Loading...
ResCheck . Generated by REScheck-Web Software Compliance Certificate Project Foothills Builders c2C - On() " 202o Energy Code: 2018 IECC Location: Glens Falls, New York n,� _._tF ' Construction Type: Single-family 14 1 -U p`er Y Project Type: New Construction Conditioned Floor Area: 1,352 ft2 Glazing Area 11% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 75 Round Pond Rd Daniel W. Ryan P.E. Queensbury, NY 12804 P.O. Box 596 Glens Falls, NY 12801 dryan@dwrpe.com Compliance:.Passes using.UA trade-off' Compliance: 0.0%Better Than Code Maximum UA: 195 Your UA: 195 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies • - Gross Area 'Cavity - Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling: Raised or Energy Truss 728 38.0 0.0 0.025 18 Wall 1: Wood Frame, 16" o.c. 810 21.0 0.0 0.057 39 Door 1:Solid Door(under 50%glazing) 18 0.140 3 Door 2: Solid Door(under 50%glazing) 20 0.240 5 Door 3: Glass Door(over 50%glazing) 40 0.290 12 Window:Vinyl Frame 52 0.290 15 Wall 2:Wood Frame, 16" o.c. 875 21.0 0.0 0.057 45 Window:Vinyl Frame 78 0.290 23 Floor:All-Wood Joist/Truss 104 38.0 0.0 0.026 3 Basement:Solid Concrete or Masonry - 780 0.0 22.0 0.034 26 Wall height: 7.8' Depth below grade: 7.0' Insulation depth: 7.8' Window:Vinyl Frame 3 0.400 1 Window 1:Vinyl Frame 16 0.290 5 Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory r ents 'st in the REScheck Inspection Checklist. Daniel W. Ryan P.E. 1 /P ,--- 6/10/20 Name-Title Signature Date ENGINEERSSTAMP: / ris: y O �_, . 1 ,.' 1 f jl 61()FESS1e .' Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 2 of10 0 REScheck Software VersionChecklist: REScheck-Web Inspect Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified . Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, 'Construction drawings and =,DComplies 103.2 !documentation demonstrate • {❑Does Not [PR1]1 {energy code compliance for the ` _! {building envelope.Thermal ;❑Not Observable {envelope represented on ❑Not Applicable !construction documents. ►103.1, Construction drawings and -,❑Complies 103.2, {documentation demonstrate ❑Does Not { 403.7 !energy code compliance for [PR3]1 {lighting and mechanical systems. ❑Not Observable {Systems serving multiple j❑Not Applicable {dwelling units must demonstrate ;{ !compliance with the IECC {Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not (PR2]2 {on loads calculated per ACCA , Cooling: Cooling: EJ ;Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 3 of10 Section . Plans Verified Field Verified #. Foundation Inspection Complies? Comments/Assumptions & Req:ID Value Value 402.1.1 . ;Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R_ R- ODoes Not table for values. 0,1 {insulation is used,verification ❑Not Observable !may need to occur during Insulation Inspection. Not ❑Not Applicable ;required in warm-humid locations 'in Climate Zone 3. 303.2 'Conditioned basement wall ❑Complies [F05]1 'insulation installed per 'i❑Does Not manufacturer's instructions. -;❑Not Observable I ;❑Not Applicable 402.2.9 tConditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 {insulation depth of burial or - ODoes Not table for.values. 'distance from top of wall. ❑Not Observable ► ❑Not Applicable 303.2.1 A protective covering is installed �❑Complies [F011]2 to protect exposed exterior ❑Does Not 4?) insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 ;Snow-and ice-melting system ;❑Complies [F012]2 controls installed. ODoes Not J ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 4 of10 Section Plans Verified field Verified Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, 'Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 [ ODoes Not table for values. [FR1]1 DNot Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, ;average). DDoes Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 I ❑Not Applicable 303.1.3 l U-factors of fenestration products ❑Complies [FR4]1 fare determined in accordance ' ;❑Does Not !with the NFRC test procedure or , ;taken from the default table. [Not Observable [ Observable,,_, Applicable 402.4.1.1 1Air barrier and thermal barrier ❑Complies [FR23]1 ;installed per manufacturer's • j❑Does Not .0; l instructions. + -' Not Observable 1 ,.;;❑Not Applicable 402.4.3 ;Fenestration that is not site built ❑Complies [FR2O]1 1 is listed and labeled as meeting ❑Does Not IAAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable !or has infiltration rates per NFRC ' {❑Not Ap plicable that do not exceed code !limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 ',sealed at housing/interior finish ❑Does Not 'and labeled to indicate 52.0 cfm Not Observable ;leakage at 75 Pa. ❑Not Applicable 403.3.1 Supply and return ducts in attics _ !❑Complies [FR12]1 !insulated >= R-8 where duct is ❑Does Not �;; 1,>= 3 inches in diameter and >= 1R-6 where <3 inches.Supply and DNot Observable [return ducts in other portions of ,DNot Applicable !the building insulated >= R-6 for !diameter>=3 inches and R-4.2 /for<3 inches in diameter. 403.3.2 (Ducts,air handlers and filter ❑Complies [FR13]1 !boxes are sealed with ❑Does Not ;joints/seams compliant with ;!International Mechanical Code or ONot Observable !International Residential Code,as ❑Not Applicable !applicable. 403.3.5 {Building cavities are not used as , ,'f❑Complies [FR15]3 ;ducts or plenums. = '• ❑Does Not 4 1 . :;'❑Not Observable , ,❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 5 of10 Section Plans Verified Field Verified Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID Value Value 403.3.7 ;Ducts declared to be within the Complies [FR28]3 'conditioned space are either 1) >❑❑Does Not !completely within the continuous ; } 'air barrier and within the building ❑Not Observable ;thermal envelope,2) buried •❑Not Applicable :within ceiling insulation in accordance with Section R403.3.6 and the air handler is ' located completely within the 1continuous air barrier and within !the building thermal envelope ;,: ;and the duct leakage is <= 1.5 icfm/100 square feet of ;conditioned floor area served by :the duct system,or 3)the ceiling + insulation R-value installed !against and above the insulated ;duct>=to the proposed ceiling • ;insulation R-value,less the R- ;value of the insulation on the • 4034 ;HVAC piping conveying fluids R- R- DComplies [FR1712 !above 105 °F or chilled fluids ❑Does Not !below 55°F are insulated to 3 :Not Observable ❑Not Applicable 403.4.1 ;Protection of insulation on HVAC ❑Complies [FR2411 ;piping. ❑Does Not ❑Not Observable } Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 ❑Does Not [Not Observable ONot Applicable 403.6 :Automatic or gravity dampers are 1LiComplies [FR19]2 ;installed on all outdoor air • ❑Does Not !intakes and exhausts. .- ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 6 of10 Section' Plans Verified Field Verified $# Insulation'Inspection Complies? Comments/Assumptions Req.ID Value Value: 303:1 ;All installed insulation is labeled OComplies [IN13]2 :or the installed R-values " ❑Does Not provided. ❑Not Observable ,ONot Applicable 402.1.1, !Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood i 0 Wood ODoes Not table for values. [IN1]1 0 Steel ❑ Steel 4;, [Not Observable DNot Applicable 303.2, I Floor insulation installed per _ ❑Complies 402.2.7 :manufacturer's instructions and 3❑Does Not [IN2]1 lin substantial contact with the ❑Not Observable ;underside of the subfloor, or floor , ;framing cavity insulation is in ON Applicable ;contact with the top side of ;sheathing,or continuous I insulation is installed on the ;underside of floor framing and ', , !extends from the bottom to the I top of all perimeter floor framing '". I members. 402.1.1, !Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, ;mass wall with at least 1/2 of the 0 Wood ❑ Wood ❑Does Not table for values. 402.2.6 Iwall insulation on the wall {IN3]1 ;exterior,the exterior insulation ❑ Mass ❑ Mass :Not Observable y, !requirement applies(FR10). 0 Steel 0 Steel ❑Not Applicable i 1 303.2 'Wall insulation is installed per :❑Complies [IN4]1 !manufacturer's instructions. Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 7 of10 1 Section. Plans Verified Field Verified •. Final'Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID . 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, 0Wood 0 Wood ODoes Not table for values. 402.2.2, Steel 0 Steel 402.2.E ❑Not Observable [FI1]1 ONot Applicable 303.1.1.1,!Ceiling insulation installed per 'OComplies 303.2 manufacturer's instructions. [FI2]1 Blown insulation marked every �': ODoes Not 1300 ft2. 'ONot Observable I : ❑Not Applicable 402.2.3 :Vented attics with air permeable ,DComplies (FI22]z insulation include baffle adjacent ' :DDoes Not to soffit and eave vents that Not Observable ;extends over insulation. '❑ ONot Applicable 402.2.4 'Attic access hatch and door R- R- DComplies [FI3]1 1 insulation R-value of the ElDoes Not !adjacent assembly. ONot Observable I ONot Applicable 402.4.1.2 'Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = DComplies [F117]1 lach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. :Not Observable I ONot Applicable 403.3.3 {Ducts are pressure tested to cfm/100 cfm/100 DComplies [FI27]1 !determine air leakage with ft2 ft2 ODoes Not !either: Rough-in test:Total !leakage measured with a ['Not Observable !pressure differential of 0.1 inch ONot Applicable lw.g.across the system including !the manufacturer's air handler !enclosure if installed at time of !test. Postconstruction test:Total !leakage measured with a !pressure differential of 0.1 inch ! .g.across the entire system iwncluding the manufacturer's air handler enclosure. 403.3.4 !Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 Icfm/100 ft2 across the system or ft2 ft2 ODoes Not I<=3 cfm/100 ft2 without air !handler @ 25 Pa. For rough-in [Not Observable !tests,verification may need to ONot Applicable {occur during Framing Inspection. 403.3.2.1 {Air handler leakage designated ,,DComplies [F124]1 I by manufacturer at<=2%of ODoes Not `design air flow. ❑Not Observable I . DNot Applicable 403.1.1 ;Programmable thermostats '''DComplies [F19]z I installed for control of primary ODoes Not :heating and cooling systems and initially set by manufacturer to ONot Observable code specifications. ;ONot Applicable 403.1.2 i Heat pump thermostat installed ' ,'DComplies [FI10]2 on heat pumps. ' ❑Does Not DNot Observable ❑Not Applicable 403.5.1 :Circulating service hot water :';❑Complies [F111]2 . :systems have automatic or ,;'.:i❑Does Not accessible manual controls. `''❑Not Observable _'❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 8 of10 Section Plans.Verified Field Verified Final Inspection.Provisions Complies? Comments/Assumptions & R'eq.ID Value Value 403.6.1 All mechanical ventilation system, ❑Complies [F12512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy 'ONot Observable ;and air flow limits per Table R403.6.1. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 ;through one-or two-pipe heating -N ‘ ❑Does Not ;systems have outdoor setback !control to lower boiler water ❑Not Observable ;temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 ;Heated water circulation systems ,DComplies [FI28]2 have a circulation pump.The ❑Does Not !system return pipe is a dedicated ; ;return pipe or a cold water supply; DNot Observable pipe.Gravity and thermos ❑Not Applicable syphon circulation systems are ;not present..Controls for circulating hot water system 'pumps start the pump with signal, ;for hot water demand within the ; • . ;occupancy.Controls . ,automatically turn off the pump f" when water is in circulation loop is at set-point temperature and , no demand for hot water exists. 403.5.1.2 ;Electric heat trace systems '❑Complies [FI2912 ;comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically '❑Not Observable !adjust the energy input to the 'heat tracing to maintain the :`❑Not Applicable desired water temperature in the • piping. • 403.5.2 Demand recirculation water ❑Complies [F130]2 :systems have controls that ❑Does Not 'manage operation of the pump ❑Not Observable and limit the temperature of the water entering.the cold water -❑Not Applicable ;piping to<=.1049-F. , 403.5.4 Drain water heat recovery units ;❑Complies [FI31]2 'tested in accordance with CSA ;❑Does Not `B55.1. Potable water-side :Not Observable ;pressure loss of drain water heat ❑Not Ap plicable recovery units< 3 psi for ;individual units connected to one ;or two showers. Potable water • - side pressure loss of drain water ;heat recovery units< 2 psi for ;individual units connected to ;three or more showers. or more of lies [FI6]1 `90%u es have high efficacytlamps ❑Do spNot ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have ;❑Complies [FI23]3 no continuous pilot light. `❑Does Not ` ;;DNot Observable ❑Not Applicable 401.3 Compliance certificate posted. ' ❑Complies (F17]2 ❑Does Not ❑Not Observable DNot Applicable 1 High Impact(Tier 1) '.2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 9 of10 Section Plans Verified Field Verified Complies? Comments/Assumptions ` Final Inspection Provisions 'Value Value p & Req:ID 303.3 ;Manufacturer manuals for ;❑Complies [FI18]3 (mechanical and water heating :❑Does Not ;systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Report date: 06/10/20 Data filename: Page 10 of10 r 2` 1 07 ''tt r FCC ,. �, *, r e r q \ Cli Insulation Rating _ R-Value ' Above-Grade Wall 21.00 Below-Grade Wall 22.00 Floor 38.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor; SHGC Window 0.29 Door 0.29 Heating&.Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: P Name: Date: Comments