ResCheck rGenerated by REScheck-Web Software
‘%4 Compliance Certificate
Project Entwistle - New Residence
Energy Code: 2018 IECC g C 0 3 ,2O 2l�
Location: Glens Falls, New York
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area: 1,625 ft2
Glazing Area 13%
Climate Zone: 6 (7635 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
1434 Bay Road Eli & Kristen Entwistle Ethan P. Hall
Queensbury, NY 12804 1434 Bay Road Rucinski Hall Architecture
Queensbury, NY 12804 134 Dix Ave
518-744-8977 Glens Falls, NY 12801
entwisee@hotmail ephall@nycap.rr.com
Compliance: Passes using UA trade-off
Compliance: 1.5%Better Than Code Maximum UA: 326 Your UA: 321
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling 1: Raised or Energy Truss 1,625 49.0 0.0 0.020 33
Wall 1: Wood Frame, 16" o.c. 1,973 21.0 3.6 0.046 77
Door 1: Solid 28 0.300 8
Door 5: Solid 18 0.300 5
Door 4: Solid 18 0.300 5
Door 2: Glass 40 0.320 13
Door 3: Glass 36 0.320 12
Window 1: Wood Frame:Double Pane with Low-E 153 0.290 44
Wall 2: Wood Frame, 16" o.c. 448 21.0 3.6 0.046 16
Door 6: Glass 40 0.320 13
Window 2: Wood Frame:Double Pane with Low-E 52 0.290 15
Floor 2: All-Wood Joist/Truss:Over Outside Air 72 30.0 0.0 0.033 2
Floor 1: Slab-On-Grade:Unheated 22 14.0 0.730 16
Insulation depth: 4.0'
Basement Wall 1: Solid Concrete or Masonry 1,186 19.0 0.0 0.052 62
Wall height: 8.9'
Depth below grade: 6.0'
Insulation depth: 8.5'
Project Title: Entwistle - New Residence Report date: 07/20/20
Data filename: Page 1 of10
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory r ireme li t t REScheck Inspection Checklist.
fl.tpa 1? ON-— 42.6 1 44- Zo Jut 2ozo
Name-Title Signat e Date
Project Title: Entwistle- New Residence Report date: 07/20/20
Data filename: Page 2 of10
• REScheck Software VersionChecklist: REScheck-Web
Energy Code: 2018 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review I Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and 1icomplies
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and Complies
103.2, documentation demonstrate f, ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ONot Observable
Systems serving multiple DNot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: Eeomplies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable
Manual J or other methods Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Entwistle- New Residence Report date: 07/20/20
Data filename: Page 3 of10
Section Plans Verified Field Verified
# Foundation Inspection Value I Value Complies? Comments/Assumptions
di Req.ID
111 l
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values.
V ❑ Heated ❑ Heated ❑Not Observable
❑Not Applicable
402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies
[F03]1 depth/length. ❑Does Not table for values.
v. ['Not Observable
❑Not Applicable
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[F04]1 insulation R-value. Where interior R- R- ❑Does Not table for values.
b insulation is used, verification
may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[F05]1 insulation installed per ❑Does Not
4. manufacturer's instructions.
❑Not Observable
ElNot Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[F06I1 insulation depth of burial or ❑Does Not table for values.
distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[FO11]2 to protect exposed exterior ❑Does Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[F012]2 controls installed. ❑Does Not
V ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 1 3 1Low Impact(Tier 3)
Project Title: Entwistle - New Residence Report date: 07/20/20
Data filename: Page 4 of10
Section Plans Verified Field Verified
# Framing/ Rough-In Inspections Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- EComplies See the Envelope Assemblies
402.3.1, average). EDoes Not table for values.
402.3.3,
402.5 ENot Observable
[FR2]1 ❑Not Applicable
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
ENot Observable
taken from the default table.
ENot Applicable
402.4.1.1 Air barrier and thermal barrier EComplies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
ENot Observable
ENot Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440 ENot Observable
or has infiltration rates per NFRC
400 that do not exceed code ENot Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures EComplies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ENot Observable
ENot Applicable
403.3.1 Supply and return ducts in attics EComplies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >_
R-6 where < 3 inches. Supply and ENot Observable
return ducts in other portions of ENot Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.2 Ducts, air handlers and filter EComplies
[FR13]1 boxes are sealed with ❑Does Not
joints/seams compliant with
International Mechanical Code or ❑Not Observable
International Residential Code, as ❑Not Applicable
applicable.
403.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
b ['Not Observable
❑Not Applicable
1 'High Impact(Tier 1) 12 !Medium Impact(Tier 2) 13 I Low Impact(Tier 3)
Project Title: Entwistle - New Residence Report date: 07/20/20
Data filename: Page 5 of10
9 P
Section Plans Verified Field Verified
# Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions
& Rect.ID 403.3.7 Ducts declared to be within the ❑Complies
[FR2813 conditioned space are either 1) ❑Does Not
completely within the continuous
air barrier and within the building [Not Observable
thermal envelope, 2) buried ❑Not Applicable
within ceiling insulation in
accordance with Section
R403.3.6 and the air handler is
located completely within the
continuous air barrier and within
the building thermal envelope
and the duct leakage is <= 1.5
cfm/ 100 square feet of
conditioned floor area served by
the duct system, or 3)the ceiling
insulation R-value installed
against and above the insulated
duct >= to the proposed ceiling
insulation R-value, less the R-
value of the insulation on the
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]z above 105 4F or chilled fluids ❑Does Not
below 55 4F are insulated to >_R-
3 ENot Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 zR-3. ElDoes Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19)2 installed on all outdoor air ❑Does Not
intakes and exhausts.
['Not Observable
ENot Applicable
Additional Comments/Assumptions:
i1JHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1Low Impact (Tier 3)
Project Title: Entwistle - New Residence Report date: 07/20/20
Data filename: Page 6 of10
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
d provided.
ONot Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 0 Steel ❑ Steel :Not Observable
V, ❑Not Applicable
303.2, Floor insulation installed per DComplies
402.2.7 manufacturer's instructions and ODoes Not
[IN2]1 in substantial contact with the
d underside of the subfloor,or floor ❑Not Observable
framing cavity insulation is in DNot Applicable
contact with the top side of
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the ❑ Wood 0 Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass 0 Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
d requirement applies(FR10). ❑ Steel 0 Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 j High Impact(Tier 1) 2 Medium Impact(Tier 2) j 3 [Low Impact(Tier 3) I
Project Title: Entwistle- New Residence Report date: 07/20/20
Data filename: Page 7 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel :Not Observable
402.2.6
[FI1]' ONot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[FI2]' Blown insulation marked every
300 ft2. ['Not Observable
ONot Applicable
402.2.3 Vented attics with air permeable OComplies
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ONot Observable
ONot Applicable
402.2.4 Attic access hatch and door , R- R- ❑Complies
[FI3]' insulation zR-value of the ❑Does Not
adjacent assembly.
['Not Observable
ONot Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies
[F1171' ach in Climate Zones 1-2,and ❑Does Not
<=3 ach in Climate Zones 3-8. DNot Observable
ONot Applicable
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[FI27]' determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ONot Observable
pressure differential of 0.1 inch ONot Applicable
w.g,across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[FI4]' cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ONot Observable
tests,verification may need to ONot Applicable
occur during Framing Inspection.
403.3.2.1 Air handler leakage designated ❑Complies
[FI24]' by manufacturer at<=2%of ❑Does Not
design air flow.
:Not Observable
ONot Applicable
403.1.1 Programmable thermostats ❑Complies
[FI912 installed for control of primary ODoes Not
heating and cooling systems and
initially set by manufacturer to ONot Observable
code specifications. ONot Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. ❑Does Not
❑Not Observable
ONot Applicable
403.5.1 Circulating service hot water ❑Complies
[FI1112 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
ONot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Entwistle- New Residence Report date: 07/20/20
Data filename: Page 8 of10
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system EComplies
[FI25]2 fans not part of tested and listed EDoes Not
HVAC equipment meet efficacy
and air flow limits per Table ['Not Observable
R403.6.1. ❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[FI26)2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
--
403.5.1.1 Heated water circulation systems ❑Complies
[FI28)2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply [Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ElComplies
[F129]2 comply with IEEE 515.1 or UL ❑Does Not
515. Controls automatically
adjust the energy input to the ['Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Demand recirculation water ❑Complies
[FI30]2 systems have controls that ❑Does Not
manage operation of the pump
and limit the temperature of the [Not Observable
water entering the cold water ❑Not Applicable
piping to <= 1044F.
403.5.4 Drain water heat recovery units ❑Complies
[F131]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ['Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 90%or more of permanent ❑Complies
[F16]' fixtures have high efficacy lamps. ❑Does Not
❑Not Observable
❑Not Applicable
.404.1.1 Fuel gas lighting systems have Complies
[FI23]3 no continuous pilot light. ❑Does Not
ENot Observable
❑Not Applicable
401.3 Compliance certificate posted. ❑Complies
[F17]2 ❑Does Not
❑Not Observable
❑Not Applicable
[1 High Impact(Tier 1) [ijMedium Impact(Tier 2) 3 (Low Impact(Tier 3)
Project Title: Entwistle - New Residence Report date: 07/20/20
Data filename: Page 9 of10
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID1
303.3 Manufacturer manuals for ❑Complies
[FI18)3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) J
Project Title: Entwistle - New Residence Report date: 07/20/20
Data filename: Page 10 of10
r2018 IECC Energy
‘%6 Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 24.60
Below-Grade Wall 19.00
Floor 30.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass & Door Rating U-Factor SHGC
Window 0.29
Door 0.32
Heating & Cooling Equipment Efficiency
Heating System: _
Cooling System:
Water Heater:
Name: Date:
Comments