Signed Inspection Report (07-22-2020).pdfINSPECTION WORKSHEET (FDTN-003685-2020)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0255-2020 Case Module:Permit
Inspection Date:Wed Jul 22, 2020 Inspection Status:Failed
Inspector:Dyer, Charles Inspection Type:Building Foundation
Job Address:Parcel Number:12 HALL RD EXT
Queensbury, NY, 12804
289.11-1-17
Contact Type Company Name Name
Primary Owner Leonardo, Rebecca
Granted Permission Rosewood Home Builders
Applicant Leonardo, Adam
Primary Owner Leonardo, Adam
Applicant Leonardo, Rebecca
Engineer VanDeLoo, Walter
Contractor Rosewood Home Builders
Checklist Item Status
Building Inspector Notes Failed
7/16/20 footings and 3 piers approved
7/20/20 frost walls approved, provide a stamped updated foundation plan showing the changes made at the frost
walls.
Footings Passed
8" x16" footings approved
Piers Passed
24"x 24" x12" piers approved with 2 #4 rebar each direction
Monolithic Slab Failed
Jul 22, 2020 Page (1)
INSPECTION WORKSHEET (FDTN-003685-2020)
Checklist Item Status
Reinforcement in Place Passed
2 rows of #4 rebar continuous, vertical dowels to be wet set
Foundation / Wallpour Passed
7/20/20 frost walls approved, provide a stamped updated foundation plan showing the changes made at the frost
walls.
Reinforcement in Place Passed
7/20/20 frost walls only: one row of # 4 rebar continuous at top of wall.
Masonry Wall Failed
Reinforcement in Place Failed
Footing Dowels or Keyway in place Failed
Foundation Dampproofing Failed
Foundation Waterproofing Failed
Footing Drain Daylight or Sump Failed
Footing Drain Stone - 12 inch width Failed
Footing Drain Stone - 6 inches above footing Failed
Provide stone @ footings as discussed prior to applying footing drain
Jul 22, 2020 Page (2)
INSPECTION WORKSHEET (FDTN-003685-2020)
Checklist Item Status
Footing Drain stone - 6 mil poly Failed
Backfill Approval Failed
Plumbing Under Slab Failed
PVC / Cast / Copper Failed
Foundation Insulation Interior / Exterior Failed
Rough Grade 6 inch drop within 10 ft.Failed
Poly Under Slab Failed
Jul 22, 2020 Page (3)
Dyer, Charles