inspection slips Commercial Final Inspection Report 1') V
Office No.: (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/$ Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials: `
NAME: PERMIT#: OS._ `7
LOCATION: 7104/yl.P (J DATE: •
\ w.7
(y 66. COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware, if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. _
Gas Valve Shut-off Exposed&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft.or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/2 doors
> 10%> 1000 sq. ft.
3/4 Hour Corridor Doors&Closers
Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft. Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in. Beyond
Active Listening System d j age Asse 1 Spce
Final Electrical C� / 5 0 5
Site Plan/Variance re fired
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20' wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\PamW\Building as Codes\Commercial Final Inspection Report.doc
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection req •st e • ed:
Queensbury Building& Code Enforcement Arrive: _a, pm iepart: a pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initia :
NAME: PERMIT#: _
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: (;,,-
Y N N/A COMMENTS
raming
Jack Studs/ Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspectio e. - ire eiv :
Queensbury Building &Code Enforcement Arrive: `�,6 • Depart: 2:tak;an1/pm
742 Bay Rd., Queensbury, NY 12804 Inspector's Initi:
AO m56, /
NAME: + ERMIT#: 0a5 �. /I
LOCATION: 4LSL
INSPECT ON: , AL5.
TYPE OF STRUCTURE:
Commen•.
Y 1 N N/A
ootings /
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
I.:\SueHemingway\Building.Codes.Inspcction.FURMSToundation Inspection Report.doc January 28,2003