2007-667 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE (.3"Vc OCCUPANCY
Permit Number. P20070667 Date Issued: Friday, May 01, 2009
This is to certify that work requested to be done as shown by Permit Number P20070667
has been completed.
Location: 2952 STATE ROUTE 9L
Tax Map Number. 523400-239-020-0001-013-000-0000
Owner. DANIEL & SUZANNE LOMBARDI
Applicant: DANIEL & SUZANNE LOMBARDI
This structure may be occupied as a:
Residential Alteration By Order of Town Board
NSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20070667 Application Number. A20070667
Tax Map No: 523400-239-020-0001-013-000-0000
Permission is hereby granted to: DANIEL& SUZANNE LOMBARDI
For property located at: 2952 STATE ROUTE 9L
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: DANIEL& SUZANNE LOMBARDI Residential Alteration $12,000.00
MICHAEL NOVAK
3 CLINTON Sq Total vane $12,000.00
ALBANY,NY 12207-0000
Contractor or Builders Name/ Address Electrical Inspection Agency
Plans &Specifications
2007-667
RESIDENTIAL ALTERATION
$40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday, December 17,2008
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the f 4 o y, December 17, 2007
SIGNED BY b for the Town of Queens
bury.
ury.
Director of Building&Code Enforcement
__________________•_-n-'_ OFFKE USE ONLY..................
�_"__._.,__..__._.____-__.___.'
/t
�6
0 ,
TAXA . �r1 10
PERMIT -
.
FEES: PE EAT. ENGINEERING
(If applicable)
... ....... ............................ ;...•`._`, '
W=
/
••.................
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: OWNER; \_nkQ (
ADDRESS: ADDRESS: 3 q\��C r
L�V-k,,t.,A^1 --3� 1� I t -0
PHONE NOS. PHONE NOS._
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE:b2Ln �o Mc 63*' PHONE: 09(
LOCATION OF PROPERTY:
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT
APPLY TO YOUR z O O C� u- cn
PROJECT E O }. O p = _
u. Q U
LLIo Z
z Q Q r. U) NU) O1LL OUi CL206
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
or
ATTACHED
GARAGE(1,2,3)
OTHERY��d&4kq 4
A�
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: / CIGy "' FUEL TYPE:
HEAT TYPE: U f "HOW MANY FIREPLACE(S�AND/OR WOODSTOVES(S}—
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING OR ADDITION: �J a 1�.���, S4ro..4 e
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office
B 3-LGL 1 i-OS
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY? 1 �/
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed
),21 IP 4_)&_4ZtZf,9 -
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
................................................... ..._................0
,
Permission is hereby granted to the above This application / proposed action described 10
o Applicant to erect or alter the building herein is found to be in accordance with the
01
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application: ; S
,
,
, , 10
, ,
,
, , , ,
, ,
,, ,
, ,
BUILDING & CODES APPROVAL ; ZONING APPROVAL 01
, ,
,
, 10
,
DATE ; � DATE ,
o 00 ,
,
,
:...................................................: :...._..._..._........_..._......._._................
QUESTIONS? CALL 761-8256 OR EMAIL
r codesom ueensbu ry.net
VISIT OUR WEBSITE FOR MORE INFORMATION
Office Use Only www.gueensbury.net
Operating Permit Issued: Yes No
Occupancy Type: Construction Classification:
Assembly Occupancy Limit: Special Conditions:
„<,.. Town o ueensbun Community Development Office 742 Bay Road, Queensbun, NY 12804
f Q J �J p .� y J
Queensbury Building & Code Enforceme t Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depart: \ a am/pm
Date Inspection request received: Inspector's Initials��
NAME: %` ��t G% , PERMIT
LOCATION: `` DATE: �T
TYPE OF STRUCTURE:
Comments:
Yes No WA
4' Building Number Address visible from road
Chimney Height/'B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches . `-"
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs decks,p@tios more than 30 inches above grade --- —
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Romp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to silt plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches \`��'
Bathroom/Kitchen watertight
Safetv glazina/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area p
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification �
Floor truss,draft stopping finished basement 1,000 s .ft. tJTZ�
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum''Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door doser
Duct work Sealed properly
Gas Loge in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10[Temporary/Permanent
LABuilding&Codes Forms\Building&CodeMinspection Forms\Residential Final Inspection Forrn_revise0_100405.doc;Revised
January 7,2008; Revised 6/26/08
Framing/ Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart to ! 1 m/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: ���
LOCATION: — INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z w 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center i
Ice and water shield 24 inches from wall i
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour 1
Firestopping '
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
^n¢nwc. ��o�-� +;1�
AS r U " al dui
Co
TOW (.:IFS UE' SBUR '
BUILDING� Sk CO �S DnTr�
Revie
Date
w--r-
-C
z _
If
Al
i
3
h
L
f
' N
i Z
L
r
%elz 3
fr
s
x
c�c
6
- N 3
v
r
713
x
i
3
i
i + r
I �
I � �i IH.GoN Y
r �
;1
F41401i
h,
i'l!Wkl
• r-i i--tl1 at. _ �
r j
h 2'
f
. s
r i
V £1
c ;
� o
t
wyo jl� r
olb
4,
4, ov
rl
7:5
j4.
--:3 -
J1
V�
ro
7P
OWN OF OUEENISBURY
RECEIVEn
1;: DEC 19 1990
Nye rft
BLDG. & CODE DEPT,
rrx2r
co 6 orr
7.3
Daniel Lombardi
Proj ect
#2952 Rt 9L, Queensbury,NY
10/26/07
General Comments:
No change to exterior walls or footprint.
No change in current window sizes.
Square footage will be under 500 square feet when project is completed.
Building will not be a livable structure.
No heating system will be installed.
Current baseboard electric heating will be removed and not replaced.
Current wood burning stove will be removed and not replaced.
Building will be reinforced and tightened up.
Interior:
Square footage will be eliminated.
All three bedrooms on 2"d floor will be eliminated, floors removed,
to create cathedral effect.
Kitchen stove and counter eating area will be removed.
Fake paneling on walls will be removed and replaced with TG wood.
New microlams will be used to replace old second floor floor joists that will now
be exposed due to removing of 2"d floor rooms and floors.
Old stairway to 2"d floor will be eliminated.
New stairs will be built from 1st floor to 2"d floor bathroom area that will
be remaining. Drawings show location.
Some electrical outlets will be removed since all bedrooms are eliminated and
floors removed.
Some new electrical outlets may be added (not yet determined if needed).
Exterior:
Cedar shakes will be replaced.
All windows will be replaced(sized the same)
Slider will be replaced.
Porch roof will be re-pitched per drawings.
No change in square footage of docks will be done.
No re-configuration of docks will be done.
Dock boards will be replaced.
Dock railings will be replaced(same configuration and style).
§RR314
STAIRWAYS
§RR314.1 Width. Stairways shall not be less than 36 inches (914 mm) in
clear width at all points above the permitted handrail height and below the
required headroom height. Handrails shall not project more than 4.5 inches
(114 mm) on either side of the stairway and the minimum clear width of the
stairway at and below the handrail height, including treads and landings,
shall not be less than 31.5 inches (787 mm) where a handrail is installed
on one side and 27 inches (698 mm) where handrails are provided on both
sides.
Exception: The width of spiral stairways shall be in accordance with
§RR3' e 5.
§RR314.2 Treads and risers. The maximum riser height shall be 8-1/4 inches NY
(209 mm) and the minimum tread depth shall be 9 inches (229 mm) . The riser NY
height shall be measured vertically between leading edges of the adjacent
treads. The tread depth shall be measured horizontally between the vertical
planes of the foremost projection of adjacent treads and at a right angle to
the tread's leading edge. The walking surface of treads and landings of a
stairway shall be sloped no steeper than one unit vertical in 48 units
horizontal (2-percent slope) . The greatest riser height within any flight
of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm) .
The greatest tread depth within any flight of stairs shall not exceed the
smallest by more than 3/8 inch (9.5 mm) .
§RR314.2.1 Profile. The radius of curvature at the leading edge of the
tread shall be no greater than 9/16 inch (14.3 mm) . A nosing not less than
3/4 inch (19.1 mm) but not more than 1-1/4 inches (32 mm) shall be
provided on stairways with solid risers. The greatest nosing projection
shall not exceed the smallest nosing projection by more than 3/8 inch
(9.5 mm) between two stories, including the nosing at the level of floors
and landings. Beveling of nosing shall not exceed 1/2 inch (12.7 mm) .
Risers shall be vertical or sloped from the underside of the leading edge
of the tread above at an angle not more than 30 degrees from the
vertical. Open risers are permitted, provided that the opening between
treads does not permit the passage of a 4-inch-diameter (102 mm) sphere.
EXCEPTIONS:
1. A nosing is not required where the tread depth is a minimum of 11
inches (279 mm) .
2. The opening between adjacent treads is not limited on stairs with
a total rise of 30 inches (762 mm) or less.
§RR314.3 Headroom. The minimum headroom in all parts of the stairway
shall not be less than 6 feet, 8 inches (2032 mm) measured vertically from
the sloped plane adjoining the tread nosing or from the floor surface of the
landing or platform.
§RR314.4 Winders. Winders are permitted, provided that the width of the
tread at a point not more than 12 inches (305 mm) from the side where the
treads are narrower is not less than 10 inches (254 mm) and the minimum
width of any tread is not less than 6 inches (152 mm) . The continuous
handrail required by yl1R315.1 shall be located on the side where the
......._...._................
tread is narrower.
§RR314.5 Spiral stairs. Spiral stairways are permitted for interior use NY
as a component of the means of egress from a habitable room, a basement or NY
an attic, provided the minimum tread width shall be 26 inches (660 mm) with NY
each tread having a 7-1/2-inch (190 mm) minimum tread depth at 12 inches NY
(305 mm) from the narrow edge. All treads shall be identical, and the rise
shall be no more than 9-1/2 inches (241 mm) . A minimum headroom of 6 feet,
6 inches (1982 mm) shall be provided. A spiral stair is not permitted to NY
be the only means of egress from a story of a building. NY
§RR314.6 Circular stairways. Circular stairways shall have a tread depth
at a point not more than 12 inches (305 mm) from the side where the treads
are narrower of not less than 11 inches (279 mm) and the minimum depth of
any tread shall not be less than 6 inches (152 mm) . Tread depth at any
walking line, measured a consistent distance from a side of the stairway,
shall be uniform as specified in .SRR314 .2.
§RR314.7 Illumination. All stairs shall be provided with illumination in
accordance with §.RR303.4.
§RR314.8 Under stair protection. Enclosed accessible space under stairs
shall have walls, under stair surface and any soffits protected on the
enclosed side with 1/2-inch (12.7 mm) gypsum board.
§RR314.9 Bulkhead enclosure stairways. Stairways serving bulkhead
enclosures not part of the required building egress and providing access
from the outside grade level to the basement shall be exempt from the
requirements of §RR312, §RR3i and §RR315 when the maximum height
from the basement finished floor level to grade adjacent to the stairway is
covered by a bulkhead enclosure with hinged doors. �'
§RR315
HANDRAILS
§RR315_1 Handrails. Handrails having minimum and maximum heights of 34
inches and 38 inches (864 mm and 965 mm) , respectively, measured vertically
from the nosing of the treads, shall be provided on at least one side of
stairways. All required handrails shall be continuous the full length of
the stairs with two or more risers from a point directly above the top
riser of a flight to a point directly above the lowest riser of the flight.
Ends shall be returned or shall terminate in newel posts or safety
terminals. Handrails adjacent to a wall shall have a space of not less
than 1.5 inches (38 mm) between the wall and the handrail.
§RR315.2 Handrail grip size. All required handrails shall be of one of
the following types or provide equivalent graspability.
Type I. Handrails with a circular cross section shall have an outside
diameter of at least 1-1/4 inches (32 mm) and not greater than 2 inches
(51 mm) . If the handrail is not circular it shall have a perimeter
dimension of at least 4 inches (102 mm) and not greater than 6-1/4 inches
(160 mm) with a maximum cross section dimension of 2-1/4 inches (57 mm) .
Type II. Handrails with a perimeter greater than 6-1/4 inches (160 mm)
shall provide a graspable finger recess area on both sides of the
profile. The finger recess shall begin within a distance of 3/4 inch
(19 mm) measured vertically from the tallest portion of the profile and
achieve a depth of at least 5/16 inch (8 mm) within 7/8 inch below the
widest portion of the profile. This required depth shall continue for at
least 3/8 inch (10 mm) to a level that is not less than 1-3/4 inches
(45 mm) below the tallest portion of the profile. The minimum width of
the handrail above the recess shall be 1-1/4 inches (32 mm) to a maximum
of 2-3/4 inches (70 mm) . Edges shall have a minimum radius of 0.01 inch
(0.25 mm) .
§RR316
GUARDS
§RR316.1 Guards required. Porches, balconies or raised floor surfaces
located more than 30 inches (762 mm) above the floor or grade below shall
have guards not less than 36 inches (914 mm) in height. Open sides of
stairs with a total rise of more than 30 inches (762 mm) above the floor or
grade below shall have guards not less than 34 inches (864 mm) in height
measured vertically from the nosing of the treads.
§RR316.2 Guard opening limitations. Required guards on open sides of
stairways, raised floor areas, balconies and porches shall have
intermediate rails or ornamental closures that do not allow passage of a
sphere 4 inches (102 mm) or more in diameter.
EXCEPTION: The triangular openings formed by the riser, tread and
bottom rail of a guard at the open side of a stairway are permitted to be
of such a size that a sphere 6 inches (152 mm) cannot pass through.