Loading...
2005-295 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 4z Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20050295 Date Issued: Thursday, May 25, 2006 This is to certify that work requested to be done as shown by Permit Number P20050295 has been completed. Tax Map Number: 523400-301-009-0001-038-000-0000 Location: 30 WESTERN RESERVE Trl Owner: WESTERN RESERVE, LLC Applicant: WESTERN RESERVE, LLC This structure may be occupied as a: Garage - 2 Cars Attached By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050295 Application Number: A20050295 Tax Map No: 523400-301-009-0001-038-000-0000 Permission is hereby granted to: WESTERN RESERVE. LLC For property located at: WESTERN RESERVE Trl in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: WESTERN RESERVE, LLC 395 BIG BAY Rd Garage-2 Cars Attached UEENSBURY, NY 12804-0000 Single Family Dwelling $250,000.00 Q Total Value $250,000.00 Contractor or Builder's Name / Address Electrical Inspection Agency HAYES CONSTRUCTION GROUP 396 BAY Rd 01 TEENSBi TRY. NY 12804-0000 Plans&Specifications 2005-295 LOT 7 WESTERN RESERVE TRAIL 2200 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE, $323.80 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday, August 08, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town Quee jury- `��W st 08, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement r Check Residential Plan Review: One&a Two Family Dwellings /N1N/A (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK LIM Dampprooliing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise let t t Spiral Not Allowed From 2 Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More an 4"in Ht. Safety Glazing Notes For Required AreasON M Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level cy Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Ate- Permit No. S - Building&Codes Office-Department of Community Development-Town of Queensbury Fee Paid � �)U 742 Bay Road,Queensbury,NY 12804 Recreation Fee U?) Dave Hatin,Director codes@aueensburv.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building Permit Application Application & Plans subject to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder ��`7r Uc 1evJ Owner: Address: Address: Home Phone: Home Phone: Email Address: Email Address: Cell Phone: Cell Phone: FAX Phone: FAX Phone: Parson responsible for supervision of work with respect to building and codes compliance: Name: 5�.. Address: Phone ?1.2 - Location of proposed construction: '7�struction: Lot No. Legal Address: i t!/ 9& 26l Tax Map Number: 1 t/� s Q 1 . 9 — f- subdivision Name: ����At-3 e7"- 4F Estimated Cost of Construction: $ ZOO., oC>C> Proposed construction is for: e Residential Use _Commercial Use Name of Business: 3 Q� If proposed construction is an addition,what will use of new addition be? 3 J New Addition Alteration Proposed Construction td Floor 2nd floor Other Total Proposed structure (Occupancy Type) Sq.Ft. sq.ft. Sq. Ft. Square feet Height Ft.&In. Single-Family Dwelling DO oo 2,2 Q 0 O Two-Family Dwelling Townhouse Multifamily Dwelling Number of Units: Office Mercantile Manufacturing Other: Attached Garage 1 2, 3 d(p K�3 Type of Heating System: Electric, Oil,e Wood, orced Hot Al , Baseboard, Other: If a fireplace and/orwoodstove are being installed, please refer to a separate applicati(ff),,CCEIVED Applications are subject to Zoning Administrator, Code Compliance, and Stru t 'al k*(n view. The Building and Codes Office will allow commencement of your proposed pf oJect only after issuance of your permit. TOWN OF DUEENSBURY BUILDING AND CODE Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all T Jc Ltion. i Date: ! �) Applicant/Builder Signature: The application of I dated is hereby approved and permission granted for the cons ructi4rl, reconstruction or a ter I n a bui g/and =ac .ry structure as set forth above. Date: r) Authorized Signature. L:\Sue Hemingway\Building.Permit.F RMS\Principal Structure Permit Application.doc V:12/14/04 Application for Permit-Septic Disposal System, Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 161-8256 1. OWNER INFORMATION ........ Office Use Location of installation: C7 we-wi '►2r�) g c n File Permit No. - - Tax Map No. ; Fee Paid Owner's Name: ................... ............................................. Address: 2. INSTALLER'S NAME ��7 S PHONE NO. 3. RESIDENCE INFORMATION: (circle year o dwelling, indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980-1991 x 130 gal/bdrm = 1991 -present x 110 gal/bdrm = Garbage Grinder Installed yes / no Spa or Hot Tub Installed yes ! no 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) h e Ground Water Bedrock or Im ervious Material er Supply sand at what depth at what depth unici al Rolling m illEfeet feet well Steep slope clay if well;water supply _%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: C> minute per inch ec-4- i rn- tJArC-`e�_ A���viro Ohs 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. t,U5 8� ��� � ►�.� Septic Tank: Z �2gallon(min. size I,000ga1.) P '�� Tile Field: each trench _ft. Total System Length: ;?5 0 ft. \ Seepage Pit(s): number of size of each: ft. by ft. t Size of Stone to be used: # / depth or thickness feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136.29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of th o Queensbury Sanitary Sewage Disposal Ordinance. Signa re fiesponsible person ate 'l'nwtt cii <�ttec�ttai�u'ry S(.%Vel•s and .'rwo)"e Disposal Chapter Appendix C. A-11.80MI'VION. FIELD SI:I'/1ILA,'I'IWIJ ttI��Zt,Jittl�[�lI►�1�1'I';� ' . .fit 't1r�.ItT GENIC; .. �•- 4 ! rear l+�yr�RPttq� Cz I 'A • I ' h I . f i 7. SlgNA►TURE &WORMATION FML YVM=,ro r>rr--4vr.'4 %Y 00-......:;::' i•:; Septic Inspection Report Office No. (518) 761-8256 Date InspectiIrest r ce' ed• Queensbury Building&Code Enforcement Arrive: Zp art: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's InNAME: MF� , ea& IT NO.:LOCATION: ��h��Rl.� R��� F T�AECT ON: RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Caps Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot N Engineer Report anO As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front iddle Rear System Use Sta s• Approved Partial Approved and needs to be re-inspected,please call the Building& Codes Office Disapproved Last revised 1/6/05 Queensbury Building & Code EnfofeRment - Residential inal Inspection Office No. (518)761-8256 Arrive:�r'sZlmtViahs. part: ' pm Date Inspection request received: d�2z-o6, InspectNAME: e5 b_ Z7SLOCATION: � P rue - n.T -23--c)c TYPE OF STRUCTURE: �F Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation �Z Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace areaFurnace/Hot Water Heater operating v -71.p Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 �`n L, Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum �l Basement stairs closed rise>4 inches Garage Floor PitchedGarage fireproofing/'44 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan , As Built Septic System/Sewer Dept.Inspection Sticker 4 Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised—I 00405.doc MAP REFERENCE: \ WESTERN RESERVE, LLC \ DATED: JULY 15, 2003 \ LAST REVISED: OCTOBER 8, 2004 BY: VAN DUSEN & STEVES FILED IN THE WARREN COUNTY CLERK'S OFFICE: DECEMBER 13, 2004 yACNS17c Mal Cj�\ O,o LOT 8 • � s \ 0'�pc�Tlpy �<<t1' A �6 LOT 7 , 23,482 SQ. FT. \ `yopo �s r 41 9�syo GSF _ � P " O % ABSORPTION Tr k 9 6 TRENCHES' ��� Oy110, 5 ® 47' EA. <'`Z1 DISTRIBUTION BOX as0�O' 1.500 GAL. SEPTIC TANK O LOT 6 O �� O� 5 I�U► , ````t tUiNNtr�����i'h,� fi►t{ 4 SEPTIC SYSTEM — AS BUILT a e► APRIL 13, ALTERArm OR A � �L TO A S Scale 1'=30' u S YAP SEARHO A UCENSED LAND SURVEYORS SEAL IS A Map of a Survey made for MATOON OF SECRON 72%%M-MMON a OF TAE NEW YORK STATE EDUCATION LAW.' .DWYS t e V e S MARKED COMES FROM,,,E°WCRU`OF % HARKID YDiH AN ORIGINAL a THE LAND SURVEYORS SEAL �REW2 BE TRVEWS � Hayes Construction Group — 1 -CFJt1FTCAl10NS M7DICATED NEREON 9QAFY,NAT y T TNS SURVEY WAS PREPARED M ACCORDANCE YATN THE ``✓. Land Surveyors E70 THE CODE OF PRACE A FOR TKIM SURVEYORS ADOPifD i BY THE NEW PORK STATE AS90CIATION OF PROEESSIOlIAL lANO SURVEYORS.SM CERTFICATIONS SHALL RUN ONLY TO THE PERSON FOR*M THE SURVEY IS PREPARED.AND ON NS REHALF TO THE TITLE COMPANY.OOVETODIENTAL , New York 12804 "`ECY AND LDMG INSMUITION USTED HEREON'AND Town of Queensbury, Warren County, New York 169 Haviland Road Queensbur y TO THE ASSMEES OF THE LETIDW NSTITUTKIN.• 0 5124106 SEPTIC SYSTEM AS—BUILT HAVES & HAVES (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 01191-7 Final Survey InspOetiOR Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received '� - NAME: LOCATION: E' PERMIT#: a 0 Final Survey Plot Plan Aggroved Denied The attached final survey has been received by the Dept.of Community Development. Upon review the survey has b CraiWov,4, Zoning Administrator Queensbury Building & Code Enforcement - Re ' e tia inal Inspection Office No. (518)761-8256 Arrive: Z'ft?& in e rtt: . S`,,Cj am Date Inspection request received: Inspector's Initial NAME: E P IT#: _C LOCATION: �� W�L�Z1�Q !> l E: _ TYPE OF STRUCTURE: Comments Yes No NIA p7V � ,� BuildingNumber/Address visible from road ��`G Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches ov E-k. C3�;{-� v�\� � Roof Complete/Exterior Finish Complete 0?� Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Y Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inchesAn�n Interior Handrails @ stairs 2 or more risers � !D Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade V—k tA Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke De ctors: / Every level: Every Bedroom: Outside every bedroomj�ea: 7/ Inter Connected: ✓ Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area eeo Crawl Spaces 18 inch x 24 inch access, 1 s . 1-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure �y � Final Electrical ©� Dov— Final Survey Plot Plan L �(] QP-Dwt��% f—��%►� As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required X—C) Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Septic Inspe�tjon Report Office No. (518)761-8256 Date Ipspection request received: Queensbury Building&Code Enforcement Arriye: am/pin Depart:< am/pm 742 Bay Rd.,Queensbury,NY 12804 InsfFctor's Initials: Auhr�,? NAME: 't= PERMIT NO.: �� LOCATION: �' �5��� ,SPECT ON: (� RECHECK: — Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. / Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone _Seepage Pits: Number Size: x Stone Size: l Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Caps Location/Separations Foundation to tank ft. Foundation to absorption Separation of Pits Conforms as per Plot Plan Y N [_Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use St at : Approved Partial Approved and needs to be re-inspected, please call the Building&Codes Office _Disapproved Last revised 1/6/05 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL �—A Permit No........................................Cert. N 2 9 3 9 3 8 Cut-in Card No................................ ... Owner................. ...7 � �.......................................................... . Location.�.T .. ....fit��b//` 7 ..... .................... -" .✓............. Installation Consisting of./l�.W../Vd-rc8�. l 12Y 6 Ae,0�d v`��.......... ................... ......................................... .................................................................................................................................................................................... ........................... .....,.o............................................................................................................... InstalledBy...�- ? cY...........................................Lic.No........................................... ................................. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of maki inspections at any time, and if its rules are/violated,the Company shall have the right to r ok th' rtific e. Date...1..�..z: .....0 6................. INSPECTOR.. .............................................................................. Member N.F.P.A.,I.A.E.I. y Septic Inspection Report Office No. (518)761-8256 Date Inspection equest ce' ed: Queensbury Building&Code Enforcement Arrive: am/p art: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Ini 'als- NAME: _� E IT NO.: li — 2-21"� � '�R L �'� PECT ON: — RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. -Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: .-PipingSize Type A Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial End Caps Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan N n 'neer R ort d As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: A oved ]�; artial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 116105 4 C— Septic Inspection Report Office No. (518)761-8256 Date Inspection re est re eived• Queensbury Building&Code Enforcement Arrive: if i3q D art: r a 742 Bay Rd.,Queensbujry,NY 12804 Inspector's Initia s. NAME: ! _ TT NO.: 00 LOCATIO SPECT ON: /n RECHECK: y--�� Comments and/or diagram Soil T e Sa Loam/Clay T e of at : Munici ai/Well Water Q� Waterline a aration distance ft. Well separation distance ft. Other wells: f}. —� Abso tion Field: Total length ft. Length of each trench Depth of trenches - ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank p Tank to Distribution Box Distribution Box toFiejd/Pit ve?�t-- . OpeningSealed: /Partial End Caps Location/Separations Foundation to tank ft. Foundation to absorption ft. \� Separation of Pits ft. Conforms as per Plot Plan Y n ineer Re poll and As-Built Y N Location of System on Property: Front Rear Left Side Right Side iddle Fr iddle Rear Svste a Status: Approved Partial Approved and needs to be re-inspected,please call the Building& Codes Office Disapproved Last revised 1/6/05 Septic Inspection Report \` Office No.(518) 761-8256 Date Inspection Queensbury Building&Code Enforcement Arrive:742 Bay Rd., Queensbury,NY 12804 Inspector's In NAME: E .IT NO.: LOCATION: A� 9�1 RI PECT ON: — �ol RECHECK: E Comments and/or diagram Soil T e: Sand/Loam!Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone See a e Pits: Number Size: x Stone Size: P!Ping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: pproved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved LASueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 F�k ----- ?JA- Septic Inspection Report Office No.(518) 761-8256 Date In ection ues ve Queensbury Building&Code Enforcement Arrive: 2.% a p D art: ani 742 Bay Rd.,Quee sbury,NY 12804 Inspector's Initia NAME: P / IT NO.: LOCATION: ��IzvyrV Q _ SPECT ON: RECHECK: 7�. Comments and/or diagram Soil Type, Sand /Clay Type of a : Munici al/ 11 Water Waterlines aration distance Well separation distance ft. Other wells: ft. Absorption Field: Total length Length of each trench Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box t Distribution Box to Fi I Pit -�' t ►� PEA OpeningSealed: Y/ ial End Caps Location/Separations Foundation to tank 1' ft. Foundation to absorption Z t ft. Separation of Pits ft. Co rms a er Plot Plan Y ineer Re o n As-Built Y N Lo�Onofstem on Property: Front Rear Left Side Right Side fi�._Rear System Use Stat s: Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 1/6/05 Rough Plumbing / Insulation Inspection Re-pAaoft Office No. (518) 761-8256 Date Inspection req t r ei d: Queensbury Building & Code Enforcement Arrive: = m D art: m �r 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: i NAME: "n�r,-A e ROye PER #: ZLL -z9 LOCATION: E-6- .T TINS CT ON: - - TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nall Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Ni Insulation Residential Check / Commercial Check o Proper Vent Attic Ventu- Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: LAPam Whiting\Building&Codesunspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection a ort Office No. (518) 761-8256 Date Inspection rreei Queensbury Building & Code Enforcement Arrive: a. rt: m/pm 742 Bay Road, Queensbury, NY 12804 Inspecto s I NAME: `�� _ r PE LOCATION: t"�T 0 IN TYPE OF STRUCTURE: r L Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 5 I for 15 minutes Insulati6o Residential Check/ Commercial Check Pro er Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly o duct tape COMMENTS: LAPam Whiting\Building&CodeslInspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Rough Plumbing / Insulation Inspection Report,:. Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm , Depart: „ i` am pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials• NAME: PERMIT #: LOCATION: ti INSPECT ON: C TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain J Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Li Pressure Test Water Supply Piping j- :�E - ti Air/ Head 5 .S.I for 15 minutes nsulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces -' Combustion Air Supply for Furnace Duct work sealed properlyJ No duct tape COMMENTS: ��,� i...y .>�` �,,.., .al'`� Z...- 1-4J 7i LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 px-� Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: _ Queensbury Building & Code Enforcement Arrive: am/pm Depart: ��Z� am/pm/, 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: �° .�• r INSPECT ON: A Zz,LU TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 PR.. . or 15 minutes Insulatio / Residential Check / Commercial Check Pro er Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: "5K- LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspe ion reque ' reed d: Queensbury Building & Code Enforcement Arrive: > ' a . m ' D art: -� - amp rrt 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: _, . �: LOCATION: -7 INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation Aesidential Chec Commercial Check:=ggaL Proper Vent Attic Vent Duct / Hot Water Piping Insulation i If required unheated spaces Combustion Air Supply for Furnace � � Ductwork sealed properly / No duct tape COMMENTS: LAPam Wbiting\Building&Codes\Inspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re u re e' e 3 GS. Queensbury Building & Code Enforcement Arrive: a p epart: ; D a m 742 Bay Road, Queensbury, NY 12804 Inspector's Initial F rf NAME: PER #: � LOCATION: INSPECT ON: 13 0 TYPE OF STRUCTURE: f Y" N/A Rou h Plu Nail Plates 1 ` 6-t- PluFb-;ing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / chars a of direction *rH ead or 10 ft. above highest connection for 15 minutes ✓ Pressure Test Water Supply Piping Air/ Head �E or 15 minutes r/ Hot Residential Check Commercial Check Attic Vent DWater Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed_properly / No duct to e COMMENTS: V--F)fWk 0G OuT PkWR)QED LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Framing/ Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm/ epart: �� am/ 742 Bay Road,Queensbury,NY 12804 Inspector's Initials:: NAME: PERMIT#: ao C� LOCATION: INSPECT ON: - TYPE OF STRUCTURE: 1 Y N N/A COMMENTS L>26ng Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers v, Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. �Q-�->►�� -i,� t `C;b� Stairwells 36 in. or more 1 Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls L. R if� lk Metal Strapping for Notches Top Plate 1 %2 w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X CeilingVwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) ,f/ - 7 sf above/below grade c grade Framing / Firestopping Inspection Report p nj Office No. (518) 761-8256 Date Inspection request received: '3 Queensbury Building&Code Enforcement Arrive: am/pm Depart:"7 t 6) am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: tl� � NAME: PERMIT#: LOCATION: �, , r'i INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor olts 6 ft. or less on center ,�-►�. Ic nd water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. �� Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: G' Queensbury Building&Code Enforcement Arrive: anvp Depart: - a pm 742 Bay Rd., Quee sbury,NY 12804 Inspector's Initials: f NAME: ) %'� PERMIT#: CQa S�)J LOCATION: o "r`, f? e► e y •'L INSPECT ON: 3 U TYPE OF STRUCTURE: rq_) Comments ------- -'—'----_ __ Y N N/A� Footings 1 Piers Monolithic Slab Reinforcement in Place —� The contractor is responsible for providing protection from freezing `( for 48 hours following the placement the concrete.M T— T� Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place ng F9undation/Wate - ypc of Dampproofing;Waterproofing j Footing Drain Daylight or Sump _ Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab B&OM Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation-Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. G:\SueHcmingway\Building.Codes.Inspection,FORMSToundation Inspection Report.doe January M 2003 Foundation Inspection Report Office No. (518) 761-82.56 Date Inspection reque d: Queensbury Building& Code Enforcement Arrive: .. arDepart: )a p 742 Bay Rd., Queensbury, NY 12804 Inspector's Initial C' NAME: _ _ O PERMIT#: -_ LOCATION: _T — INSPECT ON: TYPE,OF STRUCTURE: Comments Y N N/A n 7�. Footings Piers _ Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement I of the concrete. _Maferials for this purpose on site. oundation/Wallpour — Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval ^� Plumbing Under Slab �! PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway`BuiIding.Codes.Inspecti on.FORM S\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am 1 epart: T_am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: �J C i NAME: V)a_ ERMIT #: LOCATION: �/ TSPECT ON: —� TYPE.OF STRUCTURE: Comments Footings ^^ _ i Piers Mono thic Slab Rei forcement in Place v �� The contractor is responsible for Providing protection from freezing for 48 hours following the placement of the c ncrete. Ma als for this purpose on site. _ N 6 C �J F dation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing "Type of Dampproofing/'Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing I 6 mil poly for wet areas under slab Backfrll Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I.ASueHemingway\BuiIding.Cod es.Inspection.FORM S\Foundati on Inspection Report.doc January 28,2003 a- a Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: /� NAME: _ _ PERMIT#: �_��� ►� LOCATION: _ INSPECT ON: TYPE OF STRUCTURE: Comments N N/A Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this pu.Tose on site. _ Foundation/Wallpour Reinforcement in Place Foundation Danipprooting Foundation/Waterproofing "Type of Dampproofing/Waterproofing 1 Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHcmingway\Bui;ding.Codes.Inspection.FORMS1Foundation Inspection Report.doc January 28,2003 3YL. Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re est r ei 10 aLL'S Queensbury Building& Code Enforcement Arrive: an ' in epart: 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials- NAME: F,RMIT#: CS LOCATION: _ -C�/ LT. _°li _ SPECT ON: TYPE OF STRUCTURE: Comments Footings — —^ Piers Monolithic Slab ►J��- E � Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. _ Foundation/Wallpour Reinforcement in Place Foundation.Dampprooting Foundation/Waterproofing Type of Dampproofing i Waterproofing 1 Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfrll Approval Plumbing Under Slab — PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueNemingway`,Building.Codes.Inspection.FORMS\I'oundation Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report fice No. (518) 761-8256 Date Inspection request received: jueensbury Building&Code Enforcement Arrive: am/pm�' -Deepart: am/pm 142 Bay Road, Queensbury,NY 12804 Inspector's Initials:- / l � l NAME: PERMIT#: — �- LOCATION: f 7INSPECT ON: TYPE OF STRUC 49' Framing Y N N/A COMMEI T i Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s w) 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall �c.)M?kirA I ()�J Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Ilk L l N 1 .0 �. sq4 • Ile i A .." ` 341 r r,$F7 4e iE 'ti► 0 It r R O f TP -- ) eta M1n1,���--J t FILL FOR SEPTIC SY MS 0 LOrf-S #7 & 8 HAS BENPLC o AND TESTED. SYSTEMS U BE STRUCTED IN LOCAT 0 HO a ~ \\ G RAIL �/ NYS PE P.C.NACE ENGINEERING 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 January 13, 2006 Job #47320 New York State Dept. of Health 77 Mohican Street Glens Falls, NY 12801 RE: Western Reserve Subdivision- Queensbury(T) Western Reserve Trail (Lot# 7) Septic System Dear Sir/Ma'am: This letter is to inform you that I inspected the completed septic system for the house on Lot #7 of the Western Reserve Subdivision on January 3, 2006. The septic system as installed was for a four bedroom house and consisted of a 1,500 gallon septic tank and 235 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, Thomas W. Nace, P.E. cc: Dave Hatin, Town of Queensbury Mickey Hayes 1[ACNL"1'IC "Of .�� c1Ty ox- . � s NsBo�� 8� LOT 7 � 23,482 SQ. FT. ovo � � tioG ob �33 �s •sr6' �oo LOT 6 �j� Permit Number ' REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code RES check Software Version 3.5 Release lc Data filename: C:\Program Files\Check\REScheck\jackson.rck TITLE: The Jackson COUNTY: Warren STATE:New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 05/07/05 DATE OF PLANS: 511105 PROJECT INFORMATION: All COMPANY INFORMATION: Hayes Construction Group 395 Big Bay Road Qby,NY 12804 COMPLIANCE: Passes Maximum UA=535 Your Home UA=432 19.3%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1493 30.0 0.0 52 Ceiling 2: Cathedral Ceiling(no attic) 630 30.0 0.0 20 Skylight 1: Wood Frame:Double Pane with Low-E 30 0.320 10 Wall 1: Wood Frame, 16" o.c. 1638 19.0 0.0 83 Window 2: Vinyl Frame:Double Pane with Low-E 173 0.360 62 Door 1: Glass 34 0.340 12 Door 2: Solid 20 0.140 3 Door 3: Glass 34 0.300 10 Wall 2: Wood Frame, 16" o.c. 740 19.0 0.0 43 Window 1: Vinyl Frame:Double Pane with Low-E 22 0.360 8 Basement Wall 1: Solid Concrete or Masonry 1420 0.0 10.0 118 Wall height: 7.8' Depth below grade: 6.8' Insulation depth:4.0' Floor 1:All-Wood Joist/Truss:Over Outside Air 7 30.0 0.0 0 Floor 2:All-Wood Joist/Truss:Over Unconditioned Space 324 30.0 0.0 11 Furnace 1: Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment, such plans or specifications are in complianc 'thLsCod=e. Builder/Designer I Date D i NEB L W. R �O m ( ` , A moo. 0790 60 ESSIONP� REScheck Inspection Checklist New York State Energy Conservation Construction Code RES check Software Version 3.5 Release I DATE: 05/07/05 TITLE: The Jackson Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. Wall 2: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry,7.8'ht/6.8'bg/4.0'insul, R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Windows: [ ] 1. Window 2: Vinyl Frame:Double Pane with Low-E,U-factor: 0.360 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 2. Window 1: Vinyl Frame:Double Pane with Low-E,U-factor: 0.360 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: Skylights: [ ] 1. Skylight 1: Wood Frame:Double Pane with Low-E,U-factor: 0.320 For skylights without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ] Yes [ ]No Comments: Doors: [ ] 1. Door 1: Glass,U-factor: 0.340 Comments: [ ] 2. Door 2: Solid,U-factor: 0.140 Comments: [ ] 3. Door 3: Glass,U-factor: 0.300 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Outside Air, R-30.0 cavity insulation Comments: [ ] 2. Floor 2: All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number I Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly ( with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. I ( Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ J Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-I 1. [ ] J Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. ( Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. I Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. i Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. • Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for H"C Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1" and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)