Signed Inspection Report (05-19-2020).pdfINSPECTION WORKSHEET (RESFINAL-002248-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000678-2016 Case Module:Permit Inspection Date:Tue May 19, 2020 Inspection Status:Partial Pass Inspector:Dave Hatin Inspection Type:Residential Final Inspection Job Address:Parcel Number:34 GUNN LN Queensbury, NY, 12804 227.17-1-17 Contact Type Company Name Name Contractor McAvinney Builders LLC Applicant Wheeler, Jacqueline Primary Owner Wheeler, Jacqueline Granted Permission McAvinney Builders LLC Contractor Ellsworth & Son Excavating Checklist Item Status General Comments Failed For temp CO Conditions - site plan review, septic asbuilt and final electric. Completion of siding, final survey 10/31/18 spoke with D Macavinny contractor will be in to renew temp CO Permit still on hold status, the temp CO has expired, please contact building department to renew. 5/11/20 4 inch Building Number Address visible from road Failed Chimney Height / B Vent / Direct Vent Location Passed Chimney Rain Cap Installed Passed May 19, 2020 Page (1) INSPECTION WORKSHEET (RESFINAL-002248-2020) Checklist Item Status Fresh Air Intake Passed 3" Plumbing Vent through roof minimum 18 inch Passed Outside Spigots have Air Gap Passed Roof Complete / Exterior Finish Complete Failed Platform at all exterior doors Failed Handrail 4 or more risers Passed Guard at stairwell at 34" or more Passed Handrail Termination at Newell Post or Wall Passed Interior/Exterior Railings 34 to 38 Passed Grade away from foundation: 6" down, 10' out Failed Winter conditions 6" clearance to sill plate Passed Gas Shut-off Exposed & Regulator (18) Above Grade Failed May 19, 2020 Page (2) INSPECTION WORKSHEET (RESFINAL-002248-2020) Checklist Item Status Propane Interior privacy/trim/doors/main entrance 36 Passed Bathroom / Kitchen Watertight Passed Smoke Detectors: Carbon Monoxide Passed CO in Bedrooms w/Gas Passed Smoke Detectors 3' from Kitchens & Baths R314 Passed Every level, Every bedroom Passed Outside every bedroom area Passed Inter Connected Passed Battery backup: _____Passed Attic Access 22 x 30 minimum Passed Attic Access Gasketed Passed May 19, 2020 Page (3) INSPECTION WORKSHEET (RESFINAL-002248-2020) Checklist Item Status Crawl Space Access 18 x 24 Passed Bathroom Fans, if no window Passed Plumbing fixtures Passed Backflow Preventors where required Passed Foundation insulation to floor Passed ERROR - Setup Data Not Loaded!!!Passed Duct work sealed properly Passed Blower Door Test Certification Failed N/A home was air sealed HRV or ERV Installed per Bedroom Requirements Failed N/A Furnace shut-off w/in 30 ft. or w/in line of site Passed Propane Tank: Proper Setback from Prop Line/Struct Passed Furnace/Hot Water Heater operating Passed May 19, 2020 Page (4) INSPECTION WORKSHEET (RESFINAL-002248-2020) Checklist Item Status Relief Valve ,Heat Trap/Water Temp 110 deg or less Passed 20 Minute Fire Door/Self-Closing Hardware Passed Seals on Garage Doors, esp. Wood Passed Basement stairs closed rise greater than 4 inches Failed Garage Floor Pitched Passed Gas Log In Sealed or Glass Enclosure Passed Fin Elect; Energy Saving Light Bulbs 50 Percent Passed Final Survey Plot Plan Failed Arc Fault Breaker Habitable Spaces Passed As Built Septic System Failed Site Plan / Variance required Failed May 19, 2020 Page (5) INSPECTION WORKSHEET (RESFINAL-002248-2020) Checklist Item Status Flood Plain Certification, if required Failed Truss ID Signage Installed at Electrical Meter Failed OK to Issue Temporary C/O Passed OK to Issue C/O Failed May 19, 2020 Page (6) Hatin, Dave