Loading...
2005-120 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20050120 Date Issued: Thursday, August 18, 2005 This is to certify that work requested to be done as shown by Permit Number P20050120 has been completed. Tax Map Number: 523400-296-019-0001-019-000-0000 Location: 78 GLENWOOD Ave Owner: KENNETH HEIN Applicant: ALLSTATE INSURANCE CO. This structure may be occupied as a: Commercial Alteration By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enfo emen Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050120 Application Number: A20050120 Tax Map No: 523400-296-019-0001-019-000-0000 Permission is hereby granted to: AT,T,STATF,TNSI JRANC F, CO For property located at: 78 GLENWOOD Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOSEPH&RICHARD CANTZ CAROLYN ACCARDI Comtnercial Alteration $95,000.00 Total Value $95,000.00 9 HOYT Ave GLENS FALLS, NY 12801 Contractor or Builders Name /Address Electrical Inspection Agency Plans&Specifications 2005-120 ALLSTATE INSURANCE CO. 1145 SQ FT COMMERCIAL INTERIOR ALTERATION AND 672 SQ FT ALTERATION TO GARAGE FOR STORAGE $227.64 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, April 12, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the of Que sb ; r y, April 12, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement WINDOW SCHEDULE Job Site/Address: -7ff Date: P-,/30 a r Owner: Application No. Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening Glass/Vis Egress/Cle Opening Opening or Instructions Letter on Name Ndirawljie Numbe g Height able Vent ar Width In Height Plan Cali Width Light Opening Inches In Inches Size tJLL 36%6 3< 2Vrq<q 5f q1 02et, rz__ Example Entry A Andersen Narroline 3062 3' 2 6'5 '/2 15.30 8.36 6.01 34 2416/3611 Tempered Double 1/3" 11/16 Glazing Hun C:\Documents and Settings\Sue\Local Settings\Temp\Window Schedule.doc let �� Job Site Address: Date:.. .3 �� a Owner: Application No. File No. Building Permit — Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req.Light Actual Req.Vent Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Rodin Vent Opening for in Area Square Area Square Egress Square Footage Footage Feet 1. ,E .� lqq 35 L:\.SueHemingway\Building.Permit.FORMS\NatLight Ventil.Calculation.Sheet.doc r. DRAFT COPY (3121/03) CHECKLIST NYS BUILDING'CODE(BC) Building: �p�! �.!/�`> .:�!►.S NYS FIRE CODE(FC) NYS PLUMBING CODE (PC) Location: Cr NYS MECHANICAL CODE (MC) NYS FUEL GAS CODE (FGC) Date: ,31b1S NYS ENERGY CODE (ECC) Reviewer. Publication Date: May 2002 COMMERCIAL & MULTIPLE DWELLING OCCUPANCIES No. Topic Code Page Required Actual Section No. or Allowed 1 Jurisdiction BC-101.2 1 2 Flood Plain BC-1603.1.E 285 3 Separated or Non-Separated BC-302.3 18 Occupancies* 4 Occupancy BC-302 17 f� 5 Type of Construction BC-Table 601 81 58 6 No. of Sleeping Units/Level BC-202 14& No. of Units—Total 31 No. of Occupants BC-Table 1003.2.2.2 201 7 Covered Malts BC-402 33 Hi-Rise (75'Rule) BC-403 36 Atriums BC-404 37 8 Basement Definition BC-502.1 71 (See page 8 of this check list) Legend: NR= Not Required NS= Not Shown NA= Not Applicable Note: *Non-separated occupancies.impose the most restrictive requirements JAM Page 'I of 10 No. Topic Code rN . or Allowed Required Actual 9. Heights& Building Areas Section o Maximum Tabular Area BC-Table 503 72 Maximum Tabular Height BC-Table 503 72 Maximum Stories BC-Table 503 72 Mezzanines BC-505 73 10. Sprinkler System (water) BC-903 168 Basement Sprinkler BC-903.2.10.1 170 Water Source Sprinkler BC-903.3.5 172 Water Source Site FC-508.1 31 11. Frontage&Sprinkler Credits Area Modifications (calc.) BC-506 74 Height Modifications BC-504 73 12. Height&Area Summary: Ht/Area Ht/Area Tabular Area BC-Table 503 72 Frontage Credit BC-506 74 Sprinkler Credit BC-506.3 75 Total Allowable Area Max Aggregate Area BC-503.3 73 (Allowable Area/Fir. x No. of Stories up to 3 maximum) 13. Fire Apparatus Road FC-503.1 29 (150'rule) � � rQ Fe S ,S� 3 I 14. Exterior Walls Distance Separation* BC-Table 602 82 Exterior Wall Openings BC-Table 704.8 87 Parapets BC-704.11 88 Exterior Wall Coverings' BC-Table 1405.2 257 Exterior Wall Finishes BC-Table 1406.2 261 Combustible * Distance separations are doubled if fire fighting water is not available (FC-508.1.3). NOTES; JAM Page 2 of 10 No. Topic Code Page Required Actual Section No. or Allowed 15. Fire Rated Construction (� Incidegtal Use Areas BC-Table 302.1.1 17 dam' F Accessory Occupancy BC-302.2 18 Mixed Occupancy BC-Table 302.3.3 19 Control Areas BC-414.2 52 Fire Walls BC-705 89 Fire Barrier BC-706 91 Shaft Enclosure BC-707 92 Fire Partition (Tenant Sep.) BC-708 95 Smoke Barriers BC-709 96 Opening Protectives BC Table 714.2 101 Fire Blocking BC-716 107 Draft Stopping BC-716.3 108 space 4#jL Aces31-C&wI tC- tzoe 2.5A Min. Rm. Dimensions 'rrv- BC-1207.1 251 Min. Ceiling Height BC-1207.2 251 ---�' 17. Ventilation (Nat. or Mech.) BC-1202.1 249 18. Light(Nat. or Mech.) BC-1204.1 250 19. Exits rdeM01t.A,60 e1c /00,�L z'! al'a Occupancy Load BC Table 1003.2.2.2 201 One Exit Permitted BC Table1005.2.2 224 Stair Enclosure BC-1005.3.2 224 Emergency Egress BC-1009.1 235 Distance of Travel BC-Table 1-004.2.4 220 Aisle Width BC-1004.3.1.1 221 Corridor Width BC-1004.3.2.2 221 �� ' 1 Capacity of Exits (talc.), BC-Table 1003.2.3 202 Corridor Wall Fire Rating BC-Table1004.3.2.1 222 Corridor Dead End BC-1004.3.2.3 222 Door Width BC-1003.3.1.1 208 Door Swing BC-1003.3.1.2 208 Panic Hardware BC-1003.3.1.9 213 20. Stairs Riser BC-1003.3.3.3 213 -- Tread BC-1003.3.3.3 213 Width BC-1003.3.3.1 213 Headroom BC-1003.3.3.2 213 Vertical Rise BC-1003.3.3.E 215 Handrails BC-1003.3.3.11 215 6uelIs b C /6a3 s 3,2.lZ- vs, Mav OCi5a /2-1 "fk 3 A c 1003.:3,3(0 JAM Page 3 of 10 No Topic Code Page Required Actual Section No. or Allowed 21. Structural Snow* oading—Ground BC Fig 1608.2 296 Snow Loading—Roof(calc.) ASCE 7-98 Drifting Snow BC-1608.7 295 Ponding BC-1608.3.5 295 Floor Loading BC Table 1607.1 291 Balcony Loading BC-Table 1607.1 291 Wind Loading (calc.) BC-1609 297 Roof Walls Windows Seismic Loading (calc.) BC-1614 315 Foundation Depth BC-1805.2 398 -� 22. Interior Finishes BC-Table 803.4 161 23. Swimming Pools BC-3109 629 24. Sun Rooms BC Appendix 1 693 25. Electrical Exit Lights or Signs BC-1003.2.10 203 Emergency Lights BC-1003.2.11.2 204 Emergency Power BC-2702 611 General Lighting-Exits-Stairs BC-1003.2.41 204 26. HC ACCESS Exempt Buildings BC-1104.4 238 Parking BC-Table 1106.1 239 Route BC-1104.1 238 Entrance BC-1105.1 239 #of Sleeping Rooms BC-Table-1107.6.1.1 241 #of Dwelling Units BC-1107.6.2 241 Toilet Facilities BC-1109.2 244 Service Counters BC-1109.12.3 246 Areas of Refuge BC-1003.2.13.5 207 Signage Supplemental HC Req'mts Appendix E 681 27. SPECIAL INSPECTIONS BC-1704 379 Notes: JAM Page 4 of 10 No. Topic Code Page Required Actual Section No. or Allowed 28. Fire Protection Equipment Central Station Monitoring FC-901.9 52 AIK Sprinkler Systems FC-903 55 Other Extingushing Syst. FC-904 59 Kitchen Hood Extinguisher FC-609.8 41 Standpipe Systems FC-905 62 Fire Extingushers FC-906 64 Fire Alarm Systems &SD FC-907.2 66 Fire Alarm Boxes+Zav$f FC-907.4.1 90' -9 72;73 Smoke Detection FC-907.2.10 68 Hi-Rise Fire Safety FC-907.2.12 69 Visible Alarms FC-Table 907.10.1.2 73 Smoke Control FC-909 75 Smoke Vents FC-910 82 Fire Pumps FC-913 85 il-Y.--SP- e ,V FC-9D3.2,10. ) 5(a 29. Plumbing Code Fixture Count PC-Table 403.1 21 �k�n Ly1. •s2/wct Sil k Water SSupoly Service Pipe Size PC-603 33 Fixture Pipe Size PC-603.1 - 33 Pipe Material PC-Table 605.4 36 Labor Law Art. 10-A UFPBC-904.6 12,340 • Pipe Insulation See Energy Code Backflow Prevention PC-Table 608.1 41 Sprinkler System PC-608.16.4 44 Lawn Irrigation PC-608.16.5 44 Pipe Freezing PC-305.6 14 Sanitary Drainage Drain Pipe Size PC-Table 709.1 54 Drain Pipe Material PC-702 47 Labor Law Art 10-A UFPBC-904.6 12,340 Vent Size PC-Table 910.4 63 Pipe Hangers PC-Table 308.5 - 17 Air Admittance Valves PC-917 67 Notes: JAM Page 5 of 10 No. Topic Code Page Required Actual Section No. or Allowed 30. Mechanical Code Ventilation Rates MC-Table 403.3 24 Propane Below Grade MC-502.8.10.1 31 Dryer Exhaust MC-504 33 Kitchen Exhaust MC-506 34 Kitchen Hoods MG-507 37 Kitchen Make-Up Air MC-508 39 Chimney Termination MC-Table 511.2 41 Air Plenums MC-602 47 Fire& Smoke Dampers MC-607.5.1 52 Combustion Air MC-701 55 Confined Spaces—Def. MC-202 5 31. Fuel Gas Code Appliance Location FGC-303 18 Combustion Air FGC-304 19 Clearance to Combust. FGC-Table 308.2 25 Pipe Material FGC-403 46 Shut Off Valves FGC-409 53 Chimney Termination FGC-Fig. 503.5.4 63 Gas Vent Termination FGC-Fig. 503.6.6 65 Exit Terminal Location FGC-503.8 - 68 Clothes Dryer Exhaust FGC-613 96 Unvented Room Heaters FGC-620 99 32. Energy Code Prescriptive Method ECCC-Table 602.1(1) 50 High Truss Credit ECCC-602.1.2 51 Pipe Insulation—Heating ECCC-Table 503.3.3.1 44 Duct Insulation—Heating ECCC-Table 503.3.3.3 45 Pipe Insulation—Hot Water ECCC-Table 504.2 47- HWH Heat Trap ECCC-504.7 47 COMcheck Computer Software Compliance Report Required Notes. / �.^�, : ,` � l !_'rl`C/'1`- �«7 c'/ u�l� ;� . ' /Or./J G.,a,✓�Tf-. % Srr'dn;il JAM D 1 tJFtiR � zJ6 titJ 'F oc5v%v,)6-�2 Page 6 of 10 i LIST OF CALCULATIONS THAT MAY BE REQUIRED FOR A COMPLETE CODE REVIEW. 1. Area Increase Based Upon Frontage And Sprinkler Increase. Frontage'Increase: If= 100(F/P-0.25)W = Answer in % 30 Note: If= 75%when 4 sides accessible&water available Allowable Area: Aa=Awj,+ (A..x If) + (Ah, x I.)=Answer in Square Feet (BC-Pg. 74) 100 100 2. Exit Capacity Calculations (Table 1003.2.3)(BC-Pg. 202) (Occupancy Load for Exit)x(Egress Width per Occupant)_ (Required Width) 3. Snow Loading Calculations. (ASCE 7-98)(Eq. 7-1)(pg-69)& (Eq. 7-2)(pg-70) (ASCE =American Society of Civil Engineers) Pf=0.7CeC=IP9= Flat Roof Snow Load Where: Pf= Flat Roof Snow Load (Calculated Above,Answer in#per SF) Ce= Exposure Factor (BC-Table 1608.3.1)(Pg. 297) C,= Thermal Factor (BC Table 1608.3.2)(Pg.297) 1 = Importance Factor (BC-Table 1604.5)(Pg. 287) P9= Ground Snow Load (BC Fig. 1608.2)(Pg. 296) P$= CSPf=Sloped-Roof Snow Load Where: Pg= Sloped-Roof Snow Load Cs= Roof Slope Factor (ASCE 7-98)(Pg. 70) 4. Wind loading calculations. (Refer to Chapter 6 of ASCE 7-98) 5. Seismic Calculations. (See page 10 of this list) 6. COMCheck calculations (For verification of compliance with the Energy Code) JAM Page 7 of 10 r 8. GRADE PLANE: A reference plane representing the average of finished ground level adjoining the building at exterior walls.Where the finished ground level slopes away from the exterior walls, the reference plane shall be established by the lowest points within the area between the building and the lot line or,where the lot line is more than 6 feet from the building, between the building and a point 6 feet from the building. 9. MEZZANINE: An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than 1/3rd of the area of the room or space in which the level or levels are located. (Mezzanine area does not contribute to the building area or the height in stories but does contribute to the fire area, aggregate area).. 10. SMOKE BARRIER: A continuous membrane, either vertical or horizontal, such as a wall, floor, or ceiling assembly,that is designed and constructed to restrict the movement of smoke. (Required to have a 9 hr. fire rating). 11. STORY ABOVE GRADE PLANE: Any story having its finished floor surface entirely above grade plane, except that a basement shall be considered as a story above grade plane where the finished surface of the floor above the basement is: 1. More than 6 feet above grade plane or 2. More than 6 feet above the finished ground level for more than 50% of the total building perimeter or 3. More than 12 feet above the finished ground level at any point. JAM Page 9 of 10 TOWN OF Q UEENSB URY 742 Bay Road, Queensbury, NY. 12804-5902 March 16, 2005 Bob Feeney 123 Northwest Road Queensbury, NY 12804 Dear Bob: The following items need to be addressed on the plans for the All State Insurance building before issuance of a permit can be granted. 1. The second floor storage room must be rated and details must be shown on the plans as to how a one hour rating will be achieved in this room. 2. There is no attic access shown in the ceiling of the second floor nor the attic of the detached garage, if it is to be sheet rocked. 3. We need to assure that the building is provided with a four percent ventilation through the windows for each room or that fresh air will be introduced in to the building at a rate of 20 cubic feet per person installed with the HVAC system. 4. The door going on to the existing porch that is to be relocated must be a Low Threshold 36 inch door and be ramped to the porch. 5. It is not clear as to what stairs will be existing and what stairs will. be new. Any new stairs are required to have a seven inch rise and eleven inch tread, with handrails and guards per Code Section 1003.3.3.11 and 1003.3.3.2.12. 6. We need to know the types of interior finishes that will be provided throughout the building. 7. There is no detail on the handicap ramp or the front entry porch as far as size dimensions and details on railings required by the Code. A detail plan needs to be shown for this ramp and entry area. 8. There are no details on the handicap bathroom fixtures. We need elevations showing location of handrails, height of the handicap sink and fixtures associated with the bathroom. 9. All new doors must be 36 inch with lever handles. 10.A drinking fountain or water cooler needs to be provided in the space. 11.We need a garage foundation layout. Also, elevations for the garage. On the cross section ice and snow shield must be shown two feet inside the exterior walls. 12.We need all structural loads regarding wind, snow, and seismic pertaining to the garage with engineer stamp on those calculations as well as the drawings for the garage. 13.Emergency lights need to be shown throughout the building to light up the path to the exit door within the building. Please add emergency lights as needed. Also, the garage will need to be provided with an exit light emergency light combination unit. 14.Is there to be a fire alarm system installed within this building or not? 15.Fan shutdown is requested on the furnace, HVAC System if it is over 2000 CFM with a monitoring system. Once the above items have been addressed satisfactorily, a building permit will be issued. The above information as based on the plans currently submitted to this Office. "Home of Natural Beauty ... A Good Place to Live " Permit No. Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid 01 r)---1V] .Co q 742 Bay Road,Queensbury,NY 12804 Recreation Fee Dave Hatin,Director codes@aueensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder Owner: ' Address: Address: 2. v Home Phone: 14Home Phone: S Email Address: Email Address: Cell Phone: 7 l 72�/ Cell Phone: FAX Phone: FAX Phone: , ! — 1 F Person responsible for supervision of work with respect to building and codes compliance: Name: e Address: Phone Location of proposed construction: Lot No. Legal Address: Tax Map Number: 9(0 j Subdivision Name: Estimated Cost of Construction: Proposed construction is for: _Residential Use C �nercial Use Name of Business: f If proposed construction is an addition, what will use of new addition be? New Addition Alteration Proposed Construction 1d Floor 2^d floor Other Total Proposed structure (Occupancy Type) S sq.ff. Sq. Ft. Square feet Height Ft.S.ln. Sin le-famil Dwellin cf� Two-Family Dwelling Townhouse C Multifamily Dwelling J Number of Units: Office ',rt,e.0 rc ercantlle Manufacturin Other `? ached GaT020,47213 Z_ Type of Heating System: Electri , Oil, Gas, Wood, Forced Hot Air, Baseboard, Other: Is a fireplace and/or woodstove being installed, please refer to a separate application. _Yes No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Co an As-Built Survey by a licensed surveyor drawn to scale, showing actual location of all n onstru o Date: (9 Applicant/Builder Signature: dated The application of is hereby approved and permission granted for the cons,truction, reconstruction or alteration of building/and or accessory structure as set forth above. _ Date: lLItaAuthorized Signature: _ L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04 Application for Permit=Septic Disposal SysteM Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: ............................................ ..,............................................. 'Office Use Location of installation: File Permit No. Tax Map No. i '• Fee Paid Owner's Name: ................:......................................_..... ...: :T Address: (/ 2. INSTALLER'S NAME 7r PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) i Year of House: No of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980—1991 x 130 gal/bdrm = 1991 —present x 110 gal/bdrm = i Garbage Grinder Installed yes / no Spa or Hot Tub Installed yes, / no 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Swnply Flat sand at what depth at what depth municipal Rolling loam feet feet well Steep slope clay ` if well;water supply �%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the!size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: gallon(min. size 1,000gal) Tile Field: each trench ft. Total System Length: ft. Seepage Pit(s): number of size of each: ft. by ft. Size of Stone to be used: # / depth or thickness feed, Bed System Size: x i i Alternative System: length and/or size --- 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL C2ppacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. i I Signature of responsible person bate i • . � '►1♦p�Vll UT t�llt;('11;41)lit'a+ ' i J Sr�Vcr:c and Di pos:LI (:1111j)irr i Appetuli x (• r Al1.80R)"•1'I(2N I"II+j1.►I.) 'SI'PARA'I♦ION IIaPA2L3MEhIVNIIA I . 1 •01 - /T POND Wit 1buaE : I 4 IAA r��" 11%�usa: (�, ►. ..01..••• 1 ...1 .'' sc t•t tc. " '� FA ot l�y�tJR1►rlOt f i*r0.L�► j wr— ttUhO . I i 7, SICN A►TURE &Fr of WAMOI I For, i 1 I I ' I � I I � i' 1 j' t 1 �T l`n S � f n 3 } 1 x i s; � i t {.-._�. kleKv 1 er iv 16e,- t i roc tVitli �•�g ,, I, 6 e-p dial se, 4A 'r-r ate" o<<, hooe r"p p w 4VA r 77 soil 3��n�r Q�pF U S I ONg1 F 6ff MSS %ONTGp2� t 40, t Y 0 At, f y�FTHE ST P���� 3 ---------- AC4 L low C9 ' .UAAG Figure 28 Page 1 of 1 36 rnin via is 36 min 'fib min 975 18 +64 405 1$ main 42 min i s Ltd d.1 rCii JLiL i t t Inv:: 1 1 J 7- fi II lam, SD dur Wrer i clear floor t floor 4 t floor $put opwo YY sp"t .....ZI—,.,.. ...48 nun..,. n 48 min wpm 15STB T J� Figure 28 Clear Floor Space at Water Close For a front transfer to the water closet, the minimum clear floor space at the water closet is a minimum 48 inches (1220 mm) in width by a minimum of 66 inches (1675 mm) in length. For a diagonal transfer to the water closet, the minimum clear floor space is a minimum of 48 inches (1220 mm) in width by a minimum of 56 inches (1420 mm) in length. For a side transfer to the water closet, the minimum clear floor space is a minimum of 60 inches (1525 mm) in width by a minimum of 56 inches (1420 mm) in length. (4.16.2, A4.22.3) Back_toADAAG List of Fi urea =r http://www.access-board.gov/adaag/htmi/figures/fig28.html 1/10/05 t A3DAAG Figure A6 Page 1 of 2 } 1S• _S i j 1 S t f 7 1 9 7 t S "Cake.Umdw pw%on,rMngs liemrawes ermneaC lnnnfasa. !M&M whesMch*out d OW PoAmn an to t"Isms iS]ot"out of* way,seta way,dunpaa poOm(some balm bmlm& MieIola d%wor Plod a 9C atla;ntletk. tefuf Jlppnarlaln S r .4 \ 3 3 Takes unOw po"m earnmes Transhm Po"rw on Collet, WMMk eerx brekm (b) 8ida AppnercA Figure A6 Wheelchair Transfers Fig. A6(a) Diagonal Approach (to the toilet fixture). A diagonal transfer is illustrated as follows. Diagram 1: wheelchair user takes a transfer position diagonal to the toilet fixture, swings footrest out of the way, sets brakes. Diagram 2: removes armrest, transfers. Diagram 3: moves wheelchair out of the way, changes position (some people fold chair or pivot it 90 degrees to the toilet). Diagram 4: positions on toilet, releases brake. Fig. A6(b) Side Approach (to the toilet fixture). A side transfer is illustrated as follows. Diagram 1: wheelchair user takes transfer position parallel to the side of the toilet fixture, removes armrest, sets brakes. Diagram 2: transfers. Diagram 3: positions on toilet. (A4.16.4, A4.22.3) http://www.access-board.gov/adaag/html/figures/figa6.httnl 1/10/05 .• ADAAG Figure 29 Pagel of 1 36 min 916 54 min 6 min 1370 12 min 12 min 12 42 min 3os 3" MIS lees toilet {Diaper LVi? u, C* Back Wall Swe Wall Figure 28 Grab Bars at Water Closets Fig. 29(a) Back Wall. A 36 inch (915 mm) minimum length grab bar is required behind the water closet mounted at a height between 33 and 36 inches (840-915 mm). The grab bar must extend a minimum of 12 inches (305) beyond the center of the water closet toward the side wall and a minimum of 24 inches (610 mm) toward the open side for either a left or right side approach. hack toA-DAAG. List o..f_Figure.s http://www.access-board.gov/adaa.g/html/figures/fig29.html 1/10/05 ..ADAAG Figure 32 Page 1 of 1 17mi 430 YY#+Y#M YYYIIYY# i#Y.#MY c lea r + f toot Y # # rYY#.�Y YM rY eY sa YY�F= " max 405 ir In Figure 32 Clear Floor Space at Lavatories The minimum depth of the lavatory is 17 inches (430 mm). (4.19.3, 4.24.5) Sack t®_ADAAG List of # http://www.access-board.gov/adaag/html/figures/fig32.html 1/10/05 ADAAG Figure 31 Page 1 of 1 x7 E t" 'o t% f'tl � ��//�[��yypp� !oE - C4tri7iraCtr 6f anCR m� Atrplh Figure 31 Lavatory Clearances In addition to clearances discussed in the text, the following knee clearance is required underneath the lavatory: 27 inches (685 mm) minimum from the floor to the underside of the lavatory which extends 8 inches (205 mm) minimum measured from the front edge underneath the lavatory back towards the wall; if a minimum 9 inches (230 mm) of toe clearance is provided, a maximum of 6 inches (150 mm) of the 48 inches (1220 mm) of clear floor space required at the fixture may extend into the toe space. (4.19.2, 4.19.6) Back to_ADAA-Q List-,of Figures • • http://www.access-board.gov/adaag/html/figures/fig3l.html 1/10/05 ` Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: IL qn�/pm Dep rt: am/pm 742 Bay Road, Queens ury,NY 12804 Inspector's Initials: NAME: S PERMIT#: � ' LOCATION: wvocL DATE: U COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6" in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36(w)x 44" 1)/Cano or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 'h doors >10%> 1000 s . ft. 3/<Hour Corridor Doors&Closers Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers 1 Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ram /Handrails Continuous/12 in.Be and Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides ' /Driv a Surface 20' wide Oka To Issue Temp. or ermanent CKY Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC� Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL —T,J Permit No........................................Cert. N 2 89585 Cut-in Card No......................../.:'T�1 Owner............ i........ ..:.. :.. ............. ........................................................ ........... ....... ............................... Location..................... L-V.I.rV .. ..... t.................................Lf7rw,(S ., ......... Installation Consisting of.. I. f..,� �„ ...............„�............... �fI2�GE .................................................................................................................................................................................. ................................ ............................................................................................................. InstalledBy.....1.1...r....AF&?M .._.......................................Lic.No.................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued i, ,ancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the ntroduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege o making ' pe ions at any time, and if its ules are violated,the Company shall have the right t rev this c ificate. Date....��..c..7'0. ........ INSPECTOR... ...................... P. f� Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: I,am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: \�NAME: _ PERMIT#: ✓ LOCATION: —� DATE. COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete. Exterior Finish Grade Complete 6"in 10' or Equivalent. Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks _ [/ Stair Handrail 34 in.-38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. ��/,-j ��. C-V�t e All Doors 36 in,w/Lever Handles/Panic Hardware, if re uired Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %2 doors > 10%> 1000 s . ft. C � / ` 3,��,�r 3/4 Hour Corridor Doors&Closers /)G telh`f 0- I`ry�Q- Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" �n s✓ Si Handicapped Ram /Handrails Continuous/12 in.Beyond Active Listening System and Signa e Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File / Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides b 20' /D ' le Surface 20'wide Oka To Issue Tem . or Perman C/ Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc �s Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 Fire Marshal's inspection Report Request SCHEDULES— Received: Permit# ' tNSPECTION ON: Name: �;(,.� 5��— LAMPM ANYTIME Location: liv / IJu=E� '�> APPROVED N/A YES NO COMMENTS EXIT ACCESS EXIT ENCLOSURE EXIT DISCHARGE MAIN AISLE WIDTH -' SECONDARY AISLE WIDTH T g�,-fi� EXIT SIGN-NORMAL ^t C Y� 5 C, EXIT SIGN-BATTERY EMERGENCY LIGHTING _ FIRE EXTINGUISHER HUNG FIRE EXTINGUISHER INSPECTION FIRE EXTINGUISHER HYDRO WCy /vY-- FIRE ALARM SYSTEM fl FIRE ALARM -FAN SHUTDOWN FIRE SPRINKLER SYSTEM C(>-Y\ FIRE SUPPRESSION-KITCHEN FIRE SUPPRESSION-GAS ISLAND HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO ELECTRICAL ELECTRIC WIRING ENCLOSED COMBUSTIBLE WASTE VEHICLE IMPACT PROTECTION FIRE LANE F.D.SIGNAGE-UTILITY ROOMS NO SMOKING SIGNS MAXIMUM OCCUPANCY SIGN EMERGENCY EVAC PLAN OK THIS DATE FOR O NOT OK INSP BY COMDEII/CHRISJIWORDILETTERS200ilF IREMARSHAUNSPECTIONREPORT11022001 WHITE—BUILDING DEPARTMENT COPY YELLOW—OCCUPANT COPY Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518):745-4]437Fire Marshal's Inspection Report Request SCHEDULE Received: Permit#=— f-'� INSPECTION ON: C-An L�� A Name: - AM PM YTIME Location: / APPROVED N/A Y S NO COMMENTS EXIT ACCESS EXIT ENCLOSURE EXIT DISCHARGE �� N MAIN AISLE WIDTH SECONDARY AISLE WIDTH X t4 G L' ri 4 c9 +✓ EXIT SIGN-NORMAL EXIT SIGN-BATTERY EMERGENCY LIGHTING _ G �C,� FIRE EXTINGUISHER HUNG FIRE EXTINGUISHER INSPECTION FIRE EXTINGUISHER HYDRO FIRE ALARM SYSTEM FIRE ALARM -FAN SHUTDOWN FIRE SPRINKLER SYSTEM FIRE SUPPRESSION-KITCHEN FIRE SUPPRESSION-GAS ISLAND x HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO ELECTRICAL ELECTRIC WIRING ENCLOSED COMBUSTIBLE WASTE VEHICLE IMPACT PROTECTION FIRE LANE X— F.D.SIGNAGE-UTILITY ROOMS NO SMOKING SIGNS �N MAXIMUM OCCUPANCY SIGN _ EMERGENCY EVAC PLAN OK THIS DATE O R CO r, NOT OK INSPEC ED BY COMDEVIC HRISJ/WORDILETTERS20011FIREMARS HALINSPECTIONRE PORT 11022001 WHITE-BUILDING DEPARTMENT COPY ` YELLOW-OCCUPANT COPY Commercial Final Inspection Report � 1 Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: --21 in—am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: Affi— NAME: PERMIT#:_ LOCATION: = DATE: COMMENTS: Y N NA Chimne /"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks 1 V Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" rrJ Vestibules For Exit doors>3000 s . ft. C4,- All Doors 36 in.w/Lever Handles/Panic Hardware, if required / Exits At Grade Or Platform 36(w)x 44" 1)/Canopy or Equiv. l Gas Valve Shut-off Exposed&Regulator 18" Above Grade 4 / Floor Bathroom Watertight/Other Floors Oka rlw, Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System , Fresh Air Supply for Occupancy/Ventilation Combustion a1r xt Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area L ,,�j Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors ✓ j/ >10%> 1000 s . ft. '7 &n 3/a Hour Corridor Doors&Closers , Firewalls/Fire Separation, 2 Hour, 3 Hour Complete/Fire p Dampers/Fire Doors , Q„ Sr�Ce Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed �� Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na a Public Toilet Room Handicapped Accessible r i � jV� .✓ Handicapped Service Counters, 34 in., Checkout 3611 s / / !✓ 4 Handicapped Ram /Handrails Continuous/12 in.Beyond ` Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,-if req. As-built Septic System Layout Required or On File � - Building Number or Tenant Address on Building or Driveway4 r ~ Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide � Oka To Issue Temp. or Permanent C/O /ti r�( J,/Z- J S r`` Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\Building&Codes\Commercial Final Inspection Report.doc Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection rer- NAME: Queensbury Building & Code Enforcement Arrive: part: �� ao� 742 Bay Road, Queensbury, NY 12804 Inspector's Init PERLOCATION: INSO TYPE OF STRUCTURE: lY N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Header` 5 .S.I for 15 minutes sulation Residential Check/ Commercial Check Proper Vent Attic Vent g' Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Formsaough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.(,),., Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL ?ermit No........................................Cert. N 0 90103 Cut-in Card No.................... Jwner........... . ... ."S?.....�.................................................................................................�......... ................................ ..7.................... nstallation Consisting of.Z 3 1 M-'o" � a G-,re-5 ................................. ...................................!;;r................ ........................................................................ nstalledBy........?.( L.. ..............................................Lic.No.................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued is ;ancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the ntroduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin inspections at any time, and if its ules are violated,the Company shall have the right t r ke thi ce ificate. )ate.... ... .. :. .......... INSPECTOR.......................................... Framing / Firestopping Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: �`3-' am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: f NAME: iflL� h� PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUC Y N /A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers �� E E' `��� ��' NR P Bracing/Bridging Joist hangers C64 huh, cc d l C r Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/s w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilin wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reques c v d: Queensbury Building & Code Enforcement Arrive: a /p art: Ta742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: PERM T #:LOCATION: ( - Qmt,�xc-� INSPECT ON: TYPE OF STRUCTURE: Rough PlumbingY N N/A Nail Plates 1 Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washinq Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air /,Head 5 .S.1 for 15 minutes sulation Residential Check/ Commercial Check Proper Vent Attic Vent _ Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodeAnspection Fonns\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Repo Office No. (518) 761-8256 Date InIrev d: Queensbury Building& Code Enforcement Arrivepert: u a m 742 Bay Road, Queensbury, NY 12804 InspectNAME: IT#: (QS — LOCATION: INSPECT ON: —2—(-'7 TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers ✓� Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. 1�� LcD Stairwells 36 in. or more Headroom 6 ft. 8 in. -� Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side � 1�-��i— �-�-� Draft stopping 1,000 sq. ft. floor trusses Ge ��`� Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Repoit.doc January 28,2003 Foundation Inspection Report Office No. (51 8) 761-8256 Date Inspection re uest c ive _ Queensbury Building &Code Enforcement Arrive: a in Depart: Z anm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: 1 IT#: LOCATION: p SPECT ON: _ — TYPE OF STRUCTURE: Comments Y N N/A � otings Piers17-11 Monolithic Slab Reinforcement in Place �E 1`'l , The contractor is responsible for Cw E providing protection from freezing 1. for 48 hours following the placement t�\ of the concrete. CO v 1 Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re est ive . Queensbury Building&Code Enforcement Arrive: pm -pDepart: m 742 Bay Rd.,Queensbury, NY 12804 Inspector's Init' Is: NAME: IT#: LOCATION: _' `t (-� emn� 1 INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A otings ' Piers Monolithic Slab Reinforcement in Place The contractor is responsible for t providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place T \CA �-- L.� Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 �( O Foundation Inspection Report Office No. (518)761-8256 Date Inspection re es ce i ed: Queensbury Building&Code Enforcement Arrive: p Depart: a 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia s: NAME: `���;� IT#: LOCATION: PECT ON: TYPE OF STRUCT E: Comments Y N N/A otings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing T Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:tSueHemingway\Building.C'odes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: .J6_am/pm Depart:-am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: 1 'T1CQ PERMIT#: r �o LOCATION: INSPECT ON: -- TYPE OF STRUCTU /i Y N N/A 1 raming COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams �( 'ek c�c��,r Exterior sheeting nailed properly 12"O.C. C A, S���Q� Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade I_:\Sue Hemingway\BuiIding.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Seismic Design Evaluation for r the,State Farm Insurance Office 78 Glenwood Avenue Avenue, Queensbury, New York This office area is identified by the U>S> Department of Agriculture Soil Survey of Warren County, New York by Map #36. The soil in this area is of the Oakville Series which is relatively flat and very sandy. Bedrock (limestone) is usually over 5ft. below grade and the frost action is low. The office to be reconstructed is located in Seismic Use Group I (very limited public liability), Section 1616.2.1. Its site class is A, Section 1615.1.1. The Importance Factor for this property shall be Ic = 1.00, Table 1604.5. The Seismic Design Category, Sds = <.167g, Table 1616.8.1. The Seismic Design Category Sd1= <.067g, Table 1616.3.2. The construction of the office section will not increase or decrease any element of the existing adjoining structure by more than 5%. The basic seismic-force-resisting system is that of a conventional bearing wall system and a moment- resisting frame system for support of vertical and lateral forces. Design requirements for Seismic Design Category A are as follows: a. Minimum Lateral Force (Section 1616.4.1) Fx= .01 Wx(x=one of each story) W=live load(0. story)=70,000 lbs. live load (2°d. story) =52,000 lbs. dead load(total) = 15000 lbs. permanent equipment(total) =500 lbs. 20%of 60 PSF (ground snow load of 70 PSF) = 12,000 lbs. Fx= .O1 x 149.500 lbs. = 1495 lbs. b. Connections(Section 1616.4.2) All connections between the existing structure and the new office shall be capable of transmitting the seismic force, Fp. C. Anchorage (Section 1616.4.3) Concrete and masonry walls shall be anchored to floors, roofs and other structural elements that provide lateral support for the walls. Such anchorage shall provide a positive direct connection capable of resisting the horizontal forces specified in Chapter 16 but not less than a minimum of 200 lbs. per linear foot of wall. Walls shall be designed to resist bending between anchors, which are spaced no further apart than 41 All required anchors in masonry walls shall be embedded in a reinforced grouted structural element of the wall. Wind and earthquake design requirements shall comply with Chapter 16. d. Conventional Light Frame Construction(Section 1616.4.4) This construction is not a Light Frame Construction Design as shown in Section 2308 and does not affect this construction conforming to Section 1616.4. All design and construction of this office complies with all requirements of Section 1616.4 Roof Load(Snow or live) M W F R S Building is enclosed Exposure Factor=Ce= !.2 Thermal Factor= Ct= 1.0 Importance Factor= Is= 1.1 Sloped Roof is 6"in 12" Snow load per sq.ft. = 70 PSF ground snow load area= 32,000 lbs. live and dead loads. The trusses must be certified to support this load. Wind Load Simplified proceedure used---Section 1609.6.1 of New York State Building Code. NOTE: This garage not used for public access. Wind speed=90 MPH Minimum load per sq.ft. = 10 PSF Exposure Category=B Importance Factor=Lw= W Transverse load= 8,4121bs. Longitudinal load= 11,01Olbs. Overturning Force= 5,280lbs.from West or East The newly constructed garage must resist overturning and wind forces protected by near-by structures. The snow load in the 70 PSF area will more than take care of the overturning and the wind loads. The trusses should be certified to carry the snow load. Q�pFESS(ONq�F c�S�oQ�%ONTOQ���c�F 3 � i s�lr '03 41'� OFTHE$IN � a� �_.. . %. ajwll r-ivaivanon for the State Farm Insurance Office 78 Glenwood Avenue Avenue, Queensbury, New York This office area is identified by the U>S>Department of Agriculture Soil Survey of Warren County, New York by Ma #36. The soil in this area is of the Oakville Series which is relatively flat and very sandy. Bedrock (limestone) is usuall over 5ft. below grade and the frost action is low. The office to be reconstructed is located in Seismic Use Group I (ver limited public liability), Section 1616.2.1. Its site class is A, Section 1615.1.1. The Importance Factor for this propert; shall be Ic = 1.00, Table 1604.5. The Seismic Design Category, Sds = <.167g, Table 1616.8.1. The Seismic Desigi Category Shc=<.067g, Table 1616.3.2. The construction of the office section will not increase or decrease any element of the existing adjoining structure b3 more than 5%. The basic seismic-force-resisting system is that of a conventional bearing wall system and a moment- resisting frame system for support of vertical and lateral forces. Design requirements for Seismic Design Category A are as follows: a. Minimum Lateral Force (Section 1616.4.1) Fx= .01 Wx(x=one of each story) W=live load(1". story)= 70,000 lbs. live load(2°d. story)=52,000 lbs. dead load(total) = 15000 lbs. permanent equipment (total) = 5001bs. 20%of 60 PSF (ground snow load of 70 PSF) = 12,000 lbs. Fx= .01 x 149.500 lbs. = 1495 lbs. b. Connections(Section 1616.4.2) All connections between the existing structure and the new office shall be capable of transmitting the seismic force, Fp. C. Anchorage(Section 1616.4.3) Concrete and masonry walls shall be anchored to floors, roofs and other structural elements that provide lateral support for the walls. Such anchorage shall provide a positive direct connection capable of resisting the horizontal forces specified in Chapter 16 but not less than a minimum of 200 lbs. per linear foot of wall. Walls shall be designed to resist bending between anchors, which are spaced no further apart than 4ft. All required anchors in masonry walls shall be embedded in a reinforced grouted structural element of the wall. Wind and earthquake design requirements shall comply with Chapter 16. 1. Conventional Light Frame Construction(Section 1616.4.4) This construction is not a Light Frame Construction Design as shown in Section 2308 and does not affect this construction conforming to Section 1616.4. All design and construction of this office complies with all requirements of Section 1616.4 Roof Load(Snow or live) M W F R S Building is enclosed Exposure Factor=Ce= !.2 Thermal Factor=Ct= 1.0 Importance Factor= Is= 1.1 Sloped Roof is 6"in 12" Snow load per sq.ft. = 70 PSF ground snow load area= 32,000 lbs. live and dead loads. The trusses must be certified to support this load. Wind Load Simplified proceedure used---Section 1609.6.1 of New York State Building Code. NOTE: This garage not used for public access. Wind speed=90 MPH Minimum load per sq.ft. = 10 PSF Exposure Category=B Importance Factor=Lw= W Transverse load= 8,412lbs. Longitudinal load= 11,01Olbs. Overturning Force= 5,2801bs.from West or East The newly constructed garage must resist overturning and wind forces protected by near-by structures. The snow load in the 70 PSF area will more than take care of the overturning and the wind loads. The trusses should be certified to carry the snow load, �DQRpMS104,,41F� 2 0 4 y iT 0370 y�FTHE S10-%