2004-703 � ` TOWN OF QUEENSBURY
742 BayRoad,Queensbury, 12804-5902 (518) 7 1- 2�� Q ry, 6 8 01
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20040703 Date Issued: Tuesday, June 05, 2007
This is to certify that work requested to be done as shown by Permit Number P20040703
has been completed.
Tax Map Number: 523400-240-000-0001-007-000-0000
Location: 2352 RIDGE Rd
Owner: PHILIP & RITA MC INTIRE
Applicant: PHILIP & RITA MC INTIRE
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the �'. _�` 04.4)
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals bythe
ppDirector of Building&Code orc nt
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
F0,0
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040703 Application Number: A20040703
Tax Map No: 523400-240-000-0001-007-000-0000
Permission is hereby granted to: PHILIP MC INTIRE
For property located at: 2352 RIDGE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: PHILIP MC INTIRE
RITA MATTHEWS Residential Addition $12,000.00
Total Value $12,000.00
2352 RIDGE Rd
QUEENSBURY, NY 12804
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2004-703
231 SQ FT RESIDENTIAL ADDITION
$75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, September 16, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To eensb ; T rs ay, September 16, 2004
SIGNED BY I for the Town of Queensbury.
Director of Building& ode E orcement
Building Permit Application
Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256
•
A permit must be obtained before beginning construction. Permit File No.C 7. 3
No inspection will be made until applicant has received a Fee Paid . -
valid building permit. All applicants' spaces on this Rec.Fee Pai•
application must be completed and must appear on the Reviewed
application form. / •
Applicant -1.e s to L I QZ'.n Owner. S R
Address: e2 35,a "�,� � 2p�� Address:
Ct,t . E.M$3u e-,.w , ply i 24
Phone#(5_,iji)Ste- 959(,.. Phone#( )
Property Location: Lot Number: / House Numbero73 5 2/ o)(d 0
Subdivision Name: kJ/A Tax Map Number: cP•'`4 o—1 -7.
• New Building: residence /commercial Estimated Market Value of Construction: $ I al =
g Addition' cAlrffn commercial If an Addition,what will use of new addition be?
0 Alteration: residence/ commercial J),, — �
0 No change to exterior size: residence/com'l •
O Other work(describe )
Check OccupancyInformation 1"Floor 2"Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
O Single family dwelling
0 Two family dwelling
O Townhouse
o Multifamily dwelling �a�
#of units /Vc®
o Office
• Mercantile SFp 0 8 2001
0 Manufacturing TQW
0o 1 oar detached garage BU p A, E NSBVR
2ardetachedprage �E Y
O 3 car detached garage
O 1 car attached garage
O 2 car attached garage
O 3 car attached garage
O Storage building-
commercial
o Storage building-
residential
Other p,, a , i •
What is the proposed height of the structure t 1 feet L ,inches
Will any second-hand or ungraded lumber be used? If so,for what? �10
Type of Heating System: electric/ oil 4%5 wood /forced hot air/ •aseboar /other:
Number of,F'1renlaces to be installed CD Number of Woodstoves to be installed O
List below the person(s)responsible for supervision of work as regards to building codes:
Name Address- Phone Number
Builder CV,K.. s Ta F1,e..e Sa.s-ram. 5 i 8 89 )—7 471'L
Plumber 5s.% 2, Eft", t ' E
Mason s LP**,[E. I 11-9 I
Electrician
Declaration: please sign below after you have carefully read the statement
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Orca4i,im a and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administraor wirector ocftiBuilding and Codes,ands Built Sum ty by a licensed surveyor;drawn to scale,showing actual
loudSigns er, er s agent,architect,contractor
N
COMPLIANCE APPLICATION
�+�'- �� _ ENERGY CODE
�-�i TOWN OF QUEENSBURY, WARREN COUNTY
000 HEATING DEGREE DAYS
Complies Methods:Part S -Acceptable Practice Method-1&2 Family Dwellings(only)
Part 6*-Thermal Rating-Component trade Offs 1&2 Family Dwelling;
Multi-Family Dwellings(3 Stories or less)
Part 4*-Design by Component Performance,Commercial Buildings-Hi
Rise Residential
*Requires submission of worksheets
PLICANT'S NAME: PROPERTY OCATIO
PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE:
1. Gross Floor Area- pZ 3 1 square feet
2. Type of heat- Electric - Oil X Gas Other
3. Is building mechanically cooled? yes __—No
4, percentage of area of windows and doors
x Over 17% Under 17%
• 5. R-VALUES FOR INSULATION GIVEN BEL•OW MUST CORRESPOND TO R VALUES AS.
SHOWN ON PLANS SUBMITTED: R $
lox is . e- a: Roof Cotc r i-4e A•L- 02-�c t Z--N R- -
b. Exterior walls --R- �U . 0 • 3
c. Glazed areas R l�, O• � Jr
d. Exterior doors R �/�
e. Floors over unheated spaces R $
f. Edge of slab on grade(heated building)
g•
Basement/cellar walls(above grade) R NI/Pc
NIAc
h. Basement/cellar walls(below grade) R R ql•
•
i. Heating/cooling-ducts-piping in unheated space ay
-7X13 3--.. 1?...00 F •• --..-`. A-c- e_-—i I
6 Service(domestic)hot water heating device
Conforms to minimum efficiency per code f ` Yes No
TEMPERATURE CONTROL MAXIM
UM SETTING 140—*ILL NOT B EXEEDED� ,:ecci.
l is ignat 0Date Phone N ber
SPECTOR'S REMARKS:
1
DUE: tsuuaing rnergy e;oaes-riome rags ti vn i
y.-.
U.S.Department of Energy
Office of Energy Efficiency and Renewable Energy Bringing you a prosperous future where energy is
dean,abundant,reliable,and affordable
flUAttdiiitiWeriTerVigffeedeS
leifrom the U S Geaarrme:iIEoer,`y
Your resource for tools to Highlight
Search for: f facilitate energy code T the new
I compliance, development, Try
REScheck-Web online
Search adoption, implementation, and code compliance tool!
enforcement.
Free Software
Downloads
REScheck, REScheck for Mac,
COMcheck-EZ
rt =p Compliance Tools News & Events
Residential (REScheck) 2003 National Workshop
1 " Commercial (COMcheck) Setting the Standard Newsletter
Federal Building Standards Calendar of Events
REScheck Package Generator Latest Proposed Code Changes
Training Tools Implementation Tools
Training Presentations/ Orders DOE Determinations
State Training Events DOE Assistance
Consumer Education Resource Materials
Energy Codes Glossary Status of State Energy Codes
r-
On-line Training Tool Now r �J wy
Available!
See our new on-line training tool to
learn the basics of complying with the
2000 International Energy Conservation z.;1"
Code (IECC) using the REScheck tools.
Tech Support Webmaster EERE Home
Security&Privacy
U.S. Department of Energy
Last updated: 28 June 2003
jttp://www.energycodes.gov/ 7/1/2003
Queensbury Building & Code Enforcement - Resid al F. al Inspection X — 70-147
i
Office No.(518)761-8256 /Zt;1�h Arrive: �rt• a
Date Inspection request received: II '7� l V Inspector's Imti 1
NAME: eL IT#: •
LOCATION: SwL el < jL p , ATE:
TYPE OF STRUCTURE: A %e.; .“4/1
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq. ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum''Y2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/'/4 hour fire door/door closer
Duct work Sealed properly r Aer.
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan 11.1
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. �• �
Main Office 176 Doe Run Road-Manheim,PA 17545 ,..,
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
'ermit No. Cert. N 0 90550 Cut-in Card No
)caner ;' -/2-<.?
.,ocation...47 3 S 4 6 6 ,2 - C67.
nstallation Consisting of {//'4 . 7-4' T +rJsi"d�.
/ P P2. v
nstalled By ie.:.... /1.f 7 Lic.No.
The conditions following governed the issuance of this certificate,and any certificate previously issued is
:ancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
ntroduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of ma inspections at any time, and if its
ules areviolatted,the Company shall have the right to rev th s ce 'ficate.
/
Sate f f v ` INSPECTOR
Member N.F.P.A.,I.A.E.I.
r7-/tc6 io,eo M
Queensbury Building & Code Enforcement - Residential Final Inspectionc—ATAN
Office No.(518)761-8256 Arrive: Ic,()� pm , epa pm
Date Inspection request received: Inspector's Intti s:
NAME: r T#: 3
LOCATION: c ATE: U
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches �I' � ����
Interior Handrails stairs 2 or more risers N`.P
Grade away from foundation 6 inches with 10 feet t Ir 9 t G.,
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade TD '\� \\C)I
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum''A"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/0[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
P
Rough Plumbing / Insulation Inspection Report
Office No. (518)761-8256 Date Inspection requ-: -ceive a ` ""''—
Queensbury Building&Code Enforcement Arrive: p v A • :art: Ma pm
742 Bay Road, Queensbury,NY 12804 Inspector's Init . :
NAME: &eZ ;-c--I. PERMIT #: 70ny=7e 3
LOCATION: 2_,352_ SAD(; c ) INSPECT ON: 1- c-p-t
TYPE OF STRUCTURE: �, _ p\4p
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper,CPVC,Pex One and Two-Family
4(Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
CA‘c \
Rough Plumbing / Insulation Inspection Report 6
Office No. (518) 761-8256 Date Inspection request -ce. es
Queensbury Building&Code Enforcement Arrive: ., p De art: it
742 Bay Road, Queensbury,NY 12804 Inspector's Initats:
NAME: P\NaD- Z\V\,\QT-47L, _,
PERMIT #: 0 ` 63LOCATION: ��S � c INSPECT ON: -
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1, R-2, R-3,R-4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 '/z inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
I per Commercial
ooper,CPVC,Pex One and Two-Family
sulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sea rl
COMMEN .
L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
n---NO 10-1 fon
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection r ue rece* :d:
Queensbury Building& Code Enforcement Arrive: am/p fr-part: v g.ce
742 Bay Road, Queensbury, NY 12804 Inspector's Ini als:
NAME:" T PERMIT#: O 76 3
LOCATION: ;3S I?- f Rd_ INSPECT ON: • /
TYPE OF STRUCTURE: `
Y N N/A
Framin
— COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 Y2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
e n sno 'eld 24 inches from wall
Fire separation 1, 2, 3 hour
re wall 2, 3, 4 hour•
estorpin
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation House side 1/2 inch or 5/8 inch Type X _ A E
_ ‘3 to
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.codes-.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
i4940j l
h -
---/ Jr,,,
(t-
,,,_,,a.ctl . ?
Rough Plumbing / Insulation spection Re $ ort
Office No. (518) 761-8256 Date Inspection request e'ved• - , _.00
YIESrli
Queensbury Building& Code Enforcement Arrive: pm . ►.it:
742 Bay Road, Queensbury,NY 12804 Inspector's Init . •.
NAME: ( �� _-- ---c....„ PERMIT #: aCin#-7O
3
LOCATION: (; -St le_ _ INSPECT ON: 7 � 0
TYPE OF STRUCTURE: ,0 -
Y N N/A
PVC: R-1, R-2,R-3,R-4 Drain/Vents
Cast Iron, Copper Drain I Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 A inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
1 CPVC,Pex One and Two-Family
nsul esidential Check/Commercial Check Q�._._-kc
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation — r--\1 Q_
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
ii4 .Y.C\5 . .C7)
COMMENTS: IcV
'OA\1)\\1 ,,,\ C7'
L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: ,
Queensbury Building&Code Enforcement Arrive: anvur� Depart: •Z am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: PERMTT#: 01-1' Y
LOCATION: a r _ INSPECT ON:
-
TYPE OF STRUCTURE:
Comments
N N/A
ootings ------------ --- —Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Walipour
Reinforcement in Place
Foundation Dampproofing
Foundation /Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width I
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under SIab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Sucliemingway\Building.Codcs.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
ti • Chm &fb``/`
235FII .F COPY
NOTICE Ridge Road
McIntire Queensbury, NY 12804
Dining Room September 2,
KRAFT PAPER INSULATION MUST BE Addition 2004
COVERED BY NON-COMBUSTIBLE RAfl 'rr)
South Elevation By: C. Santa Scale: 1/4" = 1'
NOTICEApproved by: Phil and Rita McIntire
FOAM INSULATION MUST BE COVFPFD
BY A 15 MINUTE THERMAL P ''
LEGEND
RED = EXISTING STRUCTURE
t BLUE = DINING ROOM ADDITION
GREY = SLAB
, 28
_ j=j-6,..____:__------'4---- Length
2 _ /
E E E I
2'-9 1/2"
P : ilWEDF
DATE q .x. .1'-1 1/2" C C
D 3,_2„
11'-6"
i
2'
1 �_ �_ . -
5 1/2'
1 c./_c.11
r
2352 Ridge Road
--', McIntire Queensbury, NY 12804
Dining Room September 2,
�' '�, Addition 2004
`e. North Elevation By: C. Santa Scale: 1/4" = 1'
Approved by: Phil and Rita McIntire
I—— LEGEND
RED = EXISTING STRUCTURE
-HT'
BLUE = DINING ROOM ADDITI❑N
GREY = SLAB
1
// \
8'-7 1/2"
8'-6"
6'-11 1/4"
I
16'-6"
1c1
2352 Ridge Road
McIntire Queensbury, NY 12804
Dining Room September 2,
Addition 2004 '"
LEGEND
1 West Elevation By: C. Santa Scale: 1/4" = 1'
Approved by: Phil and Rita McIntire
RED =
EXISTING
STRUCTURE
_ _
maim—mar•-r'—mom-------rmr. --a---- ---.n MIN---limn aim ill
.NoaiiNossmasiiiaiaINommmmmmmsmmsssmmmmmsaissrmsmaimNossmsNosmmmmmmmmmmm.mmsmI
ME,i.---I----------- ----- -----m B L U E
.mmmmmmmmmlmNos.mmmmmmmmmm.mmm.m.mmmmmmmmm.mm m mm mm...mmm....s...sail -
--m.----------- ---------ms-------m -
in ii =No---in an DINING
NI i
• ROOM
..mama_ NMI 11111111111111E MS=MI IMMO NMI aim own mow am anicimiii ion aim Mimi ism um moil min mi.me mime so
ADDITION
a NB No �s mmm maiel�aim MMMMM IN el r r s r r m m al mMmm. s mmm n Nom am mai al Wm m.rMIli rm Mal. m Mm m ur
n
( _
1 ]
i
2'-11/2,, B 11'-6"
6'-l0 1/2" 11'-1 1/2"
4,-5„ A A A
Q { 1
13'
IA '
•
Wall Cross Section
5/8" ❑SB covered by housewrap and siding to match existing house
'-21 Wall Insulation
6 mil vapor barrier
1/2" Sheetrock
2352 Ridge Road
McIntire Queensbury, NY 12804
Dining Room September 2,
Addition 2004
Cross Sections By: C. Santa Scale: As Drawn
Approved by: Phil and Rita McIntire
Notes
North
1, Slab will be on or above
grade
2. Slab will be reinforced by 2" Foam Edge Insulation
building wire tied to 1/2° rebar retained and capped by PT 2x Material
3, Slab will be pinned to ledge
by anchor and sleeve
5 1/2" rein. thickness slab
2352 Ridge Road
McIntire Queensbury, NY 12804
Dining Room September 2,
Addition 2004
Foundation Plan By: C. Santa Scale: 1/4" = 1'
Approved by: Phil and Rita McIntire
McIntire Addition
Dining Room
2352 Ridge Road
McIntire Queensbury, NY 12804
Dining Room September 2,
Addition 2004
Floor Plan By: C. Santa Scale: 1/4" = 1'
Approved by: Phil and Rita McIntire
•
#--) RECEIVED
FILE COPY -70/16
TOWN OF
u Bu
BUILINi
TT- •
SEP 1 5 2004
CLJt.) vv-i.• L._
LA.,) 227> Lc
-21 tz, CORy
DC A
D DE
BUILDING ; t
Ar 11111111111
Vji r s h
REVIEWED BY „it. KRAFT MIR lauums,MUST BE
DATE AMMil
RI COVERED sy
NON-COMBUST11311 BARRIER
Ridge Ven
Insulation Venting Spacer Foa
5 Year Fiberglass Shingles
R-38 HD Insulatio --3X Skylights Fixed
Grace Ice and Water Shield 2 Row
5/8' OSB with plywood clips
24' DC 2 X 12 Roof Rafter with Hurricane Ties and Teco Nail
2 X 6 Double Top Plat
Soffit Vents
Wood 1/2 X 6 Clapboard
House Wrap
2 X 6 Wall Studding 16 DC
FOAM rNsuutioN MIST BE COVERED
BY A.15 MINUTE DERMAL BARRIE R R-21 HD Wall Insulation
6 Mil Vapor
1/2' Gyp Board on walls and Ceiling
I -
5 1/2' 28001b or better, wire and rebar reinforced Concrete Stab
Foam Insulation For Shallow Foundation Specifications '
4o .3( )
Anchor Bolts installed in Slab to fasten plat d
Door and Window Header Detail 2352 Ridge Road
Queensbury, NY 12804
Header Glued and Nailed McIntire
11 Headers supported with Jack Studs Dining Room September 13,
Addition 2004
2 X • Cross Sections By: C. Santa Scale: As Drawn
1/2' Plywoo.
Approved by: Phil and Rita McIntire
•
• Ridge Vent `ti
-.+.�� Existing her:k; o, f' i'r�c Floor Be= root t
�`i.Ci-�o Cc'Et'�i"x=d rC:ised ridge ('1r?tat Roca ir.o.
Grace :C€' :anal Water S}`IE?tE;t on entire r^of)F
/8' CSB with tom'y wood Glib::
re Engineered Roof' Truss; 7 1i Snow Load — _ _ . __
tit00d .i./C x, 6 ,i(a'pi;JC Ctr-d Siolir'g---- ._ ',
1 } House Wrap i 9{9{9{!
l`. iur"r'Canty Tie with tec.o Naits
2 'Watt S t4.idding 1r'J iOI,.. I f
R HD Glatt insulation
6 tit vapor
Barrier
1/E' Gyp Board or waits Crd veiling I�(
i( i
I ii ti
1/G .:800tb, or better,, w,r._ an r'ebar reinforced Concrete Stab `'_'-p
I
roan fn=.ut.v. ion For hattow r oundo ..ion SpecificaTion: --'
.� '2.. I 0 SC l7) IVy s•.icy Co
'Anchor Botts in statte d ir: Stab to Fasten elate
2352 Ridge Road
McIntire Queensbury, NY 12804
Dining Room September 13,
Addition 2004
Cross Sections By: C. Santo Scale: As Drawn
Rear t evel
Approved by: Phil and Rita McIntire
FOUNDATIONS FIGURE R403.3(1)
INSULATION DETAIL
FLASHING PER SECTION R703.8
INSULATION PROTECTION PER SECTION R403.3.1 SLAB-ON-GROUND FOUNDATION FLOOR
SLOPE FINAL GRADE PER SECTION R403.3. PER SECTIONS R403.1 AND R506
: :°; '///\\\'///
///\\\'///i;*. '•= \\\`///i
////\\\\,; i///\\\,
12IN.MAX. ' r . • \\\`///,
12IN.MIN. ., -•'i///\\\`
1 �: :.• . \\\`///i
o o G
o o //�
\\\`//A /i
( o 0_0 - o O e
///.\\\'///.\\\'///\\"///\\\'///\\\\'///\\\`
NOMINAL 4 IN.SCREENED AND VERTICAL WALL INSULATIONa
WASHED GRAVEL OR CRUSHED
STONE,DRAINED PER SECTION HORIZONTAL INSULATIONa
R403.3.2
HORIZONTAL INSULATION PLAN
._..........____.._..............
L----__________*.
FOUNDATION
PERIMETER
i 1 IIC
For SI:1 inch=25.4 mm.
a. See Table R403.3 for required dimensions and R-values for vertical and horizontal insulation.
FIGURE R403.3(1)
INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
•
RESIDENTIAL CODE OF NEW YORK STATE 63
R403.2-TABLE R403.3 FOUNDATIONS
R403.2 Footings for wood foundations.Footings for wood Materials used below grade for the purpose of insulating
foundations shall be in accordance with Figures R403.1(2)and footings against frost shall be labeled as complying with
R403.1(3).Gravel shall be washed and well graded.The maxi- ASTM C 578.
mum size stone shall not exceed 3/4 inch(19.1 mm). Gravel R4033.1 Protection of horizontal insulation below
shall be free from organic,clayey or silty soils.Sand shall be . gound. Horizontal insulation placed less than 12 inches
coarse,not smaller than /16-inch(1.6 mm)grains and shall be (305 mm)below the ground surface or that portion of hori-
free from organic, clayey or silty soils. Crushed stone shall zontal insulation extending outward more than 24 inches
have a maximum size of 1/2 inch(12.7 mm). (610 mm) from the foundation edge shall be protected
R403.3 Frost protected shallow foundations.For buildings against damage by use of a concrete slab or asphalt paving on
where the monthly mean temperature of the building is main- the ground surface directly above the insulation or by ce-
tained at a minimum of 64°F(18°C),footings are not required mentitious board or plywood rated for below-ground use,di- y
to extend below the frost line when protected from frost by in- rectly above the top surface of the insulation.
sulation in accordance with Figure R403.3(1) and Table R403.3.2 Drainage.Final grade shall be sloped in accor-
R403.3. dance with Section R401.3.In other than Group I Soils,as
Exceptions: detailed in Table R405.1, gravel or crushed stone beneath
1. No foundation not so protected may be attached to horizontal insulation below ground shall drain to daylight or
frost-protected shallow foundations. into an approved sewer system.
2. Unheated garages,porches,utility rooms and carports R403.3.3 Termite damage.The use of foam plastic in areas
shall not be permitted to be attached to dwelling units of"very heavy"termite infestation probability shall be in
with frost-protected shallow foundation. accordance with Section R324.4.
TABLE R403.3
MINIMUM INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
HORIZONTAL INSULATION HORIZONTAL INSULATION DIMENSIONS
PER FIGURE R403.3(1)(inches)
AIR FREEZING INDEX VERTICAL INSULATION R-VALUE°e
(°F-days)b R-VALUEc4 Along walls At corners A B C
1,500 or less 4.5 NR NR NR NR NR
2,000 5.6 NR NR NR NR NR
2,500 6.7 1.7 4.9 12 24 40
3,000 7.8 6.5 8.6 12 24 40
3,500 9.0 8.0 11.2 24 30 60
4,000 10.1 10.5 13.1 24 36 60
For SI: 1 inch=25.4 mm,°C=[(°F)-32]/1.8.
a.Insulation requirements are for protection against frost damage in heated buildings.Greater values may be required to meet energy conservation standards.Inter-
polation between values is permissible.
b.See Figure R403.3(2)for Air Freezing Index values.
c.Insulation materials shall provide the stated minimum R-values under long-term exposure to moist,below-ground conditions in freezing climates.The following
R-values shall be used to determine insulation thicknesses required for this application:Type II expanded polystyrene-2.4R per inch;Type IV extruded polysty-
rene-4.5R per inch;Type VI extruded polystyrene-4.5R per inch;Type IX expanded polystyrene-3.2R per inch;Type X extruded polystyrene-4.5R per
inch.NR denotes"not required."
d.Vertical insulation shall be expanded polystyrene insulation or extruded polystyrene insulation.
e.Horizontal insulation shall be extruded polystyrene insulation.
64 RESIDENTIAL CODE OF NEW YORK STATE
WINDOW SCHEDULE
Job Site/Address: 35.P- -Nte-"--2-c,c c L 12 ��.t-•z 1`1-4 `(� Date: �— 5 �c 1
Owner: U•.c..=,..1-*-+ e._� Application No. I
Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware
Number or Manufaturor Model/Type Stock Openin Opening GlassNis Egress/Cle Opening Opening or Instructions
Letter on Name Numbe g Height ible Vent ar Width In Height
Plan Call Width Light Opening Inches In Inches
Size
PEs.-1 t Pam- 'i ..•�s l�n,�ccg 3 3i It 5?j 37�at
.'T S 1 •11S 3 •1S t o'Z,tJ ii
a Z L,gc.�L .-(4,Sci
'-2-e-t1 Pr A re`-k',` .1)S> . 1to� a' 13//4 1s.%S Opt N/t N/la- N 4 1.-0u G a.1,5
''P'QOL.,..JC 31 0C., e.11 ON 'i>o,.b(•.tin,Q ` / P`1 -Al i yy 6 .WC. 3.25- p.s-- 1 ..(4,1` 14 ii !_otk)ELL . 34
2.e4-t aaa«.T -3)00 2. 3 35 t4:L331/4 `oN. 5 .?,-z, N/P+. Pc R- '— I5 o N 5 ee`s-r�,�+
2-4
- •-1-.1_44 ` e.Yt.b,4f-3(- I 11 % P'1 u 3•4‘1 Nl A Ni/Pc /J/A- N/q Low feu• 3 J
Example Entry
A Andersen Narroline 3062 3' 2 6'5 '/z 15.30 8.36 6.01 34 24 15/35" Tempered
Double 1/3" 11/16 Glazing
Hung
C:\Documents and Settings\Sue\Local Settings\Temp\Window Schedule.doc
(/ 703
• umber
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Co e
Generated by REScheck-Web Software
PROJECT TITLE:McIntire Dining Room
COUNTY:Warren
STATE:New York
HDD: 7635 RECEIVED
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
SEP 8 2004
DATE:09/08/04
DATE OF PLANS:9/02/04 TOWN OF QUEENSBURY
BUILDING AND CODE
PROJECT DESCRIPTION:
14'X 16'6"addition off the north/west corner of an existing single
family home. Intended use of the addition is a dining room.
DESIGNER/CONTRACTOR:
Christopher Santa, 88 Riverside Drive,Saranac Lake,NY 12983 518-
656-9596(job site)518-891-7496 (Home)
COMPLIANCE: Passes
Maximum UA= 104
Your Home UA= 103
1.0%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R Value U-Factor UA
Ceiling 1:Flat or Scissor Truss 91 49.0 0.0 2
Ceiling 2:Cathedral 140 38.0 0.0 3
Skylight 1:Vinyl Frame,2 Pane w/Low-E 12 0.350 4
Wall 1: Wood Frame, 16"o.c. 502 21.0 0.0 25
Door 1: Solid 18 0.200 4
Window 1:Vinyl Frame,2 Pane w/Low-E 53 0.340 18
Floorl:Unheated Slab-On-Grade 61 13.0 47
Insulation depth:2.0'
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the
building plans,specifications,and other calculations submitted with this permit application. The proposed
systems have been designed to meet the New York State Energy Conservation Construction Code
requirements. When a Re ' red Design Prof 'onal has stamped and signed this page,they are attesting
that to the best of ' ow dge,belief,and fessional j ent,such plans or specifications are in
compliance wi this
Builder/Dosi er Dflto 0,
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
Generated by REScheck-Web Software
DATE:09/08/04
PROJECT TITLE: McIntire Dining Room
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Flat or Scissor Truss,R-49.0 cavity insulation
Comments:
[ ] 2. Ceiling 2:Cathedral,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16"o.c.,R-21.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Vinyl Frame,2 Pane w/Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
Skylights:
[ ] 1. Skylight 1:Vinyl Frame,2 Pane w/Low E,U-factor:0.350
For skylights without labeled U factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
Doors:
[ ] 1. Door 1: Solid,U-factor:0.200
Comments:
Floors:
[ ] 1. Floorl:Unheated Slab-On-Grade,2.0' insulation depth,
R-13.0 continuous insulation
Comments:
Slab insulation to extend down from the top of the slab to at least 2.0 ft. OR down to at
least the bottom of the slab then horizontally for a total distance of 2.0 ft.
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in.below grade.
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
[ ] Supply ducts in unconditioned attics or outside the building must be insulated to R 11.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R 6.
[ ] Supply ducts in unconditioned spaces must be insulated to R 11.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R 2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g.(500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ] Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State,the Residential Code of New York State or
the New York City Building Code,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105°F or chilled fluids below 55°F must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. •
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
RECORD OF RESOLUTION-Queensbury Planning Board July 27,2004
Craig MacEwan,Chairman Chris Hunsinger, Secretary
3 Candleberry Drive 7 Meadow Drive
Queensbury,New York 12804 Queensbury,New York 12804
TO: Philip C. &Rita A.McIntire PROJECT FOR: Philip C. &Rita A.McIntire
2352 Ridge Road 2352 Ridge Road
Queensbury,NY 12804
The Queensbury Planning Board has reviewed the following request at the below stated meeting
and has resolved the following:
SITE PLAN REVIEW NO.40-2004,Philip and Rita McIntire
2352 Ridge Road 1.1—
Tax Map No.240.00-1-7 RECEIVED
Meeting Date: Tuesday,July 27,2004
SEP 0 8 2004
SITE PLAN REVIEW NO.40-2004,Philip and Rita McIntire
2352 Ridge Road T BUILDINGN OF QUEE AND CODE QUEENSBURY
Tax Map No.240.00-1-7
RESOLUTION NO. SP 40-2004
INTRODUCED BY: Robert Vollaro
WHO MOVED ITS ADOPTION:
SECONDED BY: Richard Sanford
WHEREAS,an application has been made to this Board for the following:
To add a 231 sq. ft addition to an existing residence located on Route 9L. Expansion of
nonconforming structures in a Critical Environmental Area require site plan review and approval
from the Planning Board.
WHEREAS,the application was received on May 27,2004;and
WHEREAS,the application is supported with all documentation,public comment,and application materials
in file of record;and
WHEREAS,pursuant to Art. 9 of the Zoning Ordinance of the Code of the Town of Queensbury a public
hearing was advertised and was held on July 27, 2004;and
WHEREAS, the Planning Board has determined that the proposal complies with the Site Plan application
requirements of the Code of the Town Queensbury(Zoning);and
WHEREAS,the Planning Board has considered the environmental factors found in the Code of the Town of
Queensbury(Zoning);and
Page 1 of 2
414
1.4
a �Q4 N$9'47 58"E a ► - S83'Q8'Jg"E $ , .x
m 181.33. Emma DECK �I r-_ Q.4B . 0
Q TO 8E REMOVED
q q``_ V
iiii104r
2 PROPOSED +' k
to
DI11ON w
•
�. X 15.5 +�IpVS • ,3 "`mil
144iii.:
r is?.a8 2•1az' tN (
pour N-
•
r e •
/ 1-
e
10 AREAS
•
t 47,110 sq.ft. TANKt
z 1.08 acres ' •
AREA•O - i,
-LEACH MEL / ,,
0 . •
• I
WI
CO CV
O N Q.
• Z '
711
3
I~ / ! 0
o %;n
4�9 t
'�; 6 a
co
0 68 '22., 41.07I ��w 38.56' /
•
—
W S8fi 23 42 7725 DRAT
—
MRE FENCE REMAINS �;P \ 1 'I . . t` Ny 79q.45' ~
Cki
N I /6'f'�1.2pN
1,4
I w
o 1p
-Rv�,\l7
.3
_Z -, L-_,`-\
EVIE WED
DATE
Under la ment 3/4 ' CDX Sub
��i ooring
Mil Vap r Barrier imiiiii
R-19 Anchor Bolts
2 X 8 Floor Jois unfaced
III .• \.\\*,
\\\......
nsulatlon retaining wire
I_,\ Joist Hanger
Flooring Cross Section ouble 2 X 8 plywood center carry beam
North . -
2352 Ridge Road
McIntire Queensbury, NY 12804
Dining Room September 17,
Addition 2004
Amended By: C. Santa Scale: 1/4" = 1'
Foundation Plan
Page 1 Approved by: Phil and Rita McIntire
C
-18
4500 lb. concrete Tooter
3/8" Rebar Pins to Ledge, Epoxy Fastening
6/_7"I 3/8" Rebar tied to rebar pins
North
•
o n o n
_14,_2
Footer 2352 Ridge Road
Cross McIntire Queensbury, NY 12804
Section •: 3/8" Rebar Dining Room
�� Addition September 17,
3/8" Rebar Pin— J\Le•g� 2004
`Epoxy
Amended By: C. Santa Scale: 1/4" = 1'
Foundation Plan
Page 1 Approved by: Phil and Rita McIntire
MAP REFERENCE:
MAP OF C3
DUNHAM'S BAY WETLANDS Iq
z Iq
DATED: NOVEMBER 23, 1974 z N
REVISED: MARCH 1, 1977 0
BY: COULTER & McCORMACK W
a
a 3
R oI
Z LANDS N/F OF
F SAHLKE
0
�PF N89'4758"E N J S83'pg c, [�,
40 58"E
o) 181.33' EXISTING DECK a 80•46' 0
10 TO BE REMOVED \
PROPOSED
W ADDITION O
14' X 16.5' y�V
AL ^ _ ^�
�t
^ SF^ 0) °
co
/ N
/
LANDS OF �` z 61� �'f
STATE OF NEW YORK - 15288•
AL
W ° °
.AL 1N 40 AREA aKf ^N
AL a 47,110 sq.ft, v
2 1.08 acres AREA OF
LEACH FIELD
w
AL 00
� I
AIL
O
z o�
AL
� o 0
z Cl) LEGEND:
�4�96' c OIPF = IRON PIPE FOUND
El CONIC MON = CONCRETE MONUMENT
�6848' 41.07' 38 56
5 = UTILITY POLE
W S86'23'42"W 77? \ oR� = PICKETT FENCE
25 W,� = WIRE FENCE
sllc o^ ���0 O� _
ARE F / •"� r /l
ENCE REMAINS N 79 46, v P� 0 E�
= N76 O�2 OA'W AP lication
2004
LANDS N/F OF
DENTON Zonin Administrator
,TOWN OF 0UEENS8URY
OF RE
21
APPROVED JULY 27, 2004 WITH THE FOLLOWING CONDITIONS:
1. WAIVERS ARE GRANTED FOR STORMWATER, GRADING, LIGHTING AND LANDSCAPING. :
Date: NOV EMBER 18, 1999
uS 'UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY Scale 1'=30'
MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A� �(`n VIOLATION OF SEC 7209,SUB-DIVISION 2,OF THE Map Of a Survey made for
��([�[/� NEW YORK STATE EDUCATION LAW.'
VV S t e v e s MARKONLYED
COPIES ORIROMGINAL
THENAL ORIGINAL OF THIS SURVEY
NARKED NI7M AN OFtIGWAL OF THE LAND SURVEYORS
SEAL SHALL CONSIDERED TO ACCORDANCE VM ,RUE COPIES.' P H I LI P C . M c I N T I R E
'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT
THIS SURVEY WAS PREPARED INLANDSURV WITH THE
L a ri d S u r v e y o r s LANDS CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED
BY THE NEW YOWL STATE ASSOCIATION OF PROFESSIONAL 9— — 4CONDITIONSAPPROVAL
LAND SURVEYORS.SAID CERTIFICATIONS SHALL RUN IkLLY
TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND
ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL 2 4-9-04 ENLARGE ADDITION OF 1
AGENCY AND LENDING INSTITUTION LISTED HEREON,AND Town of Queensbury, Warren County, New York
169 Haviland Road Queensbury, New York 12804 TO THE ASSIGNEES OF THE LENDING INSTITUTION.' 1 4-1-04 PROPOSED ADDITION
McIN11RE C-1231
(518) 792-8474 New York Lic. No. 50135 NO. DATE DESCRIPTION DWG. NO. 99301
21-1-9