Signed Inspection Report (05-11-2020).pdfINSPECTION WORKSHEET (RESFINAL-002071-2020)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-000678-2016 Case Module:Permit
Inspection Date:Mon May 11, 2020 Inspection Status:Failed
Inspector:Charles Dyer Inspection Type:Residential Final Inspection
Job Address:Parcel Number:34 GUNN LN
Queensbury, NY, 12804
227.17-1-17
Contact Type Company Name Name
Primary Owner Wheeler, Jacqueline
Contractor McAvinney Builders LLC
Granted Permission McAvinney Builders LLC
Applicant Wheeler, Jacqueline
Contractor Ellsworth & Son Excavating
Checklist Item Status
General Comments Failed
For temp CO
Conditions - site plan review, septic asbuilt and final electric. Completion of siding, final survey
10/31/18 spoke with D Macavinny contractor will be in to renew temp CO
Permit still on hold status, the temp CO has expired, please contact building department to renew. 5/11/20
4 inch Building Number Address visible from road Failed
Chimney Height / B Vent / Direct Vent Location Passed
Chimney Rain Cap Installed Passed
May 11, 2020 Page (1)
INSPECTION WORKSHEET (RESFINAL-002071-2020)
Checklist Item Status
Fresh Air Intake Passed
3" Plumbing Vent through roof minimum 18 inch Passed
Outside Spigots have Air Gap Passed
Roof Complete / Exterior Finish Complete Failed
Platform at all exterior doors Failed
Handrail 4 or more risers Passed
Guard at stairwell at 34" or more Passed
Handrail Termination at Newell Post or Wall Passed
Interior/Exterior Railings 34 to 38 Passed
Grade away from foundation: 6" down, 10' out Failed
Winter conditions
6" clearance to sill plate Passed
Gas Shut-off Exposed & Regulator (18) Above Grade Failed
May 11, 2020 Page (2)
INSPECTION WORKSHEET (RESFINAL-002071-2020)
Checklist Item Status
Propane
Interior privacy/trim/doors/main entrance 36 Passed
Bathroom / Kitchen Watertight Passed
Smoke Detectors: Carbon Monoxide Passed
CO in Bedrooms w/Gas Passed
Smoke Detectors 3' from Kitchens & Baths R314 Passed
Every level, Every bedroom Passed
Outside every bedroom area Passed
Inter Connected Passed
Battery backup: _____Passed
Attic Access 22 x 30 minimum Passed
Attic Access Gasketed Passed
May 11, 2020 Page (3)
INSPECTION WORKSHEET (RESFINAL-002071-2020)
Checklist Item Status
Crawl Space Access 18 x 24 Passed
Bathroom Fans, if no window Passed
Plumbing fixtures Passed
Backflow Preventors where required Passed
Foundation insulation to floor Passed
ERROR - Setup Data Not Loaded!!!Passed
Duct work sealed properly Passed
Blower Door Test Certification Failed
N/A home was air sealed
HRV or ERV Installed per Bedroom Requirements Failed
N/A
Furnace shut-off w/in 30 ft. or w/in line of site Passed
Propane Tank: Proper Setback from Prop Line/Struct Passed
Furnace/Hot Water Heater operating Passed
May 11, 2020 Page (4)
INSPECTION WORKSHEET (RESFINAL-002071-2020)
Checklist Item Status
Relief Valve ,Heat Trap/Water Temp 110 deg or less Passed
20 Minute Fire Door/Self-Closing Hardware Passed
Seals on Garage Doors, esp. Wood Passed
Basement stairs closed rise greater than 4 inches Failed
Garage Floor Pitched Passed
Gas Log In Sealed or Glass Enclosure Passed
Fin Elect; Energy Saving Light Bulbs 50 Percent Passed
Final Survey Plot Plan Failed
Arc Fault Breaker Habitable Spaces Passed
As Built Septic System Failed
Site Plan / Variance required Failed
May 11, 2020 Page (5)
INSPECTION WORKSHEET (RESFINAL-002071-2020)
Checklist Item Status
Flood Plain Certification, if required Failed
Truss ID Signage Installed at Electrical Meter Failed
OK to Issue Temporary C/O Passed
OK to Issue C/O Failed
May 11, 2020 Page (6)
Dyer, Charles