A190505 - Lighting COMcheck-Web_compliance_report_20200505_114745_115COMcheck Software Version COMcheckWeb
Interior Lighting Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Construction Site:
160 Aviation Road
Queensbury, New York 12804
Owner/Agent:
Tim Bartlett
United Cerebral Palsy Association of
the Tri-Counties, Inc.
22 Corporate Woods Blvd 5th Floor
Albany, New York 12211
518-703-0549
t_bartlett@cfdsny.org
Designer/Contractor:
Fusion Systems Engineering, DPC
634 Plank Road, Suite 203B
Clifton Park, New York 12065
5186210533
Project Information
Energy Code:
New Respite Care Facility 160 Aviation Road
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Additional Efficiency Package(s)
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
ft2)
C
Allowed
Watts / ft2
D
Allowed
Watts
1-First Floor (Multifamily)4123 0.46 1892
2-Basement (Multifamily)4123 0.46 1892
3785TotalAllowedWatts =
Proposed Interior Lighting Power
E
C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
of
Fixture
1-First Floor (Multifamily)
LED: Fixture A: Other:1 53 17 922
LED: Fixture D: Other:1 25 10 250
2-Basement (Multifamily)
LED: Fixture C: Other:1 20 9 172
1344TotalProposedWatts =
Interior Lighting Compliance
Statement
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES: Design 64% better than code
Project Title:
Data filename:
New Respite Care Facility 160 Aviation Road 05/05/20Reportdate:
51ofPage
COMcheck Software Version COMcheckWeb
Exterior Lighting Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Construction Site:
160 Aviation Road
Queensbury, New York 12804
Owner/Agent:
Tim Bartlett
United Cerebral Palsy Association of
the Tri-Counties, Inc.
22 Corporate Woods Blvd 5th Floor
Albany, New York 12211
518-703-0549
t_bartlett@cfdsny.org
Designer/Contractor:
Fusion Systems Engineering, DPC
634 Plank Road, Suite 203B
Clifton Park, New York 12065
5186210533
Project Information
Energy Code:
New Respite Care Facility 160 Aviation Road
2 (Residentially zoned area)Exterior Lighting Zone
Allowed Exterior Lighting Power
A
Area/Surface Category
B
Quantity
C
Allowed
Watts /
D
Tradable
Wattage
E
Allowed Watts
B X C)
Front Entrance (Entry canopy)208 ft2 0.25 Yes 52
Rear Entrance (Illuminated area of facade wall or surface)288 ft2 0.1 No 29
Total Tradable Watts (a) =
Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
52
81
600
a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable
areas/surfaces.
Proposed Exterior Lighting Power
E
C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
of
Fixture
Front Entrance (Entry canopy, 208 ft2): Tradable Wattage
LED: Fixture A: Other:1 4 18 70
Rear Entrance (Illuminated area of facade wall or surface, 288 ft2): Non-tradable Wattage
LED: Fixture B: Other:1 6 8 48
70TotalTradableProposedWatts =
Exterior Lighting Compliance
Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Exterior Lighting PASSES: Design 89% better than code
Project Title:
Data filename:
New Respite Care Facility 160 Aviation Road 05/05/20Reportdate:
52ofPage
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version COMcheckWeb
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
C103.2
PR8]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the exterior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
New Respite Care Facility 160 Aviation Road 05/05/20Reportdate:
53ofPage
Section
Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.1
EL15]1
Lighting controls installed to uniformly
reduce the lighting load by at least
50%.
Complies
Does Not
Not Observable
Not Applicable
C405.2.1
EL18]1
Occupancy sensors installed in
required spaces.
Complies
Does Not
Not Observable
Not Applicable
C405.2.1,
C405.2.2.
3
EL23]2
Independent lighting controls installed
per approved lighting plans and all
manual controls readily accessible and
visible to occupants.
Complies
Does Not
Not Observable
Not Applicable
C405.2.2.
1
EL22]2
Automatic controls to shut off all
building lighting installed in all
buildings.
Complies
Does Not
Not Observable
Not Applicable
C405.2.3
EL16]2
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting.
Complies
Does Not
Not Observable
Not Applicable
C405.2.3,
C405.2.3.
1,
C405.2.3.
2
EL20]1
Primary sidelighted areas are
equipped with required lighting
controls.
Complies
Does Not
Not Observable
Not Applicable
C405.2.3,
C405.2.3.
1,
C405.2.3.
3
EL21]1
Enclosed spaces with daylight area
under skylights and rooftop monitors
are equipped with required lighting
controls.
Complies
Does Not
Not Observable
Not Applicable
C405.2.4
EL4]1
Separate lighting control devices for
specific uses installed per approved
lighting plans.
Complies
Does Not
Not Observable
Not Applicable
C405.2.4
EL8]1
Additional interior lighting power
allowed for special functions per the
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
C405.2.5
EL25]null
Automatic lighting controls for exterior
lighting installed. Controls will be
daylight controlled, set based on
business operation time-of-day, or
reduce connected lighting > 30%.
Complies
Does Not
Not Observable
Not Applicable
C405.3
EL6]1
Exit signs do not exceed 5 watts per
face.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
New Respite Care Facility 160 Aviation Road 05/05/20Reportdate:
54ofPage
Section
Req.ID
Final Inspection Complies?Comments/Assumptions
C303.3,
C408.2.5.
2
FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
C405.4.1
FI18]1
Interior installed lamp and fixture
lighting power is consistent with what
is shown on the approved lighting
plans, demonstrating proposed watts
are less than or equal to allowed
watts.
Complies
Does Not
Not Observable
Not Applicable
See the Interior Lighting fixture schedule for values.
C405.5.1
FI19]1
Exterior lighting power is consistent
with what is shown on the approved
lighting plans, demonstrating
proposed watts are less than or equal
to allowed watts.
Complies
Does Not
Not Observable
Not Applicable
See the Exterior Lighting fixture schedule for values.
C408.2.5.
1
FI16]3
Furnished as-built drawings for
electric power systems within 90 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
C408.3
FI33]1
Lighting systems have been tested to
ensure proper calibration, adjustment,
programming, and operation.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
New Respite Care Facility 160 Aviation Road 05/05/20Reportdate:
55ofPage