2005-472 Al°khakiTOWN OF QUE E NSB URY
742 Ba Road eensb NY 12804-5902 518 761-8201
Y ,Qu �Y, � )
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20050472 Date Issued: Friday, July 28, 2006
This is to certify that work requested to be done as shown by Permit Number P20050472
has been completed.
Tax Map Number: 523400-290-006-0001-067-000-0000
Location: 1114 RIDGE Rd
Owner. ALLISON WILSHERE
Applicant: ALLISON WILSHERE
This structure may be occupied as a:
Residential Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
Fom 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20050472 Application Number: A20050472
Tax Map No: 523400-290-006-0001-067-000-0000
Permission is hereby granted to: ALLISON WILSHERE
For property located at: 1114 RIDGE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: ALLISON WILSHERE Residential Alteration $10,000.00
1114 RIDGE Rd Total Value $10,000.00
QUEENSBURY, NY 12804-0000
Contractor or Builder's Name / Address Electrical Inspection Agency
A PLUS HOME IMPROVEMENT
9 WILLOW St
SOUTH GLENS FALLS, NY 12803-0000
Plans&Specifications
2005-472
750 SQ FT RESIDENTIAL ALTERATION TO INCLUDE A DORMER
$75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Sunday, July 15, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of ueensb F •' a/ Jul 15, 2005
SIGNED BY • for the Town of Queensbury.
Director of Building&Code Enforcement
Permit No. J00�_ `7 lo&
Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid -7 S.
742 Bay Road,Queensbury,NY 12804 Recreation Fee
Dave Hatin,Director codes®aueensburv.net
Phone: (518) 761-8256 FAX: (518) 745-4437
Principal Structure Building Permit Application
Application & Plans subiect to review before issuance of a valid permit for construction.
Instructions: A permit must be obtained before beginning construction. No inspections will be made until the
applicant has received a valid building permit. All applicants' spaces on this application must be completed and
must appear on the application form.
Applicant/Builder /9 4f Jus Jhm !a,110.1nv> ,v7• Owner: 11Koh ,),\C e(e-
Address: y t,�i'//0 v s T Address: 1� �►t 1 e_
Soh,rJ/ G /-<4, 1-4 PSv ° uee.�nshu N �g�
`I, l
Home Phone: 19 f-2 L f S Home Phone: S —
Email Address: Email Address:
Cell Phone: Cell Phone:
FAX Phone: FAX Phone:
Person responsible f supervision of work with respect to b ilding and codes compliance:
Name: dj4 C
Address: 9‘fi,`l�cv - k\ t.� '�1,cci Phone -�O i rr
C��� ��ot ��P
Location of proposed construc ion:r Lot No. Legal Address:
Tax Map Number: a q (97 Subdivision Name:
Estimated Cost of Construction:
to ooC) -REEF ICE
JUN ,, '6105
Proposed construction is for: $__Residential Use _Commercial Use
TOWN
Name of Business: BU1LDiN<. AND CODE
If proposed construction is an addition, what will use of new addition be?
New Addition Alteration Proposed Construction 1 Floor 2^d floor Other Total Proposed
structure (Occupancy Type) Sq.Ft. sq.ff. Sq.Ft. Square feet Height
Ft.&.in.
.4 Single-Family Dwelling -7 50 7.5 (D r.Q,7 E
Two-Family Dwelling
Townhouse
Multifamily Dwelling
Number of Units:
Office
Mercantile
Manufacturing
Other:
Attached Garage 1, 2, 3
Type of Heating System: Electric, Oil, Gas, Wood, Forced Hot Air, Baseboard, Other: t'>!s`s%:.
Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes No
Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review.
The Building and Codes Office will allow commencement of your proposed project only after
issuance of your permit.
Declaration: Please sign below after you have carefully read the statement:
To the best of my knowledge, the statements contained in the application, together with the plans and
specifications submitted, are a true and complete statement of all proposed work to be done on the described
premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the
proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner.
Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance
being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a
licensed surveyor,r, drawn to scale, showing actual location of all new construction.
Date: G/o� '/DS Applicant/Builder Signature:
The application of dated is hereby approved and
permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set
forth above.
Date: 1 t Authorized Signature:
L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04
-7) . 1oc, 1O \ \
Queensbury Building & Code Enforcement - Resl e tial Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depart: w� a pm
Date Inspection request received: 7 t 1 0(e Inspector's Initials: +
NAME: A44 PERMIT#:
LOCATION: �� f DATE:
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete 1,/
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall -i
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors s/main entrance 36 inches
Bathroom/Kitchen wat i ht
Safety glazing/Win in stairwells safety glazing
Interior Smoke De etors:
Every level: Every droom:
Outside every bedroom ar : ///
,/'�
Inter Connected: 4 Battery backup: '!/
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below_grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/a hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure •
Final Electrical t
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
Rough Plumbing / Insulation Inspection Repor,
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: 9.' S U am/pm Depart: a /pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 'cD/-
•
NAME: U31 I 11 PERMIT #:
LOCATION: / / ) 7 Ka INSPECT ON: 5
TYPE OF STRUCTURE:
Y N N/A I
Rough Plumbing / Nail Plates cl n13)k\
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
5 .I for 15 minutes
sulation / Residential Check/ Commercial Check ✓
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Rough Plumbing / Insulation Inspection Report ffi
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/p Depart: /pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
NAME: ' .Jt° \\ S rC PERMIT #: c 5,`1 a
LOCATION: ill 1 ( Rc INSPECT ON:
TYPE OF RUCTURE: V1
InrG�
Y _ N N/A QQG
ugh Plumbing / Nail Plates (�,,
4h)„,,O
Plumbing Vent / Vents in Place `�'t
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
V essu e Test
Drain / Vent
erA' ad
5 .S.I:fir 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
Insulation / Residential Check / Commercial Check
Proper Vent, Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p D art:3'AO am/
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: (ti � ~� Z PERMIT#:
LOCATION: ( �\C - &- INSPECT ON: / c�
TYPE OF STRUCTURE: f
1' N N/A COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in.or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire partition 1, 2, 3 hour
re wall 2, 3,4 hour
Firestopping�d
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: � PERMIT#: t
LOCATION: t� ��' -- INSPECT ON: S13
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Framing
Attic Access 22"x 30"minimum
Jack Studs/Headers L.L.3
Bracing/Bridging ��""
Joist hangers ,4,
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. - "° �e. —
Headroom 6 ft. 8 in.Stairwells 36 in.or more (- Q om,1'" L- —
Headroom 6 ft. 8 in. --1 e ( L
Notches/Holes/Bearing Walls C-t \ C
Metal Strapping for Notches Top Plate < y )]-z)
1 ''A(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center ()
Ice and water shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 'A inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Ry-N
Framing / Firestopping Inspection Report \-- .3 -
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: am/ epart: , am/p ,/ 4`J,
742 Bay Road, Queensbury, NY 12804 Inspector's Initial:
NAME: P\&i .)�1 _ PERMIT#:
(9 06— Li7;),*
LOCATION: \WyACii71.;,,g_ INSPECT ON: ', —r alp
TYPE OF STRUCTURE: 0`} A
1_v N/A COMMENT.
Fr ing ,r
Jack Studs/Headers
Bracing/Bridging W4 , ^`��b ,� 0 '1jPCI ,V'5(
Joist hangers
Jack Posts/Main Beams 1/6- �� p�k6 D 1k
Exterior sheeting nailed properly d
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
anchor Bolts 6 ft. or less on center
.//Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side % inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
4 11,(D
-
j
L.Li
JUN 2 e
L )''''\7 2 2o95
FILE COPY
- 5.-0" ,
TOWN OF OUEENSBURY
BOLDING & CIO ADDEPT __. ,
siLik:Lk- J-----
REVE.AN 0
(I E-1\Aci
7'-5" 8'-1" 8'4"
31'-0" if•-,.
.4_-.._,.,,,,• , i'.1
kl" rt)
? ,
,
1 t
1-- l- 'i,,,,.,,..
2. o
3 ec)..,..,).1... .--,..t.--, ,,,,,,0„,
a ,-- 2'-0" 2'-8"x 6,8"PD
2- 't cz.
13 ...
3'-8" `g '
2'-3/'-"8"
.•
'§I 02
o
_i
(r) 41
2 c.„
31'-0" ---)
__ „._.>
--,- --A, ei-ATZ., -,k \---;' k) ''., .tz,-: cil,t4i,44,\IC:::4-a)
- 4
R 6.1---2-, ,{9— t z )7 TZ ' --)A—i) \A/ t-Ni 14- 44A-KibiN" 4='-'
i,.... 71
z.."
41 1(..•,,L, (..: 1?-- F
..d.._04
....-:.,
CZ ,ci\A ---'
Too-C,',.s.s
4..//s,ie 7.'
/DOS �06,e14fI c._ 6r K [c SC..+ ,.,.fob_*)
4 G,y, Dec
�• e. P
__._- ..(1-1 - _.a..,..___., X(lr //i/,
R 0 'G Q .
7 G" o s S gfeCA,'
/- ' is . 1.1‹.t . __P,.. _____-_-_,.
'-K-a/ Fes. IT. A
0 ) i)rasu,'I"ho 1l1-441;.eld_w..
.s;A'fu5j ap 010-kb ex/s?'
z v
II
j, /� ili' -#/- 3 �Q oQYa�vChT
.
I 'it-3$ t.G G'41,' Isla 14
\ / ---'>;:4 — '- — ————---
JAL Tog,',,-
.,
:'-' l'6'/' f_.,e__j 5 7.___._.f.....)e,__a__e „,ys ir,,,..,
_\.
i i
Lowes Quote http://m2osrv.0998.Iowes.com/rn2o/lowesQuote.jsp?projectld=9914748
4.
Back to Quote
LOWE'S HOME CENTERS, INC. r
#64 l ,
it
251 QUAKER RD. L �,
QUEENSBURY,NY 12804 Ordeir
.......LCIWE
(518) 798-9050
Date: 06/10/2005
Project#: 101030168 Project Name: window
Customer Name: ALLISON WILSHERE
Customer Phone: (518) 798-3698
Customer Address: 1114 RIDGE RD
QUEENSBURY NY
12804
Line Item Product Code Unit
Frame Size Description Price Quantity Total Price
0001 Manufacturer: Pella Windows & Patio Doors
Frame Size= 2' 9" W x 4' Division: Millwork
5" H Product: Windows
RO Size= 2' 9 3/4" W x 4' Type: Double Hungs
5 3/4" H Manufacturer: Pella Windows & Patio Doors
Product Line: Pella Products
Product Configuration: Single Unit
Exterior Finish: Hassle-Free Aluminum Exterior
Frame Size Width: 2' 9"
Frame Size Height: 4' 5"
Rough Opening Width: 2' 9 3/4"
Rough Opening Height: 4' 5 3/4"
Sash Style: Even
Exterior Color: White
Seacoast Color: No
Interior Finish: Unfinished-ready for site finishing
Glazing: Energy Saving Low E Glass
(Recommended)
Tempered Glass: No
Hardware Color: Standard Champagne
Handle Hardware: No
Grille: 3/4" Traditional Wood Removable-
Unfinished
Lite Pattern: 3W2H
Fiberglass Insect Screen: Yes
Screen Type: Standard
Wall Depth: 6 9/16" Applied
Series / Profile: ProLine 450
Lead Time: 21 Days
Part Numbers:
PTDWEAS3353V D
PTDU3353MUN (1)
PTDW3353SCR(1) $261.01 3 $783.03
Project Total: $783.03
Salesperson: TORREY SCHUMARD(S0641TS2)
I oft (16/10/2005 10:43 AM
Lowes Quote http:/hn2osrv.0998.lowes.com/m2o/lowesQuote.jsp?projectld=9934748
Accepted Date: 06/10/2005
Print this Page
This Millwork Quote is valid until 6/16/2005. This is an estimate only. This estimate does not include tax or
delivery charges. Delivery of all materials contained in this estimate are subject to availability from the
manufacturer or supplier. All the above quantities, dimensions,specifications and accessories have been
verified and accepted. I understand that this order will be placed according to these specifications and is
non-refundable.
2 of 2 06/10/2005 10:43 AM
7n1' /rrtt? 2f
I'� `v .`' +. +c'4,y 7b�11w its: c r r ,. 'nc.>x . ,. ..,w,,,,,,,,-• ,J w,.__..
' t
fh zaF+ b�t r k�' �. Y i
J k T � � i u C r
"t� t x H k .: r , axa ti4t, x ' .. -
�' :i , :, f a ti`'�e a�y," i74, r - S'l5.f X*k° t ,x+4�,y.1,1 ,
�' Y'• h t , ,4 ."~�, ,'-, ,s,1J,' .m«^ -'k.. ',Y.r is J t' :} ,
'J, .L'•N S' `i -0.1,�,, �y��:;� AlY �N Y,{ .f N. .1 +„ fi' "YL'
t •tir"tu c ik7`,,1, �p e�, � h`i 1 y 4 :� as s ,t k:�''' ,
e Y 1p P 1 h y a',y� i .x. -`` i ^ �^ 4, �39-' d ti-'W •, — , . --,-,.- ::,--,-„,,,,„:: . - :'- -
0 ` �}
,. , . �. ..i,M1�.'}T l,, ;v� n ra ^r . ,, x k�xu,7Fv '�ya 'M`�'r:' #�c, r.�S, r e,
1 ST: 1 F" f t , 7f:6•.,d:F'•i .. Jr y�M.
RE E �1 f s „[","�iy 41':4 '�x,7, FY F. ¢ xa�ik t".p �^'+�rSyFf� '-,wrb 4 n dsr .i" �. ia.na'L Y Y. z h`' t
�6I fs 'art ,, t -? -� +, 'P 'y' >n��,.•,",�, x:, rr""'` ?.S 'ow, ''r't .s'. ,,, •�` ° .4a >,,,t
„'ems.' x.ts >, :-,.7;ot.a 1>r 4t';.c':i k41°',. ���,;. 'r,;y,A t .. i S5,
r
.�-• �. .a .. . .,� ..Po,�'.. ..,Y••,yhi• -,:.� -tr�: fi'kY�.'�+,rri'w �as. .,4 i§.1x"�k 'i>F ,s't „t r r� .��esz ',F;� ,a;:;'x,ti
,_. .,. : ..',`, :fix .,: .a 4 -ci'A* .� .#: `:' 1,r',,r g �� �s i.'ti".. >3 ],� K�t, � xt•,.b o�� 1„ Y�
Yfr ,.� .:,� , ,� - ,,in y �.Y o ,' ,',x'F'x '"'C MS ,i..yrY, a,"<ivt dr
, ;r '1 a • ;:Y is Y i. ^ .>« r r, ti :1x4?,, ", 71 zlz,i w's ':'r
�. Jt1 4+. , ,� + �.�' �,y .1,.. . � a �
,r 1
` rTOWN OF QES8URY a! .
1
J (// /gyp
+y{
.: ''FWD,:, L` .' f .""MYY..°" 11 t 4..- ., .. ...a.v�....,....rc..,,...,.»..,....n+«....,..«...,�� wr,..e..
Permit Number
Checked By/Date
CIGenerated by REScheck Package Generator
Compliance Certificate
Project Title: Upstairs Renovation
Energy Code: New York State Energy Conservation Construction Code
Location: Warren County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Window-to-Wall Ratio: 0.13
Heating Degree Days: 7635
Report Date:
Date of Plans:06/28/05
Project Information: Builder Information:
1114 Ridge Road Jeff Gargano
Jim Cabral
South Glens Falls, NY 12803
793-3698
Project Notes:
Compliance:Passes
Assembly Cavity R-Value Cont. R-Value Glazing or Door
U-Factor
Ceiling: 38.0 0.0
Wall: 21.0 0.0
Window: 0.320
Door: 0.350
Floor: 19.0 0.0
Furnace::82 AFUE
Statement of Compliance:The proposed building represented in this document is consistent with the building plans,specifications,
and other calculations submitted with this permit application.The proposed systems have been designed to meet the New York
State Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this
page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in
compliance with this Code.
, erne.� ire, t `7/c-os
er/ r Company Name Date
Page 1
411
Generated by REScheck Package Generator
REScheck Inspection Checklist
Project Title: Upstairs Renovation
Ceilings:
❑ Ceiling:,R-38.0 cavity insulation
Comments:Increasing from R-13
Above-Grade Walls:
❑ Wall:,R-21.0 cavity insulation
Comments:Increasing from R-13
Windows:
❑ Window:,U-factor:0.320
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door:,U-factor:0.350
Comments:Front door exempt
Floors:
❑ Floor:,R-19.0 cavity insulation
Comments:Existing structure left as is.
Heating and Cooling Equipment:
❑ Furnace::82 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from
combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation.
Vapor Retarder:
❑ Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
❑ Materials and equipment must be installed\plain\f2\fs20 in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or
specifications.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
❑ Retum ducts in unconditioned attics or outside the building must be insulated to R-6.
❑ Supply ducts in unconditioned spaces must be insulated to R-11.
❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-
❑ Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Page 2
.Insulation is not required on return ducts in basements.
Duct Construction:
❑ All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives),
mastic-plus-embedded-fabric,or tapes.Tapes and mastics must be rated UL 181 A or UL 181 B.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest
zone.
Electric Systems:
❑ Separate electric meters are required for each dwelling unit.
Fireplaces:
❑ Fireplaces must be installed with tight fitting non-combustible fireplace doors.
❑ Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building
Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from
non-depletable sources.Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105°F or chilled fluids below 55°F must be insulated to the levels in Table 2.
Page 3
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water
Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes.Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Page 4