I 308.12-1-10 SEP-0502-2020
Alcuri, Peter
22 West Dr
Residential Septic Alteration
CENT R P OJ Cr
SERVICES
`.ER IC +S' T A
73 Sheridan Street, Glens Falls,NY 12801
Phone-518-796-2515
August 20, 2020
Project#316
George Drellos
Sanitary Sewer Service
Queensbury,NY 12804
Re: Proposed Replacement Septic
22 West Drive Queensbury, NY
Dear George:
At your request, we have reviewed your proposed replacement septic system design of the
existing 2-bedroom house at 22 West Drive in Queensbury. As per our conversation the
residence has an existing failed septic system.
We have reviewed the proposed replacement septic system design and we agree that a standard
absorption bed is acceptable. Based upon a design flow rate of 220 GPD and a percolation rate of
1 to 5 minutes, you will need a minimum of 245 sf of absorption area. We recommend using 20
ft wide by 25 ft long absorption bed with 4 — 20 ft long laterals. The absorption system can be
constructed with a new 1,000-gallon septic tank, new distribution box, and 4-inch diameter
perforated pipe and stone.
Please feel free to contact me at 796-2515 if you have any questions and that you for your
assistance with this request.
Sincerely,
Thomas R. Center Jr, P.E.
/I : !q7