BINS-000417-2019 01172019
INSPECTION WORKSHEET (BINS-000417-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
RC-0480-2018Permit
Case Number:Case Module:
Thu Jan 17, 2019Partial Pass
Inspection Date:Inspection Status:
John O'BrienBuilding Foundation
Inspector:Inspection Type:
11 Beacon Hollow DR297.13-1-39
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
Granted Permission HAYES CONSTRUCTION GROUP,
LLC
Applicant HAYES CONSTRUCTION GROUP,
LLC
Primary Owner HAYES CONSTRUCTION GROUP,
LLC
EngineerRucinski-Hall Architecture
Contractor HAYES CONSTRUCTION GROUP,
LLC
Checklist ItemPassedComments
Building Inspector NotesNO1/17/19 Dampproofing Approved
FootingsYESWith 2 rows # 4 continuous wet sticking verticals every 40"
o/c 1/4/19
1/7/19 interior footing with two #5 rebar
PiersNO
Monolithic SlabNO
Reinforcement in PlaceNO
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (BINS-000417-2019)
Checklist ItemPassedComments
Foundation / WallpourYES1/7/19 rear frost wall with one #5horizontal rebar
1/14/19 foundation walls with 2 rows # 4 continuous
Reinforcement in PlaceNO
Foundation DampproofingYES1/17/19 Dampproofing Approved
Footing Drain Daylight or SumpNO
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalNO
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabNO
O'Brien, John (Inspector)
Jan 17, 2019Page (2)