ResCheck Generated by REScheck-Web Software w w
CD
w
Compliance Certificate a al in
BE C E 0 \LIE "--` r.z.. cro, .
Project Garage Remodel SUN 25 QO x a 0
i fa RP
Energy Code: 2018 IECC --•
Location: Warren County, New York TOWN OF QUEENSBURY 5
BUILDING&CODES
Construction Type: Single-family n
Project Type: Alteration 0
Climate Zone: 6 (8499 HDD) W
Permit Date: N N
Permit Number: N N
O
Construction Site: Owner/Agent: Designer/Contractor: �. NC
320 Ridge Road
Queensbury, NY 12804
ompliance: Passes using prescriptive requirements for alteration projects
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling: Cathedral Ceiling (no attic) 400 42.0 0.0 0.025 10
Wall: Wood Frame, 16" o.c. 243 40.0 0.0 0.043 10
Window 2: Vinyl Frame 4 0.200 1
Window 1: Vinyl Frame 11 0.200 2
Wall 1: Wood Frame, 16" o.c. 147 40.0 0.0 0.043 6
Door: Solid Door(under 50% glazing) 18 0.100 2
Wall 2: Wood Frame, 16" o.c. 147 40.0 0.0 0.043 6
Wall 3: Wood Frame, 16" o.c. 264 40.0 0.0 0.043 11
Floor: All-Wood joist/Truss 264 30.0 0.0 0.033 9
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
RESc`hey Version : REScheck-Web and to comply with the mandatory re firemen ' ted in the REScheck Inspection Checklist.
Name-Title Signature Date
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 1 of 9
REScheck Software VersionChecklist: REScheck-Web
Energy Code: 2018 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal [Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. [Not Observable
Systems serving multiple ENot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ['Not Observable
Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 2 of 9
Section
Foundation Inspection Complies? Comments/Assumptions
& Re..ID _
303.2.1 A protective covering is installed to EComplies
[FO11]z protect exposed exterior insulation ❑Does Not
and extends a minimum of 6 in. below
[Not Observable
grade.
ElNot Applicable
403.9 Snow-and ice-melting system controls ❑Complies
[FO12]2 installed. Does Not
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- EComplies See the Envelope Assemblies
402.3.4 EDoes Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- EComplies See the Envelope Assemblies
402.3.1, average). EDoes Not table for values.
402.3.3,
402.5 ❑Not Observable
[FR2]1 ENot Applicable
t
303.1.3 U-factors of fenestration products EComplies
[FR4]1 are determined in accordance EDoes Not
with the NFRC test procedure or
taken from the default table. [Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier EComplies
[FR23]1 installed per manufacturer's EDoes Not
instructions.
['Not Observable
ENot Applicable
402.4.3 Fenestration that is not site built EComplies
[FR2O]1 is listed and labeled as meeting EDoes Not
AAMA/WDMA/CSA 101/1.5.2/A440
or has infiltration rates per NFRC ['Not Observable
400 that do not exceed code ENot Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures EComplies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ['Not Observable
❑Not Applicable
403.3.1 Supply and return ducts in attics EComplies
[FR12P insulated >= R-8 where duct is EDoes Not
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and [Not Observable
return ducts in other portions of ENot Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.2 Ducts, air handlers and filter EComplies
[FR13]1 boxes are sealed with EDoes Not
joints/seams compliant with
International Mechanical Code or ['Not Observable
International Residential Code, as ENot Applicable
applicable.
403.3.5 Building cavities are not used as EComplies
[FR15]3 ducts or plenums. EDoes Not
ENot Observable
ENot Applicable
403.4 HVAC piping conveying fluids R- R- EComplies
[FR17]2 above 105 °F or chilled fluids EDoes Not
below 55°F are insulated to
3 ❑Not Observable
ENot Applicable
403.4.1 Protection of insulation on HVAC EComplies
[FR24]1 piping. EDoes Not
❑Not Observable
ENot Applicable
403.5.3 Hot water pipes are insulated to R- R- EComplies
[FR18]2 >_R 3. EDoes Not
ENot Observable
ENot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 4 of 9
Section Plans Verified Field Verified
# Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air Does Not
intakes and exhausts.
['Not Observable
ENot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) j
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 5 of 9
Section Plans Verified Field Verified
• # Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided. ❑Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel ❑ Steel [Not Observable
q
❑Not Applicable
303.2, Floor insulation installed per ElComplies
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
underside of the subfloor, or floor [Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least l of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
[IN3]1 exterior, the exterior insulation ❑ Mass III Mass ❑Not Observable
requirement applies (FR10). ❑ Steel El Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3)
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 6 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, Wood ❑ Wood ❑Does Not table for values.
402.2.2, Steel ❑ Steel [Not Observable
402.2.6
[Fill' ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]' Blown insulation marked every
300 ft'. ['Not Observable
ENot Applicable
402.2.3 Vented attics with air permeable ❑Complies
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ENot Observable
ENot Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F13]' insulation .?:R-value of the ❑Does Not
adjacent assembly.
['Not Observable
ENot Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[F117]' ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8.
ENot Observable
ENot Applicable
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 EComplies
[F127]' determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ['Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]' cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ENot Observable
tests, verification may need to ENot Applicable
occur during Framing Inspection.
403.3.2.1 Air handler leakage designated ❑Complies
[F124]' by manufacturer at <=2%of ❑Does Not
design air flow.
['Not Observable
ENot Applicable
403.1.1 Programmable thermostats ❑Complies
[F19]2 installed for control of primary ElDoes Not
heating and cooling systems and
initially set by manufacturer to ENot Observable
code specifications. ENot Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[F110J2 on heat pumps. ❑Does Not
ENot Observable
ENot Applicable
403.5.1 Circulating service hot water ❑Complies
[F111]2 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
ENot Applicable
Ill High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3)
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 7 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system EComplies
[FI25]2 fans not part of tested and listed EDoes Not
HVAC equipment meet efficacy
and air flow limits per Table ENot Observable
R403.6.1. ENot Applicable
403.2 Hot water boilers supplying heat ❑Complies
[FI26]2 through one-or two-pipe heating EDoes Not
systems have outdoor setback
control to lower boiler water ENot Observable
temperature based on outdoor ENot Applicable
temperature.
403.5.1.1 Heated water circulation systems EComplies
[F128]2 have a circulation pump.The EDoes Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe. Gravity and thermos- ENot Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies
[FI29]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the ENot Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Demand recirculation water EComplies
[FI30]2 systems have controls that EDoes Not
manage operation of the pump
and limit the temperature of the ENot Observable
water entering the cold water ENot Applicable
piping to <= 1049F.
403.5.4 Drain water heat recovery units EComplies
[F131]2 tested in accordance with CSA EDoes Not
B55.1. Potable water-side
pressure loss of drain water heat [Not Observable
recovery units < 3 psi for ENot Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 90% or more of permanent ❑Complies
[F16]1 fixtures have high efficacy lamps. EDoes Not
ENot Observable
ENot Applicable
404.1.1 Fuel gas lighting systems have EComplies
[F123]3 no continuous pilot light. EDoes Not
❑Not Observable
ENot Applicable
401.3 Compliance certificate posted. EComplies
[F17]2 EDoes Not
ENot Observable
ENot Applicable
1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) 1
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 8 of 9
Section Plans Verified Field Verified
• *# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
303.3 Manufacturer manuals for ❑Complies
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1
Project Title: Garage Remodel Report date: 06/18/20
Data filename: Page 9 of 9
2018 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 40.00
Below-Grade Wall 0.00
Floor 30.00
Ceiling / Roof 42.00
Ductwork (unconditioned spaces):
Glass& Door Rating U-Factor SHGC
Window 0.20
Door 0.10
Heating &Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments