Signed Inspection Report (07-28-2020) (9).pdfINSPECTION WORKSHEET (FDTN-003815-2020)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0255-2020 Case Module:Permit
Inspection Date:Tue Jul 28, 2020 Inspection Status:Partial Pass
Inspector:Smith, Mark Inspection Type:Building Foundation
Job Address:Parcel Number:12 HALL RD EXT
Queensbury, NY, 12804
289.11-1-17
Contact Type Company Name Name
Applicant Leonardo, Adam
Granted Permission Rosewood Home Builders
Engineer VanDeLoo, Walter
Applicant Leonardo, Rebecca
Primary Owner Leonardo, Rebecca
Primary Owner Leonardo, Adam
Contractor Rosewood Home Builders
Checklist Item Status
Building Inspector Notes Failed
7/16/20 footings and 3 piers approved
7/20/20 frost walls approved, provide a stamped updated foundation plan showing the changes made at the frost
walls.
7/27/20 foundation walls approved. Provide a stamped updated foundation plan showing the changes at the frost
walls.
7/28/20 foundation damp proofing and footing drain approved
Footings Passed
8" x16" footings approved
Jul 28, 2020 Page (1)
INSPECTION WORKSHEET (FDTN-003815-2020)
Checklist Item Status
Piers Passed
24"x 24" x12" piers approved with 2 #4 rebar each direction
Monolithic Slab Failed
Reinforcement in Place Passed
2 rows of #4 rebar continuous, vertical dowels to be wet set
Foundation / Wallpour Passed
7/20/20 frost walls approved, provide a stamped updated foundation plan showing the changes made at the frost
walls.
7/27/20 foundation walls approved
Reinforcement in Place Passed
7/20/20 frost walls only: one row of # 4 rebar continuous at top of wall.
2 rows of #4 rebar one at top, one at center of wall continuous
Masonry Wall Failed
Reinforcement in Place Failed
Footing Dowels or Keyway in place Passed
#4 rebar 48" on center
Foundation Dampproofing Passed
7/28/20
Foundation Waterproofing Failed
Jul 28, 2020 Page (2)
INSPECTION WORKSHEET (FDTN-003815-2020)
Checklist Item Status
Footing Drain Stone - 6 inches above footing Passed
Provide stone @ footings as discussed prior to applying footing drain
7/22/20 returned to verify placement of interior and exterior footing drains
Footing Drain stone - 6 mil poly Failed
Plumbing Under Slab Failed
PVC / Cast / Copper Failed
Foundation Insulation Interior / Exterior Failed
Verified 2" foam @ interior of frost wall 7/22/20
Rough Grade 6 inch drop within 10 ft.Failed
Poly Under Slab Failed
Jul 28, 2020 Page (3)
Smith, Mark