inspection slips Commercial Final Inspection Report 9 ---/
Office No.: (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pn Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: �\//
NAME: Lcsx PERMIT#: _
LOCATION: DATE: T ii t
GI kks„ 3COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
t/ .
Exterior Finish Grade Complete 6" in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'V2 doors
> 10%> 1000 sq. ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required ,
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond
Active Listening Sys an i age ssebly Space
Final Electrical / ( t//
Site Plan/Variance equired
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20' wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 ARIL:\PamW\Building&Codes\Commercial Final Inspection Report.doc
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection req •st ec• • : _
Queensbury Building& Code Enforcement Arrive: a► p �.- •art: am/ 40,0.
742 Bay Road, Queensbury, NY 12804 Inspector's Initial••
NAME: ( �C. — PERMIT#: 5
LOCATION: t��� 0.��, �� INSPECT ON: �v — --�
TYPE OF STRUCT oQ . @�
N N/A
ming / COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall ,
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
cD—
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection.re. - ed:
Queensbury Building &Code Enforcement Arrive: a,, • Depart: 'it an
742 Bay Rd., Queensbury, NY 12804 Inspector's Initial.
NAME: RMIT#: 5-T t/S r.
LOCATION: Z X>%-e_ INSPECT ON: ) - D
TYPE OF STRUCTIf t: Sleoirk,t i n i t-
a 6364-3 Comments
Y N N/A
Footings
Piers
Monolithic Slab J
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Walipour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil .oly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003