Loading...
2007-621 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 4z Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20070621 Date Issued: Tuesday, April 22, 2008 This is to certify that work requested to be done as shown by Permit Number P20070621 has been completed. Location: 44 MALLORY Ave Tax Map Number. 523400-309-007-0002-026-000-0000 Owner. DAWN SWEET Applicant: DAWN SWEET This structure may be occupied as a: Single Family Dwelling By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070621 Application Number. A20070621 Tax Map No: 523400-309-007-0002-026-000-0000 Permission is hereby granted to: RACHEL KINGSLEY For property located at: MALLORY Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RACHEL KINGSLEY 48 MALLORY Ave Single Family Dwelling $130,000.00 QUEENSBURY,NY 12804-0000 Total value $130,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency GLENN BATEASE 71 BIG BOOM Rd QUEENSBURY, NY 12804-0000 Plans &Specifications 2007-621 1325 SQ FT SINGLE FAMILY DWELLING $159.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday, October 23,2008 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tpwn of ee u ue da October 23,2007 SIGNED BY ` 4for the Town of Queensbury. Director of Building&Code Enforcement Michael F.Travis nighw,-sly Highway Superintendent Department Home(518)798-0413 742 Say Road-Qu"nsburyi MY 12804 Thomas R.Vanness Hhway Sup 45 ice Phone:(5 18) 76 f-82 f f DepuHty omeig(518)7 -0929 erintendent Fax.-(5f 8) 745-4466 www.queensbury.net ,91 , DRIVEW" PERMIT DATE: Our o APPLICANT NAME: TELEPHONE NO.: 5is 116 :L6(7 ADDRESS TO BE INSPECTED: 416 RETURN ADDRESS: eo C'/�0_s )Ca (S �v �C) Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: (/Preliminary Approval NEED: ) Slight swale ) Deep swale (�evel with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( )12- ( )15" ( )18" ( )24- ( )36" Preliminary inspection completed by:7- 7//W4)�lg v Date: 914 7 Approval by Highway Su -.—Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ) Final Approval Rejected Date: Michael F. Travis, Highway Superintendent Thomas R. Van Ness, Deputy Highway Superintendent OFFICE USE ONLY _____. _- - %.......................% . 7I 2— ._ ..... TAX MAP NO. — PERMIT NO. L FEES: PE I +ECREATION ENGINEERING �� (If applicable) --_.---- (ACT . PRINCIPAL STRUCTURE: IN =c , APPLICATION FOR ZONING APPROVAL & BUILDING PERM A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER:COL0­0 1 0."T �Q. OWNER: n , ADDRESS: ADDRESS: P(Z(� 5 a PHONE NOS. �g " (o�� (�t� PHONE NOS.21g 7?6 7 C0 CONTACT PERSON FOR BUILDING & CODES COMPLIANCE:if Ilen <,�Z PHONE:5-f t 561 ISd-b LOCATION OF PROPERTY: SUBDIVISION NAME: c:. PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR z 0 d d w L U) PROJECT O H H 0 J O F- _ p LL Q � U Z Q Q "1Q z O F- 1- O1- � WZ e- U) N Cn O LL LL SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF,IBUSINESS: ESTIMATED CONSTRUCTION COST: j '3yl" 'W FUEL TYPE: HEAT TYPE:&,,, Ot a,'c: *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): ZONING CATEGORY: (J-f--1 D ARE THERE WETLANDS ON THIS SITE? Ale) IS THIS A HISTORIC SITE? A*) PROPOSED USE OF BUILDING OR ADDITION: *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 aTown of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? MO ARE THERE EASEMENTS ON PROPERTY? MO I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agre to the above. Signed -''107 Director of Building &Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above ; This application / proposed action described Applicant to erect or alter the building ; herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. o Application: ; 00 , , '10 2, , BUILDING & CODES A ROVAL ; ZONING APPROVAL 11 Z DAT ; DATE 01 QUESTIONS? CALL 761-8256 OR EMAIL codes0gueensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.ciueensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: j Town of Queensburyj • Community Development Office - 742 Bay Road, Queensbury, NY 12804 .I.I..I.I I OFFICE USE ONLY "o/f TAX MAP NO. PERMIT NO. rl r- -P PERMIT FEE APPROVALS: ZONING TOWN CLERK = U 0 2 2007 ­-­-­--­--­ wrrrrrrr.rrwwrrr.......... ... APPLICATION FOR SEPTIC DISPOSAL SYS A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. OWNER' Cl �1 S�- INSTALLER: ADDRESS* Rn -ADDRESS: 'It If� (rkck-ktwy �XOPIBJ PHONE NOS.-5/2 29� 26, 2 PHONE NOS. S(?-, LOCATION OF INSTALLATION z16 Mai CA(-IQ 3d. 7................................. RESIDENCE INFORMATION, YEAR BUILT NO.0 x compuTA-noN. TOTAL DAILY FLOW BEDROOMS GARBAGE GRINDER e 1980 or old X 160 gallon per bedroom INSTALLED? hi o .................... 30 gallon per bedroom SPA OR HOT TUB .....................­­...- 1992-pres;W 13.......... X I 10 gallon per bedroom . INSTALLED? a ti PARCEL INFORMATION: ✓ T,OPOGRAPHY: FLOAT OLLING ,/ STEEP SLOPE— %SLOPE— ✓ SOIL NATURE: SAND LOAM— CLAY— OTHER ✓ GRQQNDWATER: AT WHAT DEPTH? BEDROCKIIMPERVIOUa MATERIAL: AT WHAT DEPTH? ✓ DOMESTIC WATER SUPLY: MUNICIPAL-Z- WELL— j (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS AFT. ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each garbage grinder, spa or whirlpool tub., ✓ SEPTIC TANK: _I.C>Oro -GALLON (MIN. SIZE IS 1,000 GAL.) TILE FIELD: EACH TRENCH—FT. ✓ TOTAL SYSTEM LENGTH: SEEPAGE PIT(S : HOW MANY? )1J1w ✓ SIZE OF EACH NIA FT.X_FT. ✓ SIZE OF STONE TO-Bg USED: #- !I DEPTH OR THICKNESS FT. ✓ BED SYEEM SIZE —X� ! ✓ ALTERNATIVE SYSTEM: LENGTH ANDIOR SIZE_ ✓ HOLDING TANK SYSTEM:(if required) NO.OF TANKS:_ISIZE OF EACH ✓ GALLONS.ITOTAL CAPACITY.,_GAL. ... *...........""" , * '" *...... ............ . ,....................­`...................... .................................. ........ NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. ...........­,. ' ........................ ........................... ............................... For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known bOr on behalf Of an applicant,shall be void. I have read the regulations with respect to this application and QUESTIONS? CALL 7614266 OR EMAIL agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordina Co. Or VISIT OUR WESSITE FOR MORE INFORMATION www,Quftnzb=-mt1 Signature of Person Responsible Date Town of OueenLgb-u"I 7-76Z 6 tY1 G``\���( C �� I'' OCT 0 2 2007 x l� 1 e'CQ- 1 �0•d �dlol ��2�����i Nil �2�d�" ��-���, f villa ! OCT , a `0 V C F E LGi'�SC�f;F Y A BUiL6lNC7 °v, Go�ES o fit I• �� _ � iiwi V f r od s ! -19 I r o a W g no Oki .u►r z► ..ln S..0 Cam! CL 14 S A QQOALY SNR )1d'YntYnw x'TA .T ktVCV"J i0•d Lb0»99 os woad 9t?:z0 0061-sz-ddw lam, { Sr iAtolorslip dog* CI �v. o TIC 19-5 ll S �o.,.\\ - i 27"-Svw WIDEv ONE STORY CUSIT Frar © a SINGLE FAMILY DWELLING �- � °4� ) � BUILT FOR THE 'STATE OF NEI -� DESIGN CODES DESIGN CRITERIA i 0 9"CA"CWN A 2 FJWII.Y PWOMMO COOK PLOOR UVB&JMAV--40 P.B.F. PACK p�QRIMTtON t oov�sMsar 992 CA"BTAIR OJt+DJi1RTIitY WmO EP9E0-96 X.P.H. � a rwo�e r�.wil s usarm ►t,AN Jr9a J+IRC iiROUND Bmaw Lo"- 20 P.". s as"A ro" WZ HATS""66SCTJUC CODS RODE Do"LOAD-40 P.S.F. s NvAe twrow s •Lvwtwa�earwtLs TaAtnto�s�sso �►txR ;Rama ONSION""GORY-8 s rur tNo no ►A.WsfOft IDJrt tltliiit • ItMiCN CROtr iEClJON t Nfr OCCUPANCY CL""ZTACHM 0N6 i TWO FAMILY DM►9LUM"MOO~gvg%*VMSW as uoys+vsNrcNwwr 14 i'LEG7'1tIGAL LOAD CAI.CLLATlON ,»•�••y:«+ Away •• CONST.T►p$CLASSIMCAT ROX--UNPROVSCUM WOOD FRAMN 12 Tots rtxtl�.w........ AmaVwAldrr CJ:JLINO imxuCAncw-J63s owr�•.! 'JL� .ti...n.�w..w.....r+��.+.�.i WALL JJJ9IA.AT/OIi-lO49 • �A�� DAYB-.7D6a DRSTINATlONt • INDOOR D094M ISNP—TZ F m OtITaIDi DipON TEM/�--7 J� , w/iYrr W H.'r4aaMNafg�aOrawanwr+r.nraMrswsrww�MCl�wn.or wMrcrswrr�wworwseaurw,t�ww�awWwrirr.arew�noxwrw�n P/IiOO M0�3tULAR DEALRRtl�R[RMYIIdOb Nd21S8 ars es�rraTne w ""w o.'w.rc rw.er#*WAS w ao�rrta.r rwwwnswswewaewmw+awateroe+r..waw.r.aeesaa +�y SENUti NHRENAlt,MY w~,APanwil • , u �°im ,..+wIOU TOMB r.wttr.�twawt,ta..�e...,�...r.,...M+e„.,t�...�.........a.,....��.,..,,,.M.. rwtrirrtrtwatrro+r..wworwtrtwa. Inspiration panch Homes 1111JY` a'" ogee'a Pleasant Valley Modular Homes, Inc. Standard Features Floors f 16"Floor Centerl: 7_6Z 2"x 10"Floor Joists, 16"On-Center // Interior: Double 2x10 Perimeter Joists Primed,Finished Drywall Throughout,Including All Closets 3/4"OSB Tongue&Groove Floor D i E 8'Flat Ceilings Throughout with Finished Drywall No Standard Floor Insulation f 25 oz.Saxony Plush Carpet Installed I, 5.5#Rebond Carpet Pad Exterior Walls 1716"On-Centerl: i Tack Strip Carpet Installation with Carpet Bars 2x6 Graded Wall Studs, 16"On-Ce OCT 0 2 qp07 No-Wax Vinyl Flooring 8'Exterior Sidewall Height GU � Pre-hung 32"White 6-Panel Interior Doors(Most Areas) J R-19 Fiberglass Insulation Lever Handles&Mortised Hinges on All Interior Doors BUILDING OQILIEENzz Pi Ry Floor Mount Door Stops(Most Areas) Exterior: Double Four Vin I Sidin 8, CODE Designer-Coordinated Window Treatments Y g Hanging Dining Room Chandelier 7/16"OSB Sheathing Under Siding&On Marriage Walls Ceiling Light Fixtures in All Bedrooms House Wrap Air Barrier Vinyl Gad Wardrobe Shelving in Closets and Pantries Fiberglass 6-Panel Front Door Vinyl Foyer Entry Fiberglass 2-Cite Rear Door White Wood Moulding Profiles Exterior Light at Front and Rear Door White Window Sills Vinyl Thermopane Windows with Low"E"Glass and Grills 15"Raised Panel Shutters on Front Elevation Kitchen: 8"Deep 33"x 22"Double Bowl Stainless Steel Sink Roof r16"On Centerl: Single Lever Delta Kitchen Faucet with Sprayer 5/12 Pitch Roof with Shingle Over Ridge Vent Soffit Light Over Kitchen Sink(Most Models) 30-Year Architectural Fiberglass Roof Shingles Raised-Panel Oak Cabinets with 3/4"Solid Oak Face Frames Eaveguard Ice Shield Concealed Cabinet Door Hinges 6"Fascia and Vented 6"Soffit Pewter Color Door and Drawer Pulls 120-Pound Ground Snow Load Roof Rafters-46"0.C. 25"Deep laminate Counter Tops Smooth Finish Drywall Ceilings Ceramic Backsplash on All Counter Tops R-33 Cellulose Ceiling Insulation in Standard 5/12 Roof Metal Drawer Guide System (Opt.R-38 As Required in Some Areas) Drawer-Over-Door Base Cabinets Adjustable Shelving in Overhead Cabinets Heating: Shelving in All Base Cabinets No Standard Heating System Bisque Kitchen Appliances: Plumbing: General Electric 18 Cubic Foot Two-Door Refrigerator No Standard Water Heater General Electric 30"Free Standing Gas Range Outside Water Faucet 30"Non-Vented Range Hood with Light Water and Drain Lines Stubbed Through the Floor Plumb and Wire for Washer Baths: Water Shut-offs at All Fixtures Fixture Color is White Single Lever Delta Faucets on All Bath Fixtures Vitreous China 1.6 Gallon Water Saver Elongated Toilets Anti-Scald Valves on Tub/Shower Units 36"High Oak Vanity Cabinets with Generous Storage Wire and Vent for Dryer China Sinks with Overflow and Pop-Up Assemblies Delta'SBS'Bath Faucets with Anti-Scald Shower Valve Electrical: Armstrong No-Wax Vinyl Flooring Built to the National Electric Code Laminate Vanity Tops 200 Amp Service with 40 Spaces Medicine Cabinets and/or Light with Mirror Copper Wiring Throughout 60"One-Piece Fiberglass Tub/Shower Units Pewter Color Light Fixtures Throughout 36"or 54"One-Piece Fiberglass Shower Stalls in Glamour Baths Wired Smoke Detectors with Battery Back-Up Fiberglass Soaker Tubs in Glamour Baths as Shown Two GFCI Protected Exterior Receptacles Tub Drape at 60"Tub/Shower Units Switched Receptacle in Living Room Lighted Exhaust Fan in Bath Bisque Color Electrical Switches and Receptacles All representations and descriptions of the Pleasant Valley product are believed to be accurate at the time of publication. Due to continual product improvement and changes in design and material suppliers, we cannot guarantee pricing and exact duplication of every product mentioned herein. Model availability and specifications are subject to change without notice. Your Retailer/Builder is not an agent of Pleasant Valley Modular Homes,Inc. They,as an independent party,are responsible for your purchase contract and for any and all deletions,additions, alterations, or attachments made to or in your home. Updated 01/07 ✓toµ *„.Rim ` �`+ ; # Co U) S. 'a •iF ) ° ; c .t�T� N i d '••'�- .i'-'� O O `� •r•��V r�s • 1 i �i f: �F- � cn Q � O _ E .0 U -0U) xa g 1 Lo LL O V ,J( W pp qu - f _ V UAU co Ti � q r f WPit N a �4 yetis.. MA +EY ., ) - ?•lilt_ M_f.ir it �5 s i P 3 "IAl r J CL V 3 o .40 as � d d nol, � N V. x i f �` TOWN OF QUEE SBURY 742 Bray Road, Queensbury, NY. 12804-5902 January 29, 2008 Dawn Sweet 46 Mallory Ave. Queensbury, NY 12804 Re: Building Permit 2007-621 Tax Map Parcel: 309.7-2-26 Dear Ms. Sweet: I am writing you with regards to the above-referenced building permit in order to document our conversations recently regarding the same. As discussed, your project will require an Area Variance from our Zoning Board of Appeals. Specifically, you have constructed a front entry deck to your home in violation of the minimum setback requirements for the Single Family Residential, (SFR-10) district. I recently met with your contractor, Mr. Derico and we discussed your application. Please note the February 15, 2008 submittal deadline if you wish to have your project considered for placement on the March 2008 agendas. Should you have any questions or comments regarding your application, please do not hesitate to contact this office. c ely, alg Brown oning Administrator CB/sh L:\Craig Brown\2008 letters\Denial Sweet 1_29_08.doc "Horde of Natural Beauty ... A Good Place to Live " Rough Plumbing / Insulation Inspe tion Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart: /4)i am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: C+ ` CT- NAME: PERMIT #: LOCATION: INSPECT ON: .i TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Ad-1-Head t�zP.S. r 15 minutes Insulation/ esidential Check/Commercial Check Tyvjm imilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7� Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: arn/p, epart: arn/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT 60 Z t LOCATION: — DATE: TYPE OF STRUCTURE: Comments: Yei I No WA ,C Building Number Address visible from road Chimney Height/'W Vent/Direct Vent Location Fresh Air Intake 00. 3 inch Plumbing V 6 irx*m Roof Exterior Finish Com Platform at all e !- Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade - _ Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall y�-- Interior/Exterior Railings 34 inches to 38 inches Deck B / ftffv Com liant -iSrade away from foundation 6 inches with 10 fee U—NICH nice Gas Valve shut-off e /regulator 18 inches above grade1 Interior privacy I trim/doors I main entrance 36 inches Bathroom/Kdc hen watertight S /Win stairweps safe Interior Smoke Deoctor /Carbon Wde dacha Every level: E ry Bed Outside every bedi area: Inter ry backup: Attic access 30 inches x 22 inches x 30 inches in accessible area Crawl Spaces 18 inch x 24 inch access,1 sq.1-150 sq.ft.vents Bathroom Fans,d no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft Emergency egress below grade Gas Furnace shut-off within 30 feet or within One of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Va s installed/Heat Trapt Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W G um Basement stairs dosed rise>4 inches Garage Flom Pitched Ga e fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas PipeBond'ng As Built Septic System/Sewer De . Inspection Sticker Site Plan /Variance red Flood Plain Certification,if fired Okay to issue C/C or C 10 Temporary/Pennenent LABuilding&Codes Forms\Suddding&Codes\lnspec ion Forms\ReskWndW Final inspection Form—revised 100405.doc;Revised January 7,2008 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: �. NAME: Q LOCATION: PERMIT Final Survey Plot Plan Avvroved Denied The attached final survey has been received by the Dept.of Community Development. Upon review the s e been: Craig own, Wing Administrator Notes: 1 by L:\SueHemingway\Building.Codes.Inspection•FORMS\Final Survey Zoning Administrator.doc LANDS N/F OF REBECCA S. POWERS LANDS N/F OF 1103/316 MANUEL & RACHEL CINTRON DEED REFERENCE: IPF IN CONCRETE 1222/39 REBECCA S. POWERS LANDS N/F OF f /k/a REBECCA S. LINEHAN LOT 1 ROBERT JOHNSON TO \ — x S80°38- RACHEL K. KINGSLEY �`- x 26NE 1383/1 DATED: JULY 21, 2004 y66- 75, k BOOK 1396 PAGE 237 N �--- M CU IPF 3 I.00 27.5' � � + -----� 50 00 6 Ile 04 c^o , — IPF V- 00 — — W LOT 2 MAP REFERENCES: Z o a � AREA w MAP OF THOMPSON PROPERTY 0IL 18, 783 sq. ft. CORNER OF �_ 0 SHERMAN & MALLORY AVENUES W � �- 0.43 acres � DATED: JULY 23, 1946 BY: L.A. MERON, P.E. r MAP OF LANDS OF 27.5' —_ ROBERT J. KYSER �� co - l AND — — 147.61, '�� N i ALFRED F. LUCCI �- --� 0 DATED: OCTOBER 10, 1968 __ o REVISED: APRIL 30, 1969 LEGEND: BY: COULTER & McCORMACK — 206, �-_ _ O IPF = IRON PIPE FOUND MAP OF LANDS TO BE MORTGAGED BY 57,NDb 7g°0413 � O IRF = IRON ROD FOUND PATRICIA M. MORRI, III 2 Hr -� O IRS = IRON ROD SET/TO BE SET DATED: NOVEMBER 29 1986 — N BY: COULTER & McCORMACK Q x = FENCE LINE a _ LOT 3 �, = UTILITY POLE F•-; _ ___ = LOTS FROM MERON MAPCq N Melt I O LANDS N/F OF KINGSLY � LANDS N/F OF �- HALLMARK NURSING CENTRE, INC. LOT 4 IRF I HEREBY CERTIFY THAT THIS MAP WA5 PREPARED FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SMALL RUN ONLY TO THE PER50N5 FOR WHOM THE SURVEY WAS PREPARED. AND ON THEU2 c;26b ( BEMALF TO THE TITLE COMPANY. GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON. f CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL — INSTITUTIONS OR SUBSEQUENT OWNERS. CERTIFIED TOr DAWN SWEET PIONEER SAVINGS BANK. IT'S 5UCCE55ORS AND/OR ASSIGNS GMICAGO s MPANY IRS LOT 5 dr� s CERTIFIED 5 JPF MA C. S N 135 DATEDr OCTOBER 2. { x0_ 135v a� u ,S' �GlVEY Date, ❑CTOBER 19, 2005 P BEARING, A L ENSED L N OR RVEYV N S L 15 A & MAP A"�°°`-S �""�SAL 6 A Map of a Survey made for Scale 1'=20' vaurloN of seenoH nos.sue-aHs,or�z OF nle S IJFW PORK STATE ET)l1CTHE O uN.• 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY NARKED VWTH AN ORIGINAL OF THE LAND SURVEYORS SEAL SHALL BE CONSIDERED ro BE VALID TRUE COPIES' -CERRFlEY WAS INDICATED IN ACC y�Y MTN DAWN SWEET S 1 Land Surveyors By YO STATE IN ACCORDANCE ATH THE MSTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED BY rl/E NEW OM STATE ASSOgATION OF PRDPESSIDNAL 1.1N0 SURVEYORS.SAW CERTIFICATKINS SHALL RUN ONLY TO THE PERSON FOR Y'".THE SURVEY IS PREPARED.AND ON EIS AND LENDING TO THE S'nT CON LIST, HEREON,AND 169 Haviland Road Queensbury, New York 12804 TO THEAL ASI NEESO 'THE LENDING LISTED HEREON.AND Town of Queensbury, Warren County, New York ro,HE ASSIGNEES OF nE LEHpDTG INSTITUTION.* 1 10/19/07 PROPOSED HOUSE LOCATION (518) 792-8474 New York Lie. No. 50135 KINGSLEY C 1654 NO. DATE DESCRIPTION DWG. NO. 05204A 309.7-2-26 & 27 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/ m epart: I 0 �i am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: %.lv NAME: PERMIT NO.: co LOCH INSPECT ON: C� /KECHECK: Comments and/or diagram Soil Type: Sand Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + - Y N N/A Absorption Field: Total length Length of each trench Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field I Pit Opening Sealed: Y N End Cap Y N Inlet/Outlet Pipes&Baffles Y N Location Separations Foundation to tank ft. Foundation to absorption ft.— Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N Location of System on Property: Front ear Left Side Right Side Middle Front Middle Rear s m Use , 6Ap ;� Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 U\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc F Final Survey`Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: . 4 NAME: LOCATION: q4 PERMIT#: � Final Survey Plot Plan Avvroved Denied The attached final survey has been received by the Dept.of Community Development. Upon review the survey has been: Craig Brown,Zoning Administrator Notes: a L:1sueHemingway\Building.Codes.Inspection.FORMS\Fina1 survey Zoning Administrator.doc LANDS N/F OF REBECCA S. POPPERS LANDS N/F OF 1103/316 MANUEL & RACHEL CINTRON DEED REFERENCE: IPF IN CONCRETE 1222/39 OF f/k/a BREBEC A S. LINEHAN LOT 1 ROBERT JECCA S. POWERS LANDS O F SO 1 S8p� , HNSON TO RACHEL K. KINGSLEY X �26=_ 1383/1 DATED: DULY 21, 2004 CRUSHED a) BOOK 1396 PAGE 237 STONE M DRIVE CY IPF DECK 0 30.95' ~�� 5 T?2926 to IPF N 0 Z LOT 2 b MAP REFERENCES: W 1 STORY WOOD FRAMEDAREA MAP OF THOMPSON PROPERTY I HOUSE 18, 783 sq. ft. Pq CORNER OF 0.43 acres SHERMAN & MALLORY AVENUES W I y DATED: JULY 23, 1946 BY: L.A. MERON, P.E. MAP OF LANDS OF Cl) ROBERT J. KYSER AND 147.36' ALFRED F. LUCCI o DATED: OCTOBER 10, 1968 �, __ COREVISED: APRIL 30, 1969 — LEGEND: BY: COULTER & McCORMACK , O IPF = IRON PIPE FOUND 57 206. 1 �_ � MAP OF LANDS TO BE MORTGAGED BY >-�i PATRICIA M. MORRIS III � N78o04032Ew �.... O IPF = IRON ROD FOUND DATED: NOVEMBER 29, 1986 � 1 O IRS = IRON ROD SET/TO BE SET c = FENCE LINE c BY: COULTER & McCORMACK Q LOT 3 x �o� = UTILITY POLE a LOTS FROM MERON MAP u r C LANDS N/F OF KINGSLY '� LANDS N/F OF �� HALLMARK NURSING CENTRE, INC. LOT 4 IRF iN C. At �, . . IRS - { LOT 5 PF 35 D Dater C B R 1 , 2005 'UNAARING12FD ALTERATION LAND OR ADDITIOSURVEYORS S L SURVEY VOL BEARND A I'�'��� SAL H A Map of a Survey made for Scale 1'=20' VIOLATION OF SECTION 720St,SUB-gNSION 2.OF 7!E ,/\�'���' PUG. P NEIN YOW STATE EDUCATION UW.' I`/ �/ `./ ONLY COPIES ORIlom THE M DIE I Oi SU SURVEY MARKED MTH AN OIOf#NAL OF THE LAND SURVEYORS SE&SNAIALBE CONSIDERED TOBEVAIJD TRIVE COPM DAWN SWEET S- 1 CERRi1CAT10NS INDICATED NEREON WNIFY THAT 7W5 SURVEY WAS PREPARED N ACCORDANCE TM1H THE Land S urveyo r S By THE INO CODE °"AT"C"°R`11"°�` �DP� er THE NEE ORS. STATE ASSOCUTION S PRORUN O Al L/ND SURVEYORS.SAID CER1Ti1CATN7NS SHALL RIM pR.r ro,HE fOR WM, MPR�� �'AND 2 O1/1%8 FINAL SURVEY SF�EI'j pp 1 ON MS BETIAtf 1T)7TR:TITLE COMPANY,GOVERNMENTAL 169 Haviland Road AGENCY AND LENDING NBRTUMON LISTED +.AND Queensbury, New York 12804 TO THE ASSIGNEES Or THE UMM INSTITUTION.' Town of Queensbury, Warren County, New York 1 10119107 PROPOSED HOUSE LOCATION KWGSIEY C 1654 518) 792-8474 New York Lic. No. 50135 NO. DATE DESCRIPTION DWG. NO. 05204A 309.7-2-26 & 27 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pmDepa�rt: am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: 6�7 '(Q Z LOCATION: DATE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake S 3 inch Plumbing Vent through roof minimum 6 inches G Roof Complete/Exterior Finish Complete Platform atall exterior doors s Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more -- Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall " Interior/Exterior Railings 34 inches to 38 inches D2_ —1 Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade ' Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: l ' Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s . ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulationi��� 7v Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade �� -� Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required F ification,if required'_ Okay to issue /C or C/ emporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc r,-/ Jac T 0 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: �lCam/pm Date Inspection request received: Inspector's Initials: t L NAME: r ^ �"�-� PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments Yes N N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location1, Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches �;-t� (ZAA4-5 1T;K_ Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more - Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches 40� Interior Handrails @ stairs 2 or more risers ��t� Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate I Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen water-tighte � 1 �� Safety glazing/Wi5Liow in stairwells safety in Interior Smoke D ctors: � � Every level: Eve edr m: Outside every bedroom�� _ l_ }�W LA Inter Connected: �t�t//// Batte backu Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s . ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation V Floor truss,draft stopping finished basement 1,000 s . ft. Emergency egress below grade ` Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp, 110 Enclosed Stairs Sheetrock Underside minimum/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart: �� am/pm Date Inspection request received: Z 1 Inspector's Initials: 4 a — NAME: PERMIT#: ��� LOCATION: DATE: TYPE OF STRUCTURE: Comments Yes Nd N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches �� � C Roof Complete/Exterior Finish Complete Platform atall exterior doors s Guards at stairs,decks,patios more than 30 inches above grade I"1i Guard at stairwell at 34 inches or more 1-� Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers _ Grade away from foundation 6 inches with 10 feet 6 � 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing �j Interior Smoke D ectors: Every level: E Be ry oom: Q` Outside every bedroo area: Inter Connected: Battery backup: V y�•�, Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s . ft.-150 s .ft.vents �� Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. V egress below grade Gas Gas Furnace shut-off o within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area V �t Furnace/Hot Water Heater operating Low water shut-off boiler 1` Relief Valves installed/Heat Trap/Water Temp, 110 l Enclosed Stairs Sheetrock Underside minimum%z"Gypsum � �� Basement stairs closed rise>4 inches Garage Floor Pitched r�►� 1-., Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical hhXX Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required t Okay to issue C/C or C/O[Temporary/Permanent) L:\Building&Codes Forms\Building&Codes\Inspection Forms s ential Final Inspection r _revis _ doc Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: _am/`� Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:TLC, NAME: °i°% PERMIT#: — LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width above footing 6 mil 1 r wet areas under slab Backfill Appro al lambing er Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ; A.� NAME: PERMIT#: LOCATION: INSPECT ON: - TYPE OF STRUCTURE: Comments Y N N/A (EFootings. Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place kkAl� 6 - Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch atop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector NAME: :S V PERMIT#: r LOCATION: ! INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings _' Monolithic Slab Reinforcement in Place C � The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart:�_ -___am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: r NAME: PERMIT NO.: LOCH INSPECT ON: Comments and/or diagram Soil Type: Sand Loam/ Clay Type of Water: Municipal/ Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' + - Y N N/A Absorption Field: Total length ft.Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number b� Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field Pit Opening Sealed: Y N End Cap N Inlet/Outlet Pipes&Baffles Y N Location/ Separations Foundation to tank ft. �� - Foundation to absorption ft.— Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Statua: 7Approved ,Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 U\Building&Codes Forms-01-1)\Building&Codes\Inspection Forms\Septic Inspection Report.doc Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd., Queensbury, NY 2804 Inspector's Initials: NAME: PERMIT NO.: t6421 . LOCATION: &4J10Cy INSPECT ON: RECHECK: Comments and/or diagram Soil T Sand a Type of unici Welt Wate Waterline se ra o istance ft. Well separation distance ft. Other wells: 6 ft, SkAA, �� �-'0L*Jt) -Absorption Field: Total length ft. Length of each trench x7l Depth of trenches Size of Stone 2 Seepage Pits: Number i�/� li?CL.RJE� Size: t4lx Stone Size: Piping Size TyDe Building to tank Tank to Distribution Box Distribution Box to FWkd Pit ze Opening Sealed: Y Partial End Ca E -- I Inlet/Outlet Pipes&Baffles I SLY N Location Se rations` a Foundation to tank Foundation to absorption 2b2_2 ft. Separation of Pits ft. Conforms as r Plot Plan Y N En ineer Report and As-Built YW.N ZoVL��- -) Location of System on Property: '�' Front Rear Left Side Right Side ( -- Middle Front Middle Rear System Use tat s: Partial Approved'-ad needs to be re-inspected, please call the Building&Codes Office Last revised 021006 Last revised 1/6/05 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering Phone: (518)745-0307 g 9 Fax: (518)745-0308 January 10, 2008 Town of Queensbury Buildings Department 742 Bay Road Queensbury, NY 12804 Reference: 46 Mallory Ave Residence Wastewater System Installation I have inspected the installation of the new wastewater system at the referenced property. A new 1000 gallon precast concrete septic tank and 165 LF of conventional pipe-in-stone absorption trench has been installed. To the best of my knowledge, the system is installed in general conformance with the attached record drawing. Should you have any questions, please contact this office. Regards, �6d G. Thom Hutchins, P.E. Cc. Dawn Sweet w/ record drawing G.Thomas Hutchins,P.E. Perm' # Ilermit l5ate IL REScheck Software Version 3.7.3 Compliance Certificate Project Title: Dawn Sweet Report Date: 10/19/07 Data filename: C:\Documents and Settings\VISION Engineering\My Documents\VISION ENGINEERING\Projects\Projects 2007\Plans\Sweet\sweetrevised.rck Energy Code: New York State Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 16% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: Mallory Avenue Queensbury,NY 12804 • • • or Door ' r ••- Glazing a • EMM Ceiling 1:Raised or Energy Truss: 1312 38.0 0.0 33 Wall 1:Wood Frame, 16"o.c.: 1207 19.0 0.0 60 Window 1:Vinyl Frame:Double Pane with Low-E: 116 0.350 41 Door 1:Solid: 22 0.160 4 Door 2:Solid: 22 0.170 4 Door 3:Glass: 40 0.350 14 Wall 2 Bsmnt Bilco Wall:Wood Frame,16"o.c.: 48 21.0 0.0 2 Door 4:Solid: 20 0.200 4 Basement Wall 1:Solid Concrete or Masonry: 1130 0.0 10.0 122 Window 2:Vinyl Frame:Double Pane with Low-E: 46 0.360 17 Furnace 1:Forced Hot Air:92 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the t of is er knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. cc-.Ix L° /M 6-7 Bu der/Desi Company Name �. Date a; #`, ! 'f Dawn Sweet �J Paj��Of 4 ciREScheck Software Version 3.7.3 Inspection Checklist Date: 10/19/07 Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: ❑ Wall 2 Bsmnt Bilco Wall:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,7.8'ht/5.0'bg/4.0'insul,R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade) insulation and extends at least 6 in.below grade. Windows: ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.360 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.160 Comments: ❑ Door 2:Solid,U-factor:0.170 Comments: ❑ Door 3:Glass,U-factor:0.350 Comments: ❑ Door 4:Solid,U-factor:0.200 Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:92 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: _.... .....,.Dawn Sweet Page 2 of 4 ❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11. ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6. ❑ Supply ducts in unconditioned spaces must be insulated to R-11. ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R- ❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2. .Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Fireplaces: ❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an onloff heater switch and require a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. _... Dawn Sweet Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Dawn Sweet Page 4 of 4