Signed Inspection Report (07-16-2020) (9).pdfINSPECTION WORKSHEET (FRM-003536-2020) Case Number:AST-0211-2020 Case Module:Permit Inspection Date:Thu Jul 16, 2020 Inspection Status:Partial Pass Inspector:Inspection Type:Building Framing Job Address:Parcel Number:409 DIX AVE Queensbury, NY, 12804 303.16-1-6 Contact Type Company Name Name Contractor Rozell Industries Inc. Applicant Schroder Rivers Associates Insulation Contractor Snyder's Drywall Engineer Schroder Rivers Associates Framing Contractor Ridgewood Homes Contractor Precise Painting Electrical Contractor Sweet Electric Contractor O'Leary Overhead Door Primary Owner South Queensbury Volunteer Fire Co Granted Permission Rozell Industries Inc. Checklist Item Status Building Inspector Notes Failed 7/16/20 Framing Partial Approval - Ice & Water Shield Approved - Fly rafter detail approved(Verified straps and blocking nailing as per Shaun Rivers detail) Framing Failed 7/16/20 Framing Partial Approval - Ice & Water Shield Approved - Fly rafter detail approved(Verified straps and blocking nailing as per Shaun Rivers detail) Jul 16, 2020 Page (1) INSPECTION WORKSHEET (FRM-003536-2020) Checklist Item Status Attic Access 22 x 30 minimum Failed Jack Studs Headers Failed Cont Hdrs/Strapping/Nailing Grid for Garage Door Failed Truss Specification Provided Failed Bracing Bridging Failed Hurricane Clips/Uplift Screws/Nail Holes Filled Failed Air Seal all Plates and Sills Failed Air Seal All Registers at Floor Failed Air Sealing all Joints Before Insulation Failed Joist hangers Failed Jack Posts Main Beams Failed Deck (post beam connections hex head bolts)Failed Jul 16, 2020 Page (2) INSPECTION WORKSHEET (FRM-003536-2020) Checklist Item Status Exterior sheeting nailed properly Failed 12 O.C.Failed Headroom 6 ft. 8 in.Failed Notches Holes Bearing Walls Failed Metal Strapping for Notches Top Plate Failed Draft stopping 1,000 sq. ft. floor trusses Failed Anchor Bolts 6 ft. or less on center Failed Ice and water shield 24 inches from wall Passed 7/16/20 Framing Partial Approval - Ice & Water Shield Approved - Fly rafter detail approved(Verified straps and blocking nailing as per Shaun Rivers detail) <4:12 pitch double layer of ice/snow underlayment - over lapped 19"Failed Soffits-Insulation Baffel Failed Windows Habitable Space Bedrooms Failed Jul 16, 2020 Page (3) INSPECTION WORKSHEET (FRM-003536-2020) Checklist Item Status 24 in. (H)Failed 20 in. (W)Failed 5.7 sf above below grade Failed 5.0 sf grade Failed Design Professional Sign-off, if required Failed Jul 16, 2020 Page (4)