���,, ❑Complies [F130]2 ' 'have recirculation pumps that ❑Does Not pump water from a heated water ❑Not Observable supply pipe back to the heated water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units 3a� ❑Complies [F131]2 tested in accordance with CSA ❑Does Not 655.1. Potable water-side ' pressure loss of drain water heat ❑Not Observable ❑Not A licable recovery units < 3 psi for PP :individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. • 404.1 75%of lamps in permanent ❑Complies [F1611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage [-]Not Observable lighting. ❑Not Applicable 404,1.1 Fuel gas lighting systems have ;,❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable n ❑Not Applicable 1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Cerrone Builders Inc Report date: 09/06/17 Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES - CER Page 9 of 10 WM Lot 12\1279 RESCHECK.rck f t 2015 IECC Energy Efficiency Certificate Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHGC Window 0.29 Door 0.29 Heating Cooling Equipment Heating System• Cooling System: Water Heater: Name: Date: Comments