PTI-001908-2019 05312019INSPECTION WORKSHEET (PTI-001908-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:PT-0193-2019Case Module:Permit
Inspection Date:Fri May 31, 2019Inspection Status:Failed
Inspector:John O'BrienInspection Type:Property Transfer Inspections
Job Address:53 ASSEMBLY POINT RDParcel Number:239.12-2-16
Lake George, NY 12845
Contact TypeCompany NameName
Proposed OwnerBosy, William
Primary OwnerLANDRY, LORETTA
ContractorIBS Septic
Checklist ItemPassedComments
WeatherYESCloudy
Temperature (Fahrenheit)YES58
Septic tank (include # of tanks)YES1 low profile concrete septic tank
Depth below grade to top of tankYES6"-12"
Inlet baffleNONo baffle
Number of tank compartmentsYES1 compartment
Capacity in gallonsNO300 +/-
Dosing or pump tankYESSmall concrete pump pit.
May 31, 2019Page (1)
INSPECTION WORKSHEET (PTI-001908-2019)
Checklist ItemPassedComments
Ejector or grinder pumpYESZoeller sewage pump
Does the pump(s) appear to be operatingYESThe pump works but needs to plug into a waterproof ground
properly?fault receptacle.
Is there a high water alarm?NONo alarm system
Are there any obvious electrical shortcomings? -NONo ground fault receptacle to plug pump into.
NOTE: ToQ Code Enforcement Officer is not a
certified electrical inspector
D-box materialYESConcrete
Outflow line invert above leach line invert(s)?YESNo
Evidence of liquid above outlet inverts?YESNo
Cracked, corroded or deformed?NONeeds to be replaced cracked and eroded.
Absorption fieldNOThe absorption field is near failure. Of the 3 existing leach
lines only one is working.
The absorption field needs to be replaced due to not
functioning properly.
System appears to have functioned adequatelyNOThe absorption field is near failure. Of the 3 existing leach
lines only one is working.
The absorption field needs to be replaced due to not
functioning properly.
System/components indicate unacceptableNO
System appears undersized/undersizedNO
components
May 31, 2019Page (2)
INSPECTION WORKSHEET (PTI-001908-2019)
Checklist ItemPassedComments
Recommend upgrade/expand/replace 1+NO6/1/19 The existing septic system is in failure due to the
componentsexisting absorption field not functioning properly.
O'Brien, John (Inspector)
May 31, 2019Page (3)