BINS-002408-2019 05032019INSPECTION WORKSHEET (BINS-002408-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0023-2019 Case Module:Permit
Inspection Date:Fri May 3, 2019 Inspection Status:Failed
Inspector:John O'Brien Inspection Type:Building Framing
Job Address:Parcel Number:63 QUAKER RD
Queensbury, NY 12804
296.18-1-5
Contact Type Company Name Name
Granted Permission 63 Quaker, LLC
Applicant 63 Quaker, LLC
Primary Owner Fiacco, Michael
Contractor J & P Builders
Architect KPB Architecture
Checklist Item Passed Comments
Building Inspector Notes NO 5/2/19 Framing Not Approved
- Remove carriage bolts from post to beam connections and
install hex head bolts.
- Install Truss Bracing as per Truss Bracing Sheets.
- Remove all screws from truss hanger toe nail locations and
install specified hanger nails or screws.
- Verify all Existing and new trusses are anchored to the
beam.
- Submit 3rd party engineer's structural inspection of all
canopy framing.
CALL FOR RECHECK WHEN READY FOR INSPECTION!
May 03, 2019 Page (1)
INSPECTION WORKSHEET (BINS-002408-2019)
Checklist Item Passed Comments
Framing NO 5/2/19 Framing Not Approved
- Remove carriage bolts from post to beam connections and
install hex head bolts.
- Install Truss Bracing as per Truss Bracing Sheets.
- Remove all screws from truss hanger toe nail locations and
install specified hanger nails or screws.
- Verify all Existing and new trusses are anchored to the
beam.
- Submit 3rd party engineer's structural inspection of all
canopy framing.
CALL FOR RECHECK WHEN READY FOR INSPECTION!
Jack Studs Headers NO
Continuous Header for Garage Doors with
Straping
NO
Truss Specification Provided NO
Bracing Bridging NO
Hurricane Clips/Uplift Screws/Nail Holes Filled NO
Air Seal all Plates and Sills NO
Air Seal All Registers at Floor NO
Air Sealing all Joints Before Insulation NO
Joist hangers NO
Jack Posts Main Beams NO
Exterior sheeting nailed properly NO
May 03, 2019 Page (2)
INSPECTION WORKSHEET (BINS-002408-2019)
Checklist Item Passed Comments
12 O.C.NO
Headroom 6 ft. 8 in.NO
Notches Holes Bearing Walls NO
Metal Strapping for Notches Top Plate NO
Anchor Bolts 6 ft. or less on center NO
Ice and water shield 24 inches from wall NO
Soffits-Insulation Baffel NO
Windows Habitable Space Bedrooms NO
24 in. (H)NO
20 in. (W)NO
5.7 sf above below grade NO
5.0 sf grade NO
Design Professional Sign-off, if required NO
May 03, 2019 Page (3)
O'Brien, John (Inspector)