Loading...
ResCheck , -: REScheck Software Version 4.6.4 1 / '' Compliance Certificate .4-": cn CV, co v" N Project ROBERT SEAVEY c Energy Code: 2015 IECC ) Location: Lake George, New York f Construction Type: Single-family D N Project Type: New Construction y N a)Conditioned Floor Area: 2,040 ft2 JUN 2 2 20# Q Glazing Area 24% a Q �' Climate Zone: 6 (7377 HDD) TOWN OF QUEENSBURY eV 'l3 CZ Permit Date: BUILDINGCODES 1 p = Lcz L Permit Number: t 0 N Construction Site: Owner/Agent: Designer/Contractor d ..... c Hall Road Robert Seavey G. Peter Jensen CO Z Queensbur, NY 12804 Hall Road 17 West Road (NI (/) Cr) Queensbury, NY 12804 South Glens falls, NY 12803 (518) 798-3859 - � z �' ' ..:.,.' � ' ':..; � - .x. ` a;ak��:ai�`"�rao' � a a aga�� aia3 �rr �< 4�r���'� a Via %�agng:ta s����� .° 'u�. S `���F R� mk'i Compliance: 1.8%Better Than Code Maximum UA: 271 Your UA: 266 , The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies _--,�-w-:z.-.-,m .w'=., •^-tr-a� .^;^z .7,7 c�,., --- 4-,,..� - - "a•Z,..m:»vm ...r^ - --"':,v,+r7.. - .g:-.` d.r .-,-C'� r. J�c nt;;�;'.�:"i -.—�,-- "_".":fir,"-^- ,'C` "„t`-_ - - ,i"u,, .c. yM"ti+:�1 yU.-' s ueti�.� ..«�l..a ,.{>. r��� e`i' ''+`2T ,�2• -� `s ,:r0' �r�e ;y. ,: , j��'•f r:Vizr.,,:t�i,,4-g<:,~t•i.:e"�':,-- , :''s A:,:,u•,v 'r• : : s:..�f<. ��'� �,. '"'S• ak4 `' �i�� �� .'r rft55.x xr'"�j-• ='d'`i�'�'��Y�e�`"Flt�rv.rt"� �^, .,. �,, t*-�'���T�1,- .u�k' "�� .� : a -, x�z+�t`'�i�,f-! i ' a r ,. Y _ - � ri e„�r' a ' �r xn�`�'+>� 3, t 4:'� mar . � 1 ,.dr I 9 T 1 � t, r+ e'�' i,...[ 1 m Ceiling 1: Raised or Energy Truss 1.020 38.0 0.0 0.025 26 Wall 1:Wood Frame, 16"o.c. 1,491 21.0 0.0 0.057 62 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 37 0.300 11 Door 1: Solid 40 0.200 8 Door 2: Glass 320 0.300 96 Basement Wall 1: Solid Concrete or Masonry 560 13.0 6.0 0.043 24 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Floor 1: Slab-On-Grade:Unheated 58 11.0 0.677 39 Insulation depth: 6.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. G. PETER JENSEN -f.F .. riiihAName-Title 17 WEST ROAD gna.,, Da SOUTH GLENS FALLS K�PE Q 4 Rc Project Notes: NEW YORK 12803 N."' �o Singlle Family Residence (518)798-3859 �0 lER JF,� tg -I, * if Project Title: ROBERT SEAVEY I ., Report date: 06/11/18 • Data filename: C:\Users\Peter\Documents\REScheck ea -• .0 Page 1 of 9 3 ,, ,, :�,,�� R.EScheek SoftwareVersion 4 6 4 ,` Inspection Checklist r.:,.,...v,.,_.•. Energy Code: 2015 DECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Complies? Comments/Assumptions &Reci.ID __ Value Value . 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the • ❑Not Observable building envelope.Thermal envelope represented on . . ❑Not Applicable construction documents. - . 103.1, Construction drawings and • . - • ❑Complies 103.2, documentation demonstrate EDoes Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple . . ' ❑Not Applicable dwelling units must demonstrate . - compliance with the IECC ` Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seavey.rck Page 2 of 9 Section i ^ Plans Verified Field Verified # Foundation Inspection • Value • Value Complies?. Comments/Assumptions &Req.ID _I 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [Foil' LI Unheated ❑ Unheated Does Not table for values. _ ❑ Heated ❑ Heated ❑Not Observable . ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [FO3]' depth/length. Does Not table for values. ,,_f .DNot Observable ❑Not Applicable 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]' insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection.Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall . ❑Complies . [FO5]' insulation installed per .• ❑Does Not manufacturer's instructions. • ['Not Observable - . ❑Not Applicable 402.2.9 Conditioned basement wall ft ft DComplies See the Envelope Assemblies [F06]' insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable — 303.2.1 A protective covering is installed . ❑Complies [FO1ll2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in.below grade. ❑Not Observable . ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]z controls installed. - 10Does Not ONot Observable ❑Not Applicable Additional Comments/Assumptions: • ' i l High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seavey.rck Page 3 of 9 Section ( Mans Verified Field Verified # Framing I Rough-In Inspection Value Value Complies? Comments/Assumptions: &Req.ID _ 402.1.1, Door U-factor. U- U- DComplies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable —` ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- DComplies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, . 402.3.6, ['Not Observable 402.5 ❑Not Applicable [FR2]1 • 303.1.3 .U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable • ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier - DComplies [FR23]1 installed per manufacturers ❑Does Not instructions. • }' •❑Not Observable . ❑Not Applicable 402.4.3 Fenestration that is not site built .❑Complies [FR2O]1 is listed and labeled as meeting - • ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 . or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code - DNot Applicable _ limits. • • 402.4.5 IC-rated recessed lighting fixtures .DComplies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<_2.0 cfm leakage at 75 Pa. ❑Not Observable _ ❑Not Applicable 403.2.1 Supply and return ducts in attics • - DComplies [FR12]1 insulated>=R-8 where duct is • • • ' 2 ❑Does Not >=3 inches in diameter and>= • ' - . R-6 where<3 inches.Supply and DNot Observable return ducts in other portions of " V ❑Not Applicable the building insulated>= R-6 for • diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 'Building cavities are not used as • - ❑Complies [FR15]3 ducts or plenums. ❑Does Not -:' • . _ ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- DComplies [FR17]2 above 105°F or chilled fluids •❑Does Not J, below 55°F are insulated to>_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC - .DComplies [FR24]1 piping. ❑Does Not . ❑Not Observable _ ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- DComplies I[FR18]2 .>_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]z installed on all outdoor air . •❑Does Not intakes and exhausts. • ❑Not Observable - • ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seavey.rck Page 4 of 9 Additional Comments/Assumptions: 0 High Impact(Tier 1) 12 'Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seaveysck Page 5 of 9 , Section Plans Verified Field Verified ' &Re {p Insulation Inspection Value Value I Complies? Comments/Assumptions q• _ 303.1 All installed insulation is labeled • _' ❑Complies [IN13]2 -or the installed R-values • ❑Does Not :r provided. [Not Observable . - • DNot Applicable 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least lh of the Wood table for values. 402.2.E wall insulation on the wall ❑ ❑ Wood ❑Does Not Mass ❑ Mass [Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel '❑Not Applicable 303.2 Wall insulation is installed per ' ElComplies [IN4]1 manufacturer's instructions. ❑Does Not [Not Observable - .DNot Applicable 1 Additional Comments/Assumptions: • • 1 High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seavey.rck Page 6 of 9 Section _plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.lD . 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [Fll]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. • - •❑Does Not [FI2]1 Blown insulation marked every 300 ft2. - - :Not Observable . - ❑Not Applicable • 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent DDoes Not to soffit and eave vents that -extends over insulation. [(Not Observable • ❑Not Applicable J 402.2.4 Attic access hatch and door R- R- ❑Complies [FI3]1 insulation?_-R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= ❑Complies [FI17]1 ach in Climate Zones 1-2,and ❑Does Not • <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in ❑Not Observable tests,verification may need to Not Applicable occur during Framing Inspection. _ �403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]1 determine air leakage with ft2 . ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including . the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. _ 403.3.2.1 Air handler leakage designated -- '❑Complies [F124)1 by manufacturer at<=2%of ❑Does Not design air flow. - . ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats . ❑Complies [F19]2 installed for control of primary ❑Does Not heating and cooling systems and ❑Not Observable initially set by manufacturer to - - - - code specifications. .. • El Not Applicable 403.1.2 Heat pump thermostat installed • . , -❑Complies • [F110]2 -on heat pumps. . - . ❑Does Not [Not Observable - - • . ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [F111]2 • :systems have automatic or . - ❑Does Not accessible manual controls. ` - [Not Observable ❑Not Applicable 1 I High Impact(Tier 1) j 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) M Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seavey.rck Page 7 of 9 .,.. -: =-ham.,,.. ....: .. - V i Secti®n i • Plans Verified Field Verified } # Final Inspection Provisions n Value Value Complies?• Comments/Assumptions. I&Req.ID 403.6.1 All mechanical ventilation system - - ' •❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy - • and air flow limits. 'DNot Observable •ONot Applicable — 403.2 Hot water boilers supplying heat DComplies [F12612' through one-or two-pipe heating ❑Does Not systems have outdoor setback ' . control to lower boiler water • - - - , . ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. - 403.5.1.1 Heated water circulation systems DComplies [Ft2812 have a circulation pump.The .. -. . - ODoes Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply - . pipe.Gravity and thermos- [Not Applicable syphon circulation systems are not present.Controls for circulating hot water system •pumps start the pump with signal - - ,for hot water demand within the - • - - • occupancy.Controls automatically turn off the pump when water is in circulation loop '. _ - -. ' is at set-point temperature and - ' • •no demand for hot water exists. ' . . 403.5.1.2 Electric heat trace systems •. :DComplies [FI2912 comply with IEEE 515.1 or UL ❑Does Not • 515.Controls automatically - - -. adjust the energy input to the - ❑Not Observable •heat tracing to maintain the C7Not Applicable desired water temperature in the - piping. • , = 403.5.2 ,Water distribution systems that . . DComplies [FI30]2 . have recirculation pumps that ❑Does Not • •pump water from a heated water - • supply pipe back to the heated ❑Not Observable • water source through a cold . ' • ❑Not Applicable water supply pipe have a - demand recirculation water . system.Pumps have controls - that manage operation of the pump and limit the temperature •of the water entering the cold . • water piping to 104°F. • • . - • 403.5.4 Drain water heat recovery units ' . ' " - •OComplies [F131]2 tested in accordance with CSA . . . ' ..,'ODoes Not •B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units<3 psi for ❑Not Applicable individual units connected to one . or two showers.Potable water- . . side pressure loss of drain water heat recovery units<2 psi for - - :• individual units connected to - three or more showers. 404.1 75%of lamps in permanent - • -�ElComplies [Fl6]1 fixtures or 75%of permanent . . • ' ' . 'ClDoes Not fixtures have high efficacy lamps. •- • Does not apply to low-voltage ❑Not Observable lighting. • . -ElNot Applicable 404.1.1 Fuel gas lighting systems have 'DComplies [FI23]3 no continuous pilot light. - ' • - • ' DDoes Not riNot Observable - [Not Applicable 1 High Impact(Tier 1) j 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seavey.rck Page 8 of 9 Section# Final Inspection Provisions I?la m er f ied R Field Verified Complies? ( Comments/Assumptions e I 401.3 Compliance certificate posted. • OComplies [FI7]2 • -DDoes Not ❑Not Observable ❑Not Applicable 303,.3 Manufacturer manuals for :Does [Filemechanical and water heating ❑Does NotNot Observable systems have been provided. ❑ ❑Not Applicable l Additional Comments/Assumptions: • • IT High Impact(Tier 1) 2 i Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ROBERT SEAVEY Report date: 06/11/18 Data filename: C:\Users\Peter\Documents\REScheck\Seavey.rck Page 9 of 9