BINS-002885-2019 05212019INSPECTION WORKSHEET (BINS-002885-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0023-2019 Case Module:Permit
Inspection Date:Tue May 21, 2019 Inspection Status:Passed
Inspector:John O'Brien Inspection Type:Building Framing
Job Address:Parcel Number:63 QUAKER RD
Queensbury, NY 12804
296.18-1-5
Contact Type Company Name Name
Architect KPB Architecture
Applicant 63 Quaker, LLC
Granted Permission 63 Quaker, LLC
Contractor J & P Builders
Primary Owner Fiacco, Michael
Checklist Item Passed Comments
Building Inspector Notes YES 5/2/19 Framing Not Approved
- Remove carriage bolts from post to beam connections and
install hex head bolts.
- Install Truss Bracing as per Truss Bracing Sheets.
- Remove all screws from truss hanger toe nail locations and
install specified hanger nails or screws.
- Verify all Existing and new trusses are anchored to the
beam.
- Submit 3rd party engineer's structural inspection of all
canopy framing.
CALL FOR RECHECK WHEN READY FOR INSPECTION!
5/21/19 Framing Approved
May 21, 2019 Page (1)
INSPECTION WORKSHEET (BINS-002885-2019)
Checklist Item Passed Comments
Framing YES 5/2/19 Framing Not Approved
- Remove carriage bolts from post to beam connections and
install hex head bolts.
- Install Truss Bracing as per Truss Bracing Sheets.
- Remove all screws from truss hanger toe nail locations and
install specified hanger nails or screws.
- Verify all Existing and new trusses are anchored to the
beam.
- Submit 3rd party engineer's structural inspection of all
canopy framing.
CALL FOR RECHECK WHEN READY FOR INSPECTION!
5/21/19 Framing Approved
May 21, 2019 Page (2)
O'Brien, John (Inspector)