Loading...
2005-074 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CEIR!".r. IFICATE OF OCCUPANCY Permit Number: P20050074 Date Issued. Friday, October 21, 2005 This is to.certify that work requested to be done as shown byPermit Number P20050074 has been completed. Tax Map Number: 523400-301-014-0002-023-000-0000 Location: 60 MC ECHRON Ln Owner: ERIC &LYNN PIESNIKOWSKI Applicant: VASILIOU MICHAEL J INC This structure may be occupied as a: Garage - 2 Cars Attached By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the P Y property owner of the-responsibility for compliance with Site Plan, Variance",'or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050074 Application Number: A20050074 Tax Map No: 523400-301-014-0002-023-000-0000 Permission is hereby granted to: VASILIOU MICHAEL J INC For property located at: 60 MC ECHRON Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction V la ue Owner Address: VASILIOU MICHAEL J INC Garage-2 Cars Attached 14 STONE PINE Ln QUEENSBURY, NY 12804-9068 Single Family Dwelling $300,000.00 Total Value $300,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency VASILIOU MICHAEL J INC 14 STONE PINE Ln QUEENSBURY, NY 12804-0000 Plans&Specifications 2005-074 LOT 11 HSE #60 MCECHRON LANE 2943 SQ FT SINGLE FAMILY DWELLING $423.66 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, February 23, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Q nsb ff February 23, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. " No inspection will be made until applicant has received a Fee Paid valid building permit. All applicants' spaces on this Rec.Fee Paid $ application must be completed and must appear on the Reviewed By: IT application form. Applicant: �i !�lWEL iL/axed,.Owner: Address: 4ei',,7E Z4. Address: QGtEEY293300Cy��I/ Phone#CS_/8)) 79e- 92 2 Phone Email Address: Email Address: Property Location: Lot Number: / House Number 0,,V f,,An Subdivision Name: 77/,t G Z D Y,E- Tax Map Number:3d/. I Y- -'R --:;L3 add 8 UD °r� New Building: residence commercial Estimated Market Value of Construction: $ i ❑ Addition: residence/ commercial If an Addition,what will use of new addition be? ❑ Alteration: residence/ commercial ❑ No change to exterior size: residence/com'l ❑ Other work(describe ) Check Occupancylnformation I't Floor 21d Floor Other floor Total Below sq.ft. sq.ft. sq.ft, Square Feet J<� 3, if," Single family dwelling f S7 . 4 ,,3 ❑ Two family dwelling - ❑ Townhouse ❑ Multifamily dwelling #of units ❑ Office ❑ Mercantile ❑ Manufacturing /T ❑ 1 car detached garage U 010( 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage 2 car attached garage s' 0 3 car attached garage ❑ Storage building- commercial ❑ Storage building- residential ❑ Other What is the proposed height of the structure Cl feet inches Will any second-hand or ungraded lumber be used? If so,for what? /Vp Type of Heating System: electric/ oil /l.✓'" wood /forced hot air/ baseboard/othet: Number of Fireplaces to be installed O Number of Moodstoves to be installed G� List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder .4.4>41 A S�-o ���r- 9 Plumber i& Z9e y3�7� Mason ee- 4�� - A-5- l Electrician 6kEn P" ,*7 ill L LE /®��—LT 91 Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survev by a licensed surveyor;drawn to scale,showing actual location of all nrw construction. Signature: owner's"agent,architect,contractor Application for Permit—Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: }.............._......_.............._........................_.....__.._.._---........................_...._.._..., Office Use j Location of installation: ,o r// t D z�I�PD�'I�. File Permit No. / Tax Map No.SQ// ' / �23 ° Owner's Name: AX Y. �4�fL/fG( r ................_.._............................... Z17, J Address: �� 97^Di'� �`'>1? C:YSB K ' 'Y 2. INSTALLER'S NAME /`��/��[/� �x 0 /1X�//16' P (5NENO. 71 Pen_ 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate 4 bedroom(s) and multiply# of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No of Be&_q=s x Commutation = Total Daily Flow 1980 or older x . 150 gal/bdrm = 1980—1991 x 130 gal/bdrm = 1991 —present y x 110 gal/bdrm = 31e Garbage Grinder Installed yes / no ✓ Spa or Whirlpool Installed yes_ / no ✓ 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) SoiLNzture Ground Water Bedrock or Irwervious Material Domestic Water Flat s t what depth at what depth rdci a u Rolling cam > 7feet 2� feet wel Steep slope clay d n if well;water supply _%slope other from any septic-system depth: DG{�'t't_ZS p absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate:I n i S'gjgute per inch 5. PROPOSED SYSTEM: For New ConoVoga: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: Z-?.Sd g on (min. size 1,000 gal.) ,57 Tile Field: each trench ft Total System Length: fi Seepage Pit(s): number of size of each: ft, by fl. Size of Stone to be used: # / depth or thickness feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-2.9 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an.applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensb Sanitary Sewage Disposal Ordinance. r Signature of respo sli a person Date 'li�tvtt of t,j leellsi ur-y �tetivct•;t :tntl �c�v:r1•�. I)+�j:<►;;:tl t:lt:t�:tt•t• SPA"A ltA'1'ION ItI.C�t!I iti,tll l�:N'1`5 n r.P0ND t ./ V/F-L[_ IN //►TA t f- tt'�v J .taut CJISt�iC; .���... .•- . .� 1-4 150u.lc G CIE IPjye . I 1. .� � •'• Sct•t1c. �,y � M l+jy�+tntf'11at 1 f`I Ci4.p 7. SIGNATURE &INFORMATION FOR Kh llu14b xsL.rr rr,"wi, �.��.......:; Check Residential Plan Review: One& Two Family Dwellings Y/N/N/A; (2)FulI sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size i Door Schedule/Main Entrance 36"Door mergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor esidential Check Paperwork Compliance and Inspectors Checklist: OK 3wnpproofmg/Waterproofing Materials On Plans Fo dation Drainage On Plans,if required Drop in 10' Exterior Grade Fra 'ng Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where aired ce Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width 11 Stair Run and Rise /V-A Winder Run and Rise Wk 1 iral Not Allowed From 2 Story oke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. andrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. fety Glazing Notes For Required Areas Gdra Fire Separation arage Floor Sloped Vf Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed ,Fee Worksheet: Single-Family Dwelling TO --- Are. R9cr�ation Fees applicable to this permit? ye s no If in a subdivision, check with Subdivision Maps in file drawer to see if Recreation Fees are applicable (there will be a stamp on the map) Also, ask Zoning Office and/or Planning Office staff. Subdivision Name: �"0�'_ Lot No. House No. &6 Road Name:'/ue__ =c_ L 1 st Floor sq. ft. 7 x .012 cents / sq. ft. _ 2nd Floor sq.-ft. 3 x 0.12 cents/sq. ft. _ garage sq. ft. d x 0.10 cents/sq. ft. - 70, cSO fireplace how many? U x $25 /fireplace (application is receipt-Fire Marshal) Recreation Fee if applicable 500 = �� pp $ (separate receipt-Planning/Zoning) Total Fee for collection $ �3 Need 2 survey plot plans drawn to scale showing setbacks. New construction: be sure applicant signs the septic stamp Need 2 copies of REScheck (energy code) Need 2 sets of building plans. Check for signatures on all applicable spaces. ENERGY CODE COMPLIANCE APPLICATION ..- TOWN OF QUEENSBURY, WARREN COUNTY � I 9000 HEATING DEGREE DAYS(Z)w r ;; Compliance Methods:Part 5 -Acceptable Practice Method— 1&2 Family Dwellings (oiil.') Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwe ing; u Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance, Commercial Buildings-Hi Rise Residential *Requires submission of worksheets AyyPyyPLICANT'FNAME: PROPERTY LOCATION: .4y'1L�DG� PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area 7 P-7 square feet r 2. Type of heat- Electric Oil Gas Other 3. Is building mechanically cooled? yes No 4. Percentage of area of windows and doors Over 17% Under 17% 5. R-VALUES FOR INSULATION GIVEN BELOW MUST-CORRESPOND TOR VALUES AS , SHOWN ON PLANS SUBMITTED: a. Roof R 3� b. Exterior walls R_� � C. Glazed areas R 3.2 d. Exterior doors R_/__8�_ e. Floors over unheated spaces R_S;ZL f. Edge of slab on grade(heated building) R ' g. Basement/cellar walls (above grade) R__ h. Basement/cellar walls(below grade) R i. Heating/cooling-ducts-piping in unheated space RZV 6. Service (domestic)hot water heating device Conforms to minimum efficiency per code 1/Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED p 'cant's Sign t Date Phone Number INSPECTOR'S REMARKS: Queensbury Building & Code Enforcement - Residential nal nspection Office No.(518)761-8256 Arrive: pm, am/pm Date Inspection request received: Inspector's Initi s: f `1 NAME: �'`\,� �(.� -�, IT LOCATION: 0 ATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location �� r Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios ��� 1 s Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in,(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer DeRVInspectiow6ticker Flood Plain Certificatio re uir Okay to issue C/C o /Q4ymporary ermane L:\PamW\Buildint;&Codes\Inspection Forms\Res. Final Inst). form 2.docLast vrinted 2/12/04 VWQueensbury Building & Code Enforcement - R4sidenFinal Inspection �Office No. (518)761-8256Arrive: am m/pm Date Inspection request received: Inspector's Initials: 1 NAME: � PE IT#: �� np7q LOCATION: D E: TYPE OF STRUCTURE: y Comments Y N N/A Chimne Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/z" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: ! Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches _ Garage Floor Pitched Garage fireproofing/'/,hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification,if required --fl Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insv. form 2.docLast printed 2/12/04 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: '7 - Z p-jp5- NAME: V)61 LA bu LOCATION: 1po IMCEcNk--,� E PERMIT#: 2,pp,;T —O"7 Final Survey Plot Plan Avvroved. Denied The attached final survey has been received by the / Dept.of Community Development. Upon revi the . survey en: Cr �n,Zoning Administrator Notes: L:\.SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc .e C' j(AGlW'C A3 PTR YAP RBFTR 0-8 22 10 MAP REFERENCE: THE GROVE SUBDIVISION DATED NOVEMBER 6, 2000 �,�►��� /'�► LAST REVISED MARCH 3, 2001 BY VAN DUSEN & STEVES LAND SURVEYORS, LLC LANE % �o�s - 0 0® .0 o / . 0, h N 1.250 GAL. 5EPTIG TANK 4GA D15TRIBUTION BOX 12 0�/ A135ORPTION TRENCHE 5 / 13 5 a 44" EA. 11 61,1471 sq. fto 1.41 acres �M 0 `.� �pS Wtlgi'�,Q.�%�% °dh A CJl 177048' SEPTIC SYSTEM - AS BUILT SOB°45'54'W DoteiJULY 21, 2005 •�..({ a D u s e vNADTfi0R1'hD ALMOMTOH OR AMMON TO A suRvfl� Map of a Survey made for Scale 1'=30' MAP BEAFMOO Or A CDO 72 LAND9.31 -01MDRS SEA{.6 A v � NOIA710N OF SECTiDN 7208.SVB-pN510N 2 OF THE HEN corm STATE EDUCATION LAW. "ONLY COPIES FwN THE OWMAL GF THIS SIIRYEY MAa�D wTH AN OR MAL OF THE LAND SURVnM eves SHALL BE CONSIDERED - LYNN PIESNIKOWSKI S- 1 GE ,MD A,EQH�H�CEWTH ERIC A THIS SURVkY WAS PREPARED DI ACCORDANCE wTN THE Land Survey ors EM�G CODE OF SAW CO FOR�D ONLY �,�.,�, BY THE NEW YOrm STATE ASSOOATION OF MWESSMAL LAUD SURNE70R5.SAO C8iTlriGtliONS SHALL RUN p4Y TO THE PERSON FOR*"7NE"%EY IS PREPARED.ANO ON k115 am" TO 7NE riLE CC//PANY,OOMERN►ffNTA1 169 Haviland Road Queensbury, New York 12804 "`� A"°`E"`"�°""�"°'�"A"° Town �f Queensbury, Warren County, New York lO THE ASSIGNEES OF THE IENOmG NSDiUiK7N.' PIE5NJK0 (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO.85418-11 ACE ENGINEERING, 1 169 Haviland Road, Queensbury, NY 12804 Phone-518-745-4400 Fax -518-792-8511 � July 21, 2005 ffY �_j Job #46143 New York State Dept. of Health 77 Mohican Street JUL Glens Falls, NY 12801 .t , y RE: Lot#11 (#60 McEchron Lane) Emerald Grove Subdivision- Queensbury(T) �� Gentlemen: This letter is to inform you that I inspected the completed septic system for the house on Lot #11 in the Emerald Grove Subdivision on July 20 & 21, 2004. The house constructed on this lot is a 4 bedroom house. The septic system as installed consists of a 1,250 gallon septic tank and 220 lineal feet of absorption trench. The installation conforms with the requirements of the approved subdivision design drawings. Attached is an As-Built diagram of the septic system for your files. Please call me if you have any questions or concerns. Sincerely, Thomas W. Nace, P.E. cc: Dave Hatin, Town of Queensbury Michael Vasiliou Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re est r eive Z Queensbury Building &Code Enforcement Arrive: a p Depart: a in 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: I!A S PERMIT#: 0 S — 0-7 L LOCATION: LCI (,,o ►vN C 0 .! c-,^ INSPECT ON: TYPE OF STRUCTURE: Dec _ Comments —-- Y -T N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement I of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab — Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. 1.:\SueHemingway\13uilding.Codes,Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 V11 Queensbury Building & Code Enforcement - Reside l ' al Inspectio Office No.(518)761-8256 / Arrive: = e �j �aP +J� Date Inspection request received: 7 1' }X� Inspector's Initials: \A 'n 0 C— NAME: ` IT#: 6 S-67�{ i LOCATION: ATE: TYPE OF STRUCTURE: __ Comments Y N N/A L Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more a,stairs,decks atios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more ��PLET'C ` A Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. ��� Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall W\O'DO V VA 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above rade Gas Furnace shut-off within 30 ft.or within line of site �� �LL �t�N , Oil Furnace shut-off at entrance to furnace area �:1 l— Furnace/Hot Water Heater operating l � O 1� ps - u Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 FLoO� © � %] Interior privacy/trim/doors/main entrance 36 in. 1r t Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detgtrtors: Every level: ✓✓ / Every Be oom: Outside every bedro7 area: Inter Connected: / Batter backup- Carbon Monoxide Detector Bathroom Fans, if.no window ID � �` 6 � Plumbingfixtures o►a�, LA Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 s . ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if re ui Oka to issue C/C or C/Oijerriporaryjhrmarient L:\PamW\Building&Codes\Insvection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 JUL-21-05 FRI 09 :99 BOB FLANSBURG _-,- 5185818079 P. 01 � ♦ Y A C ES Architecture with a new Point of view. AL July 21,2005 Mr.John O'Brien,Building Inspector Town of Queensbury 742 Bay Road Queensbury,N.Y. 12804 Re: Piesn"wski Residence Builder_Michael J Vasilou Builders,Inc. Dear Mr. O%ien, Please note that a triple 18-wircollam was placed on top of the rear family room wall. This microllwn ztivxs all the way from the right exterior wall to the beginning of the angled bay burlap-out. This was a decision trade by the framer.Please note tj at although this beam was unneccesaly.1 have no parobleta with it being left in place as is. Sitndatly,the (3) 2 x 10's beam over the entrance hall was continued to the right exterior wall of the living room. This flush beaA also serves as a header over the W-W Opening into the Living Room. As a result of the two beaxns mentioned above please note that tine £loon joists iA between these beans are hung from joist hangers on both ends. Please note that I alai aware of this situation and dad it to be acceptable. I would respectfully request that retain this letter in your files and considex it an addendum to the plans submitted to your office for a building permit If you should have any questions regarding this infox-nxation, please do not hesitate to contact me at(518) 581-8079. W,t-41e- Robert L.Flansburg,EE- ti 0� Robert"Flansburg,P, 6 Meghan Court Saratoga Springs,NY 12666 518.581.8079 fax 518.581.2649 A& �Iw Queensbury Building & Code Enforcement - si en a Final Inspection Office No.(518)761-8256 J / Arrive: am/p part: m/ Date Inspection request received: 7 l�/ �� Inspector's Initia NAME: 1 D-V - 7� P IT#: �S 7 LOCATION: Af C - E: -_ TYPE OF STRUCTURE: Comments n�[� Y N N/A Q SAP C Chimne y Ht./"B"Vent/Direct Vent Location �l Fresh Air Intake 0 FI R � 10t EC 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Co m lete 1 Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. 1-..e, C3Eww Platform at all exterior doors vUr- Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/2" Gypsum Grade away from fit ndation 6 in.with 10 ft. 'Rw � �-APW- f)��a Handrail Tertnina' at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above gradep - - Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. t t Bathroom/Kitchen watertight 7 C ' �., Safety glazing/Wind w in stairwells safety glazing Interior Smoke Dete ors: L Every level: _ / Every Be oom: � O�J Outside every bedroo rea: Inter Connected: / Batter backup: ff Carbon Monoxide Detector � F 101� ►�'� (�1�C� ooav Bathroom Fans,if.no window "A Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf --C-Q Emergency egress below grade �P Basement stairs closed rise>4 inches _ no Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer 41 FV-- , Duct work Sealed properly K'�-U�` 1. Gas Logs in Sealed or Glass Enclosure �qsb"To Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical O�j Site Plan /Variance required F�VA I k) Final Survey Plot Plan (f—V-N\b iWbkz7 -b As Built Septic System/Sewer Dept.Inspection Sticker ©� � Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Buildinfz&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.Q Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No........................................Cert. N 0 9 0 10 1 Cut-in Card No.................................... :)wner.........C-' �t S IV i kow"S'r J ......._.............................................................................................................................................. e � tc ocahon..4:0.......�g....' Fti Iv .(�tGGo instal ation Consistin of................................. . .,... - ... A--...... , :s.T......... I .......... C,. .f . .................................................................................................................................................................................. InstalledBy..... ...................................................Lic.No.................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued i ;ancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the ntroduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making ' s coons at any time, and if its ules are violated,the Company shall have the right t r ke this rti cate. L 3ate...... ..�z:� WSJ....... INSPECTOR......................... Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reque r c e : _ Queensbury Building & Code Enforcement Arrive: a /p epart: am p 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: PERMI #: 7c-)c>h—r�1�A LOCATION: I i1 Mc, Lkr.*-. INSPE ON: <T-2 --t �- TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head NP.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: _ LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reques a eive . Queensbury Building & Code Enforcement Arrive: a /pm art: -r a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: ����`�� c; PER I #: Q� LOCATION: il-�TT Ac`n INSPECT ON: - TYPE OF STRUCTURE: Y N NIA Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 5 P.S.I for 15 minutes �o sulation Residential Check/ Commercial Check C Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: Q C� RP �Tc�pS V—: 1A k,)v �6v\eFmoLV- �bT Fta a G 01'j--'F F Li K-� E JD tJ 1 v,7y)�- oL Lo C FAP-FCAU-U F-0� Q u:�) R t-i K)c�6 -1�6 0 RE- T-EQ T7� LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 / 0-/j Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request ce d: Queensbury Building & Code Enforcement Arrive: a /pm D art: - a p]�5 742 Bay Road, Queensbury, NY 12804 Inspector's Initial - NAME: L Mk PER T #: LOCATION: INSPECT ON: 5=17- C)S TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air Head ,.-�X,/ P.S.I for 15 minutes r sulation Residential Check Commercial Check / b Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces r,1/dam Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS• \ LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,200 \ �_ >�b � t_4�') k Framing / Firestopping Inspection Re o Office No. (518) 761-8256 Date Inspection r quest r ceiv'd: Queensbury Building & Code Enforcement Arrive: _ m/pm part: am n 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: /P,)jI C-,ILL PERMIT#: LOCATION: (c,c� Mc._Ec_LA Rc*� L PwF= INSPECT ON: TYPE OF STRUCTURE.- I Y N A Framing COMMENTS Jack Studs/Heade s _ Bracing/Bridging Joist hangers SET l%F h- iM G7 P i�fj Jack Posts/Main Beams Exterior sheeting nailed properly ✓ �'� ���JC-�L��t L Ll�l�jv��� 12"O.C. Headroom 6 ft. 8 in. ��� \�` -� L1✓p Firms �QAN1 ti Stairwells 36 in. or more _ .T_, �� Headroom 6 ft. 8 in. ``� �- � � Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate _ 1 %s (w) 16 gauge(8) 16D nails each side 10_)O , i{TF_ ,hT Draft stopping 1,000 sq. ft. floor trusses Z t��) Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall ire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping /D MG Penetration sealed Va� 16 inch insulation in cavity min. yi (Zi u3� t`�ttJ\ l� TrD Garage Fire Separation House side % inch or 5/8 inch Type X �J Garage side 5/8 inch Type X � M\Ceiling/wall I Windows Habitable Space/Bedrooms ✓ 24 in. (H) 20 in. (W) ✓/ 5.7 sf above/below grade ✓/ �`� �" 5.0sfgradeP\Goo .✓ �t�r�jj �F MiCUlt�ta ������ C=L0o� — F t e c 6z- ")AT►c L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2 3 w'A Lt_ ���� _' �ft =� ►'�'��'\e�fix � , Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection req t re ed• _ Queensbury Building & Code Enforcement Arrive: am/p epart: r)r 742 Bay Road, Queensbury, NY 12804 Inspector's Ini , / NAME: �l Sl [-1 J)A P IT #: 2oa5--0 74 LOCATION: t-00 Nw-- sue INSPECT ON: S- a5 TYPE OF STRUCTURE: S � Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction r Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation Residential Check / Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodeAnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspe on Report Office No. (518) 761-8256 Date Inspection requ t ei Queensbury Building&Code Enforcement Arrive: p Depart: m 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: �,(�1,� ERMIT #: fur=6]} LOCATION: INSPECT ON: TYPE OF STRUCTURE: h �� Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates t�.�Tf►i` iAu_ �,�(_ 1 % inch min.Drain Size L L 1 U'�V VcV--. Washin Machine D inch min. Head or MESiinnly Tnet j Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November l7,2003 -Z-- 1 ti Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection reque ei �51 it os- Queensbury Building& Code Enforcement Arrive: a pm e �ar 742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: V-�jl (_16u PERMIT#: 2,WS-CJ7 LOCATION: CPO IfuC'tC-tF2zy"1 INSPECT ON: - Q TYPE OF STRUCTURE: Y N /A Framing COMMENTS Jack Studs/Headers Bracing/Bridging - C'%}f_�- Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly (J G� ��� \ 7C� 12"O.C. Headroom 6 ft. 8 more Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls c�T Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side \%��- _C_\z_. — Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping 7 ��� Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemin-way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 29,2003 Framing / FirestoPP g in Inspection Re ort P P Office No. (518) 761-8256 Date Inspection eques ecei ed: Queensbury Building& Code Enforcement Arrive: am/p apart: a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Init Is: NAME: U �� �' i� PERMIT#: 0 LOCATION: {'C1 C FC,h ,-�, �, A; o INSPECT ON: 1.4 C, TYPE OF STRUCTURE: Framing Y N N/A COMMENTS ' Jack Studs/Headers Bracing/Bridging 1;7,�J tJ5— Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. `� �V�� Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %i (w) 16 gauge(8) 16D nails each side p ,� c-p O E-z—:�;>L Draft stopping 1,000 sq. ft. floor trusses F-N F- Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3, 4 hour restopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection req est received: �] Q Queensbury Building& Code Enforcement Arrive: a m D part: pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial : r' NAME: V'15��'U PERMIT#: �i 7 LOCATION: (l �C1 r ,-t ��, INSPECT ON: /f TYPE OF STM JCTUR-t: Y N N/A Framin COMMENTS Jack Studs/Headers i Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wail Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.inspection.FORM STraming Firestopping Inspection Report.doc January 29,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: i Queensbury Building& Code Enforcement Arrive: —am/ p art: am/pmP 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: i NAME: PERMIT#: LOCATION: 1 — r INSPECT ON: � TYPE OF STRUCTURE: Y N N/A COMMENTS \A. raming � Jack Studs/Headers ^11� Bracing/Bridging Joist hangers Jack Posts/Main Beams �- 7 mil) ( ej Exterior sheeting nailed properly 12"O.C. A-LeS Headroom 6 ft. 8 in. Z Stairwells 36 in. or more s ' ,�/ ���� Headroom 6 ft. 8 in. / �(�� .— p C� ( �- Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate ��� 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: 1:_ 5�&Tp Queensbury Building& Code Enforcement Arrive: a epart:742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: Lt C PERMIT#: S,. v 7. LOCATION: V L ( — INSPECT ON: -0S TYPE OF STRUCTURE: �F p Cj Y N N/A 1COMI F mg Jack Studs/Headers Y� ` Bracing/Bridging I `>L V G "" O U T �C� ��'�S 7- Joist hangers FL-2 Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. I �0�.` I d� �-S S AT Stairwells 36 in. or more I Headroom 6 ft. 8 in. G o a . Akc/4 Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses (� _ Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHerningway\13uiIding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: c ,, Queensbury Building& Code Enforcement Arrive: am/ epart:—� m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: V U ( PERMIT#: i LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS �rs 0 /Headersg/Bridging Joist hangers Jack Posts/Main Beams G C� ���` U Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. 1 t"h — d 0 T A&c Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls 73 Metal Strapping for Notches Top Plate �� 1 %s (w) 16 gauge(8) 16D nails each side v (� tTf f-t Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour (� � �4f,{ Firestopping + �( Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHerningway\Building.Codes.Inspection.FORMSTFraming Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection reque t received: Queensbury Building& Code Enforcement Arrive: am/p part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ( PERMIT#: �— 07 �1 LOCATION: ti — 6^% LAj INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging C; Joist hangers Jack Posts;Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour O U-1 Firestopping Penetration sealed KAA W qo 6W (::Ik 16 inch insulation in cavity min. r °` Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report C- x�/ Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: _am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: V 1�-`— I NAME: PERMIT#: � LOCATION- INSPECT ON: - 11�111 TYPE OF STRUCTU 1�� Framing Y N N/A COMMENTS Jack Studs/Headers c, Bracing/Bridging / Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses An or Bolts 6 ft. or less on center ce and snow shield 24 inches from wall 6 �Q•D Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) j 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\BuiIding.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report _ Office No. (518) 761-8256 Date Inspection que t rec Queensbury Building& Code Enforcement Arrive: _ am/p� art: a 742 Bay Road, Queensbury, NY 12804 Inspector's Initi$lsl - NAME: VOLSi PERMIT#: O� O LOCATION: C - INSPECT ON: (}� TYPE OF STRUCT RE: � Y N N/A _ COMMENTS aming 1h� � >� r Jack Studs/Headers � Bracing/Bridging ,AC, Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s (w) 16 gauge (8) 16D nails each side � � \7 t7L�� Lj_ ` , Draft stopping 1,000 sq. ft. floor trusses L, Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping 1. Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X �� Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) I 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Septic Inspection Report Office No.(518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a m depart am/pm 742 Bay Rd.,Que nsbury,NY 12804 Inspector's Initials NAME: PERMIT NO.N LOCATION: INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water J C Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total len h ft. Length of each trench $, Depth of trenches ft, Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Siz -Type Building to tank G Tank to Distribution Box Distribution Bo Field/Pit Opening Seale4l Y W Partial End Caps Location/Separations Foundation to tank ft. Foundation to abso !ion ft. Separation of Pits ft. Conforms as per Plot Plan Y N Engineer R ort and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Fron iddle Rear S stem Use Sta s- Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 1/6/05 Septic Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a m part: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: \1 PERMIT NO.: 3 o os "7 LOCATION: ' un�,,a„INSPECT ON: RECHECK: C Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone ize: 4' in Size Type Buildin to tank / Tank to Distribution Box stribution Box to Field/Pit 'Opening Sealed: Y/N/Partial End Caps r Location/Separations Foundation to tank ft. U(�, Foundation to absqEption ft. �7 Separation of Pits ft. Conforms as per Plot Plan Y N Engineer Report and As-Built Y NA- Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear ✓ `� System Use Status: Appro ^ �� 1—"4 ��KGCK /�f' P al Approved and needs to be re-inspected,please call the Building&Codes Office isapproved Last revised 1/6/05 z -71 L 1 0 �►� Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: l� Queensbury Building&Code Enforcement Arrive: a` part: pm 3 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: /�r-�J/ NAME: 5`' �"T �1,� PERMIT NO.: LOCATION: t j( D. Ln INSPECT ON: -31 171 0-� RECHECK: Comments and/or diagram Soil T Sa / m/Clay T e of ater: unici /Well Water Waterline sepa&4@trTjstance ft. Well separation distance _ ft. Other wells: ft. Absorption Field: Total length Length of each trench ft. Depth of trenches ft. Size of Stone See age Pits: Number �(G Size: x -- Stone Size: 4-ex— Piping Siz Type Building to tank e;�> D Tank to Distribution x Vjlfi� Distribution Box to Fig Pit q Opening Sealed: Y Vj Partial r,>oe- LocationEnd Ca e '��G-/Separations Foundation to tank ft. Foundation to absorption Separation of Pits 7 ft. Co UCR- l G' Conforms as per Plot Plan Y N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: proved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 1/6/05 Foundation Inspection Report Office No. (518)761-8256 Date Inspection re st e iv Queensbury Building &Code Enforcement Arrive: nv'p i Depart: 742 Bay Rd., Queensbury, NY 12804 Inspector's Ini ial - NAME: 91- ERMIT#: LOCATION: rV�`-' INSPECT ON: 3 O TYPE OF STRUCTURE: _ v Comment _ V N N/A Footings Piers T Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing \ Foundation/Waterproofing -TTpe of DampproofingY Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing t areas under slab eR-a—ckfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. I.�SueHemingway\Building.Codes.Inspec tionTORMSToundation Inspection Ruport.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re e r eiv 3 Queensbury Building &Code Enforcement Arrive: a L Depa an 742 Bay Rd., Queensbury, NY 12804 Inspector's Initial . 6OS -67� NAME: — RMIT#: _ LOCATION:� L — .— PECT ON: J TYPE OF STRUCTURE: Comments Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. 1.,:1SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 l�1 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request recev ed: Queensbury Building &Code Enforcement Arrive: am/ Depart a `pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: ��`Tl ` v PERMIT#: LOCATION: SPECT ON: a a� TYPE OF STRUCTURE: Comments Y N N/A *iers gs Monolithic Slab Reinforcement in Place The contractor is responsible for provi ing protection from freezing f 8 hours following the placement t` A-faterials the concrete. for this purpose on site. Foundation/Wallpour 100 Reinforcement in Place ' Voor Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval i Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L\SueHemingway\Building.Codes.InspectionTORMSWoundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: / Queensbury Building& Code Enforcement Arrive: am/OF �iDepart: A m 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: _ y�"5 l 1--1 a (� PERMIT#: _._v � O LOCATION: ?-1 t2o tit �1 _ INSPECT ON: ���? S TYPE OF STRUCTURE: Comments Footings ----------------------------- Piers Monolithic Slab Reinforcement in Place V, i The contractor is responsible fo providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation W/ allpour Reinforcement in Place Foundation Dampprooting Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil.poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior!Exterior R- Rough Grade 6 inch drop within 10 ft. 1,:\SueHemingway\Building.Codes.inspection.PORMS\Foundation Inspection Report.doc January 28,2003 0607q Permit Number REScheck Compliance Certificate Checke y/Date 4^ New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release le �l Data filename:CAProgram Files\Check\REScheck\Piesnikowski.rck PROJECT TITLE:Piesnikowski Residence COUNTY:Warren STATE:New York HDD: 7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:02/11/05 DATE OF PLANS:2/11/05 DESIGNER/CONTRACTOR: Michael J.Vasiou,Inc Dreamspapes Unlimited COMPLIANCE:Passes Maximum UA=672 Your Home UA=499 25.7%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1610 38.0 0.0 48 Wall 1: Wood Frame, 16"o.c. 135 21.0 0.0 6 Window 1:Wood Frame:Double Pane with Low-E 14 0.350 5 Window 2:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 2: Wood Frame, 16"o.c. 30 21.0 0.0 2 Wall 3: Wood Frame, 16"o.c. 98 21.0 0.0 4 Door 1: Solid 35 0.400 14 Wall 4: Wood Frame, 16"o.c. 30 21.0 0.0 2 Wall 5: Wood Frame, 16"o.c. 133 21.0 0.0 6 Window 3:Wood Frame:Double Pane with Low-E 14 0.350 5 Window 4:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 6:Wood Frame, 16" o.c. 327 21.0 0.0 17 Window 5:Wood Frame:Double Pane with Low-E 14 0.350 5 Window 6:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 7:Wood Frame, 16" o.c. 255 21.0 0.0 10 Window 7:Wood Frame:Double Pane with Low-E 82 0.350 29 Wall 8:Wood Frame, 16"o.c. 26 21.0 0.0 1 Window 8:Wood Frame:Double Pane with Low-E 8 0.350 3 Wall 9: Wood Frame, 16" o.c. 50 21.0 0.0 2 Window 9:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 10:Wood Frame, 16"o.c. 26 21.0 0.0 1 Window 10:Wood Frame:Double Pane with Low-E 8 0.350 3 Wall 11: Wood Frame, 16" o.c. 27 21.0 0.0 2 Wall 12: Wood Frame, 16" o.c. 30 21.0 0.0 2 Wall 13:Wood Frame, 16" o.c. 271 21.0 0.0 15 Window 11:Wood Frame:Double Pane with Low-E 7 0.350 2 Window 12:Wood Frame:Double Pane with Low-E 7 0.350 2 Wall 14:Wood Frame, 16"o.c. 71 21.0 0.0 3 Window 13:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 15:Wood Frame, 16" o.c. 268 21.0 0.0 14 Door 2: Solid 21 0.400 8 Wall 16:Wood Frame, 16"o.c. 223 21.0 0.0 13 Wall 17:Wood Frame, 16"o.c. 172 21.0 0.0 7 Window 14:Wood Frame:Double Pane with Low-E 14 0.350 5 Window 15:Wood Frame:Double Pane with Low-E 14 0.350 5 Window 16:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 18: Wood Frame, 16"o.c. 27 21.0 0.0 2 Wall 19: Wood Frame, 16"o.c. 88 21.0 0.0 4 Window 17:Wood Frame:Double Pane with Low-E 26 0.350 9 Wall 20: Wood Frame, 16"o.c. 27 21.0 0.0 2 Wall 21: Wood Frame, 16"o.c. 120 21.0 0.0 5 Window 18:Wood Frame:Double Pane with Low-E 14 0.350 5 Window 19:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 22:Wood Frame, 16" o.c. 294 21.0 0.0 15 Window 20:Wood Frame:Double Pane with Low-E 14 0.350 5 Window 21:Wood Frame:Double Pane with Low-E 5 0.350 2 Window 22:Wood Frame:Double Pane with Low-E 14 0.350 5 Wall 23: Wood Frame, 16" o.c. 334 21.0 0.0 15 Window 23:Wood Frame:Double Pane with Low-E 29 0.350 10 Window 24:Wood Frame:Double Pane with Low-E 29 0.350 10 Window 25:Wood Frame:Double Pane with Low-E 16 0.350 6 Wall 24: Wood Frame, 16"o.c. 27 21.0 0.0 2 Wall 25:Wood Frame, 16"o.c. 45 21.0 0.0 3 Wall 26: Wood Frame, 16"o.c. 268 21.0 0.0 15 Window 26:Wood Frame:Double Pane with Low-E 7 0.350 2 Basement Wall 1: Solid Concrete or Masonry 1714 11.0 0.0 106 Wall height: 8.5' Depth below grade: 7.5' Insulation depth: 8.5' Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. f Builder/Designer Date / U z REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release le DATE: 02/11/05 PROJECT TITLE:Piesnikowski Residence Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 2. Wall 2:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 3. Wall 3:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 4. Wall 4:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 5. Wall 5:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 6. Wall 6:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 7. Wall 7:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 8. Wall 8:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 9. Wall 9:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 10. Wall 10:Wood Frame, 16" o.c.,R-21.0 cavity insulation Comments: [ ] 11. Wall 11:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 12. Wall 12:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 13. Wall 13:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 14. Wall 14:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 15. Wall 15:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 16. Wall 16:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 17. Wall 17:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 18. Wall 18:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 19. Wall 19:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 20. Wall 20:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 21. Wall 21:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: . [ ] 22. Wall 22:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 23. Wall 23:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 24. Wall 24: Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 25. Wall 25:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 26. Wall 26:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry,8.5'ht/7.5'bg/8.5'insul, R-11.0 cavity insulation Comments: Windows: [ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 2. Window 2:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ )No Comments: [ ] 3. Window 3:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 4. Window 4:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 5. Window 5:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 6. Window 6:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 7. Window 7:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 8. Window 8:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 9. Window 9:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 10. Window 10:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 11. Window 11:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: • #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 12. Window 12:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 13. Window 13:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ J 14. Window 14:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 15. Window 15:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?( ]Yes[ )No Comments: [ ] 16. Window 16:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 17. Window 17:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 18. Window 18:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 19. Window 19:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 20. Window 20:Wood Framebouble Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 21. Window 21:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ )No Comments: [ ] 22. Window 22:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 23. Window 23:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ) 24. Window 24:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 25. Window 25:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 26. Window 26:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Solid,U-factor: 0.400 Comments: [ ] 2. Door 2: Solid,U-factor: 0.400 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Cod e of New York State,the Residential Code of New York State or r the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25' 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2 Runouts 1" and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)