Loading...
RC-0255-2020 • PRINCIPLE STRUCTURE Office Use Only PERMIT APPLICATION Permit#: '62_55 Town of Queensbury Permit Fee:$ 1 ' 2-* 0 742 Bay Road,Queensbury, NY 12804 *Rec. Fee:$ ki-Pt-- P: 518-761-8256 www.queensburynet Invoice#: • Project Location: !Z t`/i}cc 1 t L s.6ic9a-1 Tax Map #: ZO, .!/-/-/7 Subdivision Name: TOWN BD.RESOLUTION 86-2013:$850 recreation fee for new dwelling units: single family, duplexes/two-family, multiple family, apartments,condominiums, townhouses,and/or manufactured &modular homes,but not mobile homes. This is in addition to the permit fee(s). CONTACT INFORMATION: • Applicant: Name(s): Atikr-I i ti & .4- c) Mailing Address, C/S/Z: t paQ,K I ?c, &— Cell Phone: (S1 e ) - -7 t Z Land Line: ( ) Email: /4-OAr-t E e_c 1 • Primary Owner(s): DECEIIVEri Name(s): 6 .t4-SvL _ 1�1 Mailing Address, C/S/Z: 11111 I`tna (. „�,� i'] Cell Phone: ( 20a Land Line: Email: TOWN OF A i_ -I NO&CODES ❑ Check if all work will be performed by homeowner only • Contractor(s): Workers' Comp documentation must be submitted with this application Contractor Name(s): lZvsEwc�v� �•,,c��,�� ��� C Contractor Trade: G-E refit! f-C•4 r- A- Mailing Address, C/S/Z: 7'(?vY , H,5 i, -a4-est9 ( b 4,47744".-/ Cell Phone: (SI `cam ) ' VL Land Line: ( ) Email: M. _r . wM **List all additional contractors on the back of this form • Architect(s)/Engineer(s): Business Name: l r/.i-t_ l (/ ) P' _ C. -• Contact Name(s): k4- 7 L' ►.c DEte,e) Mailing Address, C/S/Z: Rv. ,v 7 L/ ,4 qs,s ct , h y zU S� Cell Phone: 151E ) Land Line: ( ) Email: k774-Z DcLdc>. QGrr g L.e01- 7 Contact Person for Building & Code Compliance:_ Cell Phone: (t r53, ) 3cD/-'11? S Land Line: ( ) Email:_ ,4p4-.,4,r}.sAr_.e crew 4EE ivc -4 SScefe-r-ES •C�l�-t Principle Structure Packet Revised February 2019 PRdJECT INFORMATION: TYPE: _Commercial Residential WORK CLASS: ingle-Family _Two-Family _Multi-Family(#of units ) _Townhouse _Business Office _Retail _Hotel/Motel Industrial/Warehouse _Garage(#ofcars ) _Other(describe ) STRUCTURE SQUARECz FOOTAGE: GARAGE SQUARE FOOTAGE: 1sT floor: 8 OS 1sT floor: 2"d floor: 2nd floor: 3rd floor: Totals a feet: Basement(habitable space): Q Total square feet: Z l•sE ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $_ /.5',c,c->c) 2. Proposed use of the building: ICA-ger /,6 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat: Gas Oil •ropane Solar Other: (Fireplaces need a separate I = . mg Appliances&Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES 6-ICD Explain: 6. Are there any easements on the property?6D NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? q L-W- b. Is this a corner lot? YES O c. Will the grade be changed as a resu of the construction? G N• d. What is the water source? PU PRIVATE e. Is the parcel on SEWER or a IVATE SEPTIC sy m? Principle Structure Packet Revised February 2019 c DECLARATION: I. !acknowledge that no construction shall commence priorto issuance of a valid building permit and work will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approva I. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. • 5. I understand that Itive are required to provide an as-built survey by a licensed land surveyor of a II newly constructed facilities priorto issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: n.¢.y.� / -.A-e2. SIGNATURE: DATE: L/? / d Principle Structure Packet Revised February 2019 Office Use Only FUEL BURNING APPLIANCE & Permit#: ( C--p25�'Zfl ' • ? CHIMNEY APPLICATION Permit Fee:$ Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-7618256 www.queensburynet Project Location: l ALL ?.7 Tax Map ID: 2J 7 Room of Install: 1 r-r,c tr ecxJr1 Planned Install Date: **ONE APPLICATI ON PER APPLIANCE** • CONTACT INFORMATION: • Applicant: Name(s): e cmg-fr.e,ci Mailing Address, C/S/Z: ts�N.Cs�,y i v? 7A ,—•1 i S— Cell Ph.: (cis-- ) Land Line: _( ) Email: • Primary Owner(s): Name(s): SST A-s Mailing Address, C/S/Z: Cell Ph.: _( ) Land Line: _( ) Email: ❑ Check if all work will be performed by homeowner only • Installer/Builder: Workers' Comp documentation must be submitted with this application Contact Name(s): ,?,c b. S Contractor Trade: Mailing Address, C/S/Z: /2.c 7-roc( L A-i-A,.., ,,rLr rZt i v Cell Phone:_( Si's ) 'i- it— Land Line: _(. ) Email: Contact Person for Building & Code Compliance: A)A-6., Cell Ph.: _(S`��f ) Land Line: _( ) Email: ika,4-7 vieuc. --7 r-1, Principle Structure Packet Revised February 2019 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: —Stove _Fireplace Insert Fireplace _Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) Fireplace,factory built** (**Manufacturer's name: l`n,,,,v) Model#: ML DV r- qc.) SOURCE OF HEAT: Wood _Coal _Pellet Gas CHIMNEY INFORMATION: Masonry(require plans to be submitted): block brick stone Flue: tile steel _size, in inches Material*: J( double-wall _triple-wall _insulated (*Manufacturer's name: 1NL924--T6G/-f Model#: ) ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces &chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. 5. Workers' Comp insurance information is required with this application. Declaration:Construction/installation must conform to NYS Fire Prevention&Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: L�C-4,f SIGNATURE: e DATE: r73o/z;ArZv Principle Structure Packet Revised February 2019 • 4 "�` Office Use Only it SEPTIC DISPOSAL PERMIT APPLICATION Permit#: Rc ®Z5�' n Permit Fee:$ : Invoice#: Town ofQeensbury Septic Variance? Yes No 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensburv.net Tax Map ID#: Z S ci , / - / / 7 Pi EI \.1 Project Location: 1 a. I4,4- 2_ iz_N FAT; [ 2U2O AUG 04 • Applicant: TOWN OF OUEENSBURY Name(s): / ,h.r -r a� BUILDINGG --- Mailing Address, C/S/Z: /Sw,fciT>N i12_ /Fr '- P t2 K /mil Lt 12.c. c— Cell Phone: _(S 8 ) 9S-7-S 7 (2_ Land Line: _( ) Email: A-hAc-M e [ZG-lt?ca Sc7-r , cc) • Primary Owner(s): Name(s): ,A- 4 / 2&c.4--tznc Mailing Address, C/S/Z: /5--14. 7r_ ).--( wiz /rives f I-L lI (-( /2..0 .- Cell Phone:_(g7e6) cc7-0-7 / 7 Land Line: _( ) Email: �,a.a---r (62_. 12 <4-2o C i---1,. e e-1- T ❑ Check if all work will be performed by homeowner only • Contractor: Workers' Comp documentation must be submitted with this application Contact Name(s): 7Zc.)SE(.../_,c,c.)c .A4)i4-rtc_t .,,€ ac 2 C Contractor Trade: Mailing Address, C/S/Z: /'zc-,2_ c_)c-t 91/4,c(---cnA-t-,c1--/Z> Cell Phone: _( ) Land Line: _( ) Email: A- -,,,_ J TZ6-TzUS'crTr/ . -c-,J.--j • Engineer(s): Name(s): 79Ovs -l4G6- *-- ,zI c)-- Z Mailing Address, C/S/Z: /'/ /c,/Epz is&- % ;)1? C c Cell Phone:_( S"-r ? ) .c- 7 3 c/SG/ Land Line: ( ) Email: Contact Person for Building & Code Compliance: / pry= ,_EC"hA-re k"-- C_) Cell Phone: ( Ste ) 7- € ) i7 _ Land Line: _( ) Email: Septic Application Revised February 2019 RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (circle one) 1981-1991 130 Spa or Hot Tub . Yes No Installed? (circle one) 1992-Present 110 [ ,/ //U L7t11U PARCEL INFORMATION: Topography Flat Rolling Steep Slope %Slope Soil Nature )and —Loam —Clay _Other(explain: Groundwater . At what depth? Bedrock/Impervious material At what depth? tiv siWv g r Domestic Water Supply _Municipal ZWell (if well,water supply from any septic system absorption is Ls )ft.) Percolation Test Rate: per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size /ZSt) gallons(min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length ft.; Each Trench ft. Seepage Pit with#3 stone How many: ;Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size ;#of tanks NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved.The installed system must match the septic layout on file—no exceptions. 3. As-built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: DATE: "7l-S f/Zc..) SIGNATURE: DATE: —7/5(AC-)2-6 Septic Application Revised February 2019 e W Generated by RESchecksWeb Software Compliance Certificate Project Leonardo Residence Energy Code: 2018 IECC Location: Glens Falls, New.York Construction Type: Single-family Project Type: New Construction FILE COPY Orientation: Unspecified Conditioned Floor Area: 1,270 ft2 Glazing Area 25% Climate Zone: 6 (7635 HDD) REVIEWED FOR E Permit Date: I�ERV IODE Permit Number: C V I .C1 Rat- SCE Construction Site: Owner/Agent: Designer/Contractor: 12 Hall Road Extension Adam Leonardo Walter VanDeLoo, PE Queensbury, NY 12 Hall Road, Ext Walter VanDeLoo, P.E., P.C. Queensbury, New York Po Box 5142 518-857-8712 Albany, New York 12205 adam@rgrosetti.com waltervandeloo.pe@gmail.com Con gIiance Passes usThg yA tr e-o: Compliance: 4.2%Better Than Code Maximum UA: 331 Your UA: 317 The%Better or Worse Than Code-Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies. . ..Gross Area °Aseof rcavity. Cpnt U-Factor UA ° Perimeter '�/alue 12 Value Main Ceiling: Cathedral Ceiling (no attic) 357 42.0 0.0 0.025 9 Loft Ceiling: Cathedral Ceiling (no attic) 576 42.0 0.0 0.025 14 First Floor Rim Bd.:Wood Frame, 16" o.c. 122 21.0 0.0 0.057 7 Orientation: Unspecified FF Walls: Wood Frame, 16"o.c. 1,235 21.0 7.0 0.039 32 Orientation: Unspecified Door:Solid Door(under 50%glazing) 21 0.167 4 Orientation:Unspecified Door 1 Glass Door(over 50%glazing) 42 0.290 12. Orientation: Unspecified FF Windows:Vinyl Frame 73 0.290 21 Orientation:Unspecified -` OF � . Gable Windows:Vinyl Frame / /��F- U') 274 0.290 79 Orientation: Unspecified r 7'\?'P\,ZE.R vA 'De O; Second Floor Rim: Wood Frame, 16" o.c. / F. �i 74 21.0 0.0 0.057 4 Orientation: Unspecified f i 1 r : * SF Walls:Wood Frame, 16"o.c. / s i ,+ 570 21.0 7.0 0.039 19 Orientation: Unspecified Window Vinyl Frame ti n f. >,t 84 0,290. 24 Orientations Unspecified C,` \ cr",, i e44,:�,aa `'" " r 061550 v� -dam ` ° Q �� 243 21.0 7,0 0.039 6 Project Title: Leonardo Residence " p ©Ft �lU�f� . Report dater 06/17/20 Data:filename: r, .. Page 1-of10 .G Gross Area Cavity Cont. • Assembly or R-Value R-VaLue U-Factor UA Perimeter Door: Glass Door(over 50%glazing) 42 0.290 12 Orientation: Unspecified Window 1:Vinyl Frame 36 0.290 10. Orientation: Unspecified Floor:Slab-On-Grade(Unheated) 27 10.0 0.480 13 Insulation depth: 4.0' Basement: Solid.Concrete or Masonry 855 15.0 0.0 0.054 45 Orientation: Unspecified Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Window:Vinyl Frame 20 0.290 6 Orientation: Unspecified Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC=requirements in REScheck Version: REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name-Title Signature Date Project Title: Leonardo Residence Report date: 06/17/20 Data filename: Page 2 of10 . igia RES check Software Version : R.EScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 2.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the:REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented,.or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section • Plans,Verified Field Verified, -•. Pre Inspection/Plan Review -. d Complies? Comments/Assumptions Value Value- = 103.1, Construction drawings and i❑Complies 103.2 documentation demonstrate ' ❑Does Not [PR1.]1 energy code compliance for the, ❑Not Observable 9) building envelope.Thermal envelope represented on DNot Applicable construction documents. ' r` f 103.1, Construction drawings and 1 11:1Complies 103.2, documentation demonstrate Oboes Not 403.7 energy code compliance for [PR3]i lighting and mechanical systems. ❑Not Observable t Systems serving multiple ONot Applicable dwelling units must demonstrate compliance with the IECC , Commercial Provisions. 302,1, ;Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 ;sized per ACCA Manuals based Btu/hr Btu/hr DDoes Not. [PR212 ton loads calculated per ACCA Cooling: Cooling: ONot Observable 4 Manual.J or other methods Btu/hr Btu/hr approved by the code official. ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) ;.2";Medium Impact(Tier 2) I:3 1 Low Impact(Tier 3) Project Title: Leonardo Residence Report date: 06/17/20 Data filename: Page 3 of10 Seetibn Plans Verified Field Verifie!' # Faundafion Inspection Value Uafue, Complies? Comments/Assumptions & Reg:ID. 4023..2 Slab edge insulation ft-value. R- R- ❑Complies See the Envelope Assemblies [F01]1 ❑ Unheated ❑ Unheated ❑Does Not table for values. ❑ Heated ❑ Heated ❑Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [F03]1 depth/length. ❑Does Not table for values. ❑Not Observable ❑Not Applicable 402.1.1. Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. ; ). ,insulation is used,verification ;may need to occur during ❑Not Observable. ;Insulation Inspection. Not ❑Not-Applicable ;required in warm-humid locations l in Climate Zone 3. 303.2 ;Conditioned basement wall 1❑Complies [F05]1 ;insulation'installed per '❑Does Not !manufacturer's instructions. !❑Not Observable ;l Not Applicable 402.2.9. Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of" burial or ❑Does Not table for values. 14 distance from top of wall. ❑Not Observable. ❑Not Applicable 303.2.1 ':,A protective covering is installed t❑Complies {F91112 ;to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable minimum of in. below grade. ; ;❑Not Applicable 403.9: ;Snow-and ice-melting system ;❑Complies Exception: Requirement is (FQ,12)2 controls installed. ;❑Does Not not applicable. 3 i j❑Not'Observable - 1 '❑Not Applicable Additional.Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3, Low Impact(Tier 3) Project Title: Leonardo Residence Report date: 06/17/20 Data filename: Page 4:of10 . ._.1 liSection:- Plant Verified , Field Verified , ,.# Frarnin0[Rough-An lnspectlititi - - vafuel - v_i : - , a ue, riiinplies1 'Coraments/AsturnpVpris „St Fteti.ID 402.1.1, Door U-factor. U- U- 0Complies See the Envelope Assemblies 402.3.4 ElDoes Not table for values. [FR1]1 ONot Observable 4 ONot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- 0Cornplies See the Envelope Assemblies 402.3.1, average). I:Does Not table for values. 402.3.3, 402.5 CINot Observable (FR2)1 ONot Applicable :01 1 _ 303.1.3 ;U-factors of fenestration products - ElComplies , , [FRO ;are determined in accordance, „•-• I--iDoes Not a ;with the NFRC test procedure or ',". ' ' ' '', • •• , ' :' , ,, ;taken from the default table. ONot Observable ,IIINot Applicable 402.4.1.1 ;Air barrier and thermal barrier ' ' ' ': DComplies [FR23]1 ;installed per manufacturer'sODoes Not :P.) ;instructions, ONot Observable ." iLINot Applicable 402.4.3 Fenestration that is not site built . , ,1=1Cornplies [FR20)1 is listed and labeled as meeting ,,-, IL1Does Not AAMA/WDMA/CSA 101/l.S.2/A440 or has infiltration rates per NFRC I10Not Observable 400 that do not exceed code 1:1Not Applicable limits. . , _ , , .,__, 402.4.5 .;IC-rated recessed lighting fixtures _ ILIComplies [FR16]2 Isealed at housing/interior finish ir--, • ILJDoes Not :and labeled to indicate s2.0 cfm 'leakage at 75 Pa. ' IONot Observable , '11DNot Applicable 403.3.1. ;Supply and return ducts in attics il=1Complies , [FR12]3: ;insulated >= R-8 where duct is . , 1 sODoes Not , r4v, >= 3 inches in diameter and >= , R-6 where< 3 inches.Supply and ,• IDNot Observable return ducts in other portions of 1:1Not Applicable the building insulated >= R-6 for , ' diameter>= 3 inches and Ft-4.2 '''' - ' ,.. - • for< 3 inches in diameter. 403.3.2 ;Ducts, air handlers and filter , IDComplies [FR13]1 ;boxes are sealed with ;1:11Dbes Not , 14 ijoints/ eams compliant with • ' ';International Mechanical Code or . ['Not Observable• ° , ;International Residential Code, as ONot Applicable ;applicable. • I 4153.33 ,;Building cavities are not used as '-, "414, •:-.-?-3..`147:;-'"-. '`•:";-",:':-:•,.."-:."P";"73,1Ail=1Complies [F41.15p ;ducts or plenums. ,•„,,., ,,,j,„%-%,,y,sown, ---; ..,--E-glx,e4: , 1 .(71, .;:" --,.. "1. - Does Not 4 .1 -.• ,::.>t,4.7,,-.:- --'-',4--Nd-' .- ,.. ,...,,,..-x4,44 [Not Observable J, ADNot Applicable 1 High Impact(Tier 1) -2' Medium Impact(Tier 2) 3,1 Low Irnpact(Tier 3) _ Project Title: Leonardo Residence Report date: 06/17/20 Data filename: Page,5 of10 • Section ., Rlans Verified IFielii'Verified) # Framing/ Rough-In�Ins'pection - Complies? Comments/Assurriptions. '&,kap.1D _ Value Value 403,37 Ducts declared to be within the l❑Complies [FR2013 ;conditioned space are either 1) kDDoes Not completely within the continuous i �A ❑Not Observable. air barrier and within the building ;thermal envelope 2) buried , f. ❑Not Applicable within ceiling insulation in ��,; .i,� , , accordance.with Section y R403.3.6 and the air handler is ` located`completely within the j continuous air barrier and within ;the building thermal envelope ;and the duct leakage is <= 1.5 cfm/100`square feet of !conditioned floor area served by ;the duct system,or 3)the-ceiling ;insulation R-value installed :against and above the insulated • 'duct>=to the proposed ceiling 4 ;insulation R-value, less the R- value of the insulation on the 403.4 ;HVAC piping conveying fluids R- R- ❑Conmplies [FR1712 ,above 105 °F or chilled fluids ❑Does.Not below 55 QF are insulated to >_R= .fit ,3 ❑Not Observable ❑Not Applicable 403.4.1 ;Protection of insulation on HVAC ❑Complies [FR24]1 'piping. . ❑Does Not ,J ;❑Not Observable 10Not Applicable 403 53 ;Hot water pipes are insulated to. R= R- ❑Complies [FR1$i]2 ;?_R-3. ❑Does Not , , ❑Not Observable • ❑Not Applicable 403:6. ;Automatic or gravity dampers are ,DComplies [FR19]2 •installed,on all outdoor air 1❑Does Not intakes and exhausts.. ❑Not Observable 1❑Not Applicable Additional Comments/Assumptions: • 1 High Impact(Tier 1) `2 Medium Impact(Tier 2) 3, Low Impact(Tier 3) Project Title: Leonardo Residence Report date: 06/1.7/20 Data filename: Page 6 of10 'Section Plans Verified Field Verified - #' Insulation Inspection Complies? Comments/Assumptions Req,lp Value Value,3.03.1 ;All installed insulation is labeled ' j❑Complies [IN13]? sorthe installed R-values i❑Does Not !provided, ❑Not Observable ❑Not Applicable 402.1.1, ;Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, !mass wall with at least'/2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 (wall insulation on the.wall ❑ Mass 0 Mass [IN3]1 ;exterior, the exterior insulation ['Not Observable 1 requirement applies (FR10). 0 Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ' (❑Complies [INC' manufacturer's instructions. 10Does Not i❑Not Observable l❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2! Medium Impact(Tier 2) 3 ' Low Impact(Tier 3) Project Title: Leonardo Residence Report date: 06/17/20 Data filename: Page 7 of10 Section Plans Verified Field Verified & Re ID Final Inspection.Provisions Value Complies?` Comments/Assumptions. Value 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402:2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.E[Flip Not Applicable A plicable 303.1.1.1„Ceiling insulation installed per gg ;10Complies 303.2 !manufacturer's instructions. ! ��° in-Does Not [FI2]1 ;Blown insulation marked every INot Observable 300 ft2. i '❑Not Applicable 402.23 'Vented attics with air.permeable ;❑Complies [F122]2 !insulation include baffle adjacent i I❑Does Not to soffit and eave vents that 'extends over insulation. s❑Not Observable ;❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable _ 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total ❑Not Observable leakage measured with a pressure differential of 0..1'inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.4 ;Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 ;cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ;handler @ 25 Pa. For rough-in ['Not Observable ;tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated f • {❑Complies [FI24]1 !by manufacturer at<=2%of ' IDDoes Not !design airflow. i I ; .I❑Not Observable ! r I❑Not Applicable 403.1.1 I Programmable thermostats ; i''" ' `❑Complies [Fl9]''- i installed for control of primary :,7 3, „_l - - -s, a, ❑Does Not !heating and cooling systems and i initially set by manufacturer to 'im4 c ;; ,❑Not Observable ;code specifications. �: , l❑Not Applicable `403.1.2 ;Heat pump thermostat installed , x i '}'1❑Complies (F11'012 'on heat pumps. 4❑Does Not t❑Not Observable I i IDNot Applicable 403.5.1 :Circulating service.hot water j (((((❑Complies (F111]z' ;systems have automatic or I I❑Does Not I accessible manual controls. ❑Not Observable • I i❑Not Applicable • Ll High Impact(Tier 1) 2: Medium Impact(Tier 2) 13 I Low Impact(Tier 3) Project Title: Leonardo_Residence Report date: 06/17/20 Data filename: Page 8 of10 ,.... , • ., Plans Vdtified" Field'vrerified complies?' Cbmnients/Assumptions ,, i va up '''SeCiirmi IlbsPebtiork PrOVisi°hs- ValLte_ ARect,ID" -,...r,Z4z Opees Not § 1. j All mechanical ventilation system [21115.J.2.' Ifans not part of tested and listed '" • „ '', ,:„.„.,,,,*,00 ,•,,, '''''''; ' ''' '' li,-,.> ' i-i l'cable ;HVAC equipment rrieet efficacy ' '' OLINCOtril0Pbliseesrvable 'and air flow limits per Table , , ,'' - 4';','..„44,14:"' ", .:,:'1:fzet„1,,.*:-'' L_,Not App i jR403.6.1. ..,' '' " " j„.,„- ,,,,,,423,4:7,' 'Ocomplies ''' ' '' ' '''' ".* OD es Not ;Hot water boilers supplying heat " , ,,--j„.,.., 0 al? 'I ,_ n one-or two-pipe heating ' 26iz 1 through(.FI ,- ;contsystems have outdoor setback ,•,.., , ,DIDNNoott Applicable rol to lower boiler water r ture based on outdoo,tempera ; !temperature. , ) ,-, Does Not 4Ci15.1.1 I Heated water circulation systems 1=IComplies ,. EFI2812' ":have a circulation pump.The iLi Y ;EINot 1 tem return pipe is a dedicated 1 .sretsurn pipe or a cold water suPPIY I Observable pipe. Gravity and thermos- . ,i.._11--'Not Applicable syphon circulation systems are not present. Controls for circulating hot water system m s start the pump with signal fpourhp ot water demand within the ;occupancy. Controls ;automatically turn off the pump ;when water is in circulation loop is' at set-point temperature and. . - ;no demand for hot waterx ts ; . , 403.-5.1.2 ;Electric heat trace system OCombiles s [Fi29-3,2 ;`,,comply with IEEE 515.1 or UL EDoes Not 515. Controls automatically • adjust the energy input to the IHNNoott A0pbpselicrvaabbiele heat-tracing to maintain the ' , desired-water temperature in the piping. . 403.5,.2' ',Demand recirculation water ' jElComblies• : I '.,systems have controls that pump 1 EFI12 1=IDoes Not manage operation of the 'and.limit the temperature,of the -I - I'water entering the cold water , Not water Applicable . . ; , . piping to<= 104P- .F. .1 4,03.5,4 I Drain water heat recovpry units EDCoornespNlieost 1 [Fi31]2 itested in accordance with CSA 1 "E355.1. Potable water-side 111Not Observable I •I ;pressure loss of drain water heat -,. DNot Applicable , ; recovery' units < 3 psi for i I , j individual units connected to one or two showers. Potable " .,. ' side pressure'loss of drain water : . ; heat recovery units < 2 psi for —., ,*," '-'''-*2 I individual units connected to * " .,,, ;three or more showers. -)*'''''''''''.1.- , jfaomplies i ,.,,-;,1i.;,...,,t, ,.c,„.:3---;,,:. .;*-re„.;."'" z-,,-.1141„4„,2"''', - ElDoes Not 404.1 90%or more of permpnent EFI6P fixtures have high efficacy lamps. :iv , ,,,,,,,,,!,,,,,,,..i,,,4 -`,., . DNot Observable - * „,,, DNot44,,, Applicable ,;Fuel gas lighting systems have ' ''';',--',,:',:, : , "- ::4- 111:',:- r'''':'7 "?:I4 .,,.11,T4:-':,_L__Th"D DC P n le sP NotIie s tr123T' i no continuous pilot light. ,LQ) . , liuNot Observable - • '1 ,10Not Applicable ' -- - .- ' ,-: it ' 1OComplies ' 01-7DN:esN tobs°etrvable 401.1,- iCornPliance certificate posted. [F17)2 1 - Not Applicable O . 1 High Impact(Tier 1) i t' Medium Impact(Tier 2) ..3..,;Low Impact(Tier 3) Project Title: Leonardo Residence Report date:p ag0e6/9107/f21.00 Data'filename: Section ' Plans•Verified Field Verified #. Final'Inspection'Provisions Value Value Corri'plies? Comments/Assumptions & Req ID - 303,3 ;Manufacturer manuals for "°• (❑Complies [AIM' mechanical and water heating j❑Does Not i systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2,]Medium Impact(Tier 2) 3., Low Impact(Tier 3) Project Title: Leonardo Residence. Report date: 06/17/20 Data filename: Page 10 of1.0 2018 IECC Energy Effici -, ncy Certificate Insulation:Rating R-Value. Above-Grade Wall 28.00 Below-Grade Wall 15.00 Floor 10.00 Ceiling / Roof 42.00 Ductwork (unconditioned spaces): Glass:&Door Rating U-Factor SHGC Window 0.29 Door 0.29 'Heating&Codling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments Energy Recovery Ventilator 4i_.. , .,J;• Cold Climate ERV Specification Submittal Data /Panasonic ERV Four 4"or 6"ducts Description Architectural Specifications: {1„ Ceiling or wall mount Cold Climate Energy ERV shall be ceiling or wall mount type with � 4g . Recovery Ventilator(ERV)provides a tempered built-in speed selectors for both Supply and �f ;S� air supply,humidity control,and a balanced Exhaust air.Select from 50/60/70/80/100 CFM. \ ,_1.\ amount of exhaust to help maintain balanced, ERV shall have 96 Net CFM on the exhaust odpositive or negative pressure throughout the ports and 98 Net CFM on the supply ports j417 home.Panasonic ERV is engineered for use as tested in accordance with HVI 915 and in any North America climate zone.Only one 916 standards at 0.1 static pressure in inches /(� �� �`I unit is needed for a s 3,000 sq.ft.,up to 7 water gauge.ERV shall have 95 Net CFM on T 1i'� bedroom home to meet the ASHRAE 62.2 the exhaust ports and Net 96 CFM on the m \ ventilation requirement.Built-in ASHRAE 62.2 supply ports at 0.4"w.g.static pressure.Power Timing function helps ensure code compliance. consumption shall be no greater than 64 watts at 0.1°w.g.and 84 watts at 0.4°w.g.static a Motor/Blower: pressure.Apparent Sensible Effectiveness •Two(2)enclosed DC brushless motors rated for heating shall be no less than 88%at 53 for continuous run. CFM net air flow under 32°F(0`C)as tested in FV-1 OVEC1 q tonal Exte"pn-`•''.'Cap Is e' r cu='' •ERV Supply and Exhaust ventilation rates accordance with CSA-C439.Total Recovery shall be manually adjustable for 50-60-70-80- Effectiveness for cooling shall be no less than 90-100 CFM. 65%at 48 CFM net air flow under 95°F(35°C). •Power rating shall be 120 volts and 60 Hz. The supply port damper shall close when EtT F •Motor equipped with thermal cut-off fuse outdoor temperatures are<-22`F(-30°C)to +P :"k control. prevent freezing of the core.The(2)motors y •Removable,permanently lubricated,plug—in shall be totally enclosed DC brushless motors V motor, nl rated for continuous run.DC motor speed shall automatically increase when the fan senses �� . �Housing: static pressure to maintain selected CFM.ERV C /N o_O •22 gauge galvanized steel body. shall incorporate an ASHRAE 62.2 Timing •Four 4°or 6"intake and exhaust ducts, function for code compliance. Power rating shall be 120v/60Hz,Duct diameters shall be no DC Motor Technology •Built in dampers on exhaust and Outdoor Air less than 4".ERV can be used to comply with When the ERV senses static pressure,its ducts for defrost and recirculation cycling. ASHRAE 62.2,Ontario,ENERGY STAR®*and speed is automatically increased to ensure that •Filters on supply and exhaust air extend the .Novoclimat requirements;LEED,IAP,Califomia the desired CFM is not compromised,which life of the ERV core. Title-24,and WA Ventilation Code. allows the ERV to perform as rated. •(4)Pressure ports allow for easy airflow verification. ERV Core Technology: •Pre-drilled mounting bracket can •Indoor and outdoor air passes through accommodate 16°,19",or 24"on center. Panasonic's capillary core technology.This Maintenance: process tempers supply air while:transferring - •MERV 8 filter included;MERV 8(FV moisture and energy. FLO810VE1)and optional MERV 13(FV- •Built in Frost Prevention Mode prevents the FL1310VE1)replacements available. core from freezing.Frost Prevention Mode _ . _ Unobtrusive_alarm.notifies_owner-for=filter __- is-free of-interaction and operateswithout- -.-__ check and maintenance. intervention. Warranty: •DC Motors:6 years from original purchase date •All Parts:3 Years from original purchase date. For complete Installation Instructions visit us.panasonic.com/ventfans Model Quantity Comments Project: Location:. Architect: Engineer: Contractor: Submitted by: Date: Panasonic Eco Solutions North America o°,",""_,° Eco Products Division 'ty Two Riverfront Plaza °mot 2 0 " Newark,NJ 07102 us.panasonic.com/ventfans 'ft,—.,,, VI` cOuS ® This product meets strict energy efficiency guidelines set by Natural Resources emn,a‘ grmE2 Canada and Is ENERGY STAR®certified for the Canadian market only. Panasonic VF17024SS-10VEC1 I rib P--a m it .'''s g! r t a ` i Irk '" FV-10VEC1 _" Energy Recovery Ventilator l rt;}it. Cold Climate ERV Specification Submittal Data /Panasonic ERV (Continued) Performance Curve 4"or 6"duct Specifications:Intelli-Balance 100 FV-10VEC1 1 Static Pressure in inches w.g. 0.1 0.4 0.9 I, Net Exhaust Air Volume(CFM) 96 95 r, Net Supply Air Volume(CFM) 98 96 °'a ,` 9 Power Consumption(watts) 64.0 84.0 3 °7 'vim •Power Rating(V/Hz) 120/60 v 0.6 ° ENERGY STAR®Certified Yes ; os , in ,4 a` 0.4 Energy Performance: Intelli-Balance 100 FV-10VEC1 Ir. 0.3 ° Supply Net Air Flow Power Sensible Apparent Net `" �4 Temperature Consumed Recovery Sensible Moisture 0•2 °C I °F US I CFM (Watts) Efficiency Effectiveness Transfer n Heating 0.1 0 32 25 53 24 81 88 0.8 0 0 32 31 67 34 77 86 0.76 0 20 40 60 80 100 120 0 32 40 86 54 75 83 0.72 Airflow ICFMi -25 -13 27 57 66 65 85 0.7 -25 -13 32 68 84 64 80 0.7 Cooling Total Recovery Efficiency o n❑Net Supply Air 35 95 23 48 16 65 —Net Exhaust Air Optional Accessory Optional Exterior Wall Cap • , ) v's \ 1---:- ..._,, — ,. __ _ __ ._. -wispo, „p ___ , :,;_:.::.4 ,,,-,.....,,-. .„ ,_ , _____ ,__ __„ _ . __ _ . _ _ fit A --. .4000,00••••.'"vsg"10 ''!:" 00' I..-Ai" Exterior Wall Cap FV-WCO4VE1 polypropylene wall cap with styrofoam adaptor allows both exhaust(from the right)and supply(from the left)airflow through a 5.5"-5.75" hole in the building envelope.The dividers inside the bottom portion of the Y shape chamber and the new wall cap help prevent cross contamination. NOTE:FV-WCO4VE1 is NOT recommended for use at CFM settings higher than 50 CFM. Panasonic Eco Solutions North America 00,..,4, Eco Products Division Two Riverfront Plaza Z 0 Newark,NJ 07102 . 1 7 ei' us.panasonic.com/venffans ° .0'' C =maweb.. Ir1 NVI I c us 'This product meets strict energy efficiency guidelines set by Natural Resources Panasonic Ce1fF Canada and is ENERGY STAR',certified for the Canadian market only. VF17024SS-10VEC1 s y • Leonardo R EFfice v HVAC Load C c I for JUN 0 3 202. Adam Leon rdorOWN OF QUEENSBUR 12 Hall Roa Ext. BUILDING&CODES Queensbu 1;- t�` d oftwo. , ,!Egg fre RHVACRESIDENTIAL • HVAC LoADs Prepared By: 289.11-1-17 Arthur Pakatar RC-0255-2020 The Pakatar Group,LLC Leonardo, Adam & Rebecca 120 Defreest Drive,Suite 100 Troy,NY 12180 12 Hall Rd Ext 518-874-1604 SFD w/gas FP 2158 s.f. Thursday, May 28,2020 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. .4 Rhvac-Residential 8 Light Corninercial HVAC Loads Elite Softiivare Devdloprnent,lnc. I'Stonehenge Associates • Leonardo Residence. I Troy,-,NY 12180 Page 2! Project Report General Project friformation 7-1 Project Title: Leonardo Residence — — Designed By: Arthur Pakatar Project Date: Wednesday May 27,2020 Client Name: Adam Leonardo Client Address: 12 Hall Road Ext. Client City: Queensbury, NY Client Phone: 518-872-8712 Client E-Mail Address: adam@rgrosetti.com Company Name: The Pakatar Group, LLC Company Representative: Arthur Pakatar Company Address: 120 Defreest Drive, Suite 100 Company City: Troy, NY 12180 Company Phone: 518-874-1604 Company E-Mail Address: art@thepakatargroup.com LDesign Data -- --- Reference City: Glens Falls, New York Building Orientation: Front door faces West Daily Temperature Range: Medium Latitude: 43 Degrees Elevation: 328 ft. Altitude Factor: 0.988 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: -4 -4.56 n/a n/a 70 n/a Summer: 85 71 51% 50% 75 27 I:Check figLees • --. - Total Building Supply CFM: 1,066 CFM Per Square ft.: 0.448 Square ft. of Room Area: 2,377 Square ft. Per Ton: 828 Volume(ft3): 16,138 Building:Loads_ .Total Heating Required Including Ventilation Air: 75,062 Btuh 75.062 MBH Total Sensible Gain: 23,173 Btuh 67 % Total Latent Gain: 11,286 Btuh 33 % Total Cooling Required Including Ventilation Air: 34,459 Btuh 2.87 Tons(Based On Sensible+Latent) Notes. _ Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM S i IRhvac-"Resideritiaf&Light CommercialHVAC Loads - Elite•Sbftware Development;Inc. Stonehenge Associates Leonardo Residence 1.Troy,NY 12180 !�I%' . .Page.3 Miscellaneous Report System-1 Heating, _ Out'do& Outdoor Outd'g,or In'do`or Indoo Gra r ins _Input'Date Diy,B:ulb' Wet;BuIb Rel Hum Rel'Hum' ___ D y Bulb Difference Winter: -4 -4.56 80% n/a 70 n/a Summer: 85 71 51% 50% 75 27.41 I DuctSizing Input's- -— • - -- _• -- - _.__- Main Trunk Runouts� Calculate: Yes Yes Use Schedule: No No Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. OutsideAii Data — �! Winter Summer Infiltration Specified: 0.110 AC/hr 0.060 AC/hr 30 CFM 16 CFM Infiltration Actual: 2.280 AC/hr 2.278 AC/hr Above Grade Volume: X 16,138 Cu.ft. X 16,138 Cu.ft. 36,792 Cu.ft./hr 36,761 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 613 CFM 613 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 10.87 = (1.10 X 0.988 X 10.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 18.42 = (0.68 X 0.988 X 27.41 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 80.44 = (1.10 X 0.988 X 74.00 Winter Temp. Difference) Winter Infiltration Specified: 0.110 AC/hr(30 CFM), Construction:Tight, Fireplaces: 1, 0 CFM, Tight Summer Infiltration Specified: 0.060 AC/hr(16 CFM), Construction: Tight Chilled,and Hot Water Flow Rates-System1 _ Cooling GPM = -34,459 /( 30.00 x 500 ) = 2.30 GPM Heating GPM = 75,062 /( 30.00 x 500 ) = 5.00 GPM C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM .ay E cu �_ GG CD co Q I ,C N rE M N cS n- N •- .- N e- N I r .- co .- Q lii CM COCO 04 �,J 2)2 co co CO O 0) •d' N CO 0 CO CO N N t0 O N OS U to (fOO ccpO tCOO pp •c} �p >, co 2 L�1. E OM) OCC)) Iz N 8 CO 3 N m N O - C7 09 N rs fh as - WI U �p (((V�p CQD� p p coNMI W CO.O.I C.I. o N W cnt)_ V: N el in cv sr a) [+C�)_ V N C+M)_ cN) t-3. N. c')) 7 tf� l(� cp L ZI— . (0 CD M O N W 2 n — c0 W M O V R h. co c M O U) (V a0 . N- O C cCpp cCpp A N V e-- t1) C co N _ C oO e0 C to O O V CV CO v O N CO � d' N - g N . N N 4. CA N CO ti 05 N v_ Cr N N d) N e- N • N - .^- 0) 01 r CO m R Cn (1) i� Nh m N CO g CO v m N N N .- CV se N N .- CC) 1� 0- N. V' pC. O lO LO N V O CD CO N 7 to V �' he. m N. N cr V' CO CO CO M CO CD tO M 0.1 Q m co N N N' N CO CO CO ZO NV CO Cn F CV H :NO' O• Q :co' V 0) •o. . 0 U Q ai .p) U J C a) as w a) o o CC A N"N L G $ H E '0 � ,�� rn E $ o M LL a _ d Eo O to a c o C v `d' tl IO.Q H 4) cl J O v S N m C� ND� > > 2 .d cci td Ncj m Nn N ch 4 tb m 00 05 a e Rhvac,-Residential&Light,Commercial HVAC'Loads• Elite Software Developmer t,;inc. Stonehenge Associates Leonardo Residence, .Troy,NY 12180 ' - Pa- e 5 Duct Size Preview Room or Source I Minimum Maximum Rough. Design' SP Duct Duct Htg Clg Act. Duct Duct Name Vebciy Vebciy Factor U100I Loss Vebc�ty Length Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Bedroom 2 Built-In 0 750 0.01 0.1 343.9 71 P- 68 68 1-6 2-Great Room Built-In 0 750 0.01 0.1 424.8 2041, T1116 116 2-5 3-Bath#2 Built-In 0 750 0.01 . 0.1 296.4 30 r '`` 15: 15 1-3 4-Mech Room Built-In 0 750 0.01 0.1 334.7 61 i g;II.29 29 1-4 5-Bedroom 3 Built-In 0 750 0.01 0.1 300.6 44 r-`K^41I 41 1-5 6-Upper Family Room Built-In 0 750 0.01 0.1 372.3 84�~199 199 2-7 7-Upstairs Bath Built-In 0 750 0.01 0.1 313.4 19 t , 15 15 1-3 8-LoftSleepingArea Built-In 0 750 0.01 0.1 324.8 126 -_'l 128 128 2-6 9-Hall @ Stairs Built-In 0 750 0.01 0.1 0 0[ 0' 0 1-0 10-Entry Hall Built-In 0 750 0.01 0.1 268.1 171 ` 13 13 1-3 11-lOtchen Built-In 0 750 0.01 0.1 2062 31 l_^_18 18 1--4 12-Family Room(Lover) Built-In 0 750 0.01 0.1 401.9 189[ "322 322 3-7 13-Stair Well Built-In 0 750 0.01 0.1 231 24 20' 20 1-4 14-Bath#1 Built-In 0 750 0.01 0.1 300.9 17 if 15. 15 1-3 15-Bedroom 1 Built-In 0 750 0.01 0.1 343.9 71[ "6868 1-6 Other Ducts In System 1 Supply MainTruik Built-In 0 900 0.003 0.1 799.4 986i 1,066 1,066 12x16 Summary • System 1 Heating Flow: 986 Cooling Flow: 1066 C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM i Rhvac,-Residential&Light Commercial HVAC Loads Elite'Softwa_re Development;Inc. Stonehenge Associates. '. ' Leonardo Residence Troy;NY 121'80- _.d P,age 6. Total Building Summary Loads Component Area: Seh' 'Lat.- - ,Sen Total i Description,. __ Quan' Loss _ Gain_ Gain Gain V01: Glazing-Typical Vinyl Windows, u-value 0.28, SHGC 457 9,468 0 10,505 10,505 0.27 11 P: Door-Metal-Polyurethane Core 21 451 0 128 128 12F-0sw:Wall-Frame, R-21 insulation in 2 x 6 stud 1037.9 4,994 0 696 696 cavity, no board insulation, siding finish, wood studs 15A15-0ocw-2:Wall-Basement, , framing with R-15 sill to 565 3,520 0 262 262 floor in 2 x 4 cavity, open core, no board insulation, plus interior finish, wood studs, 2'floor depth 15B11-0w-2: Wall-Basement, ,framing with R-11 sill to 182.8 1,248 0 88 88 floor in 2 x 4 cavity, core, no board insulation, plus interior finish, wood studs, 2'floor depth 15B13-0m-6: Wall-Basement, , framing with R-13 sill to 203 1,134 0 30 30 floor in 2 x 4 cavity, core, no board insulation, plus interior finish, metal studs, 6'floor depth . 18A-38: Roof/Ceiling-Roof Joists Between Roof Deck 1137.6 2,443 0 561 561 and Ceiling or Foam Encapsulated Roof Joists, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, R-38 blanket or loose fill CustomFloor4: Partition Floor(STD=1, WTD=1)- 247.2 248 0 248 248 Basement, Custom, Wood Floor over Basement 21 B-24-c: Floor-Basement, Concrete slab, any thickness, 571 719 0 0 0 2 or more feet below grade, R-3 or higher insulation installed below floor, carpet covering, shortest side of floor slab is 24'wide 22B-10ph: Floor-Slab on grade, Vertical board insulation 24 854 0 0 0 covers slab edge and extends straight down to 3' below grade, any floor cover, R-10 insulation, passive, heavy moist soil 21A-24-c: Floor-Basement, Concrete slab, any thickness, 205 379 0 0 0 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24'wide 21B-24-c: Partition Floor(STD=1, WTD=1)-Basement, 1017.6 17 0 17 17 Concrete slab, any thickness, 2 or more feet below grade, R-3 or higher insulation installed below floor, carpet covering, shortest side of floor slab is 24'wide Subtotals for structure: 25,475 0 12,535 12,535 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 613, Summer CFM: 613 49,325 11,286 6,660 17,946 Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0 Exhaust: Winter CFM: 612, Summer CFM: 612 Hot Water Piping, 10 ft.Total: 262 0 0 0 AED Excursion: 0 0 3,978 3,978 Total Building Load Totals: 75,062 11,286 23,173 34,459 Check Figures. _, I Total Building Supply CFM: 1,066 CFM Per Square ft.: 0.448 Square ft. of Room Area: 2,377 Square ft. Per Ton: 828 Volume(ft3): 16,138 Efuildirig Loads, . Total Heating Required Including Ventilation Air: 75,062 _Btuh , 75.062 MBH Total Sensible Gain: 23,173 Btuh 67 % Total Latent Gain: 11,286 Btuh 33 % C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvat.-gesidentiat&Light Commercial HVAC Loads Elite Software Development,:lnc; Stonehenge.Associates ' Leonardo Residence Troy,NY 12180. -.fl _ Page 7 Total Building Summary Loads (cont'd) LBuildir Loads Total Cooling Required Including Ventilation Air: 34,459 Btuh 2.87 Tons(Based On Sensible+ Latent) Notes -_ _- - Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. • C:1...1Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Residential&Light Commercial HVAC Loads EliteSoftiniare.Development,Inc: Stonehenge Associates Leonardo Residence Troy,NY 12180 Page:8, Building Pie Chart • C:\...\Leonardo Residence.rh9 Thursday, May 28,2020, 11:43 AM -. ,Rhdac-Residential&Light Comrriercial HVAC;Loads•- _- -- --- " -_ ' .. Elite:Software.Development,Inc. Stonehenge Associates Leonardo Residence j i Troy,,NY 12.180 • Page'9_J System I Heating Summary Loads Component Area' ',Seri -Lat - $en' - _ - Total, Description Quan' .. Loss- _, Gain: Gain : ; 'Gain_' V01: Glazing-Typical Vinyl Windows, u-value 0.28, SHGC 457 9,468 0 10,505 10,505 0.27 11 P: Door-Metal -Polyurethane Core 21 451 0 128 128 12F-Osw:Wall-Frame, R-21 insulation in 2 x 6 stud 1037.9 4,994 0 696 - 696 cavity, no board insulation, siding finish, wood studs 15A15-0ocw-2: Wall-Basement, , framing with R-15 sill to 565 3,520 0 262 262 floor in 2 x 4 cavity, open core, no board insulation, plus interior finish,wood studs, 2'floor depth 15B11-0w-2:Wall-Basement, , framing with R-11 sill to 182.8 1,248 0 88 88 floor in 2 x 4 cavity, core, no board insulation, plus interior finish, wood studs, 2'floor depth 15B13-Om-6: Wall-Basement, , framing with R-13 sill to 203 1,134 0 30 30 floor in 2 x 4 cavity, core, no board insulation, plus interior finish, metal studs, 6'floor depth 18A-38: Roof/Ceiling-Roof Joists Between Roof Deck 1137.6 2,443 0 561 561 and Ceiling or Foam Encapsulated Roof Joists, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, R-38 blanket or loose fill CustomFloor4: Partition Floor(STD=1, WTD=1)- 247.2 248 0 248 248 Basement, Custom, Wood Floor over Basement 21 B-24-c: Floor-Basement, Concrete slab, any thickness, 571 719 0 0 0 2 or more feet below grade, R-3 or higher insulation installed below floor, carpet covering, shortest side of floor slab is 24'wide 226-10ph: Floor-Slab on grade, Vertical board insulation 24 854 0 0 0 covers slab edge and extends straight down to 3' below grade, any floor cover, R-10 insulation, passive, heavy moist soil 21A-24-c: Floor-Basement, Concrete slab, any thickness, 205 379 0 .0 0 2 or more feet below grade, no insulation below floor, carpet covering, shortest side of floor slab is 24'wide 21B-24-c: Partition Floor(STD=1, WTD=1)-Basement, 1017.6 17 0 17 17 Concrete slab, any thickness, 2 or more feet below grade, R-3 or higher insulation installed below floor, carpet covering, shortest side of floor slab is 24'wide - _ Subtotals for structure: 25,475 0 12,535 12,535 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration:Winter CFM: 613, Summer CFM: 613 49,325 11,286 6,660 17,946 Ventilation:Winter CFM: 0, Summer CFM: 0 0 0 0 0 Exhaust:Winter CFM: 612, Summer CFM: 612 Hot Water Piping, 10 ft. Total: 262 0 0 0 AED Excursion: _ _ _0 0 3,978 3,978 _ System 1 Heating Load Totals: 75,062 11,286 23,173 34,459 Check Figures _ _ _ . _. __ ____ _ ' Supply CFM: 1,066 CFM Per Square ft.: 0.448 Square ft. of Room Area: 2,377 Square ft. Per Ton: 828 Volume(ft3): 16,138 .System Loads; Total Heating Required Including Ventilation Air: 75,062 Btuh 75.062 MBH Total Sensible Gain: 23,173 Btuh 67 % Total Latent Gain: 11,286 Btuh 33 % C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Residential&:Light CommercialHVAC Loads Elite:Softwaie Development,lnc. •Stonehenge•Associates Leonardo Residence T,roy,NY 121'80 • . Page 10;I System I Heating Summary Loads (cont'd) System•L'oads _ Total Cooling Required Including Ventilation Air: 34,459 Btuh 2.87 Tons (Based On Sensible+ Latent) Notes - - -. Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. • C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac Regideritialli Light Cortirrierbidi HVAC Lci,add 'E I ife Sbfa-1-06DelielOprtiertiti Inc, Sinriphenge ASs--tiOteS- Leonardo Residence Troy;NY 121,8-0 . Page 11 j System 1 Heating Pie Chart • C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Residential&Light Commercial,HVAG Loads • EliteSoftware'D'evelopment,'Inc.1 Stonehenge Associates ,� Leonardo Residence,) Troy,NY 121:80' 1i Page 12 Manual S Performance Data - System 1 - Heating _Loads arid.Design:Coriditions; _ Cooling: Outdoor Dry Bulb: 0 Sensible Gain: 23.173 Outdoor Wet Bulb: 71 Latent Gain: 11.286 Indoor Dry Bulb: 75 Total Gain: 34.459 Indoor RH: 50 Load SHR: 0.67 Supply Airflow: 0 Entering Dry Bulb: 0 Entering Wet Bulb: 0 Heating: Outdoor Dry Bulb: -4 Sensible Loss: 75.062 Indoor Dry Bulb: 70 Entering Dry Bulb: 70.0 • Indoor RH: 30 Supply Airflow: 986 Effeluip_Ment Performance Data at System Design.Conditions ' Cooling: Model Type: Standard Air Conditioner, Model: ASX140481 K*+CSCF4860N6D*+TXV, Nominal Capacity: 45.500, Manufacturer:AMANA Interpolation Results: Percent Load of Load Sensible Capacity: 0.000 23.173 0% • Latent Capacity: 0.000 11.286 0°/v Total Capacity: 0.000 34.459 0% • Heating: Model Type: Propane Boiler, Model: NHB-055, Nominal Capacity: 51.000, Manufacturer: NAVIEN, INC. Results: Percent Load of Load • Heating Capacity: 51.000 75.062 68% C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM •Rhvac-Residential;&,Lighfeeminerciel HVAC-Loads - - - -- _ -- Elite Softwaie Development;Inc. Stonehenge Associates Leonardo-Residence Troy,NY •12180•. ,IC� _ , . • . - Page:13 1 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) ;;Component Area . Sen Of - Sen -'Total{ escription. _ ________ _ ' - _.Quart__ _ Loss j _ Gain- ' Gai ' Gain V01: Glazing-Typical Vinyl Windows, u-value 0.28, SHGC 457 9,468 0 10,505 10,505 0.27 11 P: Door-Metal-Polyurethane Core 21 451 0 128 128 12F-0sw:Wall-Frame, R-21 insulation in 2 x 6 stud 1037.9 4,994 0 696 696 cavity,no board insulation, siding finish, wood studs 15A15-0ocw-2:Wall-Basement, ,framing with R-15 sill to 565 3,520 0 262 262 floor in 2 x 4 cavity, open core, no board insulation, plus interior finish, wood studs,2'floor depth 15B11-0w-2:Wall-Basement, , framing with R-11 sill to 182.8 . 1,248 0 88 88 floor in 2 x 4 cavity, core, no board insulation, plus interior finish,wood studs, 2'floor depth 15B13-0m-6:Wall-Basement, ,framing with R-13 sill to . 203 1,134 0 ' 30 30 floor in 2 x 4 cavity, core, no board insulation, plus interior finish, metal studs, 6'floor depth 18A-38: Roof/Ceiling-Roof Joists Between Roof Deck 1137.6 2,443 0 561 561 and Ceiling or Foam Encapsulated Roof Joists, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark • Membrane, Dark Tar and Gravel, R-38 blanket or loose fill CustomFloor4: Partition Floor(STD=1, WTD=1)- 247.2 248 0 248 248 Basement, Custom,Wood Floor over Basement 21B-24-c: Floor-Basement, Concrete slab, any thickness, 571 719 0 0 0 2 or more feet below grade, R-3 or higher insulation installed below floor,carpet covering, shortest side of floor slab is 24'wide 22B-10ph: Floor-Slab on grade, Vertical board insulation 24 854 0 0 0 covers slab edge and extends straight down to 3' below grade,any floor cover, R-10 insulation, passive, heavy moist soil 21A-24-c: Floor-Basement, Concrete slab, any thickness, 205 379 0 0 0 2 or more feet below grade, no insulation below floor, carpet covering,shortest side of floor slab is 24'wide 21B-24-c: Partition Floor(STD=1,WTD=1)-Basement, 1017.6 17 0 17 17 Concrete slab, any thickness, 2 Or more feet below grade, R-3 or higher insulation installed below floor, carpet covering, shortest side of floor slab is 24'wide Subtotals for structure: 25,475 0 12,535 12,535 People: 0 0 0 0 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration:Winter CFM:613, Summer CFM: 613 49,325 11,286 6,660 17,946 System 1,Zone 1 Load Totals: 74,800 11,286 23,173 34,459 Check'_Figures; Supply CFM: 1,066 CFM Per Square ft.: 0.448 Square ft.of Room Area: 2,377 Square ft. Per Ton: 828 Volume(ft3): 16,138 _Zone_Loads • - _ _ _ '_ Total Heating Required: 74,800 Btuh 74.800 MBH Total Sensible Gain: 23,173 Btuh 67 % Total Latent Gain: 11,286 Btuh 33 % Total Cooling Required: 34,459 Btuh 2.87 Tons(Based On Sensible+ Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. C:\...\Leonardo Residence.rh9 Thursday, May 28,2020, 11:43 AM • Rhvac=ReSidehtiah&Light"Commercial HVAC'Loads - Elite:Software pevelopmerit;Inc:. Stonehenge Associates Leonardo Residence Troy,NY 12180. Page 14_ System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) (cont'd) ,Notes_ _ -- All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM I:Rhvac=Residential'&light Commercial HVAC Loads Elite Software Development,lnc.I Stonehenge Associates ›. Leonardo Residence Troy:NY 1214 _. ..•_ P,ages15.I Detailed Room Loads - Room 1 - Bedroom 2 (Average Load Procedure) General-- Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 10.8 ft. • System Number: 1 Room Width: 11.5 ft. Zone Number: 1 Area: 123.6 sq.ft. Supply Air: 68 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.1 AC/hr Volume: 989 cu.ft. Req. Vent. Clg: 0 CFM . Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 68 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 344 ft./min. Percent of Supply: 0 % Runout Air Velocity: 344 ft./min. Actual Winter Infil.: 52 CFM Actual Loss: 0.076 in.wg./100 ft. Actual Summer Infil.: 52 CFM 'Item — _ —Area• U--_ Htg; -- 'Seri i Gig _Lat- Sent Description Quantity Value 'HIM: . Losss __HIM _'Gain Gain I N -Wall-12F-Osw 11.5 X 8 92 0.065 4.8 443 0.7 0 62 E'-Wall-12F-0sw 10.8 X 8 71 0.065 4.8 342 0.7 0 48 E-GIs-V01 shgc-0.27 0%S 15 0.280 20.7 311 28.1 0 421 Floor-Part-CustomFloor4 11.5 X 123.6 1.000 1.0 124 1.0 0 124 10.8 Subtotals for Structure: 1,220 0 655 Infil.:Win.: 51:7, Sum.: 51.6 178 23.354 4,157 3.152 951 561 Ductwork: 0 0 AED Excursion: 252 Room Totals: 5,377 951 1,468 • C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM •Rhvac-Residential,&Light Commercial HVAC Loads - Elite Software Development,Inc. Stonehenge.Associates Leonardo Residence, Troy;NY 12180 - Page;16 Detailed Room Loads - Room 2 - Great Room (Average Load Procedure) 'General _! • Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 20.0 ft. System Number: 1 Room Width: 24.0 ft. Zone Number: 1 Area: 480.0 sq.ft. Supply Air: 116 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.8 AC/hr Volume: 3,840 cu.ft. Req.Vent. CIg: 0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 58 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 425 ft./min. Percent of Supply: 0 % Runout Air Velocity: 425 ft./min. Actual Winter Infil.: 120 CFM Actual Loss: 0.148 in.wg./100 ft. Actual Summer Infil.: 120 CFM � AreaItem- -U - Htg :Seri CIg Lat 'Sen D:escription Quantity Value � HTM: Loss _HTM. Gain .Gain S-Wall-15A15-0ocw-2 20 X 8.5 170 0.066 6.3 1,069 0.5 0 82 W -Wall-15A15-0ocw-2 24 X 8.5 133 0.066 6.1 805 0.4 0 54 N -WalI-15A15-0ocw-2 20 X 8.5 170 0.066 6.3 1,069 0.5 0 82 W-GIs-V01 shgc-0.27 100%S 36 0.280 20.7 746 7.9 0 286 W-GIs-V01 shgc-0.27 100%S 35 0.280 20.7 725 7.9 0 278 Floor-21B-24 24 X 19 456 0.017 1.3 574 0.0 0 0 Floor-22B-10ph 24 ft..Per. 24 0.481 35.6 854 0.0 0 0 Subtotals for Structure: 5,842 0 782 Infil.: Win.: 120.0, Sum.: 119.9 413 23,350 9,654 3.154 2,209 1,304 Ductwork: 0 0 AED Excursion: 432 Room Totals: 15,496 2,209 2,518 • C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Residential'&Light'Coinmercial HVAC Loads: Elite`Software D,'evelopment,Inc. Stonehenge Associates Leonardo_ Residence Troy;NY 121So. Page 17 1 Detailed Room Loads - Room 3 - Bath #2 (Average Load Procedure) C General Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 5.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 40.0 sq.ft. Supply Air: 15 CFM Ceiling Height: 8.5 ft. Supply Air Changes: 2.6 AC/hr Volume: 340 cu.ft. Req.Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 15 CFM Percent of Supply.: 0 % Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 296 ft./min. Percent of Supply: 0 Runout Air Velocity: 296 ft./min. Actual Winter Infil.: 20 CFM Actual Loss: 0.151 in.wg./100 ft. Actual Summer Infil.: 20 CFM Item Area . ;U-, Htg Seri Clg - Lat vSen . Description _ Quantity Value HTM: Loss HTM , , Gain Gain I N-Wall-15A15-0ocw-2 11.5 X 8 92 0.066 6.3 577 0.5 0 44 Floor-21A-24 8 X 5 40 0.025 1.9 74 0.0 0 _ 0 Subtotals for Structure: 651 0 44 Infil.:Win.:20.0, Sum.: 20.0 69 23.348 1,611 3.159 369 218 Ductwork: 0 0 AED Excursion: 54 Room Totals: 2,262 369 316 C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM s Rvac.-Residential:8 Light Cor`rimerc`ial'HVAG8Loaiis: - -fi Elite Software Development,Inc. Stonehenge Associates r( ' Leonardo.Residence TroY;.NY 12180 _ d Page 18 J Detailed Room Loads - Room 4 - Mech Room (Average Load Procedure) General' - - - Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 11.5 ft. Zone Number: 1 Area: 115.0 sq.ft. Supply Air: 29 CFM • Ceiling Height: 8.5 ft. Supply Air Changes: 1.8 AC/hr Volume: 978 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 29 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 335 ft./min. Percent of Supply: 0 % Runout Air Velocity: 335 ft./min. Actual Winter Infil.: 40 CFM Actual Loss: 0.127 in.wg./100 ft. Actual Summer Infil.: 40 CFM Item - Area . -u= Htg Sen .:Cig Lat __ - Seni [Description- Quantity Value __HTM:__ Loss HIM Gain Gain E -Wall-15811-0w-2 11.5 X 8.5 97.8 0.071 6.8 668 0.5 0 47 S -Wall-15611-0w-2 10 X 8.5 85 0.071 6.8 580 0.5 0 41 Floor-21B-24 11.5 X 10 115 __ 0.017 1.3 _ 145 0.0 0 0 Subtotals for Structure: 1,393 0 88 Infil.: Win.:40.3, Sum.: 40.3 139 23.349 3,243 3.154 742 438 Ductwork: 0 0 AED Excursion: 109 Room Totals: 4,636 742 635 • • C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Residen &tial Light com ier`cial'HVAC Loafs — _.-- Elite Software Development;Inc:' Stonehenge Associates. it- Leonardo Residence- Troy,NY 12=180: `_ Detailed Room Loads - Room 5 - Bedroom 3 (Average Load Procedure) _ _J General Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 11.0 ft. Zone Number: 1 Area: 165.0 sq.ft. Supply Air: 41 CFM Ceiling Height: 8.5 ft. Supply Air Changes: 1.8 AC/hr Volume: 1,403 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 41 CFM Percent of Supply.: 0 % Runout Duct Size: 5 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 301 ft./min. Percent of Supply: 0 % Runout Air Velocity: 301 ft./min. Actual Winter Infil.: 19 CFM Actual Loss: 0.075 in.wg./100 ft. Actual Summer Infil.: 19 CFM i Item - Area U Htg Sen Clg Lat; _ Sen Description, Quantity Value • HTM _ Loss HTM , Gam 'Gain E -Wall-15B13-0m-6 11 X 8.5 75.5 0.063 5.2 389 0.1 0 6 N-Wall-15B13-0m-6 15 X 8.5 127.5 0.063 5.8 745 0.2 0 24 E-GIs-V01 shgc-0.27 0%S 18 0.280 20.7 373 28.1 0 506 Floor-21A-24 11 X 15 165 0.025 1.9 305 0.0 0 0 Subtotals for Structure: 1,812 0 536 Infil.: Win.: 18.6, Sum.: 18.6 64 23.358 1,497 3.152 342 202 Ductwork: 0 0 AED Excursion: 153 Room Totals: 3,309 342 891 C:1...1Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Resideritial'&Light Corriinercial HVA'C`Loadsii& Elite'Software.Development;Inc. 'Stonehenge Associates. Leonardo Residence Troy;NY 12180 Page 20 Detailed Room Loads - Room 6 - Upper Family Room (Average Load Procedure) GeneraI .._ Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 24.0 ft. Zone Number: 1 Area: 312.0 sq.ft. Supply Air: 199 CFM Ceiling Height: 6.0 ft. Supply Air Changes: 6.4 AC/hr Volume: 1,872 cu.ft. Req.Vent. Clg: 0 CFM • Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 100 CFM Percent of Supply.: 0 % Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 372 ft./min. Percent of Supply: 0 % Runout Air Velocity: 372 ft./min. Actual Winter Infil.: 42 CFM Actual Loss: 0.072 in.wg./100 ft. Actual Summer Infil.: 42 CFM ritem - Area -U- • Htg Sen ' CIg Let Sen' Descri- _ Quail* .p _ __�__ Quanty Value HTM Loss HTM Gain. Gain. W -Wall-12F-0sw 24 X 6 39 . 0.065 4.8 188 0.7 0 26 W -GIs-V01 shgc-0.27 0%S 105 0.280 - 20.7 2,176 28.1 0 2,950 UP-Roof-18A-38 13 X 24 312 0.029 2.1 670 0.5 0 154 Subtotals for Structure: 3,034 0 3,130 Infil.: Win.: 41.8, Sum.: 41.8 144 23.354 3,363 3.153 769 454 Ductwork: 0 0 AED Excursion: 743 Room Totals: 6,397 769 4,327 • C:1...1Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM 'Rift c-;Residential8�•Light:Commercial HUAG.Loads ` - - Elite Soffware'D'evelopmerit,Inc. Stonehenge Associates .Leonardo Residence I Troy,NY 12180, _ -.0 Page;21 Detailed Room Loads - Room 7 - Upstairs Bath (Average Load Procedure) 'General_ ; Calculation Mode: Htg. &cig. Occurrences: 1 Room Length: 8.0 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 64.0 sq.ft. Supply Air: 15 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.8 AC/hr Volume: 512 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 15 CFM Percent of Supply.: 0 Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 313 ft./min. Percent of Supply: 0 % Runout Air Velocity: 313 ft./min. Actual Winter Infil.: 12 CFM Actual Loss: 0.168 in.wg./100 ft. Actual Summer Infil.: 12 CFM 'Item Area lJ Htg Sen Cig .Lat Sen LDescription Quantity, .Value - HIM Loss- HIM Gain Gain i S-Wall-12F-0sw 8 X 5 31 0.065 4.8 149 0.7 0 21 S-GIs-V01 shgc-0.27 58%S 9 0.280 20.7 186 10.8 0 97 UP-Roof-18A-38 8 X 8 64 0.029 2.1 137 0.5 0 32 Floor-Part-21 B-24 8 X 8 64 0.017 0.0 1 0.0 0 1 Subtotals for Structure: 473 0 151 Infil.:Win.: 11.6, Sum.: 11.6 40 23.350 934 3.150 214 126 Ductwork: 0 0 AED Excursion: 57 Room Totals: 1,407 214 334 C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Residential'&Light Commercial HVAC-Load`s. - Elite-Software Development I Stonehenge Associates, +' Leonardo Residence j Troy,_NY 12180 �� Pa-''e 22 Detailed Room Loads - Room 8 - Loft Sleeping Area (Average Load Procedure) General Calculation_Mode: Htg. &clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 24.0 ft. Zone Number: 1 Area: 360.0 sq.ft. Supply Air: 128 CFM Ceiling Height: 6.0 ft. Supply Air Changes: 3.5 AC/hr Volume: 2,160 cu.ft. Req. Vent. Clg: ,0 CFM Number of Registers: 2 Actual Winter Vent.: 0 CFM Runout Air: 64 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 325 ft./min. Percent of Supply: 0 % Runout Air Velocity: 325 ft./min. Actual Winter Infil.: 81 CFM Actual Loss: 0.068 in.wg./100 ft. Actual Summer Infil.: 81 CFM Cffem' - Area Htg _ Sen. Clg Lat S -U- ' ne Descriptiori Quantity - .Value _ HIM Loss , HIM Gain ,Gain N-Wall-12F-0sw 15 X 5 57 0.065 4.8 274 0.7 0 38 E-Wall-12F-0sw 24 X 7 138 0.065 4.8 664 0.7 0 92 S-Wall-12F-0sw 7.5 X 5 28.5 0.065 4.8 137 0.7 0 19 N-GIs-V01 shgc-0.27 100%S (2)' 18 0.280 20.7 372 7.9 0 142 E -GIs-V01 shgc-0.27 0%S(2) 30 0.280 20.7 622 28.1 0 842 S -GIs-V01 shgc-0.27 58%S 9 0:280 20.7 186 10.8 0 97 UP-Roof-18A-38 15 X 24 360 0.029 2.1 773 0.5 0 177 Floor-Part-21 B-24 24 X 15 360 0.017 0.0 6 0.0 0 6 Subtotals for Structure: 3,034 0 1,413 Infil.:Win.: 81.4, Sum.: 81.4 281 23.351 6,550 3.152 1,499 884 Ductwork: 0 0 AED Excursion: 476 Room Totals: 9,584 1,499 2,773 • C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM' I Rhvac-Residential&Light-Commercial HVAC'Loads . - - Elite-Software Development;Inc., Stonehenge Associates Leonardo Residence Troy,NY 12180 _ _ - _._ Page 23;, Detailed Room.Loads - Room 9 - Hall @ Stairs (Average Load Procedure) General — -- -- - Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 6.0 ft. System Number: 1 Room Width: 6,0 ft. • Zone Number: 1 • Area: 36.0 sq.ft. Supply Air: 0 CFM Ceiling Height: • 8.0 ft. Supply Air Changes: 0.0 AC/hr Volume: 288 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 0 CFM Percent of Supply.: 0 % Runout Duct Size: 0 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 0 ft./min. Percent of Supply: 0 % Runout Air Velocity: 0 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.000 in,wg./100 ft. Actual Summer Infil.: 0 CFM Item Area =U= - Htg Sen ' Gig Lat ` •Sen Description ' ' Quantity Value HIM'. . Loss • HTM _ .Gain 'Gain I Floor-Part-21 B-24 6 X 6 36 0.017 0.0 _ 1 _ 0.0 0 1 Subtotals for Structure: 1 0 1 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 0 0 AED Excursion: 0 Room Totals: . 1 0 1 C:1...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac-Residential&Light Commercial HVAC'Ldails Elite'S,ofti.are`peveloprnent;Inc. ' 0 Stonehenge Associates Leonardo.Residence Troy,.NY 12180. Page.24 Detailed Room Loads - Room 10 - Entry Hall (Average Load Procedure) LGeneral'. Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 16.0 ft. System Number: 1 Room Width: 4.0 ft. Zone Number: 1 Area: 64.0 sq.ft. Supply Air: 13 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.5 AC/hr Volume: 512 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 13 CFM Percent of Supply.: 0 % Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: . 268 ft./min. Percent of Supply: 0 % Runout Air Velocity: 268 ft./min. Actual Winter Infil.: 9 CFM Actual Loss: 0.124 in.wg./100 ft. Actual Summer Infil.: 9 CFM Imte v Area -u- Htg, Sen Ctg L•at Sen i I Description _ Quantity: Value. ___ HTM Loss _ HTM Gain Gain N -Wall-12F-Osw 4 X 8 11 0.065 4.8 53 0.7 0 7 N-Door-11 P 3 X 7 21 0.290 21.5 451 6.1 0 128 Floor-Part-21 B-24 4 X 16 64 0.017 0.0 1 0.0 0 1 Subtotals for Structure: 505 0 136 lnfil.: Win.: 9.3, Sum.: 9.3 32 23.344 747 3.156 171 101 Ductwork: 0 0 AED Excursion: 49 Room Totals: 1,252 171 286 C:1...1Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM mac-Residential&Light Commercial HVAC Loads Elife SoftWare;Developm`erit;lric: Stonehenge Associates Leonardo Residence el Troy,.NY 12180 _ _ Page 25 Detailed Room Loads - Room 11 - Kitchen (Average Load Procedure) General; , Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 10.0 ft. System Number: 1 Room Width: 8.8 ft. Zone Number: 1 Area: 88.0 sq.ft. Supply Air: 18 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.5 AC/hr Volume: 704 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 18 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 206 ft./min. Percent of Supply: 0 % Runout Air Velocity: 206 ft./min. Actual Winter Infil.: 23 CFM Actual Loss: 0.049 in.wg./100 ft. Actual Summer Infil.: 23 CFM Will ' ' Area, U; Htg • Sen Clg , ,!,:at _ Sen I Description _ Quantity,: Value _HIM Loss HIM Gain - Gain; N-Wall-12F-0sw 10 X 8 80 0.065 4.8 385 0.7 0 54 UP-Roof-18A-38 4 X 8.8 35.2 0.029 2.1 76 0.5 0 17 Floor-Part-21 B-24 8.8 X 10 88 0.017 0.0 1 0.0__ 0 1 Subtotals for Structure: 462 0 72 Infil.: Win.: 23.2, Sum.: 23.2 80 23.350 1,868 3.150 427 252 Ductwork: 0 0 AED Excursion: 67 Room Totals: 2,330 427 391 C:\..,\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM Rhvac=Residential,&L-iglit'Commerdial,HVAC LOpt"' Elite,Softwate;D'evelopment,Inc. Stonehenge Associates Leonardo Residence Troy,NY 12180 . .. _ ' _ - Page 26 Detailed Room Loads - Room 12 - Family Room (Lower) (Average Load Procedure) General _ _ J Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 24.0 ft. Zone Number: 1 Area: 312.0 sq.ft. Supply Air: 322 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 7.7 AC/hr Volume: 2,496 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 3 Actual Winter Vent.: 0 CFM Runout Air: 107 CFM Percent of Supply.: 0 % Runout Duct Size: 7 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 402 ft./min. Percent of Supply: 0 % Runout Air Velocity: 402 ft./min. Actual Winter Infil.: 116 CFM Actual Loss: 0.083 in.wg./100 ft. Actual Summer Infil.: 116 CFM ! Ite • T m - Area =U= Htg _Sen Clg Lat Sen f Description _ Quantity Value HTM , _ Loss HTM - Gain Gain, N-Wall-12F-0sw 13 X 8 104 0.065 4.8 —500 0.7 0 70 S-Wall-12F-0sw 13 X 8 104 0.065 4.8 500 0.7 0 70 W-Wall-12F-0sw 24 X 8 42 0.065 4.8 202 0.7 0 28 W -GIs-V01 shgc-0.27 0%S(2) 108 0.280 20.7 2,238 28.1 0 3,034 W -GIs-V01 shgc-0.27 0%S • 42 0.280 20.7 870 28.1 0 1,180 UP-Roof-18A-38 13 X 24 312 0.029 2.1 670 0.5 0 154 Floor-Part-21 B-24 24 X 13 312 0.017 _0.0 5 0.0 0 5 Subtotals for Structure: 4,985 0 4,541 Infil.: Win.: 116.1, Sum.: 116.0 400 23.350 9,340 3.153 2,137 1,261 Ductwork: 0 0 AED Excursion: 1,202 • Room Totals: 14,325 2,137 7,004 C:\...1Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM • -H `a Rhvac-Residential.&L•ight:Gommercial HVAC'Loads • Elite SoftwareDevelopmerit;Inc >Stonehenge Associates ' Leonardo Residence Troy,.NY 12180 ,_ ,0 _ Page27, Detailed Room Loads - Room 13 - Stair Well (Average Load Procedure) General 1 Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 6.8 ft. System Number: 1 Room Width: 8.0 ft. Zone Number: 1 Area: 54.4 sq.ft. Supply Air: 20 CFM Ceiling Height: 18.0 ft. Supply Air Changes: 1.2 AC/hr Volume: 979 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 20 CFM Percent of Supply.: 0 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 231 ft./min. Percent of Supply: 0 % Runout Air Velocity: 231 ft./min. Actual Winter Infil.: 16 CFM Actual Loss: 0.062 in.wg./100 ft. Actual Summer Infil.: 16 CFM Item Area "-U.= 'Htg Sen Clg Lat Sen Description Quantify V..al.ue. :, HTM Loss , HTM . Gain Gain.. S-Wall-12F-0sw 6.8 X 8 45.4 0.065 4.8 218 0.7 0 30 S-GIs-V01 shgc-d.27 0%S 9 ' 0.280 20.7 186 14.8 0 133 UP-Roof-18A-38 6.8 X 8 54.4 0.029 2.1 117 0.5 0 27 Floor-Part-21 B-24 8 X 6.8 54.4 0.017 0.0 1 0.0 0 1 Subtotals for Structure: 522 0 191 Infil.: Win.: 15.8, Sum.: 15.8 54 23.346 1,270 3.162 291 172 Ductwork: 0 0 AED Excursion: 75 Room Totals: 1,792 291 438 C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM ? 1y_ V -Rv hac Residen o tial&Light C mmercial HV I A-a'ds AC 'Elite Software'Development,Inc.' Stonehenge Associates. Leonardo Residence Troy,NY 12180. __ _ .._ .__ Page 28, Detailed Room Loads - Room 14 - Bath #1 (Average Load Procedure) General Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 5.0 ft. System Number: 1 Room Width: 7.8 ft. Zone Number: 1 Area: 39.2 sq.ft. Supply Air: 15 CFM Ceiling Height: 8.0 ft. Supply Air Changes: • 2.8 AC/hr Volume: 313 cu.ft. Req. Vent. Clg: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 15 CFM Percent of Supply.: 0 % Runout Duct Size: 3 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 301 ft./min. Percent of Supply: 0 % Runout Air Velocity: 301 ft./min. Actual Winter Infil.: 12 CFM Actual Loss: 0.156 in.wg./100 ft. Actual Summer Infil.: 12 CFM Item Area -U'L Htg Sen Clg 'Let • Sen i:Description __ Quantity Value HIM Loss_ HTM Gain _ Gain S-Wall-12F-0sw 5 X 8 32 0.065 4.8 154 • 0.7 0 21 S-GIs-V01 shgc-0.27 0%S 8 0.280 20.7 166 14.8 0 118 Floor-Part-21 B-24 7.8 X 5 39.2 0.017 0.0 1 0.0 0 1 Subtotals for Structure: 321 0 140 Infil.: Win.: 11.6, Sum.: 11.6 40 23.350 934 3.150 214 126 Ductwork: 0 0 AED•Excursion: 55 Room Totals: 1,255 214 321 • • C:1...1Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM .w. Rhvac:-Residential'&=Light'Commercial HVAC Loads • Elite Software Development,Inc: Stonehenge Associates Leonardo Residence 1 Troy,NY 12180' - - -0 Page,29_j Detailed Room Loads - Room 15 - Bedroom 1 (Average Load Procedure) I General - Calculation Mode: Htg. &clg. Occurrences: 1 Room Length: 10.8 ft. System Number: 1 Room Width: 11.5 ft. Zone Number: 1 Area: 123.6 sq.ft. Supply Air: 68 CFM Ceiling Height: • 8.0 ft. Supply Air Changes: 4.1 AC/hr ' Volume: 989 cu.ft. Req. Vent. Cig: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 68 CFM Percent of Supply.: 0 % Runout Duct Size: 6 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 344 ft./min. Percent of Supply: 0 % Runout Air Velocity: 344 ft./min. 'Actual Winter Infil.: 52 CFM Actual Loss: 0.076 in.wg./100 ft. Actual Summer Infil.: 52 CFM rltem - ' Area -U-. Htg 'Seri—` ' .Clg ,--Lit — Sen I Description Quantity:- Value HIM - Loss. HTM Gain Gain S -Wall-12F-Osw 11.5 X 8 92 0.065 4.8 443 0.7 0 62_ E -Wall-12F-0sW 10.8 X 8 71 0.065 4.8 342 0.7 0 48 E-GIs-V01 shgc-0.27 0%S 15 0.280 20.7 311 28.1 0 421 Floor-Part-CustomFloor4 11.5 X 123.6 1.000 1.0 124 1.0 0 124 10.8 Subtotals for Structure: 1,220 0 655 Infil.: Win.: 51.7, Sum.: 51.6 178 23.354 4,157 3.152 951 561 Ductwork: 0 0 AED Excursion: 252 Room Totals: 5,377 951 1,468 • • • C:\...\Leonardo Residence.rh9 . Thursday, May 28, 2020, 11:43 AM T ' Rhvac-Residential.&Liglit.Comniercial`HVAC Loads 'Elite Software Development„Inc Stonehenge Associates Leonardo Residence Troy,NY 12180 Page 30( System I Room Load Summary Htg • Htg Run: Run 'Gig Clg; Cig Air I Room: Area Sens Rad Duct Duct Sens Lat •Norn Sys I No Name' _SF_ Btul' Len Size , Vel`. Btuh Btuh, CFM CEM I ---Zone 1--- 1 =Bedroom 2 124 5,377 7.5 1-6 344 1,468 951 68 • 68 2 Great Room 480 15,496 21.6 2-5 425 2,518 2,209 116 116 3 Bath#2 40 2,262 3.2 1-3 296 316 369 15 15 4 Mech Room 115 4,636 6.5 1-4 335 635 742 29 29 5 Bedroom 3 165 3,309 4.6 1-5 301 891 342 41 41 6 , Upper Family 312 6,397 8.9 2-7 372 4,327 769 199 199 Room 7 Upstairs Bath 64 1,407 2.0 1-3 313 334 214 15 15 8 Loft Sleeping Area 360 9,584 13.4 2-6 325 2,773 1,499 128 128 9 Hall @Stairs 36 1 0.0 1-0 0 1 0 0 0 10 Entry Hall 64 1,252 1.7 1-3 268 286 171 13 13 11 Kitchen 88 2,330 3.2 1-4 206 391 427 18 18 12 Family Room 312 14,325 20.0 3-7 402 7,004 2,137 322 322 (Lower) 13 Stair Well 54 1,792 2.5 1-4 231 438 291 20 20 14 Bath#1 39 1,255 1.8 1-3 301 321 214 15 15 15 Bedroom 1 124 5,377 7.5 1-6 344 1,468 951 68 68 . HW Piping _ 262 _ System 1 total 2,377 75,062 104.7 23,173 11,286 1,066 1,066 System 1 Main Trunk Size: 12x16 in. Velocity: 799 ft./min Loss per 100 ft.: 0.094 in.wg . I Cooling System Summary _ . . , _ . Cooling • -Sensible/Latent • ,-Sensible Latent Total L. Tons Split Btuh Btuh_ ' _ Btuh Net Required: 2.87 67%/33% 23,173 11,286 34,459 Actual: 3.79 75%/25% 34,125 11,375 45,500 Equipmerit.Data,': _ .. Heating System Cooling System Type: Propane Boiler Standard Air Conditioner Model: NHB-055 ASX140481 K* Indoor Model: CSCF4860N6D*+TXV Brand: NAVIEN ASX14 Description: Natural Gas or Propane Boiler Efficiency: 95 AFUE 14.5 SEER Sound: 0 0 Capacity: 51000 Btuh 45500 Btuh Sensible Capacity: n/a 34,125 Btuh Latent Capacity: n/a 11,375 Btuh AHRI Reference No.: n/a 7541376 C:\...\Leonardo Residence.rh9 Thursday, May 28,2020, 11:43 AM ,r e Rhvac-Residential&Ligfit,Commerciai HVAG Loads Elite Software Development,Inc Stonehenge Associates Leonardo Residence boy,NY 12180, i- Page 31] Radiant Floor Report C:\...\Leonardo Residence.rh9 Thursday, May 28, 2020, 11:43 AM RESOLUTION SETTING PUBLIC HEARING ON SEWAGE DISPOSAL VARIANCE APPLICATION OF ADAM LEONARDO RESOLUTION NO.: BOH 40,2019 INTRODUCED BY: Mr.Anthony Metivier D �+ V WHO MOVED ITS ADOPTION k� SECONDED BY: Mr. George Ferone ` � TOWN OF OUEENSSU y BUILDING&CODES WHEREAS, the Queensbury Town Board serves as the Town's Local Board of Health and is authorized by Town Code Chapter 136 to issue variances from the Town's On-Site Sewage Disposal Ordinance,and WHEREAS, Adam Leonardo (Applicant) has applied to the Local Board of Health for a variance from Chapter 136 to install a leach system: 1. 5' from the property line in lieu of the required 10' setback; and 2. 87' from the well in lieu of the required 100' setback; on property located at 12 Hall Road Extension in the Town of Queensbury, NOW,THEREFORE,BE IT RESOLVED, that the Town of Queensbury's Local Board of Health will hold a public hearing on Monday,November 4t',2019 at 7:00 p.m. at the Queensbury Activities Center, 742 Bay Road, Queensbury, to consider Adam Leonardo's sewage disposal variance application concerning property located at 12 Hall Road Extension, Queensbury (Tax Map No.: 289.11-1-17) and at that time all interested persons will be heard,and BE IT FURTHER, 289.11-1-17 RC-0255-2020 Leonardo, Adam & Rebecca 12 Hall RdExt SFD W/gas FP 2158 s.f. RESOLVED, that the Local Board of Health authorizes and directs the Queensbury Town Clerk to publish the Notice of Public Hearing presented at this meeting and send a copy of the Notice to neighbors located within 500' of the applicant's properly as required by law. Duly adopted this 21"day of October,2019,by the following vote: AYES: Mr. Ferone,Mrs. Switzer,Mr. Strough,Mr.Metivier,Mrs.Atherden NOES: None ABSENT: None