ResCheck c eck Software Version
Compliance CertificateLVJ —
D
i
Project Cerrone Builders Inc NOV 15 2017
Energy Code: 2015 IECC TOWN OF QUEENSBURY
Location: Glens Falls, New York
COMMUNITY DEVELOPMENT
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 1,986 ft2 315.10-1-40 RC-000714-2017
Glazing Area 15%
Climate Zone: 6 (7635 HDD) Cerrone Builders
Permit Date: 42 Alessia Drive, Lot 8
Permit Number: SFD w/FP 1986 s.f., Garage 420 s.f.
Construction Site: Owner/Agent: Designer/Contractor:
Wm Lot 8 Cerrone Builders Inc VISION Engineering LLC
Queensbury, NY 12804 206 Glen Street
Suite 56
Glens Falls, NY 12801
Compliance: 0.0%Better Than Code Maximum 1 356 Your 1 356
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area cavity Cont.
Assembly or R-Vallue R-Vallue LI-Factor UA
Perimeter
Wall 1: Wood Frame, 16" o.c. 1,445 21.0 0.0 0.057 69
Window 1: Vinyl Frame:Double Pane with Low-E 150 0.290 44
Door 1: Solid 20 0.200 4
Door 2: Solid 18 0.140 3
Door 3: Glass 40 0.290 12
Wall 2: Wood Frame, 16" o.c. 944 21.0 0.0 0.057 46
Window 2: Vinyl Frame:Double Pane with Low-E 135 0.290 39
Wall 3: Wood Frame, 16" o.c. 384 21.0 0.0 0.057 17
Window 4: Vinyl/Fiberglass Frame:Double Pane with Low-E 45 0.290 13
Door 4: Glass 40 0.290 12
Ceiling 1: Raised or Energy Truss 1,147 38.0 0.0 0.025 29
Basement Wall 1: Solid Concrete or Masonry 882 0.0 19.0 0.038 33
Wall height: 7.8'
Depth below grade: 7.0'
Insulation depth: 7.8'
Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 4 0.350 1
Floor 1: All-Wood joist/Truss:Over Outside Air 26 30.0 0.0 0.033 1
Floor 2: Slab-On-Grade:Unheated 48 10.0 0.684 33
Insulation depth: 4.0'
Project Title: Cerrone Builders Inc Report date: 11/03/17
Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1286 - DES - Page 1 of 10
CER West Mtn Lot 8\1286 Rescheck.rck
AL
Software Version 4.6.4
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section lsrifici Field Verified '
# Pre-Inspection/plan Revlew fa(a� Valueomplies? � Comrr�ents/A§surra t6ans;'
tx A �
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal -]Not Observable
envelope represented on [—]Not Applicable
'construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ; ❑Does Not
403.7 energy code compliance for Ali�
[PR3)1 lighting and mechanical systems ❑Not Observable
Systems serving multiple 2IM11 ❑Not Applicable
dwelling units must demonstrate "
compliance with the IECC
,Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 "sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
I.PR212 on loads calculated per ACCA Cooling: Cooling:
Manual) or other methods ❑Not Observable '
Btu/hr
Btu/hr
approved by the code official, ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) Medium Impact(Tier 2) 3Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/03/17
Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1286 - DES - Page 3 of 10
CER West Mtn Lot 8\1286 Rescheck.rck
Sect
€ori 3 Plans Verified i Field Verified
Framing f Rough-in Inspection, Valeo alio Complies? Cors me fis/Assum,
K ID
402.1.1, Door U-factor. U- U ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1
-]Not Observable
❑Not Applicable ;
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies I See the Envelope Assemblies
402.3.1, average). ❑Does Not ;table for values.
402.3.3,
402.3.6, ❑Not Observable _.
402.5 ❑Not Applicable
[FR2]1
>
303.1.3 U-factors of fenestration products []Complies
[FR4]1 are determined in accordance 4 ❑Does Not
with the NFRC test 40 procedure or
taken from the default table. ❑Not Observable
n 'e ❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
" �;
[FR23]1 installed per manufacturer's �. kl v []Does Not
instructions.
4f
�`'❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting s: : ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable
or has infiltration rates per NFRC
'400 that do not exceed code ❑Not Applicable
limits.
�-- .._
IC-rated recessed lighting fixtures ❑Cimplies
j sealed at housing/interior finish []Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. F, []Not Observable
:❑Not Applicable
403.2.1 Supply and return ducts in attics []Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
' R-6 where < 3 inches. Supply and s ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
_ for< 3 inches in diameter.
z
403! 3.5 Building cavities are not used as4 ❑Complies
(FR-1513 =ducts or plenums. �e ❑Does Not
❑Not Observable
❑Not Applicable
4031.4 HVAC piping conveying fluids R R ❑Complies
[FR17]2 above 105 QF or chilled fluids ❑Does Not
below 55 QF are insulated to
>_R--]Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC = =❑Complies
[FR24]1 piping. � ❑Does Not r
E ,,❑Not Observable ;
❑Not Applicable
4' S Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. :❑Does Not
❑Not Observable ;
❑Not Applicable
403.6 Automatic or gravity dampers are [ Complies
[FRI9]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
11 High Impact(Tier 1) Medium Impact(Tier 2) 3 "Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/03/17
Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1286 - DES- Page 5 of 10
CER West Mtn Lot 8\1286 Rescheck.rck
Section Ruts Verified Field Verified
i Insulation inspection
Valu (uComplies? Comments/Assumptions
CxRe .IDt
303.1 =All installed insulation is labeled ❑Complies
CIN1312 "or the installed R-values ❑Does Not
provided.
- ` ❑Not Observable
E ❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies ;See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not :table for values.
[IN1)1 ❑ Steel ❑ Steel ❑Not Observable
!❑Not Applicable
J
303.2, Floor insulation installed per a ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
underside of the subfloor, or floor -.",,,, ❑Not Observable
framing cavity insulation is in :'❑Not Applicable
contact with the top side of "
sheathing, or continuous
insulation is installed on the1>3
underside of floor framing and
extends from the bottom to the ,
top of all perimeter floor framing .. ,
402.1.1, :Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
,402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3)1 ;exterior,the exterior insulation
requirement applies (FR10). ❑ Steel F1 Steel ❑Not Applicable
414 303.2 Wall insulation is installed per-mmmm []Complies
[IN4]1 manufacturer's instructions. ❑Does Not
Lt /
❑Not Observable
3 ., ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) ' Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/03/17
Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1286 - DES - Page 7 of 10
CER West Mtn Lot 8\1286 Rescheck.rck
Section ---—
_ - _ _ m
Flans Verified FieldVerified
# Fina 6Fectian Fr�vrs�ons Stelae Vtc�e Cp
orlies� Comments/Assumptions
l
Re .1D [
4016,1 All mechanical ventilation system ❑Complies
[1712512 'fans not part of tested and listed ❑Does Not 3
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
❑Not Applicable
4012 Hot water boilers supplying heat ❑Complies
through one-or two-pipe heating ❑Does Not
O systems have outdoor setback y i
❑Not Observable `.
control to lower boiler water ,
temperature based on outdoor � r y ❑Not Applicable
%r.v ,Evn7 c ia�av 'ry '
y-, }
temperature. .,
403.5.1.1 'Heatedwater circulation systems ¢� f❑Complies
[F12812 have a circulation pump.The r ❑Does Not
system return pipe is a dedicated [ "❑Not Observable
return pipe or a cold water supply' ,
pipe. Gravity and thermos- � ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls °
` automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
;r no demand for hot water exists.
:6i1 2; Electric heat trace systems a E ❑Complies
tFI7comply with IEEE 515.1 or UL ❑Does Not
4heat
515.Controls automaticallyadjust the energy input to the ❑Not Observable
❑Not Applicable tracing to maintain the f
desired water temperature in the
piping. _
4 Water distribution systems that ❑Complies ®--
[F130[ have recirculation pumps that r ❑Does Not
pump water from a heated water ' `
' ❑Not Observable
supply pipe back to the heated
water source through a cold s � � }❑Not Applicable
water supply pipe have a '
demand recirculation water s r
system. Pumps have controls
, ,,that manage operation of the
pump and limit the temperature `u y
of the water entering the cold
water piping to 1044F.
4403.5.4 Drain water heat recovery units omplies
[F13112 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[FI611 fixtures or 75%of permanent '❑Does Not
fixtures have high efficacy lamps
Does not apply to low-voltage ❑Not Observable
1. lighting. ❑Not Applicable
404,1,1 Fuel gas lighting systems have ❑Complies
[F1231� no continuous pilot light. ~• ❑Does Not
❑Not Observable
❑Not Applicable
11 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Cerrone Builders Inc Report date: 11/03/17
Data filename: C:\Users\DWR Desktop\Dropbox\VISION Engineering, LLC\Active Projects VE\1286 - DES - Page 9 of 10
CER West Mtn Lot 8\1286 Rescheck.rck
1015 IECC Energy
Efficiency Certificate
,
Above-Grade Wall 21.00
Below-Grade Wall 19.00
Floor 10.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass& ®,. ,
Window 0.29
Door 0.29
Heating System:
Cooling System:
Water Heater•
Name: Date:
Comments