Loading...
Signed Inspection Report (07-27-2020) (6).pdfINSPECTION WORKSHEET (FDTN-003805-2020) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0255-2020 Case Module:Permit Inspection Date:Mon Jul 27, 2020 Inspection Status:Partial Pass Inspector:Smith, Mark Inspection Type:Building Foundation Job Address:Parcel Number:12 HALL RD EXT Queensbury, NY, 12804 289.11-1-17 Contact Type Company Name Name Primary Owner Leonardo, Rebecca Engineer VanDeLoo, Walter Applicant Leonardo, Rebecca Contractor Rosewood Home Builders Granted Permission Rosewood Home Builders Primary Owner Leonardo, Adam Applicant Leonardo, Adam Checklist Item Status Building Inspector Notes Failed 7/16/20 footings and 3 piers approved 7/20/20 frost walls approved, provide a stamped updated foundation plan showing the changes made at the frost walls. 7/27/20 foundation walls approved. Provide a stamped updated foundation plan showing the changes at the frost walls. Footings Passed 8" x16" footings approved Piers Passed Jul 27, 2020 Page (1) INSPECTION WORKSHEET (FDTN-003805-2020) Checklist Item Status 24"x 24" x12" piers approved with 2 #4 rebar each direction Monolithic Slab Failed Reinforcement in Place Passed 2 rows of #4 rebar continuous, vertical dowels to be wet set Foundation / Wallpour Passed 7/20/20 frost walls approved, provide a stamped updated foundation plan showing the changes made at the frost walls. 7/27/20 foundation walls approved Reinforcement in Place Passed 7/20/20 frost walls only: one row of # 4 rebar continuous at top of wall. 2 rows of #4 rebar one at top, one at center of wall continuous Masonry Wall Failed Reinforcement in Place Failed Footing Dowels or Keyway in place Passed #4 rebar 48" on center Foundation Dampproofing Failed Foundation Waterproofing Failed Footing Drain Stone - 6 inches above footing Passed Provide stone @ footings as discussed prior to applying footing drain Jul 27, 2020 Page (2) INSPECTION WORKSHEET (FDTN-003805-2020) Checklist Item Status 7/22/20 returned to verify placement of interior and exterior footing drains Footing Drain stone - 6 mil poly Failed Backfill Approval Failed Plumbing Under Slab Failed PVC / Cast / Copper Failed Foundation Insulation Interior / Exterior Failed Verified 2" foam @ interior of frost wall 7/22/20 Rough Grade 6 inch drop within 10 ft.Failed Poly Under Slab Failed Jul 27, 2020 Page (3) Smith, Mark