Wedgewood Building 6_88 Wedgewood_air leakage resultsTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:Wedgewood Building 6 Address:Wedgewood Dr Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.325916 Longitude: -73.684380 Timestamp: 2020-04-22 11:38:55 Customer Information: Name:Schermerhorn Holdings Address:536 Bay Rd Queensbury, NY 12804 Measured Leakage:771.1 CFM50 Test ID:88 Wedgewood Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:4.57 (+/- 1.8%)Effective Leakage Area: 36.3 in² Building Volume:10,127.0 ft³Enclosure Surface Area: 1,066.0 ft² Flow Coefficient (C):47.8 (+/- 7.0%)Exponent (n): 0.711 (+/- 0.020) Correlation Coefficient:0.99988 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 60 °F Altitude: 455.0 ft Outdoor Temp: 54 °F Time Average Period: 10 seconds Test Date and Time:2020-05-01 11:47:57 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -0.5 -60.0 -59.6 -59.2 -219.4 877.0 Ring B -48.0 -49.7 -49.2 -169.9 772.7 Ring B -35.0 -36.1 -35.6 -108.6 618.9 Ring B -23.0 -24.2 -23.7 -61.6 467.3 Ring B -10.0 -8.5 -8.0 -88.0 212.6 Ring C Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.