inspection slips Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection re• -st ec; :•:
Queensbury Building&Code Enforcement Arrive: . p . Depart: O�;
742 Bay Road, Queensbury,NY 12804 Inspector's Initia.•
NAME: FERMI"• a /, 5- C/Lf •
LOCATION: DATE: S-11'W S
jCZ pl(t 9 COMMENTS:
// Y N NA
Chimney/"B"Vent/Direct Vent Location VQ/V
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent ^0
Interior/Exterior Guardrails 42 in. Platform/Decks ( \1\c t QC
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in. w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'V2 doors
> 10%> 1000 sq. ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20'wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc
Commercial Final Inspection Report
P P
Office No.: (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p `�gy�pp Depart:— ) am/pm /
742 Bay Road,Queensbury,NY 12804 Inspector's Initials: LJ
NAME: PERMIT#: —
LOCATION: DATE: 7_0
el a%Li- COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Ven ocation
Plumbing Vent Through Roof 6" Roof Complete
Exterior Finish Grade Complete 6"i ' quivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stoclroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors
> 10%> 1000 sq. ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond
Active Listening System and Signage Assembly Space
Final Electrical / t / -p eC GG .
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20' wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection req - t r-c •d:
Queensbury Building& Code Enforcement Arrive: a , pm D part: am/ m
742 Bay Road, Queensbury, NY 12804 Inspector's Initial / .-
NAME: PERMIT#: � ���
LOCATION: R-1( ZQi Q g e) INSPECT ON: VEIN,
TYPE OF STRUCTURE: ZOO Ore 9
_ Y N N/A
Framing / COMME " S
Jack Studs/Headers vv
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall ,
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003