Loading...
Wedgewood Building 5_51 Wedgewood_air leakage resultsTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:Wedgewood Building 5 Address:Wedgewood Dr Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.325916 Longitude: -73.684380 Timestamp: 2020-04-22 11:38:55 Customer Information: Name:Schermerhorn Holdings Address:536 Bay Rd Queensbury, NY 12804 Measured Leakage:714.3 CFM50 Test ID:51 Wedgewood Dr Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:3.82 (+/- 14.0%)Effective Leakage Area: 17.3 in² Building Volume:11,223.0 ft ³Enclosure Surface Area: 1,247.0 ft² Flow Coefficient (C):15.8 (+/- 60.1%)Exponent (n): 0.975 (+/- 0.172) Correlation Coefficient:0.99543 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 62 °F Altitude: 455.0 ft Outdoor Temp: 34 °F Time Average Period: 10 seconds Test Date and Time:2020-04-22 11:39:07 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline 0.8 -60.0 -59.6 -60.3 -24.9 911.4 Ring A -48.0 -49.8 -50.5 -167.4 766.9 Ring B -35.0 -39.8 -40.5 -124.6 662.5 Ring B -23.0 -23.3 -24.1 -52.8 432.8 Ring B -10.0 -8.8 -9.6 -44.3 149.5 Ring C Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 3173 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.