Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ResCheck
• • oDou>I r. REScheck Software Version 4.5,5 1 x c.i. Compliance Certificate an cn .` N cn Co to Project Stokes - 1900709 FILE COPY g° - o Energy Code: 2015 IECC �, 7 Location; Glens Falls, New York ..• CI Construction Type: Single-family __-__ (,� C Project Type: New Construction D ( 1 Conditioned Floor Area; 4,084 ft2 - to Glazing Area 22% Climate Zone: 6 (7635 HDD) APR 12 2019 : N O Permit Date: ....1W Permit Number. TOWN OF QIUEEN BU EY -"' BUILDING&CODES -_-- Construction Site: Owner/ DEST6ner/Contractor: 45 Alessia Drive Jim &Donna Stokes Gerald Johnson Queensbury,NY 12804 870 Parson Forest CV Southland Log Homes Cordova,TN 38018 PO Box 1668 Irmo,SC 29063 Compliance:Passes using UA trade-off Compliance 1.8%Better Than Code Maximum UA. 445 Your UA 437 The%Better or Worse Than Code Index reflects how dose to compliance the house Is based on code trade-off ru es it DOES NOT provide an estimate of energy use or cost relative to a minlmum•code home. REVIEWED E\ IEWED F O R Envelope Assemblies ENERGY CODE COMPLIANCE Gross Area Assembly or Cavity Cont. U-Factor UA Perimeter R-Value R-Value Ceiling 1: Flat Ceiling or Scissor Truss 1,232 49.0 0.0 0.026 32 Ceiling 2:Cathedral Ceiling 1,244 49.0 0.0 0.022 27 Log Wall:Log: EWP,8 inch 1,620 0-0 0.0 0.087 108 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 240 0.290 70 Door 1:Glass 20 0.260 5 Door 2:Glass 120 0.260 31 Gable LogWall: Log:EWP,8 inch 242 0.0 0.0 0.087 15 Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 72 0.290 21 Conventional Wall:Wood Frame, 16"o.c. 346 13.0 10.0 0.044 14 Window 3,Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.290 4 Door 3: Solid 20 0.140 3 Basement Wall• Solid Concrete or Masonry 2,475 19.0 0.0 0.042 103 Wall height: 10.0' Depth below grade:9.0' Insulation depth: 10.0' Window 4 Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0,790 4 Project Title: Stokes - 1900709 Report date: 04/11/19 Data filename: G:\Cadhold\RES Check\Stokes1900709.rck Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in FIEScheck Version 4.6.5 and to comply with the mandatory requirements listed in th REScheck Inspection Checklist. Gt rt/d .del r�.,� /kJ. Name-Title Signature Date Project Title: Stokes- 1900709 Report date: 04/11/19 Data filename: G:1Cadhold\RES Check\Stokes1900709.rck Page 2 of10 0 T REScheck Software VersionChecklist 4.6.5 Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions"column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section ! Plans Verifled Field Verified # f Pre-Inspection/Plan Review e pComments/Assumptions &Req.113 t Value KK Value . . . 1_,.. . ,-.._.�-1_ ... .q Complies? I _ 103.1, Construction drawings and OCom lies ,103.2 documentation demonstrate ['Does Not I(PR111 energy code compliance for the QNot Observable I building envelope.Thermal envelope represented on ONot Applicable construction documents. c 103.1, Construction drawings and OCompties 103.2, documentation demonstrate ['Does Not 403.7 energy code compliance for J (PR311 lighting and mechanical systems. :Not Observable 1 I Systems serving multiple [Not Applicable 4 dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ['Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr woes Not 1PR212 on loads calculated per ACCA Cooling: Cooling: QNot Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 11High Impact(Tier 1) l 2 Medium impact(Tier 2) � ' Low Impact(Tier 3) Project Title: Stokes- 1900709 Report date: 04/11/19 Data filename: G:\Cadhold\RES Check\Stokes1900709.rck Page 3 of10 • Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions 402,1.1 Conditioned basement wall R- R- ©Complies See the Envelope Assemblies (F0411 insulation R-value.Where interior R. R ❑Does Not table for values. insulation is used,verification ONot Observable may need to occur during Insulation Inspection.Not ONot Applicable 1 required in warm-humid locations in Climate Zone 3 303,2 Conditioned basement wall $®Complies [FO511 insulation installed per ',ODoes Not t manufacturer's instructions. jQNot Observable .ONot Applicable 402.2.9 Conditioned basement wallft ft ❑Complies See the Envelope AssembliesS (FO61' insulation depth of burial or ODoes Not table for values. distance from top of wall. ONot Observable :Not Applicable 303 2 1 A protective covering is installed OCornplies ( [FO1112 to protect exposed exterior Oboes Not 4 insulation and extends a f "ONot Observable minimum of 6 in,below grade, ONot Applicable 403,9 Snow-and ice-melting system 40Complies (F0121z "'controls Installed. ODoes Not j IQNot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) i 3 .Low Impact(Tier 3) Project Title: Stokes- 1900709 Report date: 04/11/19 Data filename: G:\Cadhold\RES Check\Stokes1900709.rck Page 4 of10 . Section ° Plans Verified Field Verified Com ties? Comments/Assumptions Framing/Rough-In inspection Value Value P &Re fiJ 1402.1.1, Door U-factor. U- U- OComplies See the Envelope Assemblies 402.3.4 ODoes Not table far values [FR111 ONot Observable ONot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- OComplies See the Envelope Assemblies 402.3.1, average). ODoes Not table for values. 402.3.3, ONot Observable 402.5 (FR2)' ONot Applicable (F v 303.1,3 U-factors of fenestration products ,OComplies (FR4)' are determined in accordance ODoes Not with the NFRC test procedure or ®Not Observable ONot Applicable taken from the default table. 402.4.1,3 Air barrier and thermal barrier ❑Complies (FR23(' installed per manufacturer's ODoes Not instructions. ®Not Observable 'ONot Applicable 402.4.3 Fenestration that is not site built OComplies IFR2OP is listed and labeled as meeting ODoes Not AAMA/WDMA/CSA 101/I.5.2/A440 ®Not Observable or has infiltration rates per NFRC 400 that do not exceed code ONot Applicable t_ limits. 402.4.5 IC-rated recessed lighting fixtures OComplies IFR1612 sealed at housing/interior finish ,ODoes Not and labeled to indicate 2.0 cfm ONot Observable leakage at 75 Pa. ONot Applicable 403.3.1 Supply and return ducts in attics OComplies (FR12)1 insulated>=R-8 where duct is ODoes Not >=3 inches in diameter and>= f, R_{where< 3 inches.Supply and ONot Observable return ducts in other portions of ONot Applicable the building insulated>=R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies (FR15]3 ducts or plenums. ODoes Not ONot Observable ONot Applicable 403,4 HVAC piping conveying fluids R- R Complies [FR1712 above 105 QF or chilled fluids ODoes Not below 55 oF are insulated to a R- ONot Observable 3. ONot Applicable 403.4.1 Protection of insulation on HVAC "❑Complies (FR24)1 piping. ,ODoes Not ONot Observable ONot Applicable 403.5.3 Hot water pipes are insulated to R- R- OComplies ,(FR18J2 ?R-3. ODoes Not V, ONot Observable ONot Applicable 403.6 Automatic or gravity dampers are OComplies (FR19P installed on all outdoor air ®Does Not intakes and exhausts. ONot Observable ONot Applicable 0 High Impact(Tier 1) J 2 Medium Impact(Tier 2) -I 3 1Ltrw Impact(Tier 3) Project Title: Stokes- 1900709 Report date: 04/11/19 Data filename: G:1Cadhold\RES Check\Stokes1900709.rck Page 5 of10 Additional Comments/Assumptions: 1 iH g pact iTier 1} 2 Medium Impact(Tier 2) ( 3_11-aw Impact(Tier 3) Project Title: Stokes- 1900709 Report date: 04/11/19 Data filename: G:1Cadhold\RPS Check\Stokes1900709.rck Page 6 of10 ` . . . . Section insulation inspection Plans Verlfied�' Field Verified Complies? Comments/Assumptions # Val e Value &R ID[ u 303.1 ":All installed insulation is labeled nl)oes Not [INI312 or the installed R-values provided. ,nNot Observable TINot Applicable 4021.1, Wall insulation R-value,if this is a R- R- OComplies See the Envelope Assembffe-,i 11,402.2.5, mass wall with at least lb of the n Woo I d F Wood 0Does Not table for values, j402.2.6 wall insulation on the wall E] Mass Mass C]Not Observable [IN311 exterior.the exterior insulation E] Steel Steel CINot Applicable requirement applies(FRIO). 303.2 Wall Insulation is installed per -�01)oes Not [IN411 manufacturer's instructions. IONot Observable "ONot Applicable Additional ^ �^ �Jr _ '�� npact — (Tier 1) nier3) -_J Project Title- Stokes- IQOO70§ Report date: 04/11/I9 • Section ' Plans Verified Field Verified # Final inspection Provisions Value Value Complies? Comments/Assumptions 402.1.1, Ceiling insulation R-value. R R OComplies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ODoes Not table for values. 402.2.2, ❑ Steel 0 Steel ONot Observable 402.2.6 [Fi1]1 ONot Applicable 1303.2 - �_- —a _ 303 1.1.1, Ceiling insulation installed per ,©Complies manufacturers instructions. t t©Does Not [FI2]1 Blown insulation marked every t ONot Observable 300 ft'. ONot Applicable 402.2.3 Vented attics with air permeable f ,� ,- .r = , ,OComplies [F122J2 ;insulation include baffle adjacent s r:� ODoes Not 'to soffit and eave vents that is. �: ;..:� w n. =i ©Not Observable extends over insulation. .�...-_,',ONot Ap plicable 402.2.4 Attic access hatch and door R- R- OComplies [F13P insulation a R-value of the Oboes Not adjacent assembly. ONot Observable ONot Applicable 402.4.1.2 Blower door test @ 50 Pa.<=5 ACH 50= ACH 50= OComplies [F117]1 ach in Climate Zones 1-2,and ODoes Not <=3 ach in Climate Zones 3-8. - ONot Observable I ONot Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 !]Complies [FI4]1 cfm/100 ft2 across the system or ft2 Oboes Not ONot Observable ONot Applicable <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in tests,verification may need to occur during Framing inspection. 403.3.3 Ducts are pressure tested to cfmt100 cfm/100 ©Complies [FI27]1 determine air leakage with ft2 ft2 ODoes Not either:Rough-in test:Total leakage measured with a ONot Observable pressure differential of 0.1 inch ONot Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test,Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g,across the entire system including the manufacturer's air h ndler enclosure. 4F 3 2,1 Air a manufacturerlerleakage designated f d . ODo mplies Not _9 [ by s design air flow. - t i ` ;10Not Observable ONot Applicable 403.1.1 Programmable thermostats l, IOComplies (F1912 installed for control of primary Oboes Not heating and cooling systems and I initially set by manufacturer to ,ONot Observable code specifications. ;ONot Applicable 403.1,2 Heat pump thermostat installed i®Complies '[FI10P -!on heat pumps. Oboes Not ONot Observable 1ONot Applicable . _ v .,. ,. 403.5,1 ,Circulating service hot water _ s ®Complies [Fll1]2 ,systems have automatic or 1ODoes Not ;accessible manual controls. i ,( Not Observable 40Not Applicable 11 High Impact(Tier 1) 2 ;Medium Impact(Tier 2) 3 .Low Impact(Tier 3) Project Title: Stokes- 1900709 Report date: 04/11/19 Data filename: G:\Cadhold\RES Check\Stokes1900709.rck Page 8 of 10 . . . . ° ^ , — � Plans Verified Field Verified Final Inspection Provisions I Complies? Comments/Assumptions Value Value 403,6.2 All mechanical ventilation system OComplies [FI2512 fans not part of tested and listed ElDoes Not HVAC equipment meet efficacy [INot Observable and air flow limits. �ONot Applicable water boilers supplying heat if [F12612 through one-or two-pipe heating �E]Does Not systems have outdoor setback I]Not Observable control to lower boiler water UNot Applicable temperature based on outdoor 403.5J1 Heated water circulation systems �ODoes Not EF12812 have a circulation pump.The system return pipe is a dedicated return pipe or a cold water supply' 'C]Not Observable !C]Not Applicable pipe.Gravity and thermos- syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. ocomplies 401il,2 'Electric heat trace systems 515,Controls automabcally []Not Observable adjust the energy input to the 'ONotApplicable heat tracing to maintain the desired water temperature in the ,�0_3.5.2 Water distribution systems that ocomplies i JFI3012 have recirculation pumps that E]Does Not pump water from a heated water []Not Observable supply pipe back to the heated water source through a cold ONot Applicable water supply pipe have a demand recirculation water system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. —4 403.5.4 Drain water heat recovery units OComplies [F13112 tested in accordance with CSA 0Does Not B55.1.Potable water-side C]Not Observable pressure loss of drain water heat recovery units< 3 psi for ONot Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to �404.1 75%of lamps in permanent Elcomplies IF1611 fixtures or 75%of permanent �[]Does Not fixtures have high efficacy lamps. C3Not Observable Does not apply to low-voltage 11Not Applicable ClComplies '404.1-1 Fuel gas lighting systems have IF12313 no continuous pilot light. E]Does Not ONot Observable 0Not Applicable —3`__� . l _ � 3 2) | 3 .Lmw ���� � Project Title; Stokes' 1g007O9 Report date: 04/11/I9 0mtafi|enepne: G:\[adho|d\RESCheck\StakesI900709'nck Page @of1O Plans Verified Field Verified # Final Inspection Provisions Complies? Comments/Assumptions Value Value &Rert.IO 401.3 Compliance certificate posted. OComplies (F1712 ODoes Not :Not Observable DNot Applicable 303.3 Manufacturer manuals for °Complies 'AMP mechanical and water heating ODoes Not systems have been provided. ElNot Observable CiNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) --r-i-pwrt--1—Ipact(1--"Te71)-1 Project Title: Stokes-1900709 Report date: 04/11/19 Data filename: G:\Cadhold\RES Check\Stokes1900709.rck Page 10 of10 2 }15 C Enr Effie n� r e - ate Insulation Rating R-Value Above-Grade Wall 0.00 Below-Grade Wail 19.00 Floor o.00 Ceiling J Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.26 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments