Loading...
2007-599 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20070599 Date Issued: Thursday, September 04, 2014 This is to certify that work requested to be done as shown by Permit Number P20070599 has been completed. Location: 21 BROOKSHIRE Trce Tax Map Number: 523400-308-018-0001-004-000-0000 Owner: TIMOTHY & NANCY GRACE Applicant: TIMOTHY& NANCY GRACE This structure may be occupied as a: Garage Attached By Order of Town Board Residential Addition TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,Variance, or ' other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. ij TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070599 Application Number. A20070599 Tax Map No: 523400-308-018-0001-004-000-0000 Permission is hereby granted to: TIMOTHY&NANCY GRACE For property located at: 21 BROOKSHIRE Trce in the Town of Queensbury,to construct or place at the above location in ac ce wi lication together with plot plans and o r' o tion hereto filed and approved and in pliance with the S Uniform Building Codes and the Zoning Ordinance. T e o ction Value Owner Addre TIMOTHY &N CY GRACE 21 BROOKSH E Trce Gara Attached $15,000.00 QUEENSBU ,NY 12 01 Reside tial Addition a alue $15,000.00 Contractor or Builder's ame Addres Electrical Inspection Agency TIMOTHY GRACE 21 BROOKSHIRE T C QUEENSBURY, NY 28 4 Plans &Specifications 2007-599 Residential Addition and Alteration $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday, October 15,2009 (If a longer period is required,an application for an extension must be made to the code Enforcement officer of the Town of Queensbury before the expiration date.) Dated at th own Qu sbS r, y, October 15,2007 SIGNED BY ®°� for the Town of Queensbury. Director of Building&Code Enforcement Da WINDOW SCHEDULE LSEPa zooT Job Site/Address: 2-t t't �'C ?1 - Date: TOWN OF QUEENSB�.: Owner: Application No. ING& CODES Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening Glass/Vis Egress/Cie Opening Opening or Instructions Letter on Name Numbe g Height Ible Vent ar Width in Height Plan Call Width Light Opening Inches in Inches Size _ L3 "A 44 tip.Sa 5.as .q 1 ''�i 22'J2- Example Entry A Andersen Narroline 3062 3' 2 6'5 '/z 15.30 8.36 6.01 34 2416/35" Tempered Double 1/3" Ad11/16 Glazing Hun C:\Documents and Settings\Sue%ocal Settingffemp\Window Schedule.doc lo Job Site Address: 'l l IW4ZV 54 tV-Ir,- �'1JkG Date:.. le Owner: ��Z1�C1� Application No. File N SEP 2 0 2007 Building Permit Calculation Sheet Towia a c __,, = Natural Light, Ventilation & Emergency Egress Requireme BUILDING & CoL; ' Habitable Area of Req. Light Actual Req.Vent .Actual Nff Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vent Opening for in Area Square Area Square Egress Square Footage Footage Feet L:\,SueHemingway\Building.Petmit.FORMSWat.Light.V entil.Calculation.Sheet.doe TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 FILE Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070599 Application Number: A20070599 Tax Map No: 523400-308-018-0001-004-000-0000 Permission is hereby granted to: TIMOTHY&NANCY GRACE For property located at: 21 BROOKSHIRE Trce in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: TIMOTHY& NANCY GRACE Garage Attached $15,000.00 21 BROOKSHIRE Trce QUEENSBURY, NY 12804 Residential Addition Total Value $15,000.00 Contractor or Builder's Name / Address Electrical Inspection Agency TIMOTHY GRACE 21 BROOKSHIRE TRCE QUEENSBURY, NY 12804 Plans&Specifications 2007-599 Residential Addition and Alteration $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, October 15, 2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of ens ctober 15, 2007 SIGNED BY fG! for the Town of Queensbury. Director of Building&Code Enforcement Permit No. " Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid `� ! 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@aueensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the,,application form. Applicant/Builder Owner: nn Address: ] Address: n t ram, u Home Phone: Home Ph Email Address: D Email Ad r - Cell Phone: al Z S ? - �3 Cell Phon Y FAX Phone: FAX Phon TOWN ES Person responsible for supervision of work with respect to building and codes compliance: Name: SAJ•24 is Address: Phone Location of proposed construction: Lot No. 4 Legal Address: '� Q�tl�u1 �1AG Tax Map Number: 3a, I Subdivision Name: Estimated Cost of Construction: 006 Proposed construction is for: Residential Use `Commercial Use Name of Business: If proposed construction is an addition,what will use of new addition be? New Addition Alteration Proposed Construction 10 Floor 2nd floor Other Tota Proposed structure (Occupancy Type) Sq.Ft. sq.ff. Sq. Ft. Square feet Height . ) Ft.&.In. Single-Family Dwelling Two-Famity Dwelling Townhouse Multifamily Dwelling Number of Units* � Office Mercantile Manufacturing Other: Attached Garage 1, 2, 3 Type of Heating System: Electri Oil Gas, Wood(Forced Hot Air, Baseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes ,No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that Uwe shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all n c nstruction. Date: Applicant/Builder Signature The application of dated is hereby approved and permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set forth above. Date: Authorized Signature: L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 S -ra--'Lk s Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: yT arn/orn Depart: am/pm Date Inspection request received: Inspector's Initials: L 1 NAME: Q c Gr a PERMIT LOCATION: ! r �( rQ DATE: vy TYPE OF STRUCTURE: Q q r c G? Comments: Y No NIA 4" BuildingNumber Address visible from road �Y P 16 _ 1 5 -d 9 Chimney Height/"B"VentUrect Vent Location Ir Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Co ete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above graft Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sib plate Gas Valve shut-off exposed/regulator 18 inches above grade a 4 � Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safe lain /Window in stairwells safetyglazing /^Si�G'P`/'c Interior Smoke Detectors/Carbon Monoxide Detectors 0 Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: - M� Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq.ft-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures / cdv Foundation insulation to floor/Sticker on Panels Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 .ft. Emergency Tess below grade Gas Furnace shut-off within 30 feet or within fine of site Oil Furnace shut-off at entrance to fumace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L•\Building&Codes Forms\Building&Codesllnspection FormsWesidential Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12=10,Revised 04/13/11 &—a '- / pM ` Queensbury Building & Code Enforcement - Residential Final Inspection 1 Office No. (518) 761-8256 Arrive: ;`tip arn/n Depart: am/pm Date Inspection request received: Insp ectors Initials: NAME: ' PERMIT#: 0�� Sw LOCATION: ak Sk DATE: TYPE OF STRUCTURE: Comments- 4" Building Number Address visible from road Yes No NIA Chimney Height/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety Pain Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.11A 50 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed rl /Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to fumace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"G um Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles �� Flex Gas Pi Bonding As Built Sepfic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certificatio uired 1 -71 _Okay to issue C/ C/offlremporary/Permanent L:\Building&Codes Forms\Building&Codes\lnspec bon Forns\Reskhmftl Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 Queensbury Building & Code Enforcement - Residential Final Inspection ' Office No. (518) 761-8256 Arrive: .31-1 amITM Depart: am/pm Date Inspection request received: 3 Inspector's Initials: � — NAME: C 1 � PERMIT#: LOCATION: r ,; i i_t_ �- DATE: TYPE OF STRUCTURE: Comments: 4" Building Number Address visible from road Yes No NIA Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 kx*m above grade Guard at stairwell at 34 Inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterfight SAAy glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.ft.-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs dosed rise>4 inches -Garage Floor Pitched Garage fi r /%hour fire door/door closer lc. Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Ui ht Bulbs 50% Final SurveyPlot Plan �_ Coo e- �� �` ��r Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker / {�� Site Plan /Variance required ' Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Cerman L:18uilding&Codes FormslBuilding&Codes\Inspection ForrnslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12122/10,Revised 04/13/11 Queensbury Building & Code Enf ment - Residential Fi v pecti Office No. (518) 761-8256 Z44: am/pm epart: 37u am/pm Date Inspection request received: lns pector's Initials: NAME: J PERMIT#: a LOCATION: O DATE: FL TYPE OF STRUCTURE: Comments: 4" Building Number Address visible from road Yes No NIA Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 i xim above grade Guard at stairwell at 34 inches or more Guard at deck,pordm 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Hand' Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq.ft-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed property/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within One of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan or / Arc Fault Breaker Habitable Spaces/Tamper Proof Receptaclesl Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C!C or C 10 Temporary/Permanent L:1Building&Codes FormslBuilding&Codes\Inspection ForrnsWesidenbal Final Inspection Form revised_100405.doc;Revised January 7,2008;Revised 6/26=-,Revised 12/22/10,Revised 04/13/11 Queensbury Building & Code Enfor n - %idential Final Inspection 3 j Do ,_ Office No. (518)761-8256j a 3 fZ Arrive: 1 am/pm Depart: am/pm Date Inspection request received: inspector's Initials: tr NAME: c c<; - PERMIT#: 07 LOCATION: 9C Uy Ski CLC' AC DATE: TYPE OF STRUCTURE: Comments- Yes No I NIA 4" Building Number Address visible from road Chimney Height/W Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 bx*m above grade Guard at stairwell at 34 inches or more Guam at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Ralflnp 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterti t Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 s .ft:150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency ress below arade Gas Furnace shut-off within 30 feet or within fine of site Oil Furnace shut-off at entrance to furnace area Fumaoe/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum W G sum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer i/ Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 1 Tem ra /Permanent LABuilding&Codes Forms\Building&Codes\inspection FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12122/10,Revised 04/13/11 ,. Queensbury Building. Code Enforcement - Residential Final inspection C3Yf'ice No. (518)761-8256 Arrive: am/pm Depart��'Dam/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT* LOCATION: DATE: TYPE OF STRUCTURE:/' (� Comments• Y 4" Build N NIA Number Address visible from road �� 1®^ /�/`�� Chim Hei ht/°B'Vent/Direct Vent Location / L,J Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks more than 30 indres above grade Guard at stairwell at 34 inches or more Guard at deck es 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Rallfts 34 inches to 38 inches Deck Bra /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate Gas Valve shut-off i Mqulator 18 inches above grade Interior privacy/trim/doors I main entrance 36 inches Bathroom/Kitchen watertight Safe /Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: ,� Attic access 30 inches x 22 inches x 30 inches(height)in accessible area 1 Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-1 50 sq.ft.vents G YQ� Bathroom Fans,if no window -' Plumbina fbdures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emer gency egress below grade t Gas Furnace shut-off within 30 feet or within One of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves Installed/Heat Trap/Water Temp 110 Endosed Stairs Sheetrock underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door.closer Duct work Seated property Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Oka to issue C/C or C 10 Temporary/Permanent L:1Building&Codes Forms\Building&CodesVnspection FonnsWesidential Final Inspection Form revised—100405.doc;Revised January 7,2008;Revised 6/26/08 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/W Depart: am/pm Date Inspection request received: Inspector's Initials: NAME: �.� ,�`z c PERMIT#: 7 LOCATION: /`t .,.c .t DATE: TYPE OF STRUCTURE: Comments: 4" Building Number Address visible from road Yes No NIA Chimney Height/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Intedor/Exterior Rallinp 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch dearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterWd Saftety glazin /Window in stairwells safety lain Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access,l sq.ft:150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Fumace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles f Flex Gas Pipe Bonding I As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent ' L:1Budding&Codes FormslBuilding&Codes\Inspection Fomhs%Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12=10,Revised 04/13/11 Queensbury Building & Code Enforcement - ResidentialjF* I spection Office No. (518)761-8256 Arrive: v � rt: am/pm Date Inspection request received: Inspector's Initials: F NAME: PE .�.3� . LOCATION: �_ UCT L� TYPE OF STRURE: C D e Comments- 4" BuildingY No NIA Number Address visible from road a� ChimneyHeight/"B"Vent/Direct Vent Location 1 m 10 L3 E (� T'G Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers O Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more RL\tA 'jT -T -�Ff\oD uc7 Handrail Termination at Nevwell Post or Wall _ Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant &LjD6V1C) 00T . Ph O e Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate C.>l)R Gas Valve shut-off exposed J regulator 18 inches above gradeLLt=j\�\ Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight ���� Safety glazing/Window in stairwells safety lain Interior Smoke Detectors/Carbon Monoxide Detectors ZU 1 Every level: Every Bedroom: Outside every bedroom area: nter Connected: Battery backup: TO 1�.6-TAL.L..- 9,3U \,4b0LRT)P Attic access 30 inches x 22 inches x 30 inches(height)in accessible area V1 ��R� �`LACrawl Spaces 18 inch x 24 inch access 1 .ft:150 .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel 1 R� -5 V— R qu \ \C, Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency ress below grade QC\p �p o Gas Furnace shut-off within 30 feet or within fine of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler ZZ' `` C� 6,4) Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum -TC) U VDF1 pJo4—A Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing I%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% C) Final Survey Plot Plan p ww— Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bondi_. -� `J � `� As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required p lood Plain Certification,if required 6— _Okay to issue C/C or C 10 Temporary J Permanent L bi TK:—\ MC F L:\Building&Codes Forms\Building&Codes\Inspection Fonns\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 ���� Queensbury Building & Code Enforcement - Residential Foal Inspection Office No. (518)761-8256 Arrive: a m part: 1�M a pm Date Inspection request received: Inspector's Initials: NAME: P MIT#: r)- --s- LOCATION. 1 .�r�:n h'ir = ti DATE: TYPE OF STRUCTURE: (44acaQ c' Comments• Yes No NIA 4" Building Number Address visible from road Chimney Height/'13"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant c Grade away from foundation 6 inches with 10 feet 6 inch clearance to six plate ���\ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety lain Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 s .ft:150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed propedy/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency a ress below grade Gas Furnace shut-off within 30 feet or within fine of site Oil Fumace shut-off at entrance to fumace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodc Underside minimum IN Gypsum Basement stairs dosed rise>4 inches Gara a Floor Pitched Garage fire /%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final SurveV Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required _Okay to issue C/C or C 10 Temporary/Permanent L:\Buxding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised-100405.doc;Revised January 7,2008,Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 -7 `I' (k S Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518) 761-8256 Arrive: '% a Wee"-- an Q Date Inspection request received: Inspector's Initials: J 1 NAME: C L, (-r-I-CP CC P T �C� LOCATION: L(z TYPE OF STRUCTURE: 1P .M--,(7 V-o Comments: Yes No NIA 4" Building _Number Address visible from road `1( p b - aca Chimne Height/"B"Vent/Direct Vent Location /� r > Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platfom at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 kx*m above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen materfight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area L�G _ Crawl Spaces 18 inch x 24 inch access, 1 .ft:150 .ft.vents CL Bathroom Fans if no windowTDA� Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stoppingfinished basement 1,000 .ft. Emergency egress below grade Gas Fumace shut-off within 30 feet or within fine of site Oil Fumace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum C-iE t�� Basement stairs dosed rise>4 inches IIZ—3t, Gara a Floor Pitched _ Garage fireproofing/%hour fire door/door closer �f Gas Logs in Sealed or Glass Enclosure L ��-�G F Final Electrical;Energy Saving Light Bulbs 60% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built SWic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent LABuHding&Codes FormslBuilding&Codesllnspection ForrnsWesidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12/22/10,Revised 04/13/11 Queensbury Buildind & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: ! v am/pm Date Inspection request received: Inspector's Initials: NAME: v����►�,� PERMIT#: 2 LOCATION: \ DATE: TYPE OF STRUCTURE: Comments- 4° Buildby Number Address visits from road Chimney Hei ht/'B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers 1 c Guards at stairs deckspatios more than 30 inches above grade �� u Guard at stain"li at 34 inches or more Guard at deck aches 36 inches or more Handrail Termination at Newell Post or Wall Intedor/Eaderior Railings 34 inches to 38 inches �`— Dedc Bracing/Handicapped Ramp Compliant Grade 9%"y from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off gN22pEW/regukftr 18 inches above grade interior /trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety /Window in stairwells safe Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 .ft:150 sq.ft.vents BaMroorn Fans if no window Plumbi fixtures Foundation insulation/Insulation Certification Floor truss draft stopping finished basement 1,000 .ft. Emerpency 29Lws below greds Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumaae/Hot Water Heater operating Low water shut-off boiler Relief Valve s installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gynm Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed Gas Loos In Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. In on Sticker Site Plan /Variance required Flood Plain Certification if required Okay to issue C/C or C 10 1 Temporary/Permanent LABuilding&Codes FormslBuilding&Codes\Inspection FormslReWdential Final Inspection Fo"n_nwIsed_100405.doc;Revised January 7,2008;Revised 8/26/08 Queensbury Building Code Enforcement - Residential Final inspection ice No. (518) 761-8256 Arrive: am/pm Departam/pm Date Inspection request received: Inspector's Initials: AA NAME: PERMIT#: LOCATION: DATE: " ' 6 TYPE OF STRUCTURE Comments• N N! 4" Building Number Address visible from road J —`5 Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 Inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deckporches 36 Inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off Tposed/regulator 18 inches above grade Interior priM I trim/doors/main entrance 36 inches b Bathroom/Kitchen watertight Safety glazing/Window in stairwells Mfety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area:Inter Connected: BatteryA backup:_ �I v � Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 .ft..-1 50 sq.ft.vents ((( Bathroom Fans,if no window J Plumbina fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A'Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garalle fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic S stem/Sewer Dept. Inspection Sticker Site Plan I Variance required Flood Plain Certification,if required Okay to issue C I C or C 10 Temporary/Permanent LABuilding&Codes Form"uilding&CodesUnspection FormslResidential Final Inspection Forrn_revise0_100405.doc;Revised January 7,2008;Revised 8/26/08 ) -- �s (t-'-r I Aal Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Dep• pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:/ NAME: I PERMIT#: LOCATION: `r INSPECT ON: TYPE OF STRUCTURE: Comments L Y N N/A } vex. Footings x 4/ePiers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width es a ve footing 1 fo wet-areas under slab 4BIackfillApprov 1 Plumbing er Slab P /Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report ------ Office No.(518)761-8256 Date Inspection request received: i U Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: n. � -- PERMIT#: 400 LOCATION: INSPECT ON: A TYPE O TRUCTURE: � U �9 a Comments Y N N/A tin — Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump v Footing Drain Stone: 12 inch width ' 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval '--.W" A Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM a Permit# ✓ Q Permit Date REScheck Software Version 3.7.3 Compliance Cedific7HIRET, E C E-- Project Title: GRACE- 21 BROOKKSHIRE TRACE SEP 2 0 2007 Report Date:09/11/07 Data filename:C:\Program Files\REScheck\REScheck\TIM GRACE-GRACE-21 BROO $AEW NSBURUILDING& CODES Energy Code: New York State Energy Conservation Construction Code Location: Saratoga County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 14% Heating Degree Days: 72" Construction Site: Owner/Agent: Designer/Contractor: 21 BROOKSHIRE TRACE TIM GRACE DANIEL WILLIAMS QUEENSBURY,NY 12804 21 BROOKSHIRE WILLIAMS&WILLIAMS DESIGNERS QUEENSBURY,NY 12804 INC. 509 GLEN STREET GLENS FALLS,NY 12801 (518)798-4687 . . . ..- Ceiling 1:Cathedral Ceiling(no attic): 180 38.0 0.0 5 Wall 1:Wood Frame, 16"o.c.: 268 19.0 0.0 14 Window 1:Wood Frame:Double Pane with Low-E: 38 0.330 13 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space: 174 38.0 0.0 5 Boiler 1:Gas-Fired Steam:87 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations miffed 'th this permit application.The proposed systems have been designed to meet the New York State Energy Conservation ktructi C e requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that h to st i r owledge,belief,and professional judg ent,such plans or specifications are in compliance with this Code. i " Company Name Date Project Notes: WILLIAMS&WILLIAMS DESIGNERS IS ONLY RESPONSIBLE FOR THE RES-CHECK COMPLIANCE CERTIFICATE. GRACE-21 BROOKKSHIRE TRACE Page 1 of 4 r REScheck Software Version 3.7.3 Inspection Checklist Date:09/11/07 Ceilings: ❑ Ceiling 1:Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.330 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-38.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Boiler 1:Gas-Fired Steam:87 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-8. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-4. ❑ Supply ducts in unconditioned spaces must be insulated to R-8. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), GRACE-21 BROOKKSHIRE TRACE Page 2 of 4 mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. GRACE-21 BROOKKSHIRE TRACE Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2.Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low PressurelTemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) GRACE-21 BROOKKSHIRE TRACE Page 4 of 4