ResCheck r
9
c eck SoftwareVersion
Compliance Certificate
rri
00
Project Cerrone Builders Inc
00 a)
Energy Code: 2015 IECC � l!! 0
Location: Glens Falls, NeV
IME C E 0 E G {
Construction Type: Single-family ,
Project Type: New Constructi
Conditioned Floor Area: 1,412 ft2 JF 14 2017 y J cn
Glazing Area 16% N N
7
Climate Zone: 6 (7635 HDD) 'OWN OF QUEENSBURY VL
Permit Date:
BUILDING&CODES O T
d'
Permit Number: 4 CD t6 0-
Construction Site: Owner/Agent: Designer/Contractor: p
N 3
West Mountain Sub Phase 1 VISION Engineering, LLC r 0 Q
Lot 12 206 Glen Street L6 U_
Queensbury, NY 12801 Ste 56 f V (n
Glens Falls, NY 12801 M
(518) 792-9264
a!npliance: 1.7%Better Than Code Maximum ILIA: 241 Your UA: 237
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont�
Assembly or R-Value R4411tit 13-Factor UA
Perimeter
Ceiling 1: Raised or Energy Truss 1,412 38.0 0.0 0.025 35
Wall 1: Wood Frame, 16" o.c. 1,449 21.0 0.0 0.057 69
Window 1: Vinyl Frame:Double Pane with Low-E 152 0.290 44
Door 1: Front: Solid 20 0.200 4
Door 2: Back: Glass 40 0.290 12
Door 3: Fire Door: Solid 18 0.140 3
Basement Wall 1: Solid Concrete or Masonry 1,256 0.0 15.0 0.046 56
Wall height: 7.8'
Depth below grade: 6.8'
Insulation depth: 7.8'
Window 2: Wood Frame:Double Pane 9 0.400 4
Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 33 0.290 10
Floor 1:All-Wood joist/Truss:Over Outside Air 12 30.0 0.0 0.033 0
Project Title: Cerrone Builders Inc Report date: 09/06/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES -CER Page 1 of 10
WM Lot 12\1279 RESCHECK.rck
c eck SoftwareVersion
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
-�
Plans Verified Field Verified
# Pre-Inspection/Plan Review Valise value
ComFtli �?� rner s`Assu prtions
qp 111)3
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑
[PR1]1 energy code compliance for the Does Not
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents. ,��. „
103.1, Construction drawings and i.,, ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR31i lighting and mechanical systems. -]Not Observable
Systems serving multiple `❑Not Applicable
dwelling units must demonstrate I
compliance with the IECC
Commercial Provisions. ."
k WHeating and cooling equipment is Heating: Heating: ❑Complies
sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not
on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods Btu/hr Btu/hr [-]Not Observable
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
111 High Impact(Tier 1) ''2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 09/06/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES - CER Page 3 of 10
WM Lot 12\1279 RESCHECK.rck
f Section
I Flans Verified �FielderifiedFrarming/ Rough-in Inspection Value lueCorslplies? Comments, ,ss s ptions
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assem blies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
i❑Not Applicable
402.1.1, Glazing U-factor(area-weighted ! U- U- ❑Complies ;See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR211
303.1.3 :U-factors of fenestration products 'y ❑Complies
[FR4]1 are determined in accordance []Does Not
.with the NFRC test procedure or N
taken from the default table. ❑ of Observable ,
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies 3
[FR23]1 'installed per manufacturer's % ❑Does Not
instructions. `z
[-]Not Observable ,
❑Not Applicable
402.4.3 Fenestration that is not site built , ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440 ;
or has infiltration rates per NFRC []Not Observable ;
400 that do not exceed code , ❑Not Applicable
limits. .; _
402.4 5 IC-rated recessed lighting fixtures
}[FR16]2 sealed at housing/interior finish „ ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. a 4 ❑Not Observable
❑Not Applicable ;
403.2.1 Supply and return ducts in attics IEComplies
[FR12]1 insulated >= R-8 where duct is qr s ❑Does Not
>= 3 inches in diameter and >_
-]No
t Observable
R-6 where< 3 inches.Supply and
return ducts in other portions of y ❑Not Applicable j
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2 NP
for< 3 inches in diameter. , _
403.3.3.5 Building cavities are not used as �� a �� � � ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
] �q, ❑Not Observable '
[]Not Applicable
1403.4 HVAC piping conveying fluids R- R- ❑Complies
![FR17]2 above 105 4F or chilled fluids ❑Does Not
I below 55 4F are insulated to>_R-
3 ❑Not Observable ;
.[]Not Applicable j
.403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
103.5 ;Hot water pipes are insulated to R- R � ❑Complies
[FR1812 �R-3. ❑Does Not
❑Not Observable ;
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
Rxs1z installed on all outdoor air []Does Not
intakes and exhausts.
[]Not Observable
❑Not Applicable
11 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title; Cerrone Builders Inc Report date: 09/06/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES - CER Page 5 of 10
WM Lot 12\1279 RESCHECK.rck
Section ..
ppppqq _. PlansVerified Field Verified
Insulation Inspection
Co > Comments/Assumptions!alue Vale
�3031 ."" All installed insulation is labeled ❑Complies
[IN13]2 'or the installed R-values ❑Does Not
provided. t
❑Not Observable ;
i '
IN n❑Not Applicable
402.1.1, "i Floor insulation R-value. R- R- "Complies See the Envelope assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not ;table for values.
[IN1]1 ❑ Steel ❑ Steel ❑Not Observable
❑Not Applicable
303.2, ;Floor insulation installed per ❑Complies
9 4.�{ Smq� �:
402.2.7 manufacturer's instructions and 4=� : ❑Does Not
[IN2]1 in substantial contact with the �$t.
underside of the subfloor, or floor ❑Not Observable
framing cavity insulation is in a ❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and k
extends from the bottom to the %X
top of all perimeter floor framing
members. �
�x w
402.1.1, 'Wall insulation R-value. If this is a R- R- ❑Complies :See the Envelope Assemblies
402.2.5, mass wall with at least Vz of the ❑ Wood ❑ Wood ❑Does Not i table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ;[-]Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. []Does Not
-]Not Observable
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact(Tier 1) Medium Impact(Tier 2) Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 09/06/17
Data filename: C:\Users\Irobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES-CER Page 7 of 10
WM Lot 12\1279 RESCHECK.rck
Section Flans Verified` Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
& Req.ID Value Value
403.6.1 All mechanical ventilation system @M ❑Complies
[F[25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. ,, ❑Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ' ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback a
control to lower boiler water ;, ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403,5.1,1 Heated water circulation systems ❑Complies
[F12812 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply a ❑Not Observable
pipe. Gravity and thermos ❑Not Applicable
syphon circulation systems are
not present. Controls for Y
circulating hot water system
pumps start the pump with signal
for hot water demand within theURI
'.
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5,1,2 Electric heat trace systems ❑Complies
[F12912 comply with IEEE 515.1 or UL
-]Does Not
515. Controls automatically ❑Not Observable
adjust the energy input to the y ME ❑Not Applicable
heat tracing to maintain the PP
desired water temperature in the
Piping.
__.... ._.................. _......................................__. ..__ _ .._... ._ .....
403.5.2 Water distribution systems that ���,, ❑Complies
[F130]2 ' 'have recirculation pumps that ❑Does Not
pump water from a heated water ❑Not Observable
supply pipe back to the heated
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units 3a� ❑Complies
[F131]2 tested in accordance with CSA ❑Does Not
655.1. Potable water-side '
pressure loss of drain water heat ❑Not Observable
❑Not A licable
recovery units < 3 psi for PP
:individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers. •
404.1 75%of lamps in permanent ❑Complies
[F1611 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage [-]Not Observable
lighting. ❑Not Applicable
404,1.1 Fuel gas lighting systems have ;,❑Complies
[F123]3 no continuous pilot light. ❑Does Not
❑Not Observable
n ❑Not Applicable
1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 09/06/17
Data filename: C:\Users\lrobision\Dropbox\VISION Engineering, LLC\Active Projects VE\1279 - DES - CER Page 9 of 10
WM Lot 12\1279 RESCHECK.rck
f
t
2015 IECC Energy
Efficiency Certificate
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 30.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Door Rating U-Factor SHGC
Window 0.29
Door 0.29
Heating Cooling Equipment
Heating System•
Cooling System:
Water Heater:
Name: Date:
Comments