August 20, 2020
Project#317
Fred Smith
Smiths Excavating
Queensbury,NY 12804
Re: Proposed Replacement Septic
64 Rhode Island Avenue Queensbury, NY
Dear George:
At your request, we have reviewed your proposed replacement septic system design of the
existing 4-bedroom house at 64 Rhode Island Avenue in Queensbury. As per our conversation
the residence has an existing failed septic system.
We have reviewed the proposed replacement septic system design and we agree that a standard
absorption bed is acceptable. Based upon a design flow rate of 440 GPD and a percolation rate of
1 to 5 minutes,you will need a minimum of 489 sf of absorption area. We recommend using 20
ft wide by 35 ft long absorption bed with 4 — 30 ft long laterals. The absorption system can be
constructed with a new 1,250-gallon septic tank, new distribution box, and 4-inch diameter
perforated pipe and stone.
Please feel free to contact me at 796-2515 if you have any questions and that you for your
assistance with this request.
Sincerely,
Thomas R. Center Jr,P.E.
AUG 25 2020
TOWN OF QUEENSBURY