Loading...
2005-079 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20050079 Date Issued: Tuesday, February 21, 2006 This is to certify that work requested to be done as shown by Permit Number P20050079 has been completed. Tax Map Number: 523400-308-007-0001-013-000-0000 Location: 15 WOODSHIRE Ct Owner: SCOTT & AMY SUE LONG Applicant: THOMAS FARONE & SONS INC. This structure may be occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050079 Application Number: A20050079 Tax Map No: 523400-308-007-0001-013-000-0000 Permission is hereby granted to: TIIOMAS FARONF. & SONS INC For property located at: 15 WOODSHIRE Ct in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: TRA-TOM DEVELOPMENT, INC. Fireplace 667 STATE ROUTE 9 Garage-2 Cars Attached GANSEVOORT, NY 12831-0000 Single Family Dwelling $306,000.00 Total Value $306,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency FARONE CONSTRUCTION PO BOX 804 ROT 1TE 9 GANSEVOORT- NY 12831 Plans&Specifications 2005-079 LOT 34 HSE#15 WOODSHIRE CT 3062 SQ FT SINGLE FAMILY DWELLING $415.84 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, March 11, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T of Quee bury; Oor* ay, March 11, 2005 SIGNED BY for the Town of Queensbury. Director of Buildi Enforcement Permit No () 1 Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid L 742 Bay Road,Queensbury,NY 12804 Dave Hatin,DirectorL.Q-d--e nsbury.net Recreation Fee Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure BuildingPermit Application Application & Plans subject to review before issuance of a valid permit for construction Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder �1rYY, >� � ��;� Owner: = Address: Address: Home Phone: ��� `� - �S L Home Phone: Email Address: Email Address: Cell Phone: Cell Phone: FAX Phone: 3 FAX Phone: Person responsible for supervision of work with respect to building and codes compliance:S Name: Ll � c Le-'n Address: Phone Location of proposed construction: Lot No. �� Legal Address: Tax Map Number: Subdivision Name: Estimated Cost of Construction: $ �� C)QU Proposed construction is for: L%'�esidential Use _Commercial Use I Name of Business: If proposed construction is an addition,what will use of new addition be? New Addition Alteration Proposed Construction 1A Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ff. Sq.Ft. Square feet Height Ft.&In. Sinqle-Family Dwelling3 —. Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 14 2 3 rype of Heating System: Electric, Oil(- Wood, Forced Hot- Aires Baseboard, Other: If a fireplace and/or woodstove are being installed, please refer to a separate application. Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy,or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a. licensed surveyor, drawn to scale,showing actual location of all new construction. Date: ` ` Applicant/Builder Signature*"-- -"L- �� _1(16 the application of dot d is hereby approved and permission granted for th c struction, reconstruction r altera on a di / d or accessory structure as set forth above. Date: �� d Authorized Signature: L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 Check Residential Plan Review: One& Two Family Dwellings Y/N/N/A 2)Full sets of plans Over 1,500 sq. 11.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: inflow Schedule With Glass Size 13 r Schedule/Main Entrance 36"Door /,/Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans F dation Drainage On Plans,if required 6"Drop in 10, Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2d Story moke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance I�Yall Width,36"min. andrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation \/ �Garage Floor Sloped V�Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed ' Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to sp6t appliances n Date i IQ 20 _ Permit No. _)AN Application is hereby made to the n God• Q r or the issuance of a Building and Use Permit pursuant to the New York State Fir g Code. The applicant or owner agrees to comply with all applicable laws, U14d,all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: Stove: wood coal pellet gas Fireplace insert Address: Fireplace, factory-built: wood Fireplace, masonry: wood gas : ace: wood gas oil Phone: ,< E If non-masonary applicance,please provide 1ii0 Owner: Mtfacturer Name: Address: Number: Chimney Information Phone: (circle appropriate words) fit ) Masonry block brick stone 7 Flue the steel size: inches Exact Address: I I O Od Nkk k- ,L4 tA:� of construction or Installation Factory-Built Manufacturer name: J11 Model Number: Note: Listed By: Number: Construction/Installation must conform to NYS Fire Prevention &Building Indicate(circle)chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Double wail I Triple wall / Insulated / Cirect venting Chimney Liner � CJaw�teu-'ter Z7ep�rtm�t--To�rss.of Qax�gbury, .ATo�Yorl� 1 Fire Marshal Code# $Collected •S Refunded Received from(refunded to): address: A 173 3389 (190) Public Safety A 233 2655 (230)Minor Sales _! ytAlblt�tNLo— row" VWEw 82 D-P--•2 White(Applicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) / PinkO&Goldenrod(Cashier's Dept.) Application for Permit-Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: ............................................................................................................................... Office Use Location of installation: Tax Map No. : File Permit No. 7 Owner's Name: Fee Paid Address: C; .SC ............................................................................................................................. 2. INSTALLER'S NAME : — fir' r C-� PHONE NO. — �> 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply #of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Dail Flow low 1980 or older x 150 gal/bdrm = 1980- 1991 x 130 gal/bdrm = 1991 -present x 110 gal/bdrm = } U� Garbage Grinder Installed yes _ / no Spa or Hot Tub Installed yes / no 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) Tmo-araDhySoil Nature Ground Water Bedrock or impervious Material es is er So ply Flat sand at what depth at what depth municipal oZring loam feet feet we Steep slope clay if well; water supply i%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: gallon (min. size 1,000 gal) Tile Field: each trench ft. Total System Length: Seepage Pit(s): number of size of each: -- ft. by ft. Size of Stone to be used: # / depth or thickness - feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons !TOTAL Capacity:_ gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. c` Yignature of responsple person t Date 't ntivn ni tZw-witsbury Sc�lvt:t•� sttttl 4�wsi�!e Disposal t:Itstjtirr A1 pmulix t. /1•i�a`•►t)IZ�''•1'x�1�`d I�'11�,1,I.) SPA)ARN11ON It1:t�1,111tIahl i+�IV'I' • of ~ wr f POND Y'/ELt- IN •t�ur ................ r ` rl lt•rM.1 . f I C"IL r ' • �,,..r...+►----- •....«-----•^-""'mow 7. SIGW,A'T'URE &INFORMATION FOlL YVNbWL.�rzr ovi-4 wwAa,."" , BLDG. PERMIT NO. 2 U 0 5-0 7 9 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at; 15 Wood hi&e Ct. for the following uses S'.;-nateF rr1 1 a y v,� DATE SIGNATURE OF PPLI ANT i TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF OCCUPANCY is hereby ( )APPROVED ( )DISAPPROVED with the following conditions: CeAt-i6"aAe of oi,-cupanc.y %�.o be =,S&ued( upon -offp.6&won off.1 ikPP'LOVCt oA Apea Va- utnz..e. TEMPORARY CERTIFICATE OF OCCUPANC E )$1 0 EP 0.00 received on �,Janua -q 3 20U6 t Date of Issuance Director of Bldg. & Code Enforcement THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES 90 DAYS FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcement or his designee. Fee Worksheet: Single-Family Dwelling C� Are Recreation Fees applicable to this permit? yes no / If in a subdivision, check with Subdivision Maps in file drawer to see if Recreation Fees are applicable (there will be a stamp on the map) Also, ask Zoning Office and/or Planning Office staff. Subdivision Name: l- ( L-k& 6 "'__ -� i Lot No. 3q House No. /J Road Name: ; �1�;r� 1 St Floor sq. ft. x .012 cents / sq. ft. �y 2nd Floor sq. ft. 3 5 ,�, x 0.12 cents/sq. ft. _ garage sq. ft.—_—_x 0.10 cents/sq. ft. fireplace how many? _ x $25 /fireplace = .S (application is receipt-Fire Marshal) 333 3 C C� Recreation Fee if applicable $500 (separate receipt-Planning/Zoning) Total Fee for collection $ �— c L/ �a Need 2 survey plot plans drawn to scale showing setbacks. New construction: be sure applicant signs the septic stamp Need 2 copies of REScheck (energy code) Need 2 sets of building plans. Check for signatures on all applicable spaces. 0 4s'5 TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 5 l 8-761-8201 r December 28, 2005 Thomas J. Farone 804 Rte 9 Genasevoort, NY 12831 Re: Building Permit No: 2005-079 15 Woodshire Court Scott C. & Amysue Long Dear Mr. Farone: I am writing to you with regards to the above referenced final survey that was submitted to us on your behalf. I have reviewed your final survey and find that your as built location of your home does not comply with the requirements of the Town of Queensbury Zoning Ordinance. Therefore, you will need to pursue an Area Variance application with the Town of Queensbury Zoning Board of Appeals before we can close out your Building Permit for you. Specifically, your survey depicts a 28.05 ff. front yard setback while the Town Code requires a minimum 30 ft. front yard setback. Your Certificate of Occupancy cannot be further reviewed until these matters have been resolved. Please note the January 17, 2006 deadline for submission of the necessary Area Variance application in order for your request to be heard in February by the Zoning Board of Appeals. Should you have any questions, comments or additional information that might alter this determination, please do not hesitate to contact this office. I am enclosing the necessary Area Variance application for your convenience. Sinc rely, Tow Queensbury Craig town, Zoning Administrator CB/sh L:\Craig Brown\2005 letters\2005-079 Farone Building Permit 12_28_05.doc "HOME OF NATURAL BEAUTY . . . A GOOD PLACE TO LIVE" SETTLED 1763 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm)a D?part: _ am/pm Date Inspection request received: Inspector's Initials: �1�� C_NAME: ag,0/L PERMIT#: ©4� 79 LOCATION: [ eyzhn Z—�� 'j', DATE: t'Z t TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batterybackup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum''/2'Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.In ect' n Sticker Site Plan /Variance required 2 I/V 04, Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection S Office No. (518)761-8256 Arrive: �� am/p epart: am/pm Date Inspection request received: Inspecto sr" Initials: NAME: PERMIT#: LOCATION: U DATE: - TYPE OF STRUCTURE: / Comments Ye No N/A Building Number/Address visible from road ChimneyHeight/"B"Vent/Direct Vent Location'r L G Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches �C Roof Complete/Exterior Finish Complete Platform at all exterior doors 4�__._..__---_.._.._-.-------------- Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: / Outside every bedroom area: V Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fire roofin /%hour fire door/door closer Duct work Sealed prop l Gas Logs in Sealed or asFjEnS ure- Final Electrical Final Surve Plot P an As Built Se Dept.Inspection Sticker Site Plan Variance required Alt � � ����� Flood Plain C�rtilcat� Okayu �Tem �orPermanent ' to 0 L:\Building&Codes des\Inspection orms\Residential inal Inspection Form revised_100405.doc Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Insuection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or spec3�icationais low /n, Permit# (� 7 Schedule Inspection a� /T e am pm anytime Inspector Name Address C oagh h Finaj Appliance Manufacturer_ _ _ Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wail Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) WMte—"Ming Dept. Yeu— r Ph*—Rare Mar" Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm �Deparrt: am/pm Date Inspection request received: Inspector's Initials: ___I (,?— NAME: 01�� PERMIT#: 0!��07 LOCATION: /-5 ��jn i C�� DATE: � O _ TYPE OF STRUC R // _ Co�hments _ Y N N/A ,, C Chimney Ht./"B"Vent/Direct Vent Location S .�`C � , Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Co m lete Guard 30 in.or more @ stairs,decks, atios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/2" Gypsum _ Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing,/'/4 hour fire door/door closer Duct work Seated properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\lnsvection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 N Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: NAME: LOCATION: PERMIT#: Final Survey Plot Plan A roved Denied The attached final survey has been received by the Dept.of Community Development. Upon review the survey been: ()UO Cr ' wn,Zoning Administrator Notes: 0 "Ott L:LSueHemingway%uilding.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc MAP REFERENCE: SUBDIVISION PLAN RICHARD P. SCHERMERHORN C DATED: FEBRUARY 11, 2003 t1► LAST REVISED: MARCH 17, 2004 LOT 35 BY: VAN DUSEN & STEVES A�; gspti O fro e h• � S6 4 P 2 3o0rd� 0 o LOT 34 0.65 acres �� ° oR 28,302 sq.ft. a DO �� 0 �S S RECEIVE TOWN OF QUE URY ZONING OF LOT 33 LOT 24 i C. Q- Dates D EM 6, 2005 '"""�'°�°AL,ERATION"`A°°�'�"'°"Slxs�r Scale 1'=20' an u 's MAP A LW SE&"A Map of a Survey made for & IA«ATDrt OF ,Tom - z OF WE wex YORK SFATE MtKATIOw ur.• *OWY ownwJ&S wi"AN OO ERE T liE WD SURYEY0fl4 � ro�YA� SCOTT C. & AMYSUE LONG '4AWICAMM DOM7 D FE]I M SMFY THAT AZOPTED THS O CO was PRO-PRAk I�u" LAW SURVEYORS YOR THE Land Surveyors °�'°`�� �"TM CK& BY O S R*-YOPoC STATE ASSOCIATWI 6 Prt°FES D&Y IAND 91R1EYORS SAD CER1iiLAlIWS"iAll RU/OlY TO T"E PERSON FOR WOW M SURVEY IS PREPARED.AM UU11 t S'1ff:7 1 OF 1 ow m KKw m T"E m z cAw my-oo1EJ"wff& AGEW169 Haviland Road Queensbu New York 12804 TO W SN `PESO°N51R/O ` SMU"I"." ""° Town of Queensbury, Warren County, New York r3'• ro,"E A59piFES OF,II"u>a�c EeT„u,Iew.• FARONf (516) 792-6474 New York Lie. No. 50135 1 NO. DATE DESCRIPTION DWG. NO. 02342-34 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: ' Queensbury Building&Code Enforcement Arrive: am/p � - art: pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: _ESE dJ61- PERMIT NO.: LOCATION: 7 INSPECT ON: /7215 RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Cap* Location/Separations Foundation to tank ft. Foundation to absorption A. Separation of Pits ft. Conforms as per Plot Plan N En 'neer Report and As-Built VY N ��� ��/� O Aj /6,6— Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Statu Approved Partial Approved and needs to be re-inspected,please call the Building& Codes Office Disapproved Last revised 1/6/05 NUV 29 2005 3: 02PM HP LASERJET 3200 P. 5 169 Haviland Road, Queensbury, NY 12804 Phone-518-745-4400 Fax -518-792-8511 November 29,2005 Job#46175 New York State Dept. of Health 77 Mohican Street Glens Falls,NY 12801 RE: Indian Ridge Subdivision - Queensbury (T) 15 Woodshire Court (Lot#34) - Septic System Dear Sir/Ma'am: This letter is to inform you that I inspected the completed septic system for the house on Woodshire Court(Lot#34)in the Pine Ridge Subdivision on August 8, 2005. The septic system as installed was for a four bedroom house and consisted of a 1,250 gallon septic tank and 220 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, Thomas R. Center Jr. , PE cc: Dave Hatin, Town of Queensbury Tom Farone 'n Framing /Firestopping Inspection Report I �Z Office No.(518) 761-8256 Date Inspectiouest received: a Queensbury Building&Code Enforcement Arrive: " ?iJam/p //�� art: am/pm 742 Bay Road,Queensbury,NY 12804 Inspect is Initials: Zf�t l NAME: `-'�'�' PERMIT#: )3 LOCATION: INSPECT ON: v TYPE OF STRUCTURE: Y N N/A COMMENTS Framing � (I U(2-5 Attic Access 22"x 30"minimums Jack Studs/Headers Bracing/Bridging GM„ �/►� ��'g"��`2"5 Joist hangers Jack Posts/Main BeamsG_ �� Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'h w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.(W) 5.7 sf above/below grade 5.0 sf grade F Rough Plumbing / Insulation Inspection Rep 'rt Office No. (518) 761-8256 Date Inspection request received: —�r�- Queensbury Building & Code Enforcement Arrive: am/pXeparrtt/ V/ am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: A GC INSPECT ON: I�\ j TYPE OF STRUCTURE: c, Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head P.S.I for 15 minutes ,vInsulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p, part: /S am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. NAME: ct�c PERMIT #: LOCATION: X INSPECT ON: TYPE OF STRUCTURE: Rough Plumbing Nail Plates Y N N/A Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 .I for 15 minutes sulation Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Framing/ Firestopping Inspection Report .....:.:.. .:...... Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ m Depart: m 742 Bay Road, Queensbury,NY 12804 Inspector's Initials NAME: _ PERMIT#: U r — U 7 c LOCATION: 5 U) (j S h t t P C �✓ INSP TON: 3 (�S r TYPE OF STRUCTURE: rang Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2,3 hour e wall 2, 3,4 hour Pe ne a ion sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Town of Queensbury Fire Marshal CL 742 Bay Road ;f Queensbury,NY 12804 761-8205/761-8206 fax 7454437 Factor y Bui as ' e la /Stove Ins ecti n Re ort � Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. 0 Permit# () Schedule Inspection 3 Time C am pm anytime Inspecto JosName tN"�_` Address f S w C,o ,.5 �4 Ci, L-y- 1 Rough lax—Final Appliance Mane cturer. �- Model#! `wV U" Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Riestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White—Bandin;Dept Ye3low r Pink—Fire Marshal _ ' f Septic Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: anvp a art: J-7 aiVvm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: l NAME: PERMIT NO.: _ 0 7 LOCATION: �`�� �� _< (�,( INSPECT ON: RECHECK: Comments and/or diazram Soil Type: San / o )Clay Type of Wa er: unicip 1/Well Water Waterline separation4istance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches 7i ft. Size of Stone �Y Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank n Tank to Distribution Box -150 Distribution Box field/Pit OpeningSealed /N/Partial End Ca s Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. At7._ Qvl c—T Conforms as per Plot Plan Y Engineer Report and As-Built Y VN �- Location of Sys on Property: Front ear Left Side Right Side Middle Front Middle Rear 6( ( 6) C 6 V6K System Use Status: pproved artial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 116105 , ti pp Epp �ryh 2�r�2�8.� 3 PROPOSED HOUSE r LOT 34 u 0.65 acres r� 28,302 sq.ft. AROp 'SW- SFA OSF� M Ti0 � E� c p0. c i LOT 33 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 3 G S Queensbury Building & Code Enforcement Arrive: am/p part: am/p 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. ' NAME: q�oAe- PERMIT #: o-Z�5 0 7q LOCATION: PSOdd,-ski'-e— C71. INSPECT ON: <dlV TYPE OF STRUCTURE: i Y N /A Rou h Plumbin ail Plates m Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction res ure Test � 7 � r� a / Vent VSA;rHead.I. or 10 ft. above highest connection for 15 minutes P ure Test F50 r Supply Piping Head .S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Foundation Inspection Report a--� Office No. (518) 761-8256 Date Ins ection reque cei ed: Queensbury Building &Code Enforcement Arrive: °OD a Depart: _ a in 742 Bay Rd.,Queensbury, NY 12804 Inspector's Initia NAME: ` — IT#: T 0 _ 79 LOCATION: 7 SPECT ON: _ TYPE OF STRUCTURE: Comments --__� Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: _ 1,Z inch width inches above footing 6 mil poly for wet areas under slab Backfill Approval i ' mbing Under Slab VC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.InspectionTORM SToundation Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/c „Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: (lam r y NAME: bt,l f— PERMIT#: � G 7� LOCATION: IS,- ( ->P=!5 K 46— `3' INSPECT ON: TYPE OF STRUCTURE: Framing Y N NSA COMMENTS Jack Studs/Headers Bracing t Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall I Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade !_:\SueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report 9 s 1 Office No. (518) 761-8256 Date Inspection request received: II _ Queensbury Building& Code Enforcement Arrive: _am/p &epart' pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: (}` PERMIT#: ' �� LOCATION: INSPECT ON: —/ (p Q JC TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses I Ancff Bolts 6 ft. or less on center Vol-- elk 1�)V e and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X i Ceiling/wall I Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHerning\vay\Building.Codes.Inspection_FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopprng Inspection Report >� Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/ epart: L am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#: a5 LOCATION: 4 INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate _ 1 '/2 (w) 16 gauge (8) 16D nails each side 601� Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center e and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall I Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf Eade LASueHemingway\Building.Codes.Inspection.FORM STraming Firestopping Inspection Report.doc January 28,2003 / --3 1 Foundation Inspection Report p P Office No. (518) 761-8256 Date Inspection request received: V, Queensbury Building&Code Enforcement Arrive: a Depart• am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initi s: / NAME: PERMIT#: OS ' LOCATION: _� �� �_�_ INSPECT ON: — TYPE OF STRUCTURE: Comments Y N N/A Footings Piers +� Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Fo ndation/Wallpour enforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing F ting Drain Daylight or Sump noting Drain Stone: 12 inch width 6 inches above footing 6 tnil poly for wet areas under slab fill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. Lc\SueHemingway\Building.Codes.InspectionTORM SToundation Inspection Report.doc January 28,2003 1 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Lth/QS^ Queensbury Building &Code Enforcement Arrive: am/p Depart: 5amr'pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: c�'-� _ PERMIT#: _&�_ LOCATION: �Jc��l OSI���t�l INSPECT ON: TYPE OF STRUCTURE: Comments _ Y N NIA Footings Piers Monolithic Slab enforcement in Place The contractor is responsible for providing protection from freezing r 48 hours following the placement of the concrete. Materials for this purpose on s Foundation/Wallpour tJ?_:;j Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. LASueHemingway'Ouilding.Codes.Ins pectionTORMSToundation Inspection Repod.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection reAlest�reecceiveed: Queensbury Building &Code Enforcement Arrive: a Depa rrv'pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initia NAME: PERMIT#: C)Dc- V 7 LOCATION: INSPECT ON: _ TYPE OF STRUCT RE: � Comments Y N N/A F ings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing T Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L\SueHemingwaylBuilding.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 Data filename: C:\Program Files\Check\REScheck\2729-02 STONEBRIDGE-FARONE-LOT 34 WOODSHIRE COURT, QUEENSBURY.rck TITLE:PLAN NO.2729-02 STONEBRIDGE COUNTY:Warren STATE:New York HDD: 7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:02/07/05 DATE OF PLANS:FERRUARY 7,2005 PROJECT INFORMATION: TC THOMAS J. FARONE AND SON LOT 34 WOODSHIRE COURT QUEENSBURY,NEW YORK COMPANY INFORMATION: WILLIAMS& WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS,NEW YORK 12801 COMPLIANCE:Passes Maximum UA=589 Your Home UA=451 23.4%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1719 30.0 0.0 60 Wall 1: Wood Frame, 16"o.c. 1455 19.0 0.0 70 Window 1: Vinyl Frame:Double Pane with Low-E 189 0.320 60 Door 1:Glass 42 0.330 14 Door 2: Solid 21 0.130 3 Door 3: Solid 35 0.130 5 Wall 2:Wood Frame, 16" o.c. 1622 19.0 0.0 97 Window 2: Vinyl Frame:Double Pane with Low-E 180 0.320 58 Basement Wall 1: Solid Concrete or Masonry 1265 11.0 0.0 87 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Y Door 4: Solid 21 0.130 3 Floor 1: All-Wood Joist/Truss:Over Outside Air 78 19.0 0.0 4 Furnace I: Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Consery tion Construction Code requirements. When a Registered Design Professional has stamped and signed this page,I i re attest g that t e est of his/her knowledge,belief,and professional judgment,such plans or specifications are i_ co plianc w th th s ' esigner Date 'n i t' REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 DATE:02/07/05 TITLE: PLAN NO.2729-02 STONEBRIDGE Bldg. Dept. Use { Ceilings: [ ] { 1. Ceiling 1: Flat Ceiling or Scissor Truss,R-30.0 cavity insulation { Comments: { Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c.,R-19.0 cavity insulation { Comments: [ ] 2. Wail 2: Wood Frame, 16"o.c.,R-19.0 cavity insulation { Comments: { Basement Walls: [ ] { 1. Basement Wall 1: Solid Concrete or Masonry, 8.0'ht/6.0'bg/8.0'insul, R-11.0 cavity insulation { Comments: { { Windows: [ } 1. Window 1:Vinyl Frame:Double Pane with Low-E,U-factor: 0.320 { For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ] Yes [ ]No } Comments: [ ] { 2. Window 2:Vinyl Frame:Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No { Comments: { Doors: [ ] { 1. Door 1:Glass, U-factor:0.330 Comments: [ ] { 2. Door 2: Solid,U-factor:0.130 { Comments: [ ] { 3. Door 3: Solid,U-factor:0.130 { Comments: [ ] 4. Door 4: Solid,U-factor:0.130 Comments: Floors: [ } 1. Floor 1:All-Wood Joist/Truss:Over Outside Air,R-19.0 cavity insulation { Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: [ J I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ J I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly I with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a { 3" clearance from insulation. { Vapor Retarder: [ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ } I Manufacturer manuals for all installed heating and cooling equipment and service water heating I equipment must be provided. [ ] I Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ } { Supply ducts in unconditioned spaces must be insulated to R-11. [ } I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. { Insulation is not required on return ducts in basements. i I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts I operating at less than 2 in.w.g.(500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] { The HVAC system must provide a means for balancing air and water systems. I I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space I temperature set point of the largest zone. I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. I I Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction { provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code ,as applicable. 1 Service Water Heating: [ ] { Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ } I Insulate circulating hot water pipes to the levels in Table 1. I i Circulating Hot Water Systems: [ ] ( Insulate circulating hot water pipes to the levels in Table 1. I i Swimming Pools: [ } I All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock_ Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature( F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2" Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)