Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-0260-2020
PRINCIPLE STRUCTURE Office Use Onh PERMIT APPLICATION permit #:2.O20 -2oO%wD Town of Queensbury PermitFee:$_24742BayRoad,Queensbury,NY 12804 “Rec.Fee:$ NICr P:518-764-8256 wwwqueensburynet Invoice #:Zee& 12 Shore Acres Road,Cleverdale, Project Location:_Lake George,NY 12804 (Ron Ho se) Tax Map #:_227.17-1-11 Subdivision Name: TOWN BD.RESOLUTION 86-2013:$850 recreation fee for new dwelling units:single family,duplexes/two-family, multiple family,apartments,condominiums,townhouses,and/or manufactured &modular homes,but not mobile homes.This is in addition to the permit fee(s). CONTACT INFORMATION: Applicant: Name(s):Daniel and Meghan Frazier Mailing Address,C/S/Z:_8 Connors Way,Saratoga Springs,NY 12866 Cell Phone:_(518 _)376-5302 land Line:_( Email:__megfrazier2S@gmail.com Primary Owner(s): Name(s):_Daniel and Meghan Frazier Mailing Address,C/S/Z:_8 Connors Way,Saratoga Springs,NY 12866 Cell Phone;_(518 _)_376-5302 Land Line:_() Email:mesfrazier25@gmail.com O Check if all work will be performed by homeowner only Contractor(s):Workers’Comp documentation must be submitted with this application Contractor Name(s):_:Clarke Construction Contractor Trade:__General Contractor Mailing Address,C/S/Z:_88 Mohawk Mountain Road,Lake George,NY 12845 Cell Phone:_(518)361-2668 Land Line:_() Email:_isclarke3199@yahoo.com List all additional contractors on the back of this form Architect(s)/En: Business Name:Phinney Design Group Contact Name(s):Michael Phinney,AIA Mailing Address,C/S/Z:142 Grand Avenue Cell Phone:_()Land Line:_(518 __)587-7120 Email:_mphinney@ phinneydesign.com eer(s) Contact Person for Building &Code Compliance:__Brennan Drake,AIA Cell Phone:_{)Land Line:_(518)682-3438 Email:_bdrake@phinneydesign.com Principle Structure Packet Revised February 2019 PROJE INFORMATION: TYPE:__Commercial _Residential WORK CLASS: Single-Family __Two-Family __Multi-Family(#of units ___) Townhouse _Business Office _Retail _Hotel/Motel Industria/Warehouse __Garage(#ofcars__)_*Other(describe Bunk House _ STRUCTURE SQUARE FOOTAGE:GARAGE SQUARE FOOTAGI 1 tio _BOO SE floor: a 2"floor:_ 2m floor: Total square feet:_N/A 3"floor: Basement (habitable space): Total square feet:Spo” ADDITIONAL PROJECT INFORMATION: 175,000EstimatedCostofConstruction:$ 2.Proposed use of the building;_ Occ#sione!Guest Residence 3.If Commercial or Industrial,indicate the name of the business: 4.Source of Heat:Gas Oil Propane—Solar Other: Fireplaces need a separate Fuel Burning Appliances &Chimney Application,one per appliance) 5.Are there any structures not shown on the plot plan?YES NO X Explain: 6.Are there any easements on the property?YES NO X 7.SITE INFORMATION: a.What is the dimensions or acreage of the parcel?__?- 84 Acres b.Is this a corner lot?YES NO X c.Will the grade be changed as a result of the construction?YES X NO d.What is the water source?PUBLIC PRIVATE WELL X e.Is the parcel on SEWER or a PRIVATE SEPTIC system?Private Septic Principle Structure Packet Revised February 2019, DECLARATION: lacknowledge that no construction shall commence prior to issuance of a valid building permit and work will be completed within a 12 month period. 2.Ifthe work is not completed by the year expiration date the permit may be renewed, subject to fees and department approval. 3.|certify that the application,plans and supporting materials are a true and complete statement andior description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances,and in conformance with bal zoning regulations. 4,|acknowledge that prior to occupying the facilities proposed I,or my agents,willobtain a certificate of occupancy. 5.Lunderstand that Ive are required to provide an as-built survey by licensed land surveyor of alll newly constructed facilities prior to issuance of a certificate of occupancy. have read and agree to the above: PRINT NAME:Meghan Frazier SIGNATURE UOT DATE:5/28/2020 Principle Structure Packet Revised February 2019, Office Use Only FUEL BURNING APPLIANCE &Permit #:Qc -OZd-2029) CHIMNEY APPLICATION Permit Fee:$. Invoice #: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 wwwaueensburynet 12 Shore Acres Road,Cleverdale, Project Location: LakeGeorge, NY12804 Tax Map ID:_227-17-1-11 Room of Install: tivingRoom CRUNK HoSE) planned install Date:20 /FAU 2921 ONE APPLICATION PER APPLIANCE* CONTACT INFORMATION: Applicant: Name(s):Daniel and Meghan Frazier Mailing Address,C/S/Z:_®Connors Way,Saratoga Springs,NY 12866 Cell Ph.:_(518_)376-5302 Land Line:_() Email:_mesfrazier25@gmail.com @ Primary Owner(s): Name(s);_Paniel and Meghan Frazier Mailing Address,C/S/Z:_8 Conners Way,Saratoga Springs,NY 12866 Cell Ph.:_(_518_)376-5302 Land Line: Email:_™egfrazier25@gmail.com O Check if all work will be performed by homeowner only Installer/Builder:Workers’Comp documentation must be submitted with this application Contact Name(s):_J-Clarke Construction Contractor Trade:General Contractor Mailing Address,C/S/Z:88 Mohawk Mountain Road,Lake George,NY 12845 Cell Phone:_(518__)_361-2668 Land Line:_() Email:_jsclarke3199@ yahoo.com Contact Person for Building &Code Compliance:__®rennan Drake,Ald,Phinney Design Group Cell Ph:_(__)Land Line:_(_5i8_)587-7120 Email:__bdrake@phinneydesign.com Principle Structure Packet Revised February 2019 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove _*Fireplace Insert __Fireplace Fuel Fired Equipment (Garage Only,18”clearance per IMC 304.3) Fireplace,factory built** Manufacturer’s name:_Neat &Glo Model #:_SL~5/5%) SOURCE OF HEAT: Wood __Coal __Pellet ~Gas CHIMNEY INFORMATION: Masonry (require plans to be submitted): block __brick _®_stone Flue: tile steel size,in inches x ‘4 xX.double-wall triple-wall _*insulated Heat &Glo(*Manufacturer’s name:Model #:) ADDITIONAL INFORMATION: 1.Two inspections are required.A rough-in inspection,prior to installation and a final inspection,after installation. Manufacturer's installation manual must be available at the time of inspection. Masonry fireplaces &chimneys require plans to be submitted. Twenty-four (24)hour notification is required for inspections. Workers’Comp insurance information is required with this application. yen Declaration:Construction/installation must conform to NYS Fire Prevention &Building Code and/or manufacturer requirements.The applicant or owner agrees to comply with all applicable laws,ordinances,regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections have read and agree to the above: PRINT NAME:_Meghan Frazier signature VA pate:5/28/2020 Principle Structure Packet Revised February 2019, NATURALLIGHT,VENTILATION &EMERGENCY EGRESS CALCULATION SHEET Project Location: Primary Owner (s):Daniel and Meghan Frazier 12 Shore Acres Road,Cleverdale,Lake George,NY 12804 Habitable|Sq.Ft.|Required|Actual Required Actual Sq.ft. Rooms|of Light Light Ventilation|Ventilation|openingRoom|(8%ofrm.)|(sq.ft.)|(4%of room)(sq.ft.)forEgress0| uving 201 SF 16.08 SF 19.76 SF 8.04 SF >355F (2)17.5 SF 002 Bedroom 1|86SF 6.88 SF 25.92 SF 3.44 se 23.58 SF (2)73958 003 Bathroom|385F 3,04 SF 2.9656 15256 1.29 SF 175 SF 004 Bedroom 2 865F bead 25,92 SF 3.44 SF 23.58 SF (2)7.39 SF Principle Structure Packet Revised February 2019, WINDOW SCHEDULE CALCULATION SHEET Project Location:_12 Shore Acres Road,Cleverdale,Lake George,NY 12804 Primary Owner (s):Daniel and Meghan Frazier Habitable Rooms Window #iletter On PI:A c Db EDoorsnian00/001 Manufacturer Name Andersen ‘Andersen Andersen|Andersen|Andersen Model/Type Eseries Eseries E-Series E-series E-Series Unit/Block # Cell Size AWN2026 (2)CMT2640|AWN2020|AWN1616 HPO6468 Rough Openin::Wath Ps 9 2'-01/2"5'-01/2"2'-01/2"|1-6 1/2"-49/16" Sq.Ft.Vent 1.295F 21.0 SF 1.29 SF 0.59 SF 17.95 SF Sq.Ft.Egress/ Clear Opening N/A 739A,N/A N/A 17.95 SF Clear Opening- Width in inches 201/8"2113/16"201/8"<1s"(2)341/32" Clear Opening-, Height in inches <r 435/16"<24"<8"75.15/16" Special Hardware [@)TO HAVE REMOTEorinstructionsOPERATORSovate29292929 ido Principle Structure Packet Revised February 2019, Product Information Sheet <OUPONT» DuPont”Thermax™Sheathing Nonstructural,Glass-Fiber-Infused Rigid Polyiso Insulation FEATURES/BENEFITS. Description DuPont”Thermax”Sheathing"is 2 non-structural,rigid board insulation consisting ofa glass-fiber-infused polyisocyanurate foam core laminated between 10 mil smooth,reflective aluminum facers on both sides.The glass-fiber reinforcement contributes to improved fire performance and dimensional stability, Thermax”Sheathing also offers high,long-term thermal resistance,with facers that help prevent water and water vapor intrusion into the insulation foam allowing it to stabilize at a higher R-value*In the USA,Thermax”Sheathing can evenbeinstalledexposedtotheinteriorwithoutathermalbarrier.Used in conjunction with the appropriate joint closure system for the application,Thermax”Sheathing ~with its low perm rating ~can help to reduce moisture condensation within and behind the insulation, Ease of Installation Thermax”Sheathing: Eliminates the extra step of installing a membrane or building wrap Can be installed exposed to the interior without a thermal barrier (USA only) Contains UV-stable technology ~can remain uncovered up to six months, Reduces the potential for condensation within the wall, assembly Is lightweight -easy to cut,handle and install Sizes,R-values and edge treatment options for Thermax™ Sheathing can be found in Table 1.Contact your local sales representative for additional sizes TABLE 1:Sizes",R-Values And Edge Treatments For Thermax”Sheathing Nomint Board Thickness fn)‘Trermal Properties us canade is tom)vale Rs 030 :2 ose os :50 oss 1 :65 14 5 -98 in 15 »1 ve 2 st Bo 29 25 a 18 27a 3 5 we 3s as 20 aa 35 4 on 240 an an 8 2s 409 Boar Sze Avaidity kage Treatment usira Canada nm) axa ‘2202440 Square Edge axa "220 x 2400 Sauare Fdge 4x8 "220x2440 Squaretoea832040SauareEgeShilap ang wa «2040 ‘Savor Ege shilap axa 77547440 ‘Square Ege Shipp axe “a2 x 2440 ‘Sauore Edge,shiplap 4x8 ara 2240 ‘Sauare Foge,Shilap 4x8 "a2e x40 ‘Sauare Foge,Shilap ag “w2942040,‘Sauare Ege Shilap axe 1230x2440 ‘Sauae Edge Shilap tact your Por sale for formation at afer aus aa ote ae an ead tera earnest al racic ena enae008rmarsauseshsanneRateoweterpraucAvansbaron,Rake oh rr posts ewes Ree 2 Sustainable Solutions Thermax”Sheathing is manufactured from 100%renewable power and has a zero ozone depleting potential.The use of Thermax™ Sheathing helps reduce the carbon footprint of commercial buildings and can contribute to LEED Credits. PROPERTIES DuPont”Thermax”Sheathing exhibits physical properties as indicated in Table 2 when tested as represented.Reviewallinstructionsand(Material)Safety Data Sheet (M)SDS)before use.Please contact DuPont at 1-866-583-2583 whenadditionalguidanceisrequiredforwritingspecificationsthatincludethisproduct, TABLE 2:Physical Properties of Thermax”Sheathing Properes Compressive srenath ASTM Dian Fexural strength ‘ASTM C203 Thermal resitance ast ce Tensile strength |ASIM bI623 Dimensional stabity sim 226 ter absoration SIM C208 Wate vapor transmission ast2SusaceBumingCharacierisies,ASTM Ea for both foam core and ished product Fame spresd Spake Developed Yor coors erg mesures 310 peat celomaton yal whichever aca fat‘Giese araiy vais fornsor ay at mre ot mee eet hat ft aye pesecurdr sc recone TESTING Applicable Standards Thermax”Sheathing meets ASTM C1289 -Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board,Type |,Class 2 and CAN/ULC S704-1, Applicable standards include: 203 -Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation 209 Standard Test Methods for Cellulosic Fiber Insulating Board ASTM 02842 -Standard Test Method for Water Absorption Of Rigid Cellular Plastics C518 ~Standard Test Method for Steady:State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus 101621 -Standard Test Method for Compressive Properties of Rigid Cellular Plastics 02126 -Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging E96 ~Standard Test Method for Water Vapor Transmission of Materials 1623 -Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics Us toerasim c1285)Canadian (per CAN/ULC $708) Values Test Methoat values Bosimin ‘ast p12 oKPa 20 si min Asim C203 21542 min see table)ATM C58 Isee able) 2hpsi mia ‘ASTM 1623 WOKP=min 02%max asim 0726 07%max ormax STM o2aa2 asmax 0 perm ASTI E96 5 ng/Pasi a cannuccsing 30= i50 Notice Thermax”Sheathing complies with the following codes: ASTM E2178 Standard Test Method for Air Permeance of Building Materials -leakage rates less than 0,001 L/s/m?at a test pressure of 75 Pa, ASTM E283 Standard Test Method for Determining Rate of Ait Leakage through Exterior Windows,Curtain Walls,and Doors under specified Pressure differences across the specimen, Results were <0,02 Lis/m? ASTM £2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies ~no leakage ASTM E331 Standard Test Method for Water Penetration of Exterior Windows,Skylights,Doors,and Curtain Walls by Uniform Static Air Pressure Difference -no leakage 2018,2015,2072,2009 and 2006 international Residential Code IRC)Section 316 2018,2015,2012,2008 and 2006 International Building Code IBC)Section 2603 NBCC 9.2522 ICC-ES E5R-1659 CAN/ULC $704-03/11 CCMC listing 08433-L FM 4880 -Wall-Ceiling Construction Metal-Faced~Class 1 Fire Rated to Max.30'Exposure High,425"Thick,4’Wide, When Installed as Described in the Current Edition of FMRC Approval Guide.Contact Dupont Technical Support for most current FM 4880 attachment requirements. FM 4450 Approval Standard for Class 1 Insulated ~Steet Deck Roofs Thermax”products are covered under Underwriters Laboratories inc.(UL)File R5622 UL 1256 Fire Test of Roof Deck Constructions,Roof Deck Construction No.120 and No.123 Class A UL 723 (ASTM E84)Surface Burning Characteristics ofBuilding Materials The following designs are 1,2,3 or 4 hour wall rated assemblies as listed in the UL Fire Resistance Directory: U026,U326,U320,U3S4,U3S5,U424,U425,U46O,U902, us04,U905,U906,U907,V454,V4B2,V499 Fire Performance Evaluation of an Exterior Masonry Wall System Incorporating Thermax”Insulation Tested in Accordance With NFPA 285,2018,2015,2012,2009 and 2006 Editions (UBC 263,intermediate scale ~multistory testing) NFPA 285 compliant when installed as part of exterior wall assemblies in ICC-ES ESR-1659 or valid engineering judgement reports FMVSS No.302~Flammability of Interior Materials ~ Passenger Cars,Multipurpose Passenger Vehicles,Trucks and Buses (Docket No.3-3;Notice 4) Miami-Dade NOA 16-0222.01 Interior Insulation on CMU Block Contact your DuPont sales representative or local authorities for state and local building code requirements and related, acceptances. Warranty In the USA a 15 year thermal warranty is available, Visit building dupont.com/warranties or contact your DuPont representative for details. HANDLING WARNING:For Professional Use Only ~Read and follow the entire Handling section and the Safety Data Sheets (SDSs,formerly MSDSs or Material Safety Data Sheets)carefully before use.The information below is designed to protect the user and allow for safe use and handling of Thermax”Brand products.Follow all applicable federal,state,local and emplayer regulations. Precautionary Statements In Canadian construction,Thermax”Sheathing exposed to the interior must be covered with a thermal barrier. Thermax”Brand products should be used only in strict accordance with product application instructions. Thermax”Brand products,when used in a buildingcontainingcombustiblematerials,may contribute to the spread of fire For more information,consult MSDS and/or call DuPont at 1-866-583-2583, Disposal Dispose of any residual Thermax”Brand product,coated debris, oF solvent in accordance with applicable federal,state,and local government regulations. OUPONT» For more information visit thermaxwallsystem.com or call 1-866-583-2583 ONCE Nord fom ay ptt owed by OuPontor aes abe nerd.eave us condense pads ane may ile om aan onthe aay coger ten,{ somes esporsbiefar aeterinng wher bets sae rnatonieths dames gpm"Cnters ea fren asters we".a epee38Ineoratancewahspiceownowergovernorenacmentsnerassnnstatuayratoesaanaresnd"sreaae nal Gash whe batsorsendTheamymademaynarabeepoavedfoseacousefeesOurssusfaaseabythfrat.tr docar trocar urate of OME‘rea a DuPore eg eat sling te oa oar’en hare urea res NO HOMES WARRANTIES Ae GEN EXEST FOR ANY BEPLEABLE WRITTEN WARGANTES PLLALLY PROED BY GuPONT AL MUD WARRANTIES NLUONG THOSE OF MERCHANCABLIT AND PINES FOR A PARTCLAA PURPOSE ARE EXORESSY EXEIUDED TbeassesSirsisastheuseberaterBuyersecientsy2amingeatUranoeageraaliyotasalbeseestyeetehepensepreoeiateasFluestyadherearyecommercereeceaeseOPSectPedcsUSKLCotstesofaabywinesperaneataseatTelormatonerenotnceforeyronetessuralcaepbsoYheessnswhoGohlfheSlathepadresomaloarMaer auTon icp combustible Prater ih eat sure Arte breathe are may be requ as spced he poeple cage Fr or iformaton const(ater Sate aa See DSL al DuPont re 585255 cnt:Yue bung specoranemeryency,ct Y3696954400 nD US oH 33937 #Caac Walon:eam inston des not canste a wor wale surface 0 guy 2319 promedtBulnanorconsractonpracticesures9bulingmatercoufifemostntheott ar mod amaton No mater spp ning OvPo cane aschatdwtdevonsoesteDurned.on loge an a cera ade mae netic wthortSunesaesburoneohamgutewesahamedBSDOuro So 02meennaes cor Generated by REScheck-Web Software Compliance Certificate Project Frazier Bunk House Energy Code:2018 1ECC Location Lake George,New York Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:498 ft2 REVIE\ Glazing Area 21% Climate Zone:6 (7377 HDD)ENERGY CODE C JANCE Permit Date: Permit Number: Construction Site:Owner/Agent:Designer/Contractor: 12 Shore Acres Phinney Design Group Queensbury,New York 12804 142 Grand Ave Saratoga Springs,New York 12866SeeesCompliance:10.6%Better Than Code Maximum UR:123 Your UA;120 The X Bete or Were Than Cade nex elects now seo complance the house is based on coe rade les. GOES NOT prove an estate enegy use”cst elative ts minmumcodehomeEnvelopeAssembliesAeSeGeereCEILING:Cathedral Ceiing (no atti)‘oe 530~—«00 O08 WALL:Wood Frame.26 oc oon 24080003827 DOORS:Glass Door (over 50%lain 1o8 0203 NDOWS:Wood Frame 86 025025 FLOOR;Solid Concrete or Masonry a0 00170 ose9Wallheight:4.5° Depth below grade:4.5" Insulation depth:4.5 Compliance Statement:The proposed building design described here is consistent with the building plans,specifications, Calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC reqi REScheck Version :REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Michael R.Phinney,AIA -Architect 6/19/2020 Name-Tite Signature Date Project Title:Frazier Bunk House Report date:06/19/20 Data filename:Page 1 of 9 REScheck Software Version :REScheck-Web Inspection Checklist Energy Code:2018 IECC Requirement:.0%were addressed directly in the REScheck software Text in the "Comments/Assumptions"column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented,or that an exception is being claimed.Where compliance is itemized in a separate table,a reference to that table is provided. approved bythe code official. Section f°"|pre-inspection/Plan Review std varied|complies?|Comments/Assumptions requ 103.1,Construction drawings and Ocomplies 103.2 documentation demonstrate ‘Oboes Not PRID Shergy code compliance forthe @ building envelope.Thermal CINot Observable envelope represented on ONot Applicable enstractor documenss, 103.1,Construction drawings and complies 103.2,documentation demonstrate ‘OdoesNotéc37°energy code complancefrTrash:guts and mechanical systems Go obserabe Systems serving multiple INot Applicable Gweling an mustdemonstrateompllncewntheIECe Commercal rovsns —: BGI Heating and cooing equipment &Heating Heating,Cheops403.7 sized per ACCA Manual S based=Btu/hr_Btu/hr_Odoes Not I[PR2P on oads calculated per ACCA Coating Cooling:notObsalleservable@ManualJorothermethodsfeataorOotApplicable Additional Comments/Assumptions: T]High impact im Impact (Tier 2)3 [Low impact (Tier 3) Project Title:Frazier Bunk House Data filename: Report date:06/19/20 Page 2 of 9 6 30 €aed Oz/61/90_:@1ep uodey aweuayeedsno}yung Jeize14 :apLL alld,(tes) edwin] e|(eeu)pedw wnipaw]Z|(tau)aseduy youu]t uonduinssy/sjuowwo jeuoRIPPY aiqeanddy IONE) igqensasqo NT)6 20N s00q0)‘pajieisu sjonuo>ztoalse1dwooryuwaysksGupjaura3!pue mous”6EOH aigeouddy jong) aige “2pe16 mojoq ‘u!9 o wn}eAs0540 ONC]e spuete pue uoneinsuy 20N 3200)souaxe pasodxe yaiaid cel TtOa] s91}duo3Q)Tz E0E aj@e>uddv30Ng) sraenresa0 30NC)‘ yom so dor wousoussonyen.oj oye YPN S800)40 eungo adap vonejnsui {9031 soyqussy adojonuj a4)908 ___saiidwoaC)uy UY __temavauieseq pauonpu0y 6'z'z00| aigesuddv aon) aigeniasao 30NC)‘suonanasul s saunyejnuew e 30N s20qq)“ad pajfeysul uonemnsu!(S04) se1}dwooe)wemauaweseg peuorpuey _'Z-e0E| 9u07 s1eUHID Ul suone29]punyulienpoursagence30NYON“uoRDadsul uoRe INSU agen Supnp ind00 oy peauhewaens954010NC)—4 voneayuon ‘posn sj uoneinsuy sonjeninj jae.YPN SOC)a "W joyaqu asaum “anjer-y uonetnsul fy] soyquossy aden}a4)003 __saiidwoaC)x Wem aueweseq pauorpues —_r't'zor| Frese (ane ay onen enen &suopdunssy/sywowwo,|zs0ntdwor|payrnl es|poyrentueig| UoRPedSUI UoREPUNod seaionJ lrraming /Rough-in inspection]Plans Verified |Fleld Verified |Compas?!|Commenta/Aseumptonsenoa'402.1.1,Glazing U-actor (area-weighted U-u ‘complies ‘See the Envelope Assemblies 4023.1,average)—Clooee Not able forvalues, i023.(NorObservableonNotApplicable 3 303.1.3 U-factors of fenestration products complies |( FR4]'—_are determined in accordance ‘doesNotitheNERCtestprovedo@(NotObservableeatenthesecaea“Onot Applicable .| 402.4.1.1 Air barrier and thermal barrier Cicomplies FR23}installed per manufacturer's ‘Oboes Not e sstructions,( CNot Observable Not Applicable 7| 402.4.3 Fenestration that is not site built complies[ FR20}is listed and labeled as meeting OboesNotseiDnAeSA1OUnS©‘ or has infiltration rates per NFRC (QNot Observable 400 that do not exceed code Not Applicableinnsceedcou402.45 C-rated recessed lighting fixtures.complies[ FRI6)sealed at housing/interior finish ‘Odoes Not andlabeled to neat 320 cfm Calor Obserabe i. Oot Applicable 403.3.1 Supply and return ducts in attics complies FRIZP insulated R-8 where duct is OboesNotweicoinume=FT ar Cine Observabe return ducts in other portions of ‘ONotApplicabletreuisingmed6forderShesandeeThchesGeenaa}403,3.2 Ducts,air handlers and filter Ucomplies FR13}*boxes are sealed with OdoesNotFincicesereopenwth° International Mechanical Code or (Not Observable International Residential Code,as inet Applicable applicable .[ 0335~auising cvs re not used as FRI5}>ducts or plenums, CNet Observable- Dnot Applicable 403.4 R-complies FR17P above 105 °F or chilled fluids Oboes Not CTE to 5 routed =peesNoe7CNetApplicable 403.4.1 Protection of insulation on HVAC complies FR24)piping.Oboes Not e (CiNotObservablenotApplicable 05553 tot waterpbes ae nauated .Comptes[ FRIBP=-=R-3.Oboes Not°[ Wer Observable Ener hoptiabie 403.6.Automatic or gravity dampers are complies FR19P installed on all outdoor air ‘OboesNotestessedeunausepiboeeotOotApplicable 1 High impact (Tier 1)[2 [Medium impact (Tier 2)[tow impact (Tier 3) Project Title:Frader Bunk House Report date:06719720 Data filename:Page 4 of 9 Additional Comments/Assumptions: 1 [High impact (Tier 1)[2 [Medium impact (Tier 2)[3 [Low Impact (Tier 3) Project Title:Frazier Bunk House Report date:06/19/20 Data filename:Page 5 of 9 Sedocatg|__tnatontneecin|Pang Yee|Fated|compen?|commentesumotion 303.1 All installed insulation is labeled complies I(IN13}?or the installed R-values ‘oes Not oe Provided.(CNet Observable ONot Applicable Wall insulation Revalue.if thisis@ Re Ccomplies See the Envelope Assembles mass wall with atleast %ofthe C]Wood (Wood Coes Not table for values. wall insulation on the wall Mass JotObservableSxterfor,the exterior Insulation ees aes Inet Obsarvabh Fequirement applies (FR10).INot Applicable 303.2 Wall insulation is installed per ;‘Cicomplies ING)manufacturer's instructions.dees Not NotObservableGotApplicable Additional Comments/Assumptions: High impact (Tier 1)[Medium impact (Tier 2)[3 [Low Impact (Tier 3 Project Title:Frazier Bunk House Report date:06/19/20 Data filename:Page 6 of 9 Final inspection Provisions|Plans Verified|Field Verified|Compiies?|Comments/Assumptions Ceiling insulation R-value.Re Re complies ‘See the Envelope Assemblies. D Wood (Wood Oboes Not tabte far valent, CO Steet D Steet (QNot Observable ONot Applicable 3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in tests,verification may need to occur during Framing Inspection, 303.1.1.1,Ceiling insulation installed per ‘Cicomplies ~ manufacturer's instructions.does Not[ F2i"Blown insulation marked every NotObservableNotapplicable 402.2.3 Vented attics with air permeable ‘Cicomplies Fi22?"insulation include baffle adjacent CdoesNattosoffitandeaveventsthatextendsoverinsulation.CINot Observable CNet Applicable 402.2.4 Attic access hatch and door complies IF13}*insulation =#R-value of the CdoesNotadjacentassembly.iCiNot Observable an _Not Applicable 402.4.1.2 Blower door test @ 50 Pa,<=5 ACHSO Cicomplies[ fN7}~achin Climate Zones 1-2,and Ciboes not 3 ach in Climate Zones 3-8 ‘ CnetObservableBotApplicable -- Ducts are pressure tested to eimvio0 efm/i00—CicompliesdetermineairleakagewithOboesNoteither:Rough-in test:Total leakage measured with a Not Observable pressure differential of 0.2 inch Oot Applicable 1.9.across the systemincludingthemanufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with 2 pressure differential of 0.1 inch Wg.across the entire system Including the manufacturersairhandlerenclosure.a -4 Duct tightness test result of eimvi00 efmii00—CiCompliesFla}cfra/100 R2 across the system or 7 Cdoes NatotObservableOotApplicable accessible manual controls 3.3.2.1 Ar handler leakage designated Cicompiies IFI24}°by manufacturer at <=2%of doesNotdesignairflow.NotObservableNotApplicable - 1403.1.1 Programmable thermostats ‘Cicomplies F19?”installed for control of primary CdoesNatheatingandcoolingsystemsand initially set by manufacturer to EIN Observable code specifications.{CiNet Applicable 403.1.2 Heatpump thermostat installed Cicomplies FI10}"on heat pumps.Cooes Nat Not Observable Not applicable 1403.5.1 Circulating service hot water complies[ fi1i}*systems have automatic oF does Nat iNetObservableNotApplicable High impact (Tier i)[2 [Medium impact(Tier 2)[3[Low impact Tier’) Project Title:Frazier Bunk House Data filename: Report date:06/19/20 Page 7 of 9 lans Verified|FieldVerifiedFinalInspectionProvisionseNeeel Complies?|Comments/Assumptions Al mechanical ventilation system Cicomplies fans not part of tested and isted CboesNatHVACequipmentmeetefficacy and airflow limits per Table CNet Observable Ra0R6.1.Not Appticabie 403.2 Hot water boilers supplying heat Cicomplies[ F126 through one-or two-pipe heating Coes Not systems have outdoorsetbackcontrotolowerboilerwater CINot Observable temperature based on outdoor Oot Applicable temperature. 1 Heated water circulation systems ‘complieshaveacirculationpump.The OdoesNotsystemreturnpipeisadedicated return pipe or a cold water supply fot Observable pipe.Gravity and thermos-Gnot Applicable Syphon circulation systemsarenotpresent.Controls for Circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off thepumpwhenwaterisincirculationloop iS at set-point temperature and no demand for hot water exists. 2 Electric heat trace systems ‘Cicompiies| comply with IEEE 515.1 oF UL Cees Not 515,Controls automatically adjust the energy input to the CINot Observable heat tracing to maintain the ONot Applicable desired water temperature in the Piping,—[ 4035.2 Demand recirculation water complies F130}?systems have controls that Cboes Not manage operation of the pump and limit the temperature of the Not Observable water entering the cold water Dnot Applicable piping to <~1042F 1403.54 Drain water heat recovery units Cicomplies I(FI31P tested in accordance with CSA ‘does Not pressireloss ofrain water heat Not Observable recovery units <3 psi for Not Applicable individual units connected to one or two showers.Potable water- Side pressure loss of drain water heat recovery units <2 psi for individual units connected to three or more showers 404.1 90%or more of permanent Cicomplies Fle}!fixtures have high efficacy lamps.Cldoes Not Not Observable Not Appi 1404.1 Fuel gas lighting systems havecompliesIFi23°no continuous pilot light Cloves Not Not observable CiNot Applicable 1401.3 Compliance certificate postedCicomplieserieCoesNot Not Observable ONot Applicable T]High impact (Tier 1)[2]ier 3) Project Title:Frazier Bunk House Report date:06/19/20 Data filename:Page 8 of 9 Sectionca.Fnatinepectonrovsions|Pans Yeates|Fits Ved|”comptes?|commentsiAssumptons 303.3.Manufacturer manuals forCicompliesliFaPmechanicalandwaterheatingOboesWotsystemshavebeenprovided.nor observable ONot Applicable Additional Comments/Assumptions: i [High impact (ier 1)__[2 [Medium impact(ier2)[3 Lowimpact ier3)| Project Title:Frazier Bunk House Report date:06/19/20 Data filename:Page 9 of 9 2018 IECC Energy Efficiency Certificate Above-Grade Wall Below-Grade Wall Floor Ceiling /Roof Ductwork (unconditioned spaces): PereaCescWindow0.29 Door 0.29PeeSreeHeatingSystem: Cooling System: Water Heate! Comments. ss101ManualSComplianceReportDannAvent2arsEntireHouseBy: Plan: 19401eecenceForfrazier 12 shore acres,queensbury,ny 12804 CeMineietienDesignConditions Outdoor design DB:85.0"Sensible gain’8717 _Btuh Entering coil DB:75.2°FOutdoordesignWB:71 Latent gain:4253 Btuh Entering coil WB:62.6°FIndoordesignDB:75,0°F Total gain:9970BuhIndoorRH:50%Estimated airflow:466 cim Manufacturer's Performance Data at Actual Design Conditions Equipment type:SplitACManufacturer’York Model:TCGF18S4153+FC18A3XC1++S1-1TVMAF1Actualairflow:577 cfm Sensible capacity Btuh 0%ofload0 Latent capacity 0 Btuh 0%ofloadTotalcapacity©Btuh 0%of load SHR:0% EeetensDesignConditions Outdoor design DB:-4.0°F Heat loss:34207 Btuh Entering coil DB:68.3°FIndoordesignDB:|70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type:Gas furnace Manufacturer:York Model:TMSVO40A10MP11Actualairflow:57 cfm Output capacity:38000 Btuh 111%of load Temp.rise:50 °F Meets are all requirements of ACCA Manual S. tH wrightsoft’ge suco vives 2017 17010 Rsu2sn6 Paget‘iscot ingewerhy\Docimentevekaserp Cale =Mu?Front Dour faces:N Form RPER 1—=ACCA.PORIVAGESSCime Sen (Re-cmsc Mice e ey)15 varosnaryis Te (ltr a ae oN tela) jueensburynyHederinormation Contractor:REQUIRED ATTACHMENTS ATTACHED Manual 11 Form (and supporting worksheets):Yes].No]Mechanical license:‘or MUTAE Form”(and supporting worksheets):Yes ]No F‘OEM performance data heating,cooling,blower):Yes []No [] Building plan #49101 ManualOFrictionRateWorksheetvesQNgDuctdistributionsketch: yesNoQHomeaddress(Street or Lott,Block,Subdivision):12 shore acres,Entire House esian Conditions Building Construction Information Winter Design Conditions But‘Sumer eiectare “ar Onenaor:Front Door faces NorthsesemperatratETaaeetDOR008NewtTeeats24207SuhNumberoberon2Canaonedtormex1024SummerDesignCondtionsRaberfosepont4Saaseopeoce6inoornperetreerWindowsraeaierres27gil5%RH ave sverharg depth on “iSeoieheetgaGoseSenigresreve"geLatentheatgain:1392 Btuh =e any Degen|Jwindow:Tl ett,sor?Bun Number ef syon 0eVNCOHeatingEquipmentDataCoolingEquipmentDataBlowerData eu Gastimace Equi SpA Heaingcim=577RPSteEOLYESHeatingcnsmMode!York Mee Yok Stale westue:0laH20TusvosoatounroorrasetssEMBseepangcuputcapac38900.Shun,_Teta cooing capacity 0uhRSEaaAAOODtn,Teacovingcanci,9auocesingunacapaciy.0)Bh Lalen coving copay 0 Bun Design airflow:577 clm Longest supply duet:on Duct MaterialsUsedEquipmentdesignESP:0 in H20.Longest return duct of “Trunk duet Total device pressure losses:0 int20ofAvailablestaticpressure(ASP):0 in H20 Branch duet Sheet metal StoneSeeaearee Contractor's printed name: Contractor's signature:Date: Home qualifies for MJTAE Form based on Abridged Edition Checklist AE wrightsoft™rips suteo Unvertl 2017 17.018 RSUaSIIE ProjectSummaryEntireHouse Job:19101 Date:Apr 24,2020 By: Plan:19101 Project Information LeesSaPOUanONestomeeeTTeT] For:frazier 12 shore acres,queensbury,ny 12804 Notes: Design Information Weather:Glens Falls AP,NY,US Winter Design Conditions Outside db 4oFInsidedb70°FDesignTD74°F Heating Summary Structure 32271BtuhDucts1936Btuh‘Central vent (0 cfm)0Btuhnone) Humidification 0BtuhPiping0BtuhEquipmentload34207Btuh Infiltration Method ‘ SimplifiedConstructionqualityerageFireplaces1(Average) HeatingColinArea(ft ‘“02Volume()81928192Airchanges/hour 1.20 0.50Equiv.AVF (cfm)164 68 Heating Equipment Summary Make YorkTradeYtORKModelTMSV040a10MP 11 Summer Design ConditionsouserSexigntooFaDalyraMBEByBesae#SnSensibleCoolingEquipmentLoadSizing Structure 8302Btuhws#8oeCentralvent(0 cfm)O Btuh( none) Blower 0Btuhseandactzersda:Rate/swing multiplier 0.90Equi‘sensible load 7845 Btuh Latent Cooling Equipment Load Si:ing Ducts 0BtuhCentralvent(0 cfm)0Btuh45ealttessasonEquirtotalload9098BtuhPOsEEBiCoolingEquipment Summary8CondTCGF18S41S3, AHRI ref4876522Efficiency96AFUEEfficiency 11.5 EER,14SEERana,SES EeeRetae 738BeTemperaturerise60Reasoning.17300BuhActualairflow577cfmActualairflowS77cfmAirflowfactor0.017 cfyBtun Air flow factor 0.066 cfv/BtuhStaticpressure0inH20Staticpressure‘0 inH20‘Space thermostat Load sensible heat ratio 0.87 Catton re ACOA tore al erent nT awa&“Ae werightsoft nn suteo inven 217 1.0:0x8uz58 Page1scotangewonny.Docamentsvenaserp Cale =M.7 Prom Door foes:N NN seoe1,000 wn14__:r 9 dru sacenoA\suuoog KavonaBver noD8\ sate SSENGRer92GE een amie goerugtean fe PAIL F FENUEH Jo SWOWOINDSI Te WAU OF YOO a PaNONIGe SUOREMOIED PPOPer|BPHHES|OF]PHP ; BoSsSo]FoSSSSp SaaS Rgr Tio! on]| sunsouxa vu 189) 303A ha oe endo eH staneoy someun woos e tem pesado bon tien sen b pau wn asnoy amuz yeaysyiom @f-3UBIy, Right-J®Worksheet19101EntireHouse‘Apr 24,2020 901 MANUAL J:7m Ed name oreRoos3]Lo ot ecm watTon5]Room arersire 10x 20"4]cairgs "const.option 0hheabecrecor|csr]nm ‘ara|tsss(euny|Aa ‘aeexeosure|[NO |i "| somes [afvaca]sal 10)Epos |B |‘ 3fetesnoje|rte |J}’| fi so of winaaws ant [a]an0|aoa]=|acgossxe"||3]=afear”fe of =q = 4 =]gl =| a|=|g =?of =|= 7|windows a|non veal o|ee|NEN |g °Soe ew ai]aosse'sw o}|Scan }og :| fox |g 3 efotersas|a[s000]eo]esl of 7a)se‘|}“op6s}td of93|3}og Q | ane alzes|6]vo]zal ens)val “es]2fercses||of "ofan of9fratarsferrrTfantom|g ot of tin?otal gt‘|i a?o]of om oy S]tofcates—|al reco]24!xa]ol asst as)ase!ala3@}"of atm)GS)a]Pg3of3}tn TT a|aaa|}of mm tim}ogfCia|‘nf |gFoe[aloo sel of nol veel od |( Sete wom [8 fo}vim og:|}of tm)glfgoer”gl i a ||gferedo}of um!=f |gtes)|Ce a a |‘2lwrnaien 2|eaz|a5]as]ono]ara)oamalavenationCc| 13 suet onenoea.orie12 t2a70)=tse extra ea of =tase reer 3]=Hsing retain o]==|Das oes 7a =15|Tas =13614 om‘ alin gore Pepe,xeeal17]suing Yon.Sae18 _=tas eter Sg ==tes ewer ===resto ===12]Sasa o =18|Tota RSH gamer ss6yeur 10 -2]Arona cm Caloulations approved by ACCA to meet all requirements of Manual J 7th Ed abana19008bsHEwrightsoft”iy cvs Univeral 2017 170.18 A5U25:6 omen)‘siscot angewertn/Documents eka rip Cale =Ma?Fron Ort VESTS UN fray 01 (oy)aoe gz aan ay9euageoneenppnowyeeeoyunapepapaanuesZNO2SDINOHDTTa 10s pra‘sued ue 10 fa 2 2-2 sms weg wonepUD spaatedprsopweesesaypuesposeaeaun3Sv2 tt sep ndeagAsousaa a (eec0-onss-99eenoeHLYFNEINTAe ,meneeng’-- es 2 SSRN 2030-66 WHHEROD0130-66 zonexa-66 7 ‘one epono poeds yBiy ww 98/09/02, aT.-4OrpveZ30-087N0 OL rm 430 OW/NO OZsueoroy-.imag |oui 4 yoxUoD eM Weur pue saw vaaMiad 1uIOd |} ange omc.oe pe ee ri oa Hoa‘ mg Svaw ssa}2030-66 Jo aBve spuatG Z £4 wy eau sms‘strom evn sea coreg — Sonrensenatehe‘aBue!aewrxosdde oy ‘vonenersul jo ase2 Z s Z ‘eispaungag aersnipe yan ysquoa pray 09 40 Ob "02 40)voneniuan paads usiY saren Ut ’-wonevedo uey paeds moy snonnyuey 22uL Inu DS/o¥/02 MIEDLGaIN SsaFaIM a -(WBtH/mo7)wonesedo uepondsme UORI@uUOD aly ¢sa;MU;LL |x saa ins ni ap c/oeoe wenn tases SNOLLAO WIINIL ‘SNOLIdO TOHLNO)Hivauaaan WL-66 ‘ eC muss )sesacsmese606UCUBhDOSvenaieasSeeSsweeatoonsitonBIEaSaTTIT) yuo pag ns2aet,fa patsy oer an sus sy epee) SNLLNNOW seas a spo oma a a.IBYSuara wont podsuydmsm9uesehanynogequouseyweesyxy‘Su3MOTS GN SYOLOW ues 0 Beapsoasea1swearmywangeymse0Notahaa,309 WONIWNTY OSLNALWd ‘3ALLINGNOD ATTYWUSHL Vivd ONIUIINISNI YOLVILLNAA ANSAQI93YL3HardT=) mVHEATRECOVERY VENTILATOR PERFORMANCE (HVI CERTIFIED) etSipp Arton|680) GraxSippArton|16709|TRA) onstiastsiton|ari |e540) on‘Watts /Low Speed 4 7 aweeSteamyuees:i”0 ‘S2 LBS (23.6 KG) sarees _o salen|emcwsuy ao 5S 56 LBS (25.4 KG)‘ Suite z e@riom agus 2 0 ove2xNOTE:[sagem rn20recomimandedforservicingunit.Round duct°eeracesalrse6in(152 mu)comets, ai iss oma Static Pressure nw)BS DIMENSIONS seaonacat 2 faa Fresh airt0 inside5oe.warpanryweos:pet tyiaawe;semicovet—site —————LIFEBREATH BFwaoeraiespemsTimer:Timer ary,69-95MAX(OL-O1-18) wuusitebreathcom TABLE MISH 3.Ut) conrnwous WHOLE HOUSE MECHANICAL VENT TON SYSTEM AEELOH ATE REQUIREMENTS yaa wit ise OF ROE 00m Reh ese{equere fot) Rirtow ia CFM 1,500 x 45 Bs 0 7,301 -3,000 45 60 a 16 73,001 -4,500 a 75 105 10 4,501 -6,000 B 90 120)BS soni 7.500 30 105 3 3 3750 its 2 1 ig Fork Taquare fot =0.0979 0,cbc at pr mite =0.0004719 rascewis73.20) INTERMITTENT WHOLE-HOUSE ‘ VENTILATION RATE|FACTORS"? gern|m me|me [lm I ot z i zwpresnsavomeonstbienesEEnsaio!teapot. rapewnsors Mi1507.4 Local exhaust rates.Local exhaust systems shall mumuw REQUIRED LOCAL EXHAUST RATES be designed wave te capacity to exhaust the minimum st ‘ONE:AND TWO-FABELY DWELLINGS be design ined in accordance wih Table MIS07-4 TieCaeies[Widataeeicne iativon TaeSarnael,|Rooms intermittent or 20 cfm conti Fort:"ei Foot pt mite =00004719 a 4 eoCEFoCFM Soo Sort =HSCF Ufa Bed A 4 Q 50%< ENGINEERINGrucstructuralsolutions oeFILECOPY Structural Calculations for Frazier Bunkhouse Lateral Load Resisting System Per RCNYS Simplified Wall Bracing Provisions Prepared By: Scott Burlingame,P.E. Scot Bunge,PE.|900.8,146,Cito Prk,HY 12066 |T:S18-724.0733 |sotPabeninerngpli.com woo Featice -Kuocnouse _*Zooto.orENGINEERINGrucveerastructuralsolutions cALouLATED By__Sxe are, 7:518-724-0733 scotl@sbengineeringplle.com sone Quy Desir)Dam > erie ean)Wiese SPEEDS MS sagt SxPosuee CHECK Peovissuers oF REOZAL (Simmirien Wou Bracivts), Reor2s;Ceeumsearren Recmngue C70"ne Mins SEP IS Luo oe Ayecm Ramos Westie £3 OF 22 S We omiad ponervaLtt yh mintinun sWeantinG—Bre Riotrt ss Beaceds uWire’ TYPED +ots FULLY SHEATHER slo minimus BACH GAIT» REA:MULDTLE BE ACG Unis) See AMREAED Reo12 Nunrmee of Beacine unsivs TAME Lloe MA 7 Hor BKOnY Urs Rewieent Provives! Lone $e!2 We ow Swoer five.2 Bas ok DINE MRUON OF BP ACING UNTSt PRovition G) aKOQ© on Nateou Pavers: Nom Rev'h as PRovitiess AML MET in Ror ard we Provisions of Réooz.1z ave met FoR Carerar Force Pesismnce BILCO BASEMET VAT|ly yasBlyLSBy Numer of Bracing Unig Per 2601231AANA“ 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering PLLC Phone: (518 745- 7 ^�°tea - 75- 3 8 r9 July 9, 2021 �J JUL Town of Queensbury Building Department TOWN pF�UEENSIJURY Mr. Charlie Dyer BUILDING &c ODES 742 Bay Road Queensbury, NY 12804 0 2.146-?p ZU Re: Meghan & Daniel Frazier- 12 Shore Acres Rd -Cleverdale - Lake George New Home Construction Tax Map ID: 227.17-1-11. Dear Mr. Dyer, In accordance with our discussion, attached please find a record drawing for the septic.tanks and pump tank installation at the referenced parcel. The tanks consist of a 2000 and a 1000- gallon septic tank in-series for the main house, a 1000-gallon septic tank for the bunkhouse and a common 2000-gallon pump tank. As the absorption field has not yet been installed, the bunkhouse's 1000-gallon septic tank and 2000-gallon pump tank will be temporarily utilized as holding tanks in-series for the bunkhouse. A high-alarm has been installed in the pump tank. When the absorption field and forcemains have been installed, the holding tank usage will be discontinued. Please contact me with any questions that you may have, thank you for your assistance with the project. Best Regards, Lucas W.Dobie�P.E. Enclosures Cc: Meghan & Daniel Frazier John Clark- Builder Chris Crandall _ Crandall Excavating l