ResCheck s
Generated by REScheck-Web Software
Compliance Certificate
Project Colonial queensbury
Energy Code: 2018 IECC
Location: Warren County, New York REVIEWED FOR
Construction Type: Single-family ENERGY CODE.COMPLIANCE
Project Type: New Construction
Conditioned Floor Area: 1,480 ft2
Glazing Area 9%
Climate Zone: 6 (8499 HDD)
Permit Date: FILE COPY
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
Monsour Enterprises
Compliance:Passes using UA trade-off
Compliance: 1.7%Better Than Code Maximum UA: 172 Your UA: 169
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling:Raised or Energy Truss 860 49.0 0.0 0.020 17
Wall:Wood Frame, 16"o.c. 1,480 21.0 0.0 0.057 75
Door:Solid Door(under 50%glazing) 21 0.140 3
Door 1:Glass Door(over 50%glazing) 15 0.300 5
Window:Vinyl Frame 123 0.270 33
Basement:Solid Concrete or Masonry 860 0.0 15.0 0.042 36
Wall height:8.0'
Depth below grade:8.0'
Insulation depth:8.0'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 1 of 9
igREScheck Software Version : REScheck-Web
Inspection Checklist
Energy Code: 2018 IECC
Requirements: 61.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
&Req.ID
103.1, Construction drawings and '❑Complies
103.2 (documentation demonstrate 1 ['Does Not
[PR1]1 :energy code compliance for the 1
tt.Zj ;building envelope.Thermal :Not Observable
envelope represented on ❑Not Applicable
:construction documents.
i
103.1, :Construction drawings and '❑Complies Requirement will be met.
103.2, :documentation demonstrate ❑Does Not
403.7 :energy code compliance for
[PR3]1 ;lighting and mechanical systems.. ❑Not Observable
{ :Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
;compliance with the IECC
:Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ElComplies Requirement will be met.
403.7 :sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 Ion loads calculated per ACCA Cooling: Cooling: ['Not Not Observable
„ ) ;Manual i or other methods
;approved by the code official. Btu/hr Btu/hr ❑Not Applicable
i
1
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3.° Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 2 of 9
1
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
&Req.ID
•
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 :insulation R-value.Where interior R_ R- ❑Does Not table for values.
J ;insulation is used,verification :Not Observable
;may need to occur during
;Insulation Inspection.Not ❑Not Applicable
{required in warm-humid locations
{in Climate Zone 3.
303.2 ;Conditioned basement wall ❑Complies
[FO5]1 ;insulation installed per I }❑Does Not
r manufacturer's instructions.
t ❑Not Observable
i❑Not Applicable
402.2.9 ;Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[FO611 ;insulation depth of burial or ❑Does Not table for values.
`jj :distance from top of wall. ❑Not Observable
❑Not Applicable
303.2.1 ;A protective covering is installed t j❑Complies
[FO1l]2 to protect exposed exterior '❑Does Not
'insulation and extends a ❑Not Observable
minimum of 6 in.below grade.
i . ❑Not Applicable
403.9 ;Snow-and ice-melting system '❑Complies Requirement will be met.
[FO12]2 ;controls installed. i❑Does Not
;fit' ! . i❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies
-
402.3.4 ❑Does Not table for values.
[FR1]1
❑Not Observable
J ❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 ❑Not Observable
[FR2]1 ❑Not Applicable
303.1.3 U-factors of fenestration products ;❑Complies
[FR4]1 :are determined in accordance ❑Does Not
;with the NFRC test procedure or ry❑Not Observable
;taken from the default table. ❑Not Applicable
402�Air barrier and thermal barrier i 11=IComplies
[FR23]1 installed per manufacturer's ❑Does Not
,instructions.
, 1❑Not Observable
ENot Applicable
402.4.3 ;Fenestration that is not site built ❑Complies
[FR20]1 its listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC:or Observable
;400 that do,not exceed code ,ONot Applicable
;limits.
402.4.5 i IC-rated recessed lighting fixtures #❑Complies
[FR16]2 !sealed at housing/interior finish ` "❑Does Not
,and labeled to indicate 52.0.cfm ;❑Not Observable
leakage at 75 Pa. 31=INot Applicable
403.3.1 ;Supply and return ducts in attics i ❑Complies Exception:Ducts located
[FR12]1 , ;insulated>= R-8 where duct is 1❑Does Not completely inside the
>=3 inches in diameter and>= building envelope.
U [Not Observable
R-6 where<3 inches.Supply and
;return ducts in other portions of • 1ENotApplicable
;the building insulated>=R-6 for
diameter>=3 inches and R-4.2
;for< 3 inches in diameter. ,
403.3.2 ;Ducts,air handlers and filter i 11=IComplies Requirement will be met.
[FR1311 :boxes are sealed with iDDoes Not
, ;joints/seams compliant with Observable
International Mechanical Code or
;International Residential Code,as l 1=INot Applicable
applicable. 1 - i
403 3.5 Building cavities are not used as 11=IComplies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
;,',> ° ) t;❑Not Observable
i 31=INot Applicable
403.4 ;HVAC piping conveying fluids R- R- ❑Complies Requirement will be met.
[FR17]2 ;above 105°F or chilled fluids ❑Does Not
below 55°F are insulated to>_R- ❑Not Observable
I ❑Not Applicable
403.4.1 ;Protection of insulation on HVAC l ❑Complies Requirement will be met.
[FR24]1 piping. ❑Does Not
!.J ❑Not Observable
I I ❑Not Applicable
403.5.3 ;Hot water pipes are insulated to R- R- EComplies Exception: Requirement is
[FR18]2 I>_R-3. ❑Does Not not applicable.
J ; :Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 4 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
&Req.ID •
403.6 ;Automatic or gravity dampers are ❑Complies
[FR19)2 !installed on all outdoor air ,❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:.
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 5 of 9
z
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
&Req.ID
303.1 All installed insulation is labeled `❑Complies
[IN13]2 ror the installed R-values - ❑Does Not
U provided.
❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least Y:of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 !wall insulation on the wall ❑ Mass ❑ Mass :Not Observable
[IN3]1 ;exterior,the exterior insulation
requirement applies(FR10). III Steel El Steel :Not Applicable
r
303.2 ;Wall-insulation is installed per ❑Complies
[INC' manufacturer's instructions. - ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) "°3. Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: - Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1, 'Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ODoes Not table for values.
402.2,2, ❑ Steel ❑ Steel ❑Not Observable
402.2.E IFI1]1 ❑Not Applicable
!
303.1.1.1,;Ceiling insulation installed per i0Complies
303.2 :manufacturer's instructions. ODoes Not
[FI2]1 !Blown insulation marked every
300 ft2. Not Observable
❑Not Applicable
402.2.3 ;Vented attics with air permeable ❑Complies
[F122]2 !insulation include baffle adjacent ODoes Not
!to soffit and eave vents that
;extends over insulation. [Not Observable
i 10Not Applicable
402.2.4 ;Attic access hatch and door R- R- ❑Complies
[FI3]1 :insulation>_R-value of the ❑Does Not
jadjacent assembly. ['Not Observable
❑Not Applicable
402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies
[FI17]1 lath in Climate Zones 1-2,and ❑Does Not
-
!<=3 ach in Climate Zones 3-8. ❑Not Observable
ONot Applicable
403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception:All ducts and air
[FI27]1 !determine air leakage with ft2 ft2 ❑Does Not handlers are located within
either: Rough-in test:Total conditioned space.
;leakage measured with a
!pressure differential of 0.1 inch :Not Applicable
lw.g.across the system including
;the manufacturer's air handler
;enclosure if installed at time of
;test.Postconstruction test:Total
;leakage measured with a
;pressure differential of 0.1 inch
w.g.across the entire system
!including the manufacturer's air
;handler enclosure.
403.3.4 ;Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception: Requirement is
[Fl4]1 !cfm/100 ft2 across the system or ft2 ft2 ODoes Not not applicable.
!<=3 cfm/100 ft2 without air ['Not Observable
;handler @ 25.Pa.For rough-in
!tests,verification may need to ❑Not Applicable
:occur during Framing Inspection.
403.3.2.1 ;Air handler leakage designated ❑Complies . Exception: Requirement is
[FI24]1 :by manufacturer at<=2%of ❑Does Not not applicable.
!design airflow. I
?❑Not Observable
i❑Not Applicable
403.1.1 !Programmable thermostats {❑Complies Requirement will be met.
[FI9]2 ;installed
"for control of primary IODoes Not
;heating and cooling systems and
;initially set by manufacturer to ❑Not Observable
;code specifications. ❑Not Applicable
1
403.1.2 ;Heat pump thermostat installed #❑Complies Exception: Requirement is
[FI10]2 !on heat pumps. ODoes Not not applicable.
❑Not Observable
I ❑Not Applicable
403.5.1 ;Circulating service hot water ❑Complies Exception: Requirement is
[FI11]2 lsyster'ns:have automatic or ODoes Not not applicable.
!accessible manual controls.
❑Not Observable
,I]Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) '3 Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 7 of 9
f C
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
403.6.1 ;All mechanical ventilation system ❑Complies Exception: Requirement is
[F125]2 :fans not part of tested and listed ElDoes Not not applicable.
I HVAC equipment meet efficacy
and air flow limits per Table Not Observable
'R403.6.1. i❑Not Applicable
403.2 :Hot water boilers supplying heat 1❑Complies Exception:Requirement is
[F126]2 ;through one-or two-pipe heating ❑Does Not not applicable.
:systems have outdoor setback ❑Not Observable
control to lower boiler water
;temperature based on outdoor ❑Not Applicable
'temperature.
403.5.1.1 i Heated water circulation systems ❑Complies Exception:Requirement is
[FI28]2 Ihave a circulation pump.The ❑Does Not not applicable.
;system return pipe is a dedicated ❑Not Observable
i return pipe or a cold water supply
;pipe.Gravity and thermos- ❑Not Applicable
isyphon circulation systems are
;not present.Controls for
;circulating hot water system
1 pumps start the pump with signal
(for hot water demand within the
;occupancy.Controls
:automatically turn off the pump
:when water is in circulation loop 3
is at set-point temperature and
;no demand for hot water exists.
403.5.1.2 ;Electric heat trace systems ;❑Complies Exception: Requirement is
[FI29]2 (comply with IEEE 515.1 or UL t+❑Does Not not applicable.
1515.Controls automatically tSt❑Not Observable
adjust the energy input to the 3❑Not Applicable
;heat tracing to maintain the pp
3desired water temperature in the
piping. i
403.5.2 ;Demand recirculation water ❑Complies Exception: Requirement is
[F130]2 ;systems have controls that ❑Does Not not applicable.
I manage operation of the pump
;and limit the temperature of the Not Observable
;water entering the cold water ❑Not Applicable
;piping to<= 104°F.
403.5.4 Drain water heat recovery units i❑Complies Exception: Requirement is
[FI31]2 :tested in accordance with CSA I❑Does Not not applicable.
1655.1.Potable water-side
{❑Not Observable
;pressure loss of drain water heat i❑NOt Applicable
;recovery units<3 psi for pP
:individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units <2 psi for
individual units connected to
;three or more showers.
404.1 190%or more of permanent 3❑Complies Requirement will be met.
[Fie ;fixtures have high efficacy lamps. )❑Does Not
3❑Not Observable
❑Not Applicable
404.11 IFuel gas lighting systems have ❑Complies Requirement will be met.
[F123]3. ino continuous pilot light. sr' Not
❑Not Observable
I ❑Not Applicable
401.3 ;Compliance certificate posted. }❑Complies
[FI7]2 1 3❑Does Not
❑Not Observable
, ❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3. Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 8 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
303.3 'Manufacturer manuals for ❑Complies Requirement will be met.
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
,❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Colonial queensbury Report date: 06/08/20
Data filename: Page 9 of 9
2018 IECC Energy
III IN
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 15.00
Floor 0.00
Ceiling/Roof 49.00
Ductwork(unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.27
Door 0.14
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments