Loading...
2007-756 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number. P20070756 Date Issued: Thursday, November 13, 2008 This is to certify that work requested to be done as shown by Permit Number P20070756 has been completed. Tax Map Number. 523400-290-006-0001-046-000-0000 Location: 7 GLENMAR Dr Owner. RENE & DEBORAH BROCHU Applicant: RENE & DEBORAH BROCHU This structure maybe occupied as a: Porch By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, r lie Variance, or other issues and conditions as a result of approvals by the Director of Building&Co We E nfMement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20070756 Application Number. A20070756 Tax Map No: 523400-290-006-0001-046-000-0000 Permission is hereby granted to: RENE & DEBORAH BROCHU For property located at: 7 GLENMAR Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RENE &DEBORAH BROCHU 7 GLENMAR Dr Porch $32,000.00 QUEENSBURY,NY 12804 Total value $32,000.00 Contractor or Builder's Name/ Address Electrical Inspection Agency Plans &Specifications 2007-756 844 sq ft porch $84.40 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,January 07,2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T Quee uT January 07,2008 SIGNED BY �� for the Town of Queensbury. Director of Building&Code Enforcement �y-------F�IC. USE ONLY ---------------------% `_.._-_.....-.._......- /F� - , , TAX MAP NO. -77 PERMIT NO. � 7 r FEE PAID'* BLDG,&CODES APPROVAL , . _.,..................... ............. , ........................� ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure(house)to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: l`��Z �J -�� s-��n 1\ i-,L�1�.k INSTALLERIBUILDER: � ';_� i_N ADDRESS: _ J ADDRESS: ---I LYE 11.f'PHONE NOS. V PHONE NOS. l �� � LOCATION OF PROPERTY: c SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: ESTIMATED COST OF CONSTRUCTION: $�ZCCJr� ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IF YES,PLEASE LIST: KQY1�Z_ V- I> v. -2 CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: \, 'i� Q PROPOSED CONSTRUCTION 13T FLOOR 2ND PROPOSED FLOOR TOTAL SQ.FT. SO.FT. SQ.FT. HEIGHT FT.& OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH* y BOATHOUSE v BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS:__) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application,together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS? CALL 761-8256 OR EMAIL I have read and agree to the above. codes mueensburv.net \ (� \Z-��_ ;� VISIT OUR WEBSITE FOR MORE INFORMATION Signed `' 1'ter`�`T`'`' Dated: www.aueen§bury.net Town of Queensbury- Community Development Office • 742 Buy Road, Queensbury, NY 12804 B I-LGL 11-05 Queensbury Building & Code Enforcement - Residential Final Inspection Z Office No. (518)761-8256 Arrive: 2�7 1 74-�m/a Depart: am/pm Date Inspection request received: Inspector's Initials: J z& NAME: GC PERMIT#: LOCATION: CC- ; /2 DATE: - '7 TYPE OF STRUCTURE: -_ Comments Yes No NIA Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s . ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s . ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'Y2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required ` Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Resid ntial Final Inspection ' Office No. (518) 761-8256 Arrive: , .' ( � a p Depart: am/pm Date Inspection request received: inspector's Initials: NAME: PERMIT#: LOCATION: DATE: - TYPE OF STRUCTURE: (' Comments: Yes No N/A 4" Building Number Address visible from road ChimneyHeight/"B"VenttDirect Vent Location / n S/� �� � Fresh Air Intake r 3 inch PlumbingVent through roof minimum 6 inches � —y'- i T Pic ®h Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells sa§V glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: _ Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below 9rade Gas Fumace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical'" �� L L C Final Survey Plot Plan Arc Fault Breaker in Bedrooms C�5�- Flex Gas Pipe Bonding _�— As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance re uired Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary/Permanent L:1Building&Codes FormslBuilding&CodeMinspection FormslResidential Final Inspection Forrn_revised_100405.doc;Revised January 7,2008; Revised 6126/08 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No.. ,.....n...........A......A..'.Cert. N� 94130 Cut-in Card No................................... Owner....................?CxzzG .......1 a.Gs ..�1....................................................................................... Location.............7.......�a Ls:.t l.i»,C�.�C1....Q..,.a........................................................................................... Installation Consisting of.......A.►a Lt r.t! ..I.,....511../ .t./1.L:..=.....sA.../.3 �..i..................... 7.....5.,.�s 1.�......i..�1.....0 . .J...................................................................................................................... .................................................................................................................................................................................. InstalledB ,S'.4 nn.S.r..............................................................Lic.No................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued i cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon th introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if it rules are violated,the Company shall have the right to revoke this certificate. Date....... .0...... .::(l d!................. INSPECTOR kJ 1 :.................................... Rough Plumbing l Insulation In pection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: r am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ,� NAME: Pro 6 , 0 PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Ai .S.I for minutes Insulation/Re idential Check/Commercial Check -AzFaWflar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly!No duct tape COMMENTS. ) j l �- C'`� E: 7 � -- � 7� � 11 kQ Rough Plumbing insulation Report-revised Nov V 2003, revised February 15,2005, revised January 7,2008 0b/05/2008 09i45 .5186237015 NORTH EAST UNDERLAVM PAGE 02/07 r i ICXN ENE'—Spray Formula PRODUCT SPECIFICATION Average insulauon contribution m stud wall, low vapor permeable paint on the interior 2" x 4" R13 2" x 6" - R20 drywall Is adequate. The Icynene Insulation System*provides Water Absorption Properties N more effective performance than the MEIN, equivalent R-value of air permeable is Ic nene* din y hydrophobic brc and does not insulation materials.Icynene*is not exhibit capillary properties.It does not 1- PRODUCT NAME subject to loss of R-value due to aging, wick and is water repellent.Water can be windy conditions,settling, convection or forced into the foam under pressure Icynene' and The Icynene Insulation air infiltration:nor is it likely to be because it is open celled.Water will drain System" are registered trademarks for affected by moisture related conditions. by gravity rather than travel horizontally polyicynene Insulation manufactured by AFACT SHEET with R-value data is or vertically thmugh the foam. Upon Icynene Inc.Icynene'spray formula is a available upon request drying,thermal performance is fully 1/2 lb density free rise,open celled material. restored. Air f'orlt>taearrce/Air Barrier/Air Seal 2. MANUFACTURER Acoustical Properties The Icynene Insulation System' fills any Icynene' is made on site from liquid shaped cavity,and adheres to all materials, Performance in a ?-"x4" wood stud wall: components manufactured by Icynene Ming assemblies with very low air Inc.Installation and on-site manufacturing permeance,No additional interior or STC Sound T>ansmission Class - 37 is supplied by independent Icynene exterior air infiltration protection is Hz Rreq, 125 250 500 1000 2000 4000 Licensed Dealers. necessary. ASTM E90 19 30 31 42 38 46 3. PRODUCT.DESCRIPTION Air permeability of core foam: NRC Noise Reduction CoeSrdent-70 ASTM E283 data Nz.REq. 125 250 500 1000 2000 4000 Icynene' Insulates and air seals at the 0,0049 L/S-m' @75 Pa for 5.25" ASTMC423 .11 .43 .89 .72 .71 67 same time.Its performance is less 0.0080 L/S-m-' @ 75 Pa for 3.25" installation sensitive than factory Actual performance is superior than manufactured insulation materials.It Is an In all buildings, adequate mechanical reported test results because of Icynene"s effective"breathing"air barrier that can ventilation/air supply should be provided ability to control air leakage. adjust with the building to maintain a seal for optimum IAQ (Indoor Air Quality). against energy-robbing air leakage for the See ASHRAE Culdelines, Burn Characteristics life the building.Convective air Water Vapor Permennec Icynene'will be consumed by flame,but movement inside cavities IS virtually will not sustain flame upon removal of eliminated,providing more uniform p temperatures throughout the building. Icynene°° is water vapor permeable and the flame source.It leaves a charcoal The result is superior quality allows structural moisture to diffuse and residue.It will not melt or drip.It should construction,with higher comfort levels dissipate,It will not entrap moisture in be applied in accordance with applicable and lower heating and cooling costs. materials to which it is applied. building codes. Energy savings vary depending on Water vapor transmission properties: U.S.A.Spe '•rcatiens building design,location,etc. ASTM E96 data Surface Burning Characteristics of Icynene* Is applied by spraying liquid Icynene'ASTM E84 components onto an open wall,crawl 16 perms 941 ng/(Pa-s-rO @ 3" (76mm) thick Flame Spread <20 space or ceiling surface, There they 10 perms 565 ng/(Pa-s-mj @ 5" 027rnnn thick Smoke Development <400 expand 100:1 In just seconds to provide a Fuel Contribution 0 flexible foam blanket of millions of tiny Because of its low air permeance, Oxygen Index ASTM D2863 23% air cells,filling building cavities and Icynene' is not infiltrated by moisture NX State Fite gas toxicity LC,n-12 sealing cracks and crevices in the process, laden air.Computer modeling of moisture it adheres to virtually all surfaces,sealing movement in walls using a program out air infiltration.Excess material is (MOIST) developed by Doug Burch of the CANADA Speclfications easily trimmed off,leaving a surface ready National institute of Standards and Corner Wall Test CAN4-Si02 FSC3 for drywall or other finish, 1hrhnology (NISI) suggested that a 1,0 Flame Spread 510.530 perm rating was not required when Smoke Development 95-150 4. TECHNICAL DATA Icynene*insulation was used,except in (Based on Core Samples) climates as cold or colder than Madison, Wisconsin (7500 Ideating degree days). Thermal Performance This conclusion was In general agreement with other computer modeling of Thermal resistance R/In. (Rsi/25mm) moisture movement in building envelopes ASTM C518: R3.6 hr.ft' "F/BTU performed in Canada.In those situations Rsl 0,62 m' "C/W that warrant a vapor barrier,the use of eb/e5/:Z0Ub b;1:45 5186237015 NORTH EAST UNDERLAYM PAGE 03/07 Electrical Wiring 5. INSTALLATIONS 10-PACKAGING AND STORAGE Icynene" has been evaluated with both The.Icynene Insulation System' Is Packaging - 55 U.S.gallon open top steel 14/3 and 12/2 residential wiring (max. Installed by a network of Licensed drums 122°F/50"C).It Is chemically compatible Dealers,trained in the installation of Component'N - 550 lb,per drum with all electrical wiring coverings. Icynene. Installation is generally Base Seal' - Polyisocyanate NMI independent of environmental conditions. Component'B' 500 lb.per drum Note; For any insulation of knob and It can be installed in hot,humid or Gold Seal® -Resin tube wiring,please reference local freezing conditions.Surface preparation is electrical code. generally not necessary.Within minutes, Storage the foaming process is complete. Corrosion Component A should be protected from Icynene did not cause corrosion when 6. AVAILABILITY freezing. evaluated in contact with steel under Check regional yellow pages or contact Component B can be frozen but must be 85% relative humidity conditions. Icynene Inc.at 800-758-7325 or our protected from overheating (I20"F/49'C) website at wwwIcynene.r_om, and prolonged storage above Bacterial or Fungal Growth and 1OW17/380C.Component B separates Food Value 7. WARRANTY during storage and should be mixed thoroughly prior to use. Independent testing conducted by Texas WHEN INSTALLED PROPERLY IN 7kh University has confirmed that ACCORDANCE WITH INSTRUCTIONS, 11. INSTALLATION Icynene*is not a source of food for THE COMPANY WARRANTS THAT SPECMCATIONS mold;and as an air barrier,Icynene' THE PROPERTIES OF THE PRODUCT reduces the airborne introduction of MEET PRODUCT SPECIFICATIONS AS Refer to the Icynene installer's Manual moisture,food,and mold spores into the OUTLINED IN THIS PRODUCT for expanded information. building envelope.It has no food value SPECIFICATION SHEET. for insects or rodents. 8. TECHNICAL Environmental/Health I Safety Icynene Licensed Dealers and Icynene Inc. Icynene' contains no.formaldehyde or provide support on both technical and volatile organic compounds.It has been regulatory issues.Architectural thoroughly evaluated for In-situ emissions specifications in CSI 3-Part format are by industry and.government experts. available upon request. VOC emmissions are below I/100 of the safe concentration level within hours 9. .RELATED REFERENCES following the application of Icynene'.A 24 HR waiting period Is recommended All physical properties were determined for highly sensitive people prior to through testing by accredited third party occupancy. agencies.Icynene Inc.reserves the right to change specifications In Its effort to Not intended for exterior use.Not to be enhance quality features.Please confirm installed within 2" (50 mm) of heat that technical data literature is current. emitting devices.where the temperature is in excess of 2001(93°C). Qo ICYNENE., The Icynene Insulation System* Healthier,Quieter, More Energy Efficient Telephone! 905,363,4040 Toll Free: 800.758.7325 Facsimile: 905.363,0102 Website: www.icynene.com E-mail: inquiry@lcynene,com 7ro3/PSA NORTH EAST UNDERLAYM PAGE 04107 LEGACY REPORT NER-420 Re-issued May 1, 2003 'rrryliM" wp ICC Evaluation Service, Inc. susir*!5 gl°nar Offiev,936o Wykrmn Mal 'V+AM-,COiDn a MI.(562)s99. m3 Regional Office■900 Montclair Road,Sul%A Birmingham,Alabama 35213 ■t2m)s9g•saw www.icc-es.org Regtonel Office a 4051 West Fbssmoor Road,Country Club Hira,11inoia R978 a(708)799-2305 Legacy Report on the 2000 International Building Cade®with 2002 Accumulative Supplement, the 2000 International Residential Code@ for One-and Two-Family Dwellings with 2002 Accumulative Supplement, the BOCA@ National,Building Code/1999,the 1999 Standard Building Code®,the 1997 Uniform Building Code*"",and the international One and Two Family Dwelling Code©1998, ICYNENE INC. 3.2 Surface Bunning Characteristics 6747 CAMPOBELLO ROAD MISSISSAUGA, ONTARIO, When tested in accordance with ASTM E 84, The CANADA L5N 21-7 Icynene Insulation System®has been shown to have a 800.768.7325 flame-spread index(FSi)of less than 25 and a smoke- www.icynene,com development index (SDI) of less than 450, when installed at a maximum thickness of 5.5 inches (140 Division 07—Thermal and Moisture Protection mm)and a nominal density of 0.5 pcf+/-10%(8 kg/m3). Section 07210—Building insulation 1.0 SUBJECT 3.3 Thermal Resistance The Icynene Insulation System@ The Icynene Insulation System® has a thermal resistance of 5.7°F.ft2.hrBtu when tested at a thickness 2.o PROPERTY FOR WHICH EVALUATION IS of 1,6 inches(41 mm)in accordance with ASTM C 518 SOUGHT at a mean test temperature of 75°F(24°C). 2.1 Surface Burning Characteristics 4.0 INSTALLATION 2.2 Thermal Resistance 2.3 Fire Resistance Rated Wall Assemblies, see 4.1 General Section 4.4 2.4 Attic and Crawl Space Installation,see Section The Icynene Inc. The Icynene Insulation System® 4.3 Installers Manual,Copyright@2000 and this report shall be strictly adhered to and a copy of these instructions 3.0 DESCRIPTION and this evaluation report shall be available at all times on the job site during installation. 3.1 General The Instructions within this report govern if there are any The Icynene Insulation System®is a low-density,plastic conflicts between the manufacturer's instructions and foam that has an open-cell structure. The material is a this report. two component system,spray-in-place vaporpermeable product used to insulate the building envelope and air- 4.2 Application seal areas such as plumbing and wiring penetrations, rim joists areas,window frames,overhangs,porch and 4.2.1 General: The Icynene insulation System® is garage ceilings and exterior walls_ Upon completion of applied using spray equipment specified by the expansion, the open cells contain only air. The manufacturer at the construction site on chemical reaction that occurs while Icynene Insulation vertical and horizontal substrates, and the System® is being applied takes place in seconds,with underside of horizontal surfaces to fill gaps less than five minute curing time needed. After curing, and cracks in building materials to create an the air-seal remains flexible. air seal and to provide an insulating barrier. The Icynene insulation System®shall not be used in areas which have a maximum service 1('l..'JsS lq ocy mpnNs arr.nal M hr cnnrtrtMd a<'repreAonOng aemheti6-r ar ath,ether a/tribxfnT not.fJJeclfleally addrr..vved,new are.they to lte comervieci at an ouMrvemrnt of Nh'rubject of the report a a recomwndatlonfor ht eke.AL Pe it m•i worranty by 1C'Clvnlr alfan Serular.Inc.,exprece ar lmplietf,as ra any ! f{ndl nX or ofher mailer is Aft report.nr av fn any product covered by Aw rtpor[. erwrsw w�•� Page 1 of 4 copyright020(n 06/05/2008 09:45 5186237015 NORTH EAST UNDERLAYM PAGE 05/07 Page 2 of 4 NER-420 temperature greater than 180' F(82'C).The is permitted to be installed exposed in an attic foam shall not be used in electrical outlet or or crawl space without a thermal barrier or junction boxes or in contact with rain or water. ignition barrier under the following conditions.- The Icynene Insulation System® shall be protected from the weather after application_ 4.3.2.1 Entry to the attic or crawl space is limited to service of utilities; 4.2.2 Maximum Thickness.The Icynene Insulation 4.3,2.2 There are no interconnected basement or attic System® shall not have a thickness areas; exceeding 5.5 inches(140 mm)and shall have 4.3.2.3 Air in the attic or crawl space Is not circulated a nominal density of 0.5 pcf+1-10%(8 kg/m3). to other parts of the building; A nominal thickness of 6 Inches (152 mm) is 4.3.2.4 Ventilation of the attic or crawl space is permitted in attics and crawl spaces described provided in accordance with the applicable in section 4.3 below. Code. 4.3.2.5 The Insulation shall be limited to a maximum 4,2.3 Licensed Dealers: The Icynene Insulatlon nominal thickness of 6 inches(152 mm)and is System® shall only be installed by licensed installed on the underside of the top space and dealers. Licensed Dealers have been on vertical wall surfaces and the Insulation is previously certified by Icynene inc. to Install covered with FireFree 88 at an application rate the Icynene Insulation System& The installer of 1 gallon per 100 ft2. shall provide the building official with a letter noting the installation was in accordance with 4,3.3 Assembly No. 3, Attics and Crawl Spaces: the manufacturer's instruction and this The Icynene Insulation System®is permitted evaluation report along with the date,address to be installed within attics or crawl spaces,on of installer,company's name, installer's name the underside of the top of the space and on and certification number_ vertical wall surfaces with the insulation on the walls protected by an ignition barrier(see 4.3.5 4.3 Thermal Barrier below) and the insulation of the top space not covered, under the following conditions: The Icynene Insulation System® shall be separated from the interior of the building by an approved thermal 4.3.3.1 Entry to the attic or crawl space is limited to barrier of 0.5 inch (12.7 mm) gypsum wallboard or service of utilities; equivalent 15 minute thermal barrier complying with the 4.3.3.2 There are no interconnected basement or attic applicable Code, except within an attic or crawl space areas; see section 4.3.1 through 4.3.6 below: 4.3.3.3 Air in the attic or crawl space is not circulated to other parts of the building; F43.1.1 Assembly No. 1, Attics and Crawl Spaces: 4,3.3.4 Ventilation of the attic or crawl space is The Icynene insulation System® installed provided in accordance with the applicable within attics or crawl spaces on the underside Code. bof the top of the space is permitted to be 4.3.3.5 The insulation shall be limited to a maximum installed exposed in an attic or crawl space nominal thickness of 6 inches (152 mm). without a thermal barrier or ignition barrier under the following conditions: 4,3.4 Assembly No.4,Attics and Crawl Spaces: The Icynene Insulation System®is permitted Entry to the attic or crawl space is limited to to be installed within attics or crawl spaces,on service of utilities; vertical wall surfaces with the insulation on the 4.3.1.2 There are no interconnected basement or attic walls protected by Fire Free 88,and the top of areas: the space is not Insulated,under the following J 4,3.1,3 Air in the attic or crawl space is not circulated conditions: y, to other parts of the building; X 4.3.1.4 Ventilation of the attic or crawl space is 4.3.4.1 Entry to the attic or crawl space is limited to provided in accordance with the applicable service of utilities; Code. 4.3,4,2 There are no interconnected basement or attic 4.3.1.5 The insulation shall be limited to a maximum areas; nominal thickness of 6 inches(152 mm)and is 4.3.4.3 Air in the attic or crawl space is not circulated installed on the underside of the top of the to other parts of the building; space, roof deck and ceiling joists and floor 4.3.4.4 Ventilation of the attic or crawl space is deck and floor joists and shall not be installed provided in accordance with the applicable on vertical surfaces. Code. 4.3.4.5 The insulation shall be limited to a maximum 4.3.2 Assembly No. 2, Attics and Crawl Spaces: nominal thickness of 6 inches(152 mm)and is The Icynene Insulation SystemO installed covered with FireFree 88 at an application rate within attics or crawl spaces on the underside of 1 gallon per 100 ft2. of the top space and on vertical wall surfaces and the insulation is covered with FireFree 88 0b/05/2008 0S�:45 5186237015 NORTH EAST UNDERLAVM PAGE 06/07 Page 3 of 4 NER-420 4.3.5 Assembly No, 5,Attics and Crawl Spaces: (127 mm). Two layers of minimum 5/8 inch The Icynene Insulation Systeme installed thick type FSW gypsum wallboard is attached within attics or crawl space where entry is perpendicular to the joists on the ceiling side made only for service of utilities an Ignition of the assembly. The first layer is attached barrier consisting of either 15-inch-thick(38 with 1-1/4 inch (31.75 mm) Type W drywall mm) mineral fiber insulation, 0.25-inch-thlck screws, spaced 24 inches (609.6 mm) on (6.4 mm)wood structural panel,particle board center. The second layer is applied or hardboard, 0,375-inch-thick (9,5 mm) perpendicular to the joists, offset 24 inches gypsum wallboard, corrosion-resistant steel (609.6 mm)from the base layer. The second having a base metal thickness of 0.016-inch layer is attached with 2 inch(50.8 mm)Type S (0.4 mm) or other approved material is drywall screws spaced 12 inches (304.6 mm) installed in a manner that the foam plastic on center. Additional fasteners are installed insulation is not exposed. The protection along the butt joints of the second layer, covering shall be consistent with the securing the two layers together, The requirements for the type of construction fasteners are 1-1/2 inch (38.1 mm) Type G required by the applicable Code, drywall screws and were placed 2 inches(50.8 mm) back from each end of the butt joint and 4A Fire-Resistance Rated Wall Assemblies spaced 12 inches(304.8 mm)on center. The wallboard joints on the exposed side were 4.4.1 One Hour Fire Resistance Rated Load treated with paper tape embedded in joint Bearing Wood Stud Wall Assembly: compound and topped with an added coat of Minimum 2x4 No.2 Southern Pine(G=0.55) compound. The fastener heads were coated spaced 16 inches (406.4 mm)on center with with joint compound. a base layer of%inch (12.7 mm)Wood fiber sound board on each face attached with 6d 5.0 IDENTIFICATION Box nails, 2 inches(50.8 mm)long spaced 24 inches (609.6 mm) o.c. along studs, second All packages and containers of The Icynene Insulation layer of 518 inch (15.88 mm)Type X Gypsum System®covered by this report shall be labeled with the Wallboard on each face attached with 8d Box manufacturer's name/and or trademark, address, the nails, 2-1/2 inches (63-5 mm) long spaced 7 product name, the flames-spread index, the smoke- inches(177.8 mm)o.c.along studs. The stud development index, the shelf life expiration date, the cavity is filled with 2 inches(60.8 mm)nominal label of the quality control agency, Intertek Testing thickness oflcyneneInsulation-Allowableload Services, NER-QA219 and this National Evaluation of 1,805 pounds (8122,5 N) per stud, 78% Service evaluation report number, NER420. design. 6.0 EVIDENCE SUBMITTED 4.4.2 One Hour Fire Resistance Rated Load Bearing Wood Stud Wall Assembly: 6,1 Manufacturer's descriptive literature, Minimum 2x4 No.2 Southern Pine(G=0.55) specifications, and installation instructions. spaced 16 inches(406.4 mm)on center with two layer of/Z inch(12.7 mm)Type X Gypsum 6.1,1 Icynene Inc.The Icynene insulation System® Wallboard on each face attached with 8d Box Installer Manual, Copyright®2000. nails, 2-1/2 inches (63.6 mm) long spaced 7 6.1.2 Product Specification Icynene-Pour Formula, inches (177.8 mm) o.c. along studs for face 11/2/PSB. layer and 6d Cement Coated Box Nails, 2 6.1.3 Product Specification Icynene - Spray inches 950.8 mm) long spaced 24 Inches Formula, 11/2/PSA. (609.6 mm)o.c-along studs,base layer. The stud cavity is filled with 2 inches (50.8 mm) 6.2 Test reports on surface burning characteristics nominal thickness of Icynene Insulation. under ASTM E 84, Warnock Hersey Allowable load of 1,805 pounds(8122.5 N)per Professional Service Ltd_, Report No. 7171, stud, 78% design. File NO,03329-50296-C7-717700,July 1988, signed by Bob Davison,C.E,T Letter report on 4.4.3 One Hour Fire Resistance Rated 5-1/2 inch thickness, February 21, 1989, Floor/Celling Assembly:Minimum 2x10 No.2 signed by Bob Davison, C.E.T. Douglas Fire wood joists spaced 24 inches (609.6 mm)on center, Bridging minimum 1 x3 6.3 Test report on the Icynene Insulation System® Spruce. Floor decking is minimum ''/z inch for SwRI Procedure 99-02, Crawl Space (12.7 mm) thick exterior grade plywood Exposure Evaluation, Omega Point installed perpendicular to joists and fastened Laboratories,Inc.,Project Nos.16600-111778, with 2 inch ring shank nails 6 inches (152.4 -111779,-111780,111781,-111861,-111862, mm)at the joints and 12 inches(304.8 mm)on August 1,2002,signed by Majid Mehrafza and center at the intermediate joists. Plywood William E. Fitch, P.E. joints shall occur over joists.icynene Insulation is applied to the underside of the plywood deck 6.4 Engineering evaluation,Assessment of SwR1 and to sides of joists to a depth of 5 inches Procedure 99-02 Test Results, Koffel nbr n5i Teets b'J:45 . 5186237015 NORTH EAST UNDERLAYM PAGE 07/07 .Page 4 of 4 NER-420 Associates, Inc., KAI 02190-004, August 16, 7.3 The Icynene Insulation Systemg shall be 2002,signed by Eric N.Mayl,P.E.and William separated from the Interior of the building by E. Koffel, P.E. an approved 15 minute thermal barrier see 6.5 Test report on Icynene Insulation System for section 4,3 of this report, determination of thermal insulating Exception* characteristics under ASTM D 518, National The icynene Insulation SystemO installed in Research Council of Canada, Report No. CR attics and crawl spaces may be exposed when 5506-6, February 22, 1998. installed in accordance with Section 4.3 above, 6.6 Test reports on fire resistance rated wall 7.4 The Icynene Insulation System® shall not assemblies under ASTM E 119, Inchcape exceed the thickness and density noted in Testing Services NA, inc_, signed by R. section 4.2.2 of this report. Joseph Pearson and R, Davison: 7.5 The Icynene Insulation System®shall not be 6.6.1 One hour wall, wood studs 2x4 at 16 inches deemed to add to the structural strength of any o.c. with 1 layer of '/ inch sound board on wall assembly or used as a nailing base. each side and 1 layer of 5/8 inch Type X gypsum wallboard on each side, Report No. 7.6 The Icynene Insulation System®has not been 295-1358-96-01, November 11 & 12, 1996. evaluated for use as a firestopping material or through-penetration system_ Fire Resistance 6,6.2 One hour wall, wood studs 2x4 at 16 inches Rated Wall and Floor/Ceiling Assemblies are o.c, with 2 layers of 1/z inch Type X gypsum listed in Section 4.4 of this report. wallboard on each side,Report No.295-1358- 96-02,November 21 1998. 7.7 The Icynene Insulation System®is required to be protected from the weather after 6.7 Quality Assurance Program, Intertek Testing application. Services, March 05/01, 7.8 The icynene Insulation System® shall be 6.8 Test reporton fire resistance rated floor/ceiling applied by contractors certified in accordance assembly under ASTM E 119, NGC Testing with section 4.2.3 of this report. Services, Assignment K-743. Test NO. FC- 559,December 17,2001,signed by Richard A. 7.9 The Icynene Insulation System®shall not be Costolnick and Robert J. Menchetti, installed on the exterior of foundation walls or 7.0 CONDITIONS OF USE below floor slabs on ground. In jurisdictions that have adopted the Standard The ICC-ES Subcommittee for National Evaluation Building Code,the International One and Two Service finds that The Icynene Insulation System®as Family Dwelling Code and the International described in this report complies with or is a suitable Residential Code when the Icynene Insulation alternate to that specified in the 2000 International System® is installed in buildings of wood Building Code©with 2002 Accumulative Supplement, construction the insulation shall not be the 2000 International Residential Code®for One-and installed on the exterior of foundation walls or Two-Family Dwellings with 2002 Accumulative below floor slabs on ground or in contact with Supplement,the BOCAO National Building Code/1999, the ground. The Icynene Insulation System® the 1999 Standard Building CodeQ, the 1997 Uniform shall have a clearance above grade and Building Code TM", and the International One and Two exposed earth of 6 inches (152 mm) or Family Dwelling Code 1998 subject to the following greater. conditions- 7.10 The lcynene Insulation System®has not been 7.1 This Evaluation Report and the installation evaluated for use with exterior walls of instructions,when required by the code official, buildings of noncombustible construction shall be submitted at the time of permit under 2603.5 International Building Code, application. 2603.6 Standard Building Code,2603.6 BOCA National Building Code and 2602,522 7.2 The Icynene insulation System® shall be Uniform Building Code. Installed in accordance with the manufacturer's published installation 7.11 This report is subject to periodic instructions, this evaluation report and the re-examination_For information on the current applicable Code, status of this report, consult the ICC-ES website. Framing / Ire topping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart:<� 2� am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ZL� NAME: �a ) PERMIT#: — (�' LOCATION: INSPECT ON: TYPE OF STRUCTURE: FramingY N WA COMMENTS: ss 220 x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12A O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses or less on center icerandter shield 4 inches from wall 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (1N) 5.7 sf above/below grade 5.0 sf grade LABuiiding&Codes Fortes-QLMSuifd ft&COdesftspection FomnslFrwft Restopping inspection Report.doc Revised January 7,2W8 Foundation Inspection Report Office No.(518)761-8256 Date Ins ti uest received: Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto 's I ials. ' NAME: J PERMIT#: C/ LOCATION: r-- INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this se on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width Ts above footing ( 6 '1 1 for wet areas under slab Backfill roval :ii�mg Under Slab PVC/Cast/Copper Foundation Insulation interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24.00 AM Foundation Inspection Report Office No.(518)761-8256 Date Ins ect�io�request received: Queensbury Building&Code Enforcement Arrive: �-am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials. V,61 NAME: I oc,4"i PERMIT#: LOCATION: Q INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the Mat i s for this o on site. Four ion/Wallpour Reinfor0Aft04Zf16ce Foo ' Dowels 01 Keyway in place Foun on Dam0proofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM IOE3D' Ay Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: �am/pm � Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's In"itials:`j NAME: rC PERMIT#: _ S(p LOCATION: INSPECT ON: TYPE OF K C . Comments N N/A Footings iers Monolithic Slab Reinforcement in Place ✓ i The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Fonns\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM a a• . f x. a=�� � • � v "� 'sue.'n #, + ,,. 46 S i o 1 4 9 SL j 3 f +s+ r a