Loading...
PTI-003099-2020 06292020INSPECTION WORKSHEET (PTI-003099-2020) Case Number:PT-0336-2020Case Module:Permit Management Inspection Date:06/29/2020Inspection Status:Failed Inspector:John O'BrienInspection Type:Property Transfer Inspections Job Address:349 Cleverdale Rd Parcel Number:226.12-1-49 Queensbury, NY 12804 Contact TypeCompany NameName ApplicantMary E. O'Brien Revocable Trust Checklist ItemPassedComments WatertightFalse Building Inspector NotesFalse Weather/lack of information/inaccessibilityFalse Service contract (required)False Holding tank (if yes, include capacity)False Capacity in gallonsTrue1000 System/components indicate unacceptableFalse Is there a high water alarm?False Roof gutters don't discharge over leach fieldFalse Concrete tankTrue Temperature (Fahrenheit)False80 D-box materialTrue Apparent structural damageFalse Visible scum layerTrueNo. Tank pump one month ago Septic tank (include # of tanks)True1 Number of tank compartmentsFalse Plumbing fixtures tested & confirmedFalse Evidence of a pipe bypassing tankTrueNo Holding Tank:verify level risescap. w/in 250 galFalse Metal septic or leech tank or cesspoolFalse Whirlpool tub add 250 galTrue System appears undersized/undersized componentsFalse Foundation drain(s)False Verify 50% & 90% floatsFalse Is there evidence of surface water infiltratingFalse StormwaterFalse Is septic tank sized for bdrms+whirlpool+grinderTrue1000 Garbage grinder add 250 galFalse Tank coverTrue System appears to have functioned adequatelyFalse System passes all function testingFalse Outlet pipe (automatic failure, if yes)False Metal tank (automatic failure)False Does the pump(s) appear to be operating properly?True July 30, 2020Page 1 of 3 INSPECTION WORKSHEET (PTI-003099-2020) Checklist ItemPassedComments Surface discharge? (if yes, to where?)False Roof runoffFalse System needs repairsFalse Sump pump not connected to septic systemFalse Sand filterFalse Leaching bedFalse Outflow line invert above leach line invert(s)?TrueNo Overflow pipe (automatic failure)False Depth below grade to top of tankTrue12" to 18" Evidence of prolonged high liquid levelFalse Access riser? (if yes, depth to cover)TrueSuggest risers on tank and d box covers CesspoolFalse OtherFalse Is tank pumped more than 4x/year?TrueNo Mound systemFalse Outlet baffleTrue Absorption fieldTrueOk Number of drop box(es)TrueNone ManufacturerFalse Excavate 18" around,no leach field connectedFalse Inlet baffleFalse Water softener not hooked to septic systemFalse OtherFalse Evidence of liquid above outlet inverts?TrueNo Plastic tankFalse Water tight tankTrue Ejector or grinder pump sealedFalse ModelFalse Leaking water fixturesFalseNo Aerobic systemFalse On-site as-built req'd before insp is completeFalse Dosing or pump tank sealedFalse Cracked, corroded or deformed?False Test each fixture flow to septic tankTrue Are both switch and alarm operable?False No treatment tank/other critical component(s)False Cracked, corroded or deformed?TrueNo Are there any obvious electrical shortcomings?False Main tank cleanout size and locationTrue12 X 18" OtherFalse Raised systemFalse OtherFalse July 30, 2020Page 2 of 3 INSPECTION WORKSHEET (PTI-003099-2020) Checklist ItemPassedComments Solids in D-boxTrueNo Sump pump(s)False Seepage Pits: NumberFalse Liquid level AT/ABOVE/BELOW (one) discharge invertTrue TypeFalse As-built provided is accurateFalse WeatherFalseStormy Recommend upgrade/expand/replace 1+ componentsFalse July 30, 2020Page 3 of 3